{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T14:14:26Z","timestamp":1783779266108,"version":"3.55.0"},"reference-count":78,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"23","license":[{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,6,5]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Total Hip Arthroplasty (THA) is a well-established intervention that improves the quality of life in patients with severe hip arthritis by relieving pain and restoring function. Long-term success of THA is heavily influenced by the choice of prosthetic interfaces, particularly the bearing surfaces. However, the effects of patient age and follow-up duration on the outcomes of different interfaces remain underexplored.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This study performed a systematic review and network meta-analysis, gathering randomized controlled trials (RCTs) from PubMed, Embase, Cochrane Library, and Web of Science. Included studies compared outcomes of various prosthetic interfaces, focusing on patient age (\u226460 years and\u2005&gt;\u200560 years) and follow-up duration. Quality was assessed using the Cochrane risk of bias tool.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Fifty-nine RCTs were included. For younger patients (\u226460 years), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and highly cross-linked polyethylene (CoXLPE) interfaces showed lower revision rates and superior radiographic outcomes compared to metal-on-metal (MoM) and metal-on-polyethylene (MoP). Older patients (&gt;60 years) saw better outcomes with metal interfaces, particularly MoP, in short- and mid-term follow-ups. Across all ages, CoXLPE demonstrated excellent durability and reduced revision rates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This meta-analysis highlights the importance of age-specific prosthetic selection in THA. Younger patients benefit from CoC and CoXLPE due to superior wear resistance, while older patients may achieve better results with MoP. Further long-term studies are needed to validate these findings and reduce study heterogeneity.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000049085","type":"journal-article","created":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T04:01:23Z","timestamp":1780718483000},"page":"e49085","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comprehensive outcomes of different prosthetic interfaces in total hip arthroplasty: A network meta-analysis and systematic review based on age and follow-up periods"],"prefix":"10.1097","volume":"105","author":[{"given":"Qian","family":"Liang","sequence":"first","affiliation":[{"name":"College of Mathematics, Jilin University, Changchun, Jilin Province, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaxin","family":"Li","sequence":"additional","affiliation":[{"name":"College of Mathematics, Jilin University, Changchun, Jilin Province, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenlai","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, The Second Hospital of Jilin University, Changchun, Jilin Province, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Di","family":"You","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, China-Japan Union Hospital of Jilin University, Changchun, Jilin Province, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu","family":"Qin","sequence":"additional","affiliation":[{"name":"Shanxi Key Laboratory of Cryptography and Data Security & School of Mathematical Sciences, Shanxi Normal University, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the Second Hospital of Jilin University, Changchun, Jilin Province, People\u2019s Republic of China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260711","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/S0140-6736(18)32531-5","article-title":"How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up.","volume":"393","author":"Evans","year":"2019","journal-title":"Lancet"},{"key":"R2-20260711","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","article-title":"The operation of the century: total hip replacement.","volume":"370","author":"Learmonth","year":"2007","journal-title":"Lancet"},{"key":"R3-20260711","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/j.arth.2022.10.016","article-title":"Comparisons of different bearing surfaces in cementless total hip arthroplasty: a systematic review and bayesian network analysis.","volume":"38","author":"Zheng","year":"2023","journal-title":"J Arthroplasty"},{"key":"R4-20260711","doi-asserted-by":"crossref","first-page":"448","DOI":"10.2106\/JBJS.M.00164","article-title":"Metal ion levels after metal-on-metal total hip arthroplasty: a five-year, prospective randomized trial.","volume":"96","author":"Engh","year":"2014","journal-title":"J Bone Joint Surg Am"},{"key":"R5-20260711","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1302\/0301-620X.95B7.31067","article-title":"High rate of revision and a high incidence of radiolucent lines around Metasul metal-on-metal total hip replacements: results from a randomised controlled trial of three bearings after seven years.","volume":"95-B","author":"Bjorgul","year":"2013","journal-title":"Bone Joint J"},{"key":"R6-20260711","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1302\/0301-620X.93B12.27533","article-title":"What advantage is there to be gained using large modular metal-on-metal bearings in routine primary hip replacement? A preliminary report of a prospective randomised controlled trial.","volume":"93","author":"Malviya","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"R7-20260711","doi-asserted-by":"crossref","first-page":"e0066","DOI":"10.2106\/JBJS.OA.19.00066","article-title":"Wear rates of XLPE Nearly 50% lower than previously thought after adjusting for initial creep: an RCT comparing 4 bearing combinations.","volume":"5","author":"Khoshbin","year":"2020","journal-title":"JB JS Open Access"},{"key":"R8-20260711","doi-asserted-by":"crossref","first-page":"102744","DOI":"10.1016\/j.otsr.2020.102744","article-title":"Ceramic-on-ceramic total hip arthroplasty is superior to metal-on-conventional polyethylene at 20-year follow-up: a randomised clinical trial.","volume":"107","author":"Vendittoli","year":"2021","journal-title":"Orthop Traumatol Surg Res"},{"key":"R9-20260711","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.4103\/0366-6999.156136","article-title":"Ceramic on ceramic or ceramic-on-polyethylene for total hip arthroplasty: a systemic review and meta-analysis of prospective randomized studies.","volume":"128","author":"Dong","year":"2015","journal-title":"Chin Med J (Engl)"},{"key":"R10-20260711","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1186\/s12891-021-04950-x","article-title":"Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up.","volume":"22","author":"Giuseppe","year":"2022","journal-title":"BMC Musculoskelet Disord"},{"key":"R11-20260711","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1016\/j.arth.2017.11.066","article-title":"The ideal total hip replacement bearing surface in the young patient: a prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene: 15-year follow-up.","volume":"33","author":"Atrey","year":"2018","journal-title":"J Arthroplasty"},{"key":"R12-20260711","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/j.arth.2009.01.013","article-title":"Prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene bearings in total hip arthroplasty.","volume":"25","author":"Lewis","year":"2010","journal-title":"J Arthroplasty"},{"key":"R13-20260711","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.2106\/JBJS.RVW.17.00077","article-title":"The impact of advanced age on the outcomes of primary total hip and knee arthroplasty for osteoarthritis: a systematic review.","volume":"6","author":"Murphy","year":"2018","journal-title":"JBJS Rev"},{"key":"R14-20260711","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1186\/s13643-021-01626-4","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.","volume":"10","author":"Page","year":"2021","journal-title":"Syst Rev"},{"key":"R15-20260711","doi-asserted-by":"crossref","first-page":"j4008","DOI":"10.1136\/bmj.j4008","article-title":"AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both.","volume":"358","author":"Shea","year":"2017","journal-title":"BMJ"},{"key":"R16-20260711","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.arth.2021.08.033","article-title":"Does a monoblock acetabular component with a ceramic liner cause more pelvic bone loss than a conventional modular cementless acetabular component? a 2-year randomized clinical trial.","volume":"37","author":"Fischman","year":"2022","journal-title":"J Arthroplasty"},{"key":"R17-20260711","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.arth.2014.04.046","article-title":"A randomized controlled trial comparing Oxinium and cobalt-chrome on standard and cross-linked polyethylene.","volume":"29","author":"Morison","year":"2014","journal-title":"J Arthroplasty"},{"key":"R18-20260711","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.arth.2012.07.027","article-title":"A randomized trial of ceramic-on-ceramic bearing versus ceramic-on-crossfire-polyethylene bearing in total hip arthroplasty: five-year outcomes.","volume":"28","author":"Beaupre","year":"2013","journal-title":"J Arthroplasty"},{"key":"R19-20260711","doi-asserted-by":"crossref","first-page":"e1307","DOI":"10.3928\/01477447-20120822-14","article-title":"Large-diameter Delta ceramic-on-ceramic versus common-sized ceramic-on-polyethylene bearings in THA.","volume":"35","author":"Cai","year":"2012","journal-title":"Orthopedics"},{"key":"R20-20260711","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.arth.2011.04.032","article-title":"Comparison of surgical outcomes and implant wear between ceramic-ceramic and ceramic-polyethylene articulations in total hip arthroplasty.","volume":"26","author":"Amanatullah","year":"2011","journal-title":"J Arthroplasty"},{"key":"R21-20260711","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s11999-009-1091-4","article-title":"THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.","volume":"468","author":"Hamilton","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"R22-20260711","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1007\/s00264-009-0899-6","article-title":"Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study.","volume":"34","author":"Bascarevic","year":"2010","journal-title":"Int Orthop"},{"key":"R23-20260711","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1302\/0301-620X.89B11.19543","article-title":"A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial.","volume":"89","author":"Triclot","year":"2007","journal-title":"J Bone Joint Surg Br"},{"issue":"Suppl 3","key":"R24-20260711","first-page":"116","article-title":"Use of an alumina-on-alumina bearing system in total hip arthroplasty for osteonecrosis of the hip.","volume":"88","author":"Seyler","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R25-20260711","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/01.blo.0000162995.50971.39","article-title":"Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study.","volume":"436","author":"D\u2019Antonio","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"R26-20260711","first-page":"171","article-title":"Alternative bearing surfaces: alumina ceramic bearings for total hip arthroplasty.","volume":"54","author":"Capello","year":"2005","journal-title":"Instr Course Lect"},{"key":"R27-20260711","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1177\/112070000501500301","article-title":"Ceramic-on-ceramic versus ceramic-on-polyethylene bearings in total hip arthroplasty: results of a multicenter prospective randomized study and update of modern ceramic total hip trials in the United States.","volume":"15","author":"Bal","year":"2005","journal-title":"HIP Int"},{"key":"R28-20260711","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.arth.2004.06.021","article-title":"Three- to six-year results with the Ultima metal-on-metal hip articulation for primary total hip arthroplasty.","volume":"19","author":"Jacobs","year":"2004","journal-title":"J Arthroplasty"},{"key":"R29-20260711","first-page":"157","article-title":"Ceramic\/ceramic total hip replacement: the American experience with stryker implants.","volume":"90-B","author":"Bierbaum","year":"2008","journal-title":"Orthop Procs"},{"key":"R30-20260711","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1054\/arth.2002.32183","article-title":"New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty.","volume":"17","author":"D\u2019Antonio","year":"2002","journal-title":"J Arthroplasty"},{"key":"R31-20260711","doi-asserted-by":"crossref","first-page":"96","DOI":"10.5301\/hipint.5000428","article-title":"A randomised, controlled clinical study on total hip arthroplasty using 4 different bearings: results after 10 years.","volume":"27","author":"Borgwardt","year":"2017","journal-title":"Hip Int"},{"key":"R32-20260711","doi-asserted-by":"crossref","first-page":"1604","DOI":"10.1302\/0301-620X.94B12.28060","article-title":"Cemented polyethylene and cementless porous-coated acetabular components have similar outcomes at a mean of seven years after total hip replacement: a prospective randomised study.","volume":"94","author":"Angadi","year":"2012","journal-title":"J Bone Joint Surg Br"},{"key":"R33-20260711","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1177\/11207000211064975","article-title":"Higher risk of 2-year cup revision of ceramic-on-ceramic versus ceramic-on-polyethylene bearing: analysis of 33,454 primary press-fit total hip arthroplasties registered in the Dutch Arthroplasty Register (LROI).","volume":"33","author":"Van Loon","year":"2023","journal-title":"Hip Int"},{"key":"R34-20260711","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1302\/0301-620X.97B11.36137","article-title":"Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years: a randomised trial of 120 hips using radiostereometric analysis.","volume":"97-B","author":"Jonsson","year":"2015","journal-title":"Bone Joint J"},{"key":"R35-20260711","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1302\/0301-620X.97B7.35285","article-title":"Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.","volume":"97-B","author":"Jassim","year":"2015","journal-title":"Bone Joint J"},{"key":"R36-20260711","doi-asserted-by":"crossref","first-page":"136","DOI":"10.5301\/hipint.5000087","article-title":"Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results.","volume":"24","author":"Zijlstra","year":"2014","journal-title":"Hip Int"},{"key":"R37-20260711","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1302\/2046-3758.28.2000173","article-title":"Peri-acetabular bone mineral densityin total hip replacement.","volume":"2","author":"Gauthier","year":"2013","journal-title":"Bone Joint Res"},{"key":"R38-20260711","doi-asserted-by":"crossref","first-page":"176","DOI":"10.5301\/hip.2011.6527","article-title":"A prospective randomised study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty.","volume":"21","author":"Zerahn","year":"2011","journal-title":"Hip Int"},{"key":"R39-20260711","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1080\/17453674.2017.1405669","article-title":"The effect of bearing type on the outcome of total hip arthroplasty.","volume":"89","author":"Peters","year":"2018","journal-title":"Acta Orthop"},{"key":"R40-20260711","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1503\/cjs.010715","article-title":"Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene.","volume":"59","author":"Petis","year":"2016","journal-title":"Can J Surg"},{"key":"R41-20260711","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1007\/s00264-013-2036-9","article-title":"A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty.","volume":"37","author":"Kim","year":"2013","journal-title":"Int Orthop"},{"key":"R42-20260711","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1007\/s11999-009-1143-9","article-title":"Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis.","volume":"468","author":"Lombardi","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"R43-20260711","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1302\/0301-620X.104B7.BJJ-2021-1673.R1","article-title":"Oxidized zirconium versus cobalt-chrome femoral heads in total hip arthroplasty: a multicentre prospective randomized controlled trial with ten years\u2019 follow-up.","volume":"104-b","author":"Kayani","year":"2022","journal-title":"Bone Joint J"},{"key":"R44-20260711","doi-asserted-by":"crossref","first-page":"1781","DOI":"10.1016\/j.arth.2015.04.040","article-title":"Serum metal ions with a titanium modular neck total hip replacement system.","volume":"30","author":"Gofton","year":"2015","journal-title":"J Arthroplasty"},{"key":"R45-20260711","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1016\/j.arth.2019.09.051","article-title":"Eighteen-year follow-up study of 2 alternative bearing surfaces used in total hip arthroplasty in the same young patients.","volume":"35","author":"Kim","year":"2020","journal-title":"J Arthroplasty"},{"key":"R46-20260711","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1097\/CORR.0000000000002924","article-title":"No difference in revision rates and high survival rates in large-head metal-on-metal THA versus metal-on-polyethylene THA: long-term results of a randomized controlled trial.","volume":"482","author":"Spierenburg","year":"2024","journal-title":"Clin Orthop Relat Res"},{"key":"R47-20260711","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1080\/17453674.2017.1350370","article-title":"Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations.","volume":"88","author":"Dahlstrand","year":"2017","journal-title":"Acta Orthop"},{"key":"R48-20260711","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s11999-011-2076-7","article-title":"Ceramic bearings for total hip arthroplasty have high survivorship at 10 years.","volume":"470","author":"D\u2019Antonio","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"R49-20260711","doi-asserted-by":"crossref","first-page":"367","DOI":"10.2106\/00004623-200702000-00019","article-title":"Failure analysis of a ceramic bearing acetabular component.","volume":"89","author":"Poggie","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"R50-20260711","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1302\/0301-620X.94B4.27735","article-title":"A prospective randomised controlled trial comparing three alternative bearing surfaces in primary total hip replacement.","volume":"94","author":"Nikolaou","year":"2012","journal-title":"J Bone Joint Surg Br"},{"key":"R51-20260711","doi-asserted-by":"crossref","first-page":"592","DOI":"10.5301\/HIP.2012.10360","article-title":"The effect of femoral head size on functional outcome in primary total hip arthroplasty: a single-blinded randomised controlled trial.","volume":"22","author":"Hanna","year":"2012","journal-title":"Hip Int"},{"key":"R52-20260711","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1002\/jor.21389","article-title":"Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients.","volume":"29","author":"Kadar","year":"2011","journal-title":"J Orthop Res"},{"key":"R53-20260711","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.arth.2009.05.023","article-title":"Differences in highly cross-linked polyethylene wear between zirconia and cobalt-chromium femoral heads in Japanese patients: a prospective, randomized study.","volume":"24","author":"Kawate","year":"2009","journal-title":"J Arthroplasty"},{"key":"R54-20260711","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s11999-008-0540-9","article-title":"2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.","volume":"467","author":"Engh","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"R55-20260711","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/j.arth.2008.07.019","article-title":"Elevated serum concentrations of cobalt, chromium, nickel, and manganese after metal-on-metal alloarthroplasty of the hip: a prospective randomized study.","volume":"24","author":"Dahlstrand","year":"2009","journal-title":"J Arthroplasty"},{"key":"R56-20260711","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/01.blo.0000223999.10389.c9","article-title":"No increased migration in cups with ceramic-on-ceramic bearing: an RSA study.","volume":"448","author":"Zhou","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R57-20260711","doi-asserted-by":"crossref","first-page":"168","DOI":"10.5301\/hip.2011.7418","article-title":"Crowe Type I and II DDH managed by large diameter metal-on-metal total hip arthroplasty.","volume":"21","author":"Yalcin","year":"2011","journal-title":"Hip Int"},{"issue":"Suppl 1","key":"R58-20260711","doi-asserted-by":"crossref","first-page":"S20","DOI":"10.1055\/s-2007-965655","article-title":"EBRA migration patterns of the Plasmacup with ceramic or polyethylene inserts: a randomised study.","volume":"145","author":"Ochs","year":"2007","journal-title":"Z Orthop Unfall"},{"key":"R59-20260711","first-page":"1769","article-title":"Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.","volume":"87","author":"Kim","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"R60-20260711","doi-asserted-by":"crossref","first-page":"360","DOI":"10.3109\/17453674.2013.810516","article-title":"More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: a 10-year follow-up with radiostereometry in 43 hips.","volume":"84","author":"Dahl","year":"2013","journal-title":"Acta Orthop"},{"key":"R61-20260711","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/01.blo.0000068766.86536.d3","article-title":"Migration of metal-on-metal versus ceramic-on-polyethylene hip prostheses.","volume":"412","author":"Pabinger","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"R62-20260711","doi-asserted-by":"crossref","first-page":"2168","DOI":"10.2106\/00004623-200311000-00017","article-title":"Serum cobalt levels after metal-on-metal total hip arthroplasty.","volume":"85","author":"Brodner","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R63-20260711","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1016\/j.arth.2009.05.020","article-title":"Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial.","volume":"24","author":"Ise","year":"2009","journal-title":"J Arthroplasty"},{"key":"R64-20260711","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1177\/1457496913491874","article-title":"The effect of different bearing surfaces on metal ion levels in urine following 28\u2009mm metal-on-metal and 28\u2009mm metal-on-polyethylene total hip arthroplasty.","volume":"102","author":"Tiusanen","year":"2013","journal-title":"Scand J Surg"},{"key":"R65-20260711","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1016\/j.arth.2009.09.006","article-title":"Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads.","volume":"25","author":"Nakahara","year":"2010","journal-title":"J Arthroplasty"},{"key":"R66-20260711","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1302\/2058-5241.3.180300","article-title":"Bearing surfaces in primary total hip arthroplasty.","volume":"3","author":"Zagra","year":"2018","journal-title":"EFORT Open Rev"},{"key":"R67-20260711","doi-asserted-by":"crossref","first-page":"266","DOI":"10.2340\/17453674.2023.13384","article-title":"Does choice of bearings influence the survival of cementless total hip arthroplasty in patients aged 20\u201355 years? Comparison of 21,594 patients reported to the Nordic Arthroplasty Register Association dataset 2005\u20132017.","volume":"94","author":"Mikkelsen","year":"2023","journal-title":"Acta Orthop"},{"key":"R68-20260711","doi-asserted-by":"crossref","first-page":"330","DOI":"10.5301\/hipint.5000574","article-title":"Long-term clinical results of the Metasul metal-on-metal total hip arthroplasty: 12.6 years follow-up of 128 primary total hip replacements. Hip international: the journal of clinical and experimental research on hip pathology and therapy.","volume":"28","author":"Zuiderbaan","year":"2018","journal-title":"Hip Int"},{"key":"R69-20260711","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.jval.2018.08.013","article-title":"Choice of prosthetic implant combinations in total hip replacement: cost-effectiveness analysis using UK and Swedish hip joint registries data.","volume":"22","author":"Fawsitt","year":"2019","journal-title":"Value Health"},{"key":"R70-20260711","doi-asserted-by":"crossref","first-page":"2308","DOI":"10.1016\/j.arth.2022.05.013","article-title":"Long-term wear-related complications of cross-linked versus conventional polyethylene after total hip arthroplasty: a meta-analysis.","volume":"37","author":"Yoon","year":"2022","journal-title":"J Arthroplasty"},{"key":"R71-20260711","doi-asserted-by":"crossref","first-page":"2031","DOI":"10.1007\/s11999-014-4065-0","article-title":"There are no differences in short- to mid-term survivorship among total hip-bearing surface options: a network meta-analysis.","volume":"473","author":"Wyles","year":"2015","journal-title":"Clin Orthop Relat Res"},{"key":"R72-20260711","doi-asserted-by":"crossref","first-page":"e1004478","DOI":"10.1371\/journal.pmed.1004478","article-title":"The association of bearing surface materials with the risk of revision following primary total hip replacement: a cohort analysis of 1,026,481 hip replacements from the National Joint Registry.","volume":"21","author":"Whitehouse","year":"2024","journal-title":"PLoS Med"},{"key":"R73-20260711","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1080\/08941939.2019.1606370","article-title":"Cross-linked versus conventional polyethylene for long-term clinical outcomes after total hip arthroplasty: a systematic review and meta-analysis.","volume":"34","author":"Shi","year":"2021","journal-title":"J Invest Surg"},{"key":"R74-20260711","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1007\/s11999-016-4917-x","article-title":"Do the reasons for ceramic-on-ceramic revisions differ from other bearings in total hip arthroplasty?","volume":"474","author":"Migaud","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"R75-20260711","doi-asserted-by":"crossref","first-page":"1448","DOI":"10.1302\/0301-620X.91B11.22100","article-title":"Ceramic-on-ceramic bearing surface and risk of revision due to dislocation after primary total hip replacement.","volume":"91","author":"Sexton","year":"2009","journal-title":"J Bone Joint Surg Br"},{"key":"R76-20260711","first-page":"153","article-title":"Different types of bearing surfaces in primary total hip arthroplasty: a systematic review.","volume":"10","author":"Almaawi","year":"2021","journal-title":"Int J Med Res Health Sci"},{"key":"R77-20260711","first-page":"21871","article-title":"Is there any difference in survivorship of total hip arthroplasty with different bearing surfaces? A systematic review and network meta-analysis.","volume":"8","author":"Yin","year":"2015","journal-title":"Int J Clin Exp Med"},{"key":"R78-20260711","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1007\/s11999-014-3952-8","article-title":"Are younger patients undergoing THA appropriately characterized as active?","volume":"473","author":"Keeney","year":"2015","journal-title":"Clin Orthop Relat Res"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000049085","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T14:01:34Z","timestamp":1783778494000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000049085"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,5]]},"references-count":78,"journal-issue":{"issue":"23","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000049085","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,5]]},"assertion":[{"value":"2025-08-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}