{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T10:39:23Z","timestamp":1791628763025,"version":"4.3.4"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"18","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5,1]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>This study aimed to evaluate an auto-verification system for serological markers of infectious diseases in a clinical laboratory, with the goal of ensuring reliable results while shortening the turnaround time for reports, reducing the need for human resources, and improving work efficiency. Based on the guidelines and clinical requirements, personalized auto-verification rules were established. Then, the serological marker results of 144,927 samples (including hepatitis B, hepatitis C, Treponema pallidum, and human immunodeficiency virus) were used for verification, and the performance of the auto-verification system was evaluated. The auto-verification system enabled our laboratory to shorten the turnaround time by 21.13% (from 369.54 minutes to 291.47 minutes) while increasing the sample volume. The pass rate, sensitivity, specificity, false positive rate, and false negative rate of the auto-verification system were 54.81%, 100%, 54.99%, 45.01% and 0%, respectively. Further analysis of the reasons for the failure of auto-verification revealed that a portion of the samples were blocked due to technical issues with the laboratory information system. Further improvements are needed in the future. Establishing an appropriate auto-verification system based on the actual situation of the laboratory is an important means to ensure medical safety, while improving the efficiency of the clinical laboratory and reducing labor costs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000048596","type":"journal-article","created":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T10:00:32Z","timestamp":1777629632000},"page":"e48596","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Establishment of an intelligent auto-verification system for infectious serological markers in a clinical laboratory from West China"],"prefix":"10.1097","volume":"105","author":[{"given":"Yu","family":"Gou","sequence":"first","affiliation":[{"name":"Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China"},{"name":"Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Ministry of Education, Chengdu, Sichuan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifei","family":"Duan","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China"},{"name":"Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Ministry of Education, Chengdu, Sichuan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China"},{"name":"Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Ministry of Education, Chengdu, Sichuan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengxiang","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China"},{"name":"Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Ministry of Education, Chengdu, Sichuan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinyi","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China"},{"name":"Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Ministry of Education, Chengdu, Sichuan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leiwen","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China"},{"name":"Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Ministry of Education, Chengdu, Sichuan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260622","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1093\/labmed\/lmy031","article-title":"Improving laboratory processes with total laboratory automation.","volume":"50","author":"Yu","year":"2019","journal-title":"Lab. Med"},{"key":"R2-20260622","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1093\/clinchem\/hvab242","article-title":"Current state of laboratory automation in clinical microbiology laboratory.","volume":"68","author":"Antonios","year":"2021","journal-title":"Clin Chem"},{"key":"R3-20260622","doi-asserted-by":"crossref","first-page":"e22877","DOI":"10.1002\/jcla.22877","article-title":"Establishing and validating of an laboratory information system-based auto-verification system for biochemical test results in cancer patients.","volume":"33","author":"Yan","year":"2019","journal-title":"J Clin Lab Anal"},{"key":"R4-20260622","doi-asserted-by":"crossref","first-page":"110969","DOI":"10.1016\/j.clinbiochem.2025.110969","article-title":"Implementation and validation of an intelligent auto-verification system in a coagulation testing automatic line.","volume":"139","author":"Liu","year":"2025","journal-title":"Clin Biochem"},{"key":"R5-20260622","doi-asserted-by":"crossref","first-page":"1835","DOI":"10.1007\/s00277-019-03656-4","article-title":"Establishing and evaluating an auto-verification system of thalassemia gene detection results.","volume":"98","author":"Lin","year":"2019","journal-title":"Ann Hematol"},{"key":"R6-20260622","doi-asserted-by":"crossref","first-page":"1334897","DOI":"10.3389\/fmicb.2024.1334897","article-title":"Benefit analysis of the auto-verification system of intelligent inspection for microorganisms.","volume":"15","author":"Ou","year":"2024","journal-title":"Front Microbiol"},{"key":"R7-20260622","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.clinbiochem.2021.03.018","article-title":"A model to establish autoverification in the clinical laboratory.","volume":"93","author":"Topcu","year":"2021","journal-title":"Clin Biochem"},{"key":"R8-20260622","first-page":"030704","article-title":"Designing and validating an autoverification system of biochemical test results in Hatay Mustafa Kemal University, clinical laboratory.","volume":"32","author":"G\u00fcl","year":"2022","journal-title":"Biochem Med (Zagreb)"},{"key":"R11-20260622","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1515\/cclm-2012-0659","article-title":"Current status of verification practices in clinical biochemistry in Spain.","volume":"51","author":"G\u00f3mez-Rioja","year":"2013","journal-title":"Clin Chem Lab Med"},{"key":"R12-20260622","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.clinbiochem.2019.08.002","article-title":"Autoverification of test results in the core clinical laboratory.","volume":"73","author":"Randell","year":"2019","journal-title":"Clin Biochem"},{"key":"R13-20260622","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1186\/s12911-019-0848-2","article-title":"Design and evaluation of a LIS-based autoverification system for coagulation assays in a core clinical laboratory.","volume":"19","author":"Wang","year":"2019","journal-title":"BMC Med Inform Decis Mak"},{"key":"R14-20260622","first-page":"873","article-title":"A comprehensive prevention programs on AIDS, HBV and syphilis among pregnant women and couples experienced premarital medical examination.","volume":"31","author":"Gui","year":"2010","journal-title":"Zhonghua Liu Xing Bing Xue Za Zhi"},{"key":"R15-20260622","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.3390\/vaccines13121216","article-title":"Transient hepatitis B surface antigenemia following immunization with the adjuvanted hepatitis B vaccine Fendrix\u00ae.","volume":"13","author":"Fern\u00e1ndez-Espinilla","year":"2025","journal-title":"Vaccines (Basel)"},{"key":"R16-20260622","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/S0140-6736(09)60207-5","article-title":"Hepatitis B virus infection.","volume":"373","author":"Liaw","year":"2009","journal-title":"Lancet"},{"key":"R17-20260622","doi-asserted-by":"crossref","first-page":"1","DOI":"10.15585\/mmwr.rr7004a1","article-title":"Sexually transmitted infections treatment guidelines, 2021.","volume":"70","author":"Workowski","year":"2021","journal-title":"MMWR Recomm Rep"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000048596","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T09:01:33Z","timestamp":1782118893000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000048596"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,1]]},"references-count":15,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000048596","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,1]]},"assertion":[{"value":"2026-02-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}