{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T14:27:11Z","timestamp":1788532031846,"version":"build-2803163510"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"20","license":[{"start":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T00:00:00Z","timestamp":1778803200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Tianjin Key Medical Discipline Construction Project","award":["TJYXZDXK-3-035C"],"award-info":[{"award-number":["TJYXZDXK-3-035C"]}]},{"name":"Tianjin Binhai New Area Health Commission Science","award":["2023BWKZ004"],"award-info":[{"award-number":["2023BWKZ004"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5,15]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      Quantitative myocardial blood flow (MBF) assessment using cardiac-dedicated cadmium-zinc-telluride (CZT) single photon emission computed tomography (SPECT) has emerged as a promising noninvasive approach for evaluating both macrovascular and microvascular coronary function. However, the reliability and comparability of MBF measurements are substantially influenced by variations in post-processing methodologies, including the application of attenuation correction (AC) and scatter correction (SC) techniques. Despite the increasing clinical adoption of CZT-SPECT for absolute perfusion quantification, systematic evaluations comparing different post-processing strategies remain limited. This study aimed to evaluate the impact of various post-processing approaches on absolute quantitative MBF measurements obtained through CZT-SPECT, with particular focus on AC and SC methodologies. Seventy patients who underwent dynamic CZT-SPECT myocardial perfusion imaging were retrospectively included, comprising 35 Tc-99m-methoxyisobutylisonitrile patients and 35 Tc-99m-tetrofosmin patients. Each raw imaging dataset was independently reprocessed using Corridor 4DM under 3 correction strategies \u2013 no correction, attenuation correction, and attenuation + scatter correction (ACSC) \u2013 as well as using MyoFlowQ. Repeated-measures analysis of variance or Friedman tests with Holm-adjusted pairwise comparisons were used to compare the Corridor 4DM processing strategies, and agreement between Corridor 4DM with ACSC and MyoFlowQ was assessed using Bland\u2013Altman analysis. Rest and stress MBF differed significantly across the Corridor 4DM processing strategies (both\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.001). Myocardial flow reserve (MFR) differences were tracer-dependent: no overall difference was observed in global left ventricular values in the Tc-99m-methoxyisobutylisonitrile cohort (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.121), whereas a significant difference was observed in the Tc-99m-tetrofosmin cohort (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.002). Compared with Corridor 4DM using ACSC, MyoFlowQ yielded higher stress MBF and MFR values (bias, 1.19\u20131.31 mL\u00b7g\n                      <jats:sup>\u22121<\/jats:sup>\n                      \u00b7min\n                      <jats:sup>\u22121<\/jats:sup>\n                      ; 95% limits of agreement, \u20130.30 to 2.68), with moderate inter-software correlation (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      \u2005=\u20050.44\u20130.59,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.01). Post-processing methodology significantly influenced absolute MBF quantification in CZT-SPECT imaging. Within Corridor 4DM, correction strategies affected MBF estimates, and MyoFlowQ yielded higher stress MBF and MFR values than Corridor 4DM using ACSC, indicating that these post-processing approaches are not directly interchangeable.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000048852","type":"journal-article","created":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T02:01:22Z","timestamp":1778896882000},"page":"e48852","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Assessment of the impact of post-processing approaches on absolute myocardial blood flow quantification using cardiac-dedicated CZT-SPECT: A retrospective observational study"],"prefix":"10.1097","volume":"105","author":[{"given":"Yudong","family":"Shi","sequence":"first","affiliation":[{"name":"Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9810-5406","authenticated-orcid":false,"given":"Fukai","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zekun","family":"Pang","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiao","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2585-4753","authenticated-orcid":false,"given":"Jianming","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260904","first-page":"e4","article-title":"2021 ACC\/AHA\/SCAI guideline for coronary artery revascularization: executive summary: a report of the American College of Cardiology\/American Heart Association joint committee on clinical practice guidelines.","volume":"145","author":"Lawton","year":"2022","journal-title":"Circulation"},{"key":"R2-20260904","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s12350-017-1110-x","article-title":"Clinical quantification of myocardial blood flow using PET: joint position paper of the SNMMI cardiovascular council and the ASNC.","volume":"25","author":"Murthy","year":"2018","journal-title":"J Nucl Cardiol"},{"key":"R3-20260904","doi-asserted-by":"crossref","first-page":"2827","DOI":"10.1007\/s12350-020-02129-w","article-title":"Quantification of myocardial perfusion reserve by CZT-SPECT: a head to head comparison with 82Rubidium PET imaging.","volume":"28","author":"Acampa","year":"2021","journal-title":"J Nucl Cardiol"},{"key":"R4-20260904","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1007\/s00259-018-3958-7","article-title":"First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study.","volume":"45","author":"Agostini","year":"2018","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R5-20260904","doi-asserted-by":"crossref","first-page":"2294","DOI":"10.1007\/s00259-014-2881-9","article-title":"Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT\/CT to enhance detection of coronary artery disease.","volume":"41","author":"Hsu","year":"2014","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R6-20260904","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1007\/s12350-015-0320-3","article-title":"Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: method and validation.","volume":"24","author":"Shrestha","year":"2017","journal-title":"J Nucl Cardiol"},{"key":"R7-20260904","doi-asserted-by":"crossref","first-page":"2560","DOI":"10.1007\/s12350-020-02075-7","article-title":"Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow.","volume":"28","author":"Bailly","year":"2021","journal-title":"J Nucl Cardiol"},{"key":"R8-20260904","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.diii.2023.02.001","article-title":"Myocardial blood flow evaluation with dynamic cadmium-zinc-telluride single-photon emission computed tomography: bright and dark sides.","volume":"104","author":"D\u2019Antonio","year":"2023","journal-title":"Diagn Interv Imaging"},{"key":"R9-20260904","doi-asserted-by":"crossref","first-page":"56","DOI":"10.21037\/cdt-20-728","article-title":"Diagnostic efficiency of quantification of myocardial blood flow and coronary flow reserve with CZT dynamic SPECT imaging for patients with suspected coronary artery disease: a comparative study with traditional semi-quantitative evaluation.","volume":"11","author":"Wang","year":"2021","journal-title":"Cardiovasc Diagn Ther"},{"key":"R10-20260904","doi-asserted-by":"crossref","first-page":"2006","DOI":"10.1007\/s12350-022-03165-4","article-title":"Measuring myocardial blood flow using dynamic myocardial perfusion SPECT: artifacts and pitfalls.","volume":"30","author":"Mallet","year":"2023","journal-title":"J Nucl Cardiol"},{"key":"R11-20260904","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1007\/s10554-020-01962-x","article-title":"Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease.","volume":"37","author":"Pang","year":"2021","journal-title":"Int J Cardiovasc Imaging"},{"key":"R12-20260904","doi-asserted-by":"crossref","first-page":"101825","DOI":"10.1016\/j.nuclcard.2024.101825","article-title":"Feasibility of myocardial blood flow quantification to detect flow-limited coronary artery disease with a one-day rest\/stress continuous rapid imaging protocol on cardiac-dedicated cadmium zinc telluride single photon emission computed tomography.","volume":"34","author":"Wang","year":"2024","journal-title":"J Nucl Cardiol"},{"key":"R13-20260904","doi-asserted-by":"crossref","first-page":"1332","DOI":"10.1007\/s12350-016-0513-4","article-title":"Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation.","volume":"24","author":"Wang","year":"2017","journal-title":"J Nucl Cardiol"},{"key":"R14-20260904","doi-asserted-by":"crossref","first-page":"e617","DOI":"10.1097\/RLU.0000000000002709","article-title":"Added value of myocardial blood flow quantification and calcium scoring during CZT SPECT myocardial perfusion imaging for coronary artery disease screening.","volume":"44","author":"Bailly","year":"2019","journal-title":"Clin Nucl Med"},{"key":"R15-20260904","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.nuclcard.2004.04.005","article-title":"Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease.","volume":"11","author":"Parkash","year":"2004","journal-title":"J Nucl Cardiol"},{"key":"R16-20260904","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.3390\/jcm13051271","article-title":"The influence of kinetic models and attenuation correction on cadmium-zinc-telluride single-photon emission computed tomography (CZT SPECT)-derived myocardial blood flow and reserve: correlation with invasive angiography data.","volume":"13","author":"Mochula","year":"2024","journal-title":"J Clin Med"},{"key":"R17-20260904","doi-asserted-by":"crossref","first-page":"613","DOI":"10.3390\/diagnostics15050613","article-title":"Inter-software reproducibility of quantitative values of myocardial blood flow and coronary flow reserve acquired by [13N]NH3 MPI PET\/CT and the effect of motion correction tools.","volume":"15","author":"Mendoza-Iba\u00f1ez","year":"2025","journal-title":"Diagnostics (Basel)"},{"key":"R18-20260904","doi-asserted-by":"crossref","first-page":"3137","DOI":"10.1007\/s12350-021-02620-y","article-title":"The current status of CZT SPECT myocardial blood flow and reserve assessment: tips and tricks.","volume":"29","author":"Zavadovsky","year":"2022","journal-title":"J Nucl Cardiol"},{"key":"R19-20260904","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1007\/s12350-019-01854-1","article-title":"Quantification of myocardial blood flow by CZT-SPECT with motion correction and comparison with 15O-water PET.","volume":"28","author":"Otaki","year":"2021","journal-title":"J Nucl Cardiol"},{"key":"R20-20260904","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1007\/s12350-014-9971-8","article-title":"Feasibility and operator variability of myocardial blood flow and reserve measurements with 99mTc-sestamibi quantitative dynamic SPECT\/CT imaging.","volume":"21","author":"Klein","year":"2014","journal-title":"J Nucl Cardiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000048852","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T14:01:27Z","timestamp":1788530487000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000048852"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,15]]},"references-count":20,"journal-issue":{"issue":"20","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000048852","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,15]]},"assertion":[{"value":"2025-07-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}