{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T19:54:35Z","timestamp":1790884475767,"version":"4.1.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"28","license":[{"start":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T00:00:00Z","timestamp":1783641600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7,10]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>This study aimed to characterize intra-device repeatability and sector-dependent inter-device variability of peripapillary retinal nerve fiber layer (RNFL) measurements across 5 optical coherence tomography (OCT) platforms and define the concept of sector-dependent device discordance, the non-uniform distribution of inter-device measurement bias across anatomical RNFL sectors. This prospective cross-sectional study included 38 healthy participants who underwent peripapillary RNFL imaging using 5 OCT devices: Heidelberg Spectralis, TowardPi BMIZAR 400\u2009kHz swept-source OCT, Huvitz HOCT-1\/1F, NIDEK RS-1 Glauvas, and Topcon Maestro 2. RNFL thickness was analyzed in the superior, nasal, inferior, and temporal sectors, as well as global mean thickness. Three consecutive measurements were obtained for each eye with each device to assess intra-device repeatability. Repeatability was evaluated using repeated-measures analysis of variance. Inter-device reliability was assessed using intraclass correlation coefficients, with Heidelberg Spectralis as the reference. Agreement between devices was further evaluated using Bland\u2013Altman analysis. Excellent intra-device repeatability was documented across all platforms. However, marked inter-device variability demonstrated sector-dependent patterns: global RNFL measurements showed moderate agreement (intraclass correlation coefficient: 0.346\u20130.805), while nasal and temporal sectors exhibited disproportionately higher variability (absolute percentage error up to 20.76% in the nasal sector; limits of agreement width ranging from 20.23% to 35.52% in temporal). Bland\u2013Altman analyses revealed device-specific bias signatures (Huvitz HOCT-1\/1F: \u22128.17% global bias; NIDEK RS-1 Glauvas: +10.59%; Topcon Maestro 2: \u22124.47%), indicating systematic, reproducible platform-inherent differences rather than random measurement noise. While intra-device repeatability is excellent, inter-device RNFL measurements remain substantially discordant, particularly in nasal and temporal sectors, where absolute percentage error reaches up to 20.76% and limits of agreement exceed 35%, a phenomenon termed sector-dependent device discordance. Global RNFL measurements may appear concordant while sectoral measurements diverge, creating a theoretically plausible risk for false progression detection, pending validation in glaucomatous eyes. RNFL measurements are not interchangeable across platforms and are particularly unreliable for sector-specific assessment. Device-consistent monitoring is essential for glaucoma follow-up; multicenter studies and device switching scenarios warrant platform-specific normalization strategies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000049704","type":"journal-article","created":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T22:01:49Z","timestamp":1783720909000},"page":"e49704","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Sector-dependent device discordance of RNFL measurements: A prospective cross-sectional study of cross-platform variability and interchangeability in glaucoma monitoring"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9066-6225","authenticated-orcid":false,"given":"Fevzi","family":"Akkan","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Dunyagoz Eye Hospital, Istanbul, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-0797-8585","authenticated-orcid":false,"given":"Ebru","family":"G\u00f6rg\u00fcn","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Dunyagoz Eye Hospital, Istanbul, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261001","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1016\/j.preteyeres.2007.08.001","article-title":"A framework for comparing structural and functional measures of glaucomatous damage.","volume":"26","author":"Hood","year":"2007","journal-title":"Prog Retin Eye Res"},{"key":"R2-20261001","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/j.ophtha.2009.04.013","article-title":"Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study.","volume":"116","author":"Leung","year":"2009","journal-title":"Ophthalmology"},{"key":"R3-20261001","doi-asserted-by":"crossref","first-page":"3560","DOI":"10.1038\/s41598-024-54109-6","article-title":"Comparison of retinal thickness measurements among four different optical coherence tomography devices.","volume":"14","author":"Nam","year":"2024","journal-title":"Sci Rep"},{"key":"R4-20261001","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1016\/j.ajo.2010.06.024","article-title":"Comparison of retinal nerve fiber layer thickness in normal eyes using time-domain and spectral-domain optical coherence tomography.","volume":"150","author":"Seibold","year":"2010","journal-title":"Am J Ophthalmol"},{"key":"R5-20261001","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1097\/IJG.0b013e318193c29f","article-title":"Comparison of retinal nerve fiber layer thickness values using Stratus Optical Coherence Tomography and Heidelberg Retina Tomograph-III.","volume":"18","author":"Moreno-Monta\u00f1\u00e9s","year":"2009","journal-title":"J Glaucoma"},{"key":"R6-20261001","doi-asserted-by":"crossref","first-page":"5724","DOI":"10.1167\/iovs.10-5222","article-title":"Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes.","volume":"51","author":"Mwanza","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R7-20261001","doi-asserted-by":"crossref","first-page":"1529719","DOI":"10.3389\/fmed.2025.1529719","article-title":"Comparison of macular retinal thickness measurements using spectral-domain and swept-source optical coherence tomography in healthy eyes.","volume":"12","author":"Wan","year":"2025","journal-title":"Front Med (Lausanne)"},{"key":"R8-20261001","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1016\/j.ophtha.2006.08.046","article-title":"Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT.","volume":"114","author":"Budenz","year":"2007","journal-title":"Ophthalmology"},{"key":"R9-20261001","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1097\/IJG.0b013e31829521db","article-title":"Reproducibility of spectral-domain optical coherence tomography measurements in adult and pediatric glaucoma.","volume":"24","author":"Ghasia","year":"2015","journal-title":"J Glaucoma"},{"key":"R10-20261001","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1097\/ICU.0b013e32835d9e27","article-title":"Diagnosis of glaucoma and detection of glaucoma progression using spectral domain optical coherence tomography.","volume":"24","author":"Grewal","year":"2013","journal-title":"Curr Opin Ophthalmol"},{"key":"R11-20261001","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1016\/j.ajo.2014.01.014","article-title":"Correlation of retinal nerve fiber layer thickness and visual fields in glaucoma: a broken stick model.","volume":"157","author":"Alasil","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R12-20261001","first-page":"482","article-title":"Correlation between visual field sensitivity and retinal nerve fiber layer thickness in unilateral exfoliation syndrome.","volume":"63","author":"\u0160imi\u0107 Prskalo","year":"2024","journal-title":"Acta Clin Croat"},{"key":"R13-20261001","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1159\/000485957","article-title":"Reliability of vessel density measurements in the peripapillary retina and correlation with retinal nerve fiber layer thickness in healthy subjects using optical coherence tomography angiography.","volume":"240","author":"She","year":"2018","journal-title":"Ophthalmologica"},{"key":"R14-20261001","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1007\/s40123-021-00377-8","article-title":"Agreement between spectral-domain and swept-source optical coherence tomography retinal thickness measurements in macular and retinal disease.","volume":"10","author":"Hanumunthadu","year":"2021","journal-title":"Ophthalmol Ther"},{"key":"R15-20261001","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","article-title":"Optical coherence tomography angiography.","volume":"64","author":"Spaide","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"R16-20261001","doi-asserted-by":"crossref","first-page":"2990","DOI":"10.4103\/ijo.IJO_81_22","article-title":"Mapping the thickness of retinal layers using Spectralis spectral domain optical coherence tomography in Indian eyes.","volume":"70","author":"Najeeb","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"R17-20261001","doi-asserted-by":"crossref","first-page":"15876","DOI":"10.1038\/s41598-023-43230-7","article-title":"Agreement and precision of wide and cube scan measurements between swept-source and spectral-domain OCT in normal and glaucoma eyes.","volume":"13","author":"Hou","year":"2023","journal-title":"Sci Rep"},{"key":"R18-20261001","doi-asserted-by":"crossref","first-page":"12","DOI":"10.4103\/jmss.JMSS_67_19","article-title":"Evaluation of asymmetry in right and left eyes of normal individuals using extracted features from optical coherence tomography and fundus images.","volume":"11","author":"Mahmudi","year":"2021","journal-title":"J Med Signals Sens"},{"key":"R19-20261001","doi-asserted-by":"crossref","first-page":"334","DOI":"10.3390\/diagnostics10050334","article-title":"Reporting standards for a Bland-Altman agreement analysis: a review of methodological reviews.","volume":"10","author":"Gerke","year":"2020","journal-title":"Diagnostics (Basel)"},{"key":"R20-20261001","doi-asserted-by":"crossref","first-page":"1612455","DOI":"10.3389\/fcell.2025.1612455","article-title":"Standardized conversion model for retinal thickness measurements between spectral-domain and swept-source optical coherence tomography based on machine learning.","volume":"13","author":"Tian","year":"2025","journal-title":"Front Cell Dev Biol"},{"key":"R21-20261001","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.ogla.2025.02.005","article-title":"Retinal nerve fiber layer rates of change: comparison of 2 OCT devices.","volume":"8","author":"Mohammadzadeh","year":"2025","journal-title":"Ophthalmol Glaucoma"},{"key":"R22-20261001","doi-asserted-by":"crossref","first-page":"e001531","DOI":"10.1136\/bmjophth-2023-001531","article-title":"Factors influencing the reliability of measurements in eyes with full-thickness macular holes: are we measuring incorrectly?","volume":"9","author":"Moussa","year":"2024","journal-title":"BMJ Open Ophthalmol"},{"key":"R23-20261001","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1186\/s12886-025-04257-8","article-title":"Repeatability, reproducibility, and agreement for three optical coherence tomography instruments.","volume":"25","author":"Zhang","year":"2025","journal-title":"BMC Ophthalmol"},{"key":"R24-20261001","doi-asserted-by":"crossref","first-page":"78","DOI":"10.4274\/tjo.galenos.2018.88972","article-title":"Repeatability and agreement of macular thickness measurements obtained with two different scan modes of the optovue RTVue optical coherence tomography device.","volume":"49","author":"Kola","year":"2019","journal-title":"Turk J Ophthalmol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000049704","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T19:01:06Z","timestamp":1790881266000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000049704"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,10]]},"references-count":24,"journal-issue":{"issue":"28","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000049704","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,10]]},"assertion":[{"value":"2026-03-12","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}