{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:10:36Z","timestamp":1787764236175,"version":"build-2784847793"},"reference-count":51,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"16","license":[{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4,17]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Oblique lateral interbody fusion (OLIF) is a minimally invasive technique for treating degenerative lumbar diseases, yet the optimal supplemental fixation strategy remains debated. Interspinous fixation systems (ISFS) offer a less invasive alternative to conventional pedicle screw-based constructs, but their biomechanical performance when combined with OLIF is not well characterized.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A validated finite element model of the L3\u2013S1 lumbar spine was used to simulate OLIF at L4\u2013L5 with 5 fixation configurations: stand-alone, unilateral pedicle screw fixation, bilateral pedicle screws fixation (BPSF), ISFS, and ISFS combined with lateral screw fixation (ISFS + lateral screws fixation [LSF]). Range of motion (ROM) at the fused and adjacent segments, along with von Mises stress distributions on the endplates, interbody cage, and instrumentation, were evaluated under a 500\u2009N compressive preload and 10 N\u00b7m pure moments in flexion, extension, lateral bending, and axial rotation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>All fixation constructs reduced ROM at the fused-segment compared to the intact model. BPSF and ISFS + LSF provided the greatest stability across all loading directions, with ROM reductions exceeding 80% in most postures. ISFS alone effectively stabilized the segment during flexion-extension, but was less effective under rotational and lateral bending loads. Stand-alone OLIF exhibited the highest cage stresses and the largest residual ROM, indicating increased risk of instability and subsidence. ISFS + LSF distributed stress more evenly across the cage and endplates, comparable to BPSF, while reducing stress concentration on the spinous process base during lateral bending. Adjacent segment ROM and endplate stress remained similar across all models and the intact condition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>OLIF combined with interspinous fixation, particularly ISFS + LSF, provides a favorable biomechanical profile by enhancing segmental stability and reducing implant-related stress concentrations, while preserving adjacent segment kinematics. ISFS + LSF may serve as a less invasive alternative to BPSF, offering balanced stability and load sharing. ISFS alone is suitable for flexion-dominant loading environments, whereas BPSF remains the most robust option for multiplanar stability at the cost of increased surgical trauma. These findings support the selective use of interspinous fixation in OLIF based on patient-specific biomechanical demands.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000048346","type":"journal-article","created":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T14:01:27Z","timestamp":1776434487000},"page":"e48346","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical comparison of oblique lateral interbody fusion with interspinous versus other fixation techniques: A finite element study"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-6953-5374","authenticated-orcid":false,"given":"Zhenggang","family":"Li","sequence":"first","affiliation":[{"name":"Faculty of Life Science and Technology, Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiming","family":"Liang","sequence":"additional","affiliation":[{"name":"Faculty of Life Science and Technology, Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingqi","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yonghui","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayu","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xionggang","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7532-8981","authenticated-orcid":false,"given":"Sheng","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The First People\u2019s Hospital of Yunnan Province and the Affiliated Hospital of Kunming University of Science and Technology, Kunming, Yunnan, China"},{"name":"The Key Laboratory of Digital Orthopedics of Yunnan Province, The Clinical Medicine Center of Spinal and Spinal Cord Disorders of Yunnan Province, Kunming, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260605","doi-asserted-by":"crossref","first-page":"E406","DOI":"10.1097\/BRS.0000000000003284","article-title":"Prevalence of osteoporosis in patients undergoing lumbar fusion for lumbar degenerative diseases: a combination of DXA and hounsfield units.","volume":"45","author":"Zou","year":"2020","journal-title":"Spine"},{"key":"R2-20260605","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.2147\/CIA.S300873","article-title":"Characteristics of the DXA measurements in patients undergoing lumbar fusion for lumbar degenerative diseases: a retrospective analysis of over 1000 patients.","volume":"16","author":"Bao","year":"2021","journal-title":"Clin Interv Aging"},{"key":"R3-20260605","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1186\/s13018-023-04363-7","article-title":"Early outcomes of oblique lateral interbody fusion with posterior fixation versus posterior interbody fusion with fixation for treating adult degenerative scoliosis.","volume":"18","author":"Li","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R4-20260605","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1186\/s13018-024-04703-1","article-title":"Meta-analysis of the efficacy and safety of OLIF and TLIF in the treatment of degenerative lumbar spondylolisthesis.","volume":"19","author":"Shi","year":"2024","journal-title":"J Orthop Surg Res"},{"key":"R5-20260605","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1111\/os.12380","article-title":"Complications and prevention strategies of oblique lateral interbody fusion technique.","volume":"10","author":"Zeng","year":"2018","journal-title":"Orthop Surg"},{"key":"R6-20260605","doi-asserted-by":"crossref","first-page":"163","DOI":"10.14245\/ns.2143236.618","article-title":"Pearls and pitfalls of oblique lateral interbody fusion: a comprehensive narrative review.","volume":"19","author":"Kim","year":"2022","journal-title":"Neurospine"},{"key":"R7-20260605","doi-asserted-by":"crossref","first-page":"e220","DOI":"10.1016\/j.wneu.2022.01.107","article-title":"Does cage position affect the risk of cage subsidence after oblique lumbar interbody fusion in the osteoporotic lumbar spine: a finite element analysis.","volume":"161","author":"Qin","year":"2022","journal-title":"World Neurosurg"},{"key":"R8-20260605","doi-asserted-by":"crossref","first-page":"e483","DOI":"10.1016\/j.wneu.2020.08.203","article-title":"Biomechanical analysis of an interspinous process fixation device with in situ shortening capabilities: does spinous process compression improve segmental stability?","volume":"144","author":"Wagener","year":"2020","journal-title":"World Neurosurg"},{"key":"R9-20260605","doi-asserted-by":"crossref","first-page":"e70075","DOI":"10.1002\/jsp2.70075","article-title":"Impact of habitual flexion on bone formation after spinal fusion surgery: an in silico study.","volume":"8","author":"Ananth Swaminathan","year":"2025","journal-title":"JOR Spine"},{"key":"R10-20260605","doi-asserted-by":"crossref","first-page":"104169","DOI":"10.1016\/j.medengphy.2024.104169","article-title":"The effect of different fixation systems on oblique lumbar interbody fusion under vibration conditions.","volume":"128","author":"Zhang","year":"2024","journal-title":"Med Eng Phys"},{"key":"R11-20260605","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1186\/s12891-024-07204-8","article-title":"Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis.","volume":"25","author":"Xu","year":"2024","journal-title":"BMC Musculoskelet Disord"},{"key":"R12-20260605","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1097\/00007632-198909000-00015","article-title":"How does posture affect coupling in the lumbar spine?","volume":"14","author":"Panjabi","year":"1989","journal-title":"Spine (Phila Pa 1976)"},{"key":"R13-20260605","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1097\/00007632-198911000-00020","article-title":"Three-dimensional movements of the whole lumbar spine and lumbosacral joint.","volume":"14","author":"Yamamoto","year":"1989","journal-title":"Spine (Phila Pa 1976)"},{"key":"R14-20260605","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1002\/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D","article-title":"Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition.","volume":"251","author":"Wilke","year":"1998","journal-title":"Anat Rec"},{"key":"R15-20260605","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1016\/j.jbiomech.2009.03.048","article-title":"Applying a follower load delivers realistic results for simulating standing.","volume":"42","author":"Rohlmann","year":"2009","journal-title":"J Biomech"},{"key":"R16-20260605","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1186\/s12891-022-05553-w","article-title":"Biomechanical effects of an oblique lumbar interbody fusion combined with posterior augmentation: a finite element analysis.","volume":"23","author":"Huang","year":"2022","journal-title":"BMC Musculoskelet Disord"},{"key":"R17-20260605","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/10255842.2016.1193596","article-title":"Lumbar spine finite element model for healthy subjects: development and validation.","volume":"20","author":"Xu","year":"2017","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R18-20260605","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1097\/BRS.0000000000001650","article-title":"Perioperative complications in 155 patients who underwent oblique lateral interbody fusion surgery: perspectives and indications from a retrospective, multicenter survey.","volume":"42","author":"Abe","year":"2017","journal-title":"Spine"},{"key":"R19-20260605","doi-asserted-by":"crossref","first-page":"16","DOI":"10.21037\/atm-20-2159","article-title":"Clinical results and complications associated with oblique lumbar interbody fusion technique.","volume":"9","author":"Cheng","year":"2021","journal-title":"Ann Transl Med"},{"key":"R20-20260605","doi-asserted-by":"crossref","first-page":"e435","DOI":"10.1016\/j.wneu.2021.06.134","article-title":"Can indirect decompression reduce adjacent segment degeneration and the associated reoperation rate after lumbar interbody fusion? A systemic review and meta-analysis.","volume":"153","author":"Chang","year":"2021","journal-title":"World Neurosurg"},{"key":"R21-20260605","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1186\/s13018-023-04262-x","article-title":"Oblique lateral interbody fusion combined with unilateral versus bilateral posterior fixation in patients with osteoporosis.","volume":"18","author":"Ma","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R22-20260605","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.spinee.2018.09.002","article-title":"Biomechanical evaluation of lumbar lateral interbody fusion for the treatment of adjacent segment disease.","volume":"19","author":"Shasti","year":"2019","journal-title":"Spine J"},{"key":"R23-20260605","doi-asserted-by":"crossref","first-page":"89","DOI":"10.4184\/asj.2012.6.2.89","article-title":"Complications and morbidities of mini-open anterior retroperitoneal lumbar interbody fusion: oblique lumbar interbody fusion in 179 patients.","volume":"6","author":"Silvestre","year":"2012","journal-title":"Asian Spine J"},{"key":"R24-20260605","doi-asserted-by":"crossref","first-page":"1","DOI":"10.22603\/ssrr.2020-0086","article-title":"Technical and conceptual review on the L5-S1 oblique lateral interbody fusion surgery (OLIF51).","volume":"5","author":"Orita","year":"2020","journal-title":"Spine Surg Relat Res"},{"key":"R25-20260605","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jos.2022.10.022","article-title":"Risk factors for nonunion in oblique lateral interbody fusion.","volume":"29","author":"Chung","year":"2024","journal-title":"J Orthop Sci"},{"key":"R26-20260605","doi-asserted-by":"crossref","first-page":"e0304473","DOI":"10.1371\/journal.pone.0304473","article-title":"Risk factors affecting spinal fusion: a meta-analysis of 39 cohort studies.","volume":"19","author":"Yang","year":"2024","journal-title":"PLoS One"},{"key":"R27-20260605","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/BSD.0b013e318211fc6b","article-title":"Oblique lumbar interbody fixation: a biomechanical study in human spines.","volume":"25","author":"St Clair","year":"2012","journal-title":"J Spinal Disord Tech"},{"key":"R28-20260605","doi-asserted-by":"crossref","first-page":"106","DOI":"10.31616\/asj.2019.0024","article-title":"Incidences and risk factors for postoperative non-union after posterior lumbar interbody fusion with closed-box titanium spacers.","volume":"14","author":"Konomi","year":"2020","journal-title":"Asian Spine J"},{"key":"R29-20260605","doi-asserted-by":"crossref","first-page":"110","DOI":"10.3171\/2013.4.SPINE12319","article-title":"Radiographic and clinical evaluation of cage subsidence after stand-alone lateral interbody fusion.","volume":"19","author":"Marchi","year":"2013","journal-title":"J Neurosurg Spine"},{"key":"R30-20260605","doi-asserted-by":"crossref","first-page":"9016219","DOI":"10.1155\/2020\/9016219","article-title":"Oblique lumbar interbody fusion with stand-alone cages for the treatment of degenerative lumbar spondylolisthesis: a retrospective study with 1-year follow-up.","volume":"2020","author":"Huo","year":"2020","journal-title":"Pain Res Manag"},{"key":"R31-20260605","doi-asserted-by":"crossref","first-page":"e285","DOI":"10.1016\/j.wneu.2021.08.049","article-title":"Biomechanical evaluation of stand-alone oblique lateral lumbar interbody fusion under 3 different bone mineral density conditions: a finite element analysis.","volume":"155","author":"Wang","year":"2021","journal-title":"World Neurosurg"},{"key":"R32-20260605","doi-asserted-by":"crossref","first-page":"871","DOI":"10.21037\/atm-22-3456","article-title":"Biomechanical evaluation of a novel anatomical plate for oblique lumbar interbody fusion compared with various fixations: a finite element analysis.","volume":"10","author":"Huang","year":"2022","journal-title":"Ann Transl Med"},{"key":"R33-20260605","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1186\/s12891-022-05150-x","article-title":"Oblique lateral interbody fusion combined with different internal fixations for the treatment of degenerative lumbar spine disease: a finite element analysis.","volume":"23","author":"Zhang","year":"2022","journal-title":"BMC Musculoskelet Disord"},{"key":"R34-20260605","doi-asserted-by":"crossref","first-page":"381","DOI":"10.3171\/2010.3.SPINE09590","article-title":"Examining risk factors for posterior migration of fusion cages following transforaminal lumbar interbody fusion: a possible limitation of unilateral pedicle screw fixation.","volume":"13","author":"Aoki","year":"2010","journal-title":"J Neurosurg Spine"},{"key":"R35-20260605","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1186\/s12891-020-03192-7","article-title":"Standalone oblique lateral interbody fusion vs. combined with percutaneous pedicle screw in spondylolisthesis.","volume":"21","author":"He","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"R36-20260605","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1186\/s12891-023-06985-8","article-title":"Clinical, radiographic and fusion comparison of oblique lumbar interbody fusion (OLIF) stand-alone and OLIF with posterior pedicle screw fixation in patients with degenerative spondylolisthesis.","volume":"24","author":"Zhao","year":"2023","journal-title":"BMC Musculoskelet Disord"},{"key":"R37-20260605","doi-asserted-by":"crossref","first-page":"7463","DOI":"10.3390\/jcm12237463","article-title":"The fate of pre-existing L5-S1 degeneration following oblique lumbar interbody fusion of L4-L5 and Above.","volume":"12","author":"Kang","year":"2023","journal-title":"J Clin Med"},{"key":"R38-20260605","doi-asserted-by":"crossref","first-page":"2909","DOI":"10.2147\/JPR.S417319","article-title":"Instrumented posterior arthrodesis of the lumbar spine: prospective study evaluating fusion outcomes in patients receiving an interspinous fixation device for the treatment of degenerative spine diseases.","volume":"16","author":"Skoblar","year":"2023","journal-title":"J Pain Res"},{"key":"R39-20260605","first-page":"1325","article-title":"Biomechanical characteristics of a novel interspinous distraction fusion device BacFuse for the repair of lumbar degenerative disease.","volume":"28","author":"Chen","year":"2024","journal-title":"Zhongguo Zuzhi Gongcheng Yanjiu"},{"key":"R40-20260605","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1186\/s12891-022-05543-y","article-title":"Biomechanical comparison of different interspinous process devices in the treatment of lumbar spinal stenosis: a finite element analysis.","volume":"23","author":"Liu","year":"2022","journal-title":"BMC Musculoskelet Disord"},{"issue":"26 Suppl","key":"R41-20260605","doi-asserted-by":"crossref","first-page":"S361","DOI":"10.1097\/BRS.0b013e318202308b","article-title":"Biomechanical analysis and review of lateral lumbar fusion constructs.","volume":"35","author":"Cappuccino","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R42-20260605","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1080\/10255842.2020.1745784","article-title":"The biomechanical study of a modified lumbar interbody fusion-crenel lateral interbody fusion (CLIF): a three-dimensional finite-element analysis.","volume":"23","author":"Chen","year":"2020","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R43-20260605","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1186\/s13018-023-04461-6","article-title":"Biomechanical differences between two different shapes of oblique lumbar interbody fusion cages on whether to add posterior internal fixation system: a finite element analysis.","volume":"18","author":"Liu","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R44-20260605","doi-asserted-by":"crossref","first-page":"1981","DOI":"10.1177\/21925682211067210","article-title":"Subsidence of interbody cage following oblique lateral interbody fusion: an analysis and potential risk factors.","volume":"13","author":"Kotheeranurak","year":"2023","journal-title":"Global Spine J"},{"key":"R45-20260605","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1186\/s13018-022-03143-z","article-title":"Biomechanical study of oblique lumbar interbody fusion (OLIF) augmented with different types of instrumentation: a finite element analysis.","volume":"17","author":"Cai","year":"2022","journal-title":"J Orthop Surg Res"},{"key":"R46-20260605","doi-asserted-by":"crossref","first-page":"e890","DOI":"10.1016\/j.wneu.2019.06.074","article-title":"Comparison of biomechanical performance among posterolateral fusion and transforaminal, extreme, and oblique lumbar interbody fusion: a finite element analysis.","volume":"129","author":"Lu","year":"2019","journal-title":"World Neurosurg"},{"key":"R47-20260605","doi-asserted-by":"crossref","first-page":"104122","DOI":"10.1016\/j.compbiomed.2020.104122","article-title":"Does oblique lumbar interbody fusion promote adjacent degeneration in degenerative disc disease: a finite element analysis.","volume":"128","author":"Du","year":"2021","journal-title":"Comput Biol Med"},{"key":"R48-20260605","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1186\/s13018-023-03838-x","article-title":"Fixation-induced surgical segment\u2019s high stiffness and the damage of posterior structures together trigger a higher risk of adjacent segment disease in patients with lumbar interbody fusion operations.","volume":"18","author":"Cai","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R49-20260605","doi-asserted-by":"crossref","first-page":"e920","DOI":"10.1016\/j.wneu.2019.11.035","article-title":"Unilateral versus bilateral percutaneous pedicle screw fixation in oblique lumbar interbody fusion.","volume":"134","author":"Wen","year":"2020","journal-title":"World Neurosurg"},{"key":"R50-20260605","doi-asserted-by":"crossref","first-page":"643","DOI":"10.3171\/2017.3.SPINE161169","article-title":"Biomechanical effects of hybrid stabilization on the risk of proximal adjacent-segment degeneration following lumbar spinal fusion using an interspinous device or a pedicle screw-based dynamic fixator.","volume":"27","author":"Lee","year":"2017","journal-title":"J Neurosurg Spine"},{"key":"R51-20260605","doi-asserted-by":"crossref","first-page":"e3498","DOI":"10.1002\/cnm.3498","article-title":"Biomechanical analysis of lumbar fusion with proximal interspinous process device implantation.","volume":"37","author":"Shen","year":"2021","journal-title":"Int J Numer Method Biomed Eng"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000048346","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T16:00:40Z","timestamp":1780675240000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000048346"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,17]]},"references-count":51,"journal-issue":{"issue":"16","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000048346","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,17]]},"assertion":[{"value":"2025-05-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}