{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T17:16:02Z","timestamp":1783617362304,"version":"3.55.0"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"27","license":[{"start":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:00:00Z","timestamp":1783036800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Zhenhai Hospital of Traditional Chinese Medicine and Jiamusi Traditional Chinese Medicine Hospital","award":["N\/A"],"award-info":[{"award-number":["N\/A"]}]},{"name":"\u00e2\u20ac\u01532025 Zhejiang Provincial Traditional Chinese Medicine Science and Technology Plan (Traditional Chinese Medicine Clinical Research Program)\u00e2\u20ac\u009d","award":["2025ZX178"],"award-info":[{"award-number":["2025ZX178"]}]},{"name":"2024 Ningbo Municipal Health Science and Technology Program Project","award":["2024Y37"],"award-info":[{"award-number":["2024Y37"]}]},{"name":"Ningbo Municipal Natural Science Foundation Project","award":["2024J272"],"award-info":[{"award-number":["2024J272"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7,3]]},"abstract":"<jats:sec>\n                    <jats:title>Rationale:<\/jats:title>\n                    <jats:p>Gustilo type IIIb fractures are severe open injuries often accompanied by extensive soft-tissue damage, bone defects, and joint destruction, posing significant therapeutic challenges. As an emerging technology, 3D printing offers a novel approach to personalized prosthesis design and bone-joint reconstruction. This case report aims to demonstrate the feasibility and clinical outcomes of applying a staged strategy combined with 3D-printed custom implants to such a complex injury.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient concerns:<\/jats:title>\n                    <jats:p>A 31-year-old Asian male sustained a severe open injury to his right lower limb following a traffic accident, presenting with extensive soft-tissue loss, exposed bone, and obvious deformity of the right knee and ankle, accompanied by active bleeding and severe pain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Diagnoses:<\/jats:title>\n                    <jats:p>Gustilo type IIIb open injury of the right lower limb; destructive injury of the medial knee joint complex; and open fracture of the right medial malleolus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions:<\/jats:title>\n                    <jats:p>A multistage treatment strategy was employed: multiple planned debridements combined with vacuum sealing drainage and targeted antimicrobial therapy (e.g., linezolid and amikacin); after infection control, fracture treatment with open reduction, internal fixation, and free skin grafting was performed for the ankle. The exposed bone defect on the medial knee was filled with vancomycin-loaded bone paste and covered with a rectus femoris muscle flap transfer. Definitive joint reconstruction surgery was performed 6 months post-injury. Based on mirrored data from the contralateral healthy limb, joint reconstruction was achieved using a rotating-hinge knee prosthesis, restoring the anatomical structure of the segmental femoral and tibial bone defects and the mechanical stability of the knee joint.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcomes:<\/jats:title>\n                    <jats:p>The patient recovered well postoperatively, with significant improvement in knee function. The custom augmentation demonstrated close apposition to the host bone with ideal bone healing. Imaging assessment showed satisfactory prosthesis positioning, restored lower-limb alignment and joint-line height, and joint stability, without early prosthesis loosening or other complications. The Hospital for Special Surgery knee score improved from 27 to 83 points, indicating rapid functional rehabilitation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Lessons:<\/jats:title>\n                    <jats:p>For complex lower-limb trauma with severe bone defects, adhering to the multistage treatment principle combining \u201cdamage control\u201d and \u201cfunctional reconstruction\u201d is crucial. Three-dimensional printing technology enables the customization of prostheses that precisely match individual bone defect morphologies, providing a stable and efficient solution for reconstructing complex bone defects.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000049595","type":"journal-article","created":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T17:00:30Z","timestamp":1783098030000},"page":"e49595","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["The application of 3D printing technology in multistage functional reconstruction of severe Gustilo IIIb right lower limb injury: artificial hinged knee prosthesis replacement: A case report"],"prefix":"10.1097","volume":"105","author":[{"given":"Wei","family":"Zhao","sequence":"first","affiliation":[{"name":"Department of Orthopedics, Zhenhai District Traditional Chinese Medicine Hospital, Zhenhai District Longsai Medical Group, Ningbo, Zhejiang Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wujun","family":"Xing","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Jiamusi Hospital of Traditional Chinese Medicine, Affiliated to Heilongjiang University of Chinese Medicine, Jiamusi, Heilongjiang Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1934-5400","authenticated-orcid":false,"given":"Jianruo","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Zhenhai District Traditional Chinese Medicine Hospital, Zhenhai District Longsai Medical Group, Ningbo, Zhejiang Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaojun","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Zhenhai District Traditional Chinese Medicine Hospital, Zhenhai District Longsai Medical Group, Ningbo, Zhejiang Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260709","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.ijsu.2020.07.013","article-title":"The Masquelet technique combined with the muscle flap for use in emergency management of acute Gustilo type III trauma of the lower limb with segmental bone loss: case series.","volume":"81","author":"Deng","year":"2020","journal-title":"Int J Surg"},{"key":"R2-20260709","doi-asserted-by":"crossref","first-page":"1522","DOI":"10.1097\/PRS.0000000000005552","article-title":"Comparing reconstructive outcomes in patients with Gustilo type IIIB fractures and concomitant arterial injuries.","volume":"143","author":"Ricci","year":"2019","journal-title":"Plast Reconstr Surg"},{"key":"R3-20260709","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.3390\/cancers16091672","article-title":"Joint-sparing resection around the knee for osteosarcoma: long-term outcomes of biologic reconstruction with vascularized fibula graft combined with massive allograft.","volume":"16","author":"Scanferla","year":"2024","journal-title":"Cancers (Basel)"},{"key":"R4-20260709","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1055\/a-1161-9566","article-title":"Reconstruction of large bone defects and complex non-unions using a free fibular bone graft and a supplementary allograft.","volume":"159","author":"Gaida","year":"2021","journal-title":"Z Orthop Unfall"},{"key":"R5-20260709","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.actbio.2020.08.018","article-title":"Additively manufactured biodegradable porous metals.","volume":"115","author":"Li","year":"2020","journal-title":"Acta Biomater"},{"key":"R6-20260709","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1111\/os.14099","article-title":"Comparison of novel 3D-printed stepped porous metal cones and metaphyseal sleeves for reconstruction of severe knee bone defects: short-term clinical outcomes.","volume":"16","author":"Liu","year":"2024","journal-title":"Orthop Surg"},{"key":"R7-20260709","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1089\/wound.2014.0531","article-title":"Current concepts and ongoing research in the prevention and treatment of open fracture infections.","volume":"4","author":"Hannigan","year":"2015","journal-title":"Adv Wound Care (New Rochelle)"},{"key":"R8-20260709","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1177\/1071100720929007","article-title":"Biomechanical effect on joint stability of including deltoid ligament repair in an ankle fracture soft tissue injury model with deltoid and syndesmotic disruption.","volume":"41","author":"Mococain","year":"2020","journal-title":"Foot Ankle Int"},{"key":"R9-20260709","doi-asserted-by":"crossref","first-page":"369","DOI":"10.5435\/00124635-200807000-00002","article-title":"The urgency of surgical d\u00e9bridement in the management of open fractures.","volume":"16","author":"Werner","year":"2008","journal-title":"J Am Acad Orthop Surg"},{"key":"R10-20260709","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1111\/j.1749-6632.2011.05962.x","article-title":"Linezolid, the first oxazolidinone antibacterial agent.","volume":"1222","author":"Leach","year":"2011","journal-title":"Ann N Y Acad Sci"},{"key":"R11-20260709","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1007\/s00068-011-0161-y","article-title":"Physiological assessment of the polytrauma patient: initial and secondary surgeries.","volume":"37","author":"Enninghorst","year":"2011","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R12-20260709","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.cps.2021.01.006","article-title":"The optimal timing of traumatic lower extremity reconstruction: current consensus.","volume":"48","author":"Lee","year":"2021","journal-title":"Clin Plast Surg"},{"key":"R13-20260709","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.ijantimicag.2012.12.012","article-title":"Linezolid versus vancomycin for meticillin-resistant Staphylococcus aureus infection: a meta-analysis of randomised controlled trials.","volume":"41","author":"An","year":"2013","journal-title":"Int J Antimicrob Agents"},{"key":"R14-20260709","doi-asserted-by":"crossref","first-page":"18387","DOI":"10.1038\/s41598-022-23322-6","article-title":"An ionic silver coating prevents implant-associated infection by anaerobic bacteria in vitro and in vivo in mice.","volume":"12","author":"Soma","year":"2022","journal-title":"Sci Rep"},{"key":"R15-20260709","doi-asserted-by":"crossref","first-page":"3249","DOI":"10.1128\/JCM.00885-12","article-title":"Subtractive hybridization yields a silver resistance determinant unique to nosocomial pathogens in the Enterobacter cloacae complex.","volume":"50","author":"Kremer","year":"2012","journal-title":"J Clin Microbiol"},{"key":"R16-20260709","doi-asserted-by":"crossref","first-page":"2896","DOI":"10.1016\/j.arth.2021.03.009","article-title":"Knee joint bone defects: reconstruction with bone transport and arthrodesis.","volume":"36","author":"Solomin","year":"2021","journal-title":"J Arthroplasty"},{"key":"R17-20260709","doi-asserted-by":"crossref","first-page":"2111","DOI":"10.1111\/os.14193","article-title":"The Ilizarov technique: a dynamic solution for orthopaedic challenges.","volume":"16","author":"Guan","year":"2024","journal-title":"Orthop Surg"},{"key":"R18-20260709","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1186\/s13018-019-1403-7","article-title":"Efficacy evaluation of three-dimensional printing assisted osteotomy guide plate in accurate osteotomy of adolescent cubitus varus deformity.","volume":"14","author":"Zhang","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R19-20260709","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.arth.2014.09.016","article-title":"Treatment of severe bone defects during revision total knee arthroplasty with structural allografts and porous metal cones \u2013 a systematic review.","volume":"30","author":"Beckmann","year":"2015","journal-title":"J Arthroplasty"},{"key":"R20-20260709","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1302\/0301-620X.98B1.36345","article-title":"The management of bone loss in revision total knee arthroplasty: rebuild, reinforce, and augment.","volume":"98-B","author":"Sculco","year":"2016","journal-title":"Bone Joint J"},{"key":"R21-20260709","doi-asserted-by":"crossref","first-page":"3004","DOI":"10.1177\/03635465241280231","article-title":"Clinical outcomes and long-term survivorship after osteochondral autologous transfer combined with valgus high tibial osteotomy: an analysis after 19 years with 56 patients.","volume":"52","author":"Ehmann","year":"2024","journal-title":"Am J Sports Med"},{"key":"R22-20260709","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1080\/17453674.2016.1265877","article-title":"Cartilage repair in the degenerative ageing knee.","volume":"87","author":"Brittberg","year":"2016","journal-title":"Acta Orthop"},{"key":"R23-20260709","doi-asserted-by":"crossref","first-page":"993136","DOI":"10.3389\/fpsyg.2022.993136","article-title":"Risk factors for postoperative delirium following total hip or knee arthroplasty: a meta-analysis.","volume":"13","author":"Zhao","year":"2022","journal-title":"Front Psychol"},{"key":"R24-20260709","doi-asserted-by":"crossref","first-page":"10678","DOI":"10.4081\/ejtm.2022.10678","article-title":"The role of bone mineral density and cartilage volume to predict knee cartilage degeneration.","volume":"32","author":"Ciliberti","year":"2022","journal-title":"Eur J Transl Myol"},{"key":"R25-20260709","doi-asserted-by":"crossref","first-page":"4233","DOI":"10.12659\/MSM.916884","article-title":"Efficacy and prognosis of 3D printing technology in treatment of high-energy trans-syndesmotic ankle fracture dislocation \u2013 \u201clog-splitter\u201d injury.","volume":"25","author":"Zhang","year":"2019","journal-title":"Med Sci Monit"},{"key":"R26-20260709","doi-asserted-by":"crossref","first-page":"1127289","DOI":"10.3389\/fbioe.2023.1127289","article-title":"Application strategy of finite element analysis in artificial knee arthroplasty.","volume":"11","author":"Zhang","year":"2023","journal-title":"Front Bioeng Biotechnol"},{"key":"R27-20260709","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.5114\/aoms.2018.79007","article-title":"Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants.","volume":"14","author":"Arnholdt","year":"2018","journal-title":"Arch Med Sci"},{"key":"R28-20260709","doi-asserted-by":"crossref","first-page":"765","DOI":"10.2106\/JBJS.G.00293","article-title":"Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty.","volume":"90","author":"Catani","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R29-20260709","doi-asserted-by":"crossref","first-page":"3176","DOI":"10.1016\/j.arth.2017.04.060","article-title":"Three-dimensional computed tomography analysis of the posterior tibial slope in 100 knees.","volume":"32","author":"Ho","year":"2017","journal-title":"J Arthroplasty"},{"key":"R30-20260709","doi-asserted-by":"crossref","first-page":"14504","DOI":"10.1038\/s41598-019-50399-3","article-title":"Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses - a robot-assisted test method based on a musculoskeletal model.","volume":"9","author":"Kebbach","year":"2019","journal-title":"Sci Rep"},{"key":"R31-20260709","doi-asserted-by":"crossref","first-page":"2477","DOI":"10.1007\/s11999-014-3621-y","article-title":"Polished trays reduce backside wear independent of post location in posterior-stabilized TKAs.","volume":"472","author":"Abdel","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"R32-20260709","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/CORR.0000000000000991","article-title":"Are TKA kinematics during closed kinetic chain exercises associated with patient-reported outcomes? A preliminary analysis.","volume":"478","author":"Van Onsem","year":"2020","journal-title":"Clin Orthop Relat Res"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000049595","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T17:01:12Z","timestamp":1783616472000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000049595"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,3]]},"references-count":32,"journal-issue":{"issue":"27","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000049595","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,3]]},"assertion":[{"value":"2025-09-12","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-18","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}