{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T01:06:50Z","timestamp":1794618410815,"version":"4.9.1"},"reference-count":62,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"30","license":[{"start":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T00:00:00Z","timestamp":1784851200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7,24]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Endoscopic ultrasonography-guided drainage is an effective treatment for pancreatic fluid collections (PFCs). However, the optimal stent strategy for endoscopic ultrasonography-guided drainage of PFCs is still unclear. This study aims to compare the clinical outcomes of different stent types to identify the best option.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Databases including PubMed, EMBASE, and Cochrane were searched up to August 2024. The analysis focused on comparisons between bi-flanged metal stents (BFMS), double-pigtail plastic stents (DPPS), fully covered self-expanding metal stents (FCSEMS), lumen-apposing metal stents (LAMS), and the combination of LAMS and DPPS (LAMS\u2005+\u2005DPPS).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 38 studies, involving 4265 patients with PFCs, were analyzed. In all of these patients, LAMS (risk ratio [RR]: 1.07, 95% confidence interval [CI]: 1.02\u20131.13) and BFMS (RR: 1.08, 95% CI: 1.01\u20131.15) showed higher clinical success rates compared with DPPS. LAMS\u2005+\u2005DPPS reduced infection rates compared with BFMS (RR: 0.32, 95% CI: 0.10\u20130.99), DPPS (RR: 0.19, 95% CI: 0.06\u20130.62), and FCSEMS (RR: 0.23, 95% CI: 0.07\u20130.76). Within the pancreatic pseudocysts subgroup, LAMS (RR: 1.08, 95% CI: 1.01\u20131.16) and LAMS\u2005+\u2005DPPS (RR: 1.24, 95% CI: 1.03\u20131.48) demonstrated higher clinical success rates compared with DPPS. Similarly, in the walled-off necrosis subgroup, LAMS (RR: 1.10, 95% CI: 1.02\u20131.17), LAMS\u2005+\u2005DPPS (RR: 1.19, 95% CI: 1.01\u20131.41), FCSEMS (RR: 1.14, 95% CI: 1.03\u20131.26), and BFMS (RR: 1.11, 95% CI: 1.03\u20131.20) all showed higher success rates compared with DPPS, with BFMS exhibiting a lower bleeding rate than DPPS (RR: 0.32, 95% CI: 0.18\u20130.99).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Newer metal stents, including BFMS, LAMS, and LAMS\u2005+\u2005DPPS, offer advantages over plastic stents like DPPS alone. BFMS is preferable when bleeding risk is a concern, while LAMS\u2005+\u2005DPPS is more effective in reducing infection rates in PFCs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000049877","type":"journal-article","created":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T19:00:59Z","timestamp":1784919659000},"page":"e49877","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Comparative safety and effectiveness of stents in drainage of pancreatic fluid collections guided by endoscopic ultrasonography: A systematic review and network meta-analysis"],"prefix":"10.1097","volume":"105","author":[{"given":"Shengbiao","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Emergency Medicine, Fujian Medical University, Fuzhou, China"},{"name":"Department of Emergency Intensive Care Unit, The Affiliated Hospital of Putian University, Putian, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaxin","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Fujian Medical University, Fuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuwei","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Fujian Medical University, Fuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bibi","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Emergency Intensive Care Unit, The Affiliated Hospital of Putian University, Putian, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-3701-1093","authenticated-orcid":false,"given":"Handong","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Fujian Medical University, Fuzhou, China"},{"name":"Department of Emergency Intensive Care Unit, The Affiliated Hospital of Putian University, Putian, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261001","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.gie.2015.11.027","article-title":"The role of endoscopy in the diagnosis and treatment of inflammatory pancreatic fluid collections.","volume":"83","author":"Muthusamy","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"R2-20261001","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1001\/jama.2020.20317","article-title":"Acute pancreatitis: a review.","volume":"325","author":"Mederos","year":"2021","journal-title":"JAMA"},{"key":"R3-20261001","doi-asserted-by":"crossref","first-page":"341","DOI":"10.5009\/gnl.2014.8.4.341","article-title":"Endoscopic ultrasound-guided transluminal drainage for peripancreatic fluid collections: where are we now?","volume":"8","author":"Kawakami","year":"2014","journal-title":"Gut Liver"},{"key":"R4-20261001","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1055\/a-0588-5365","article-title":"Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelines.","volume":"50","author":"Arvanitakis","year":"2018","journal-title":"Endoscopy"},{"key":"R5-20261001","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.gie.2017.06.029","article-title":"EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: comparison of efficacy and adverse event rates.","volume":"87","author":"Lang","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"R6-20261001","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1055\/s-0031-1291624","article-title":"Endoscopic ultrasound-guided transmural drainage of infected pancreatic fluid collections with placement of covered self-expanding metal stents: a case series.","volume":"44","author":"Fabbri","year":"2012","journal-title":"Endoscopy"},{"key":"R7-20261001","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.gie.2014.06.025","article-title":"Management of pancreatic collections with a novel endoscopically placed fully covered self-expandable metal stent: a national experience (with videos).","volume":"81","author":"Chandran","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"R8-20261001","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1111\/den.12704","article-title":"Endoscopic ultrasonography-guided transmural drainage of walled-off pancreatic necrosis: comparison between a specially designed fully covered bi-flanged metal stent and multiple plastic stents.","volume":"29","author":"Bapaye","year":"2017","journal-title":"Dig Endosc"},{"key":"R9-20261001","first-page":"335","article-title":"Lumen-apposing metal stents in management of pancreatic fluid collections: the nobody\u2019s land of removal timing.","volume":"25","author":"De Angelis","year":"2019","journal-title":"Saudi J Gastroenterol"},{"key":"R10-20261001","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1016\/j.cgh.2018.02.021","article-title":"Increased incidence of pseudoaneurysm bleeding with lumen-apposing metal stents compared to double-pigtail plastic stents in patients with peripancreatic fluid collections.","volume":"16","author":"Brimhall","year":"2018","journal-title":"Clin Gastroenterol Hepatol"},{"key":"R11-20261001","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1053\/j.gastro.2019.07.064","article-title":"American Gastroenterological Association clinical practice update: management of pancreatic necrosis.","volume":"158","author":"Baron","year":"2020","journal-title":"Gastroenterology"},{"key":"R12-20261001","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s10620-017-4851-0","article-title":"Efficacy and safety of lumen-apposing metal stents in management of pancreatic fluid collections: are they better than plastic stents? A systematic review and meta-analysis.","volume":"63","author":"Hammad","year":"2018","journal-title":"Dig Dis Sci"},{"key":"R13-20261001","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1002\/jhbp.1008","article-title":"Head-to-head comparison between endoscopic ultrasound guided lumen apposing metal stent and plastic stents for the treatment of pancreatic fluid collections: a systematic review and meta-analysis.","volume":"29","author":"Guzm\u00e1n-Calder\u00f3n","year":"2022","journal-title":"J Hepatobiliary Pancreat Sci"},{"key":"R14-20261001","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1111\/jgh.14960","article-title":"Comparative efficacy of stents in endoscopic ultrasonography-guided peripancreatic fluid collection drainage: a systematic review and network meta-analysis.","volume":"35","author":"Park","year":"2020","journal-title":"J Gastroenterol Hepatol"},{"key":"R15-20261001","doi-asserted-by":"crossref","first-page":"264","DOI":"10.7326\/0003-4819-151-4-200908180-00135","article-title":"Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement.","volume":"151","author":"Moher","year":"2009","journal-title":"Ann Intern Med"},{"key":"R16-20261001","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1001\/jama.2020.18678","article-title":"Pancreatic cysts\u2014an overview and summary of society guidelines, 2021.","volume":"325","author":"Ayoub","year":"2021","journal-title":"JAMA"},{"key":"R17-20261001","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1136\/gutjnl-2012-302779","article-title":"Classification of acute pancreatitis\u20132012: revision of the Atlanta classification and definitions by international consensus.","volume":"62","author":"Banks","year":"2013","journal-title":"Gut"},{"key":"R18-20261001","doi-asserted-by":"crossref","first-page":"I4898","DOI":"10.1136\/bmj.l4898","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials.","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"key":"R19-20261001","doi-asserted-by":"crossref","first-page":"i4919","DOI":"10.1136\/bmj.i4919","article-title":"ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions.","volume":"355","author":"Sterne","year":"2016","journal-title":"BMJ"},{"key":"R20-20261001","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1177\/09622802231172043","article-title":"Detecting the skewness of data from the five-number summary and its application in meta-analysis.","volume":"32","author":"Shi","year":"2023","journal-title":"Stat Methods Med Res"},{"key":"R21-20261001","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1186\/1471-2288-14-135","article-title":"Estimating the sample mean and standard deviation from the sample size, median, range and\/or interquartile range.","volume":"14","author":"Wan","year":"2014","journal-title":"BMC Med Res Methodol"},{"key":"R22-20261001","doi-asserted-by":"crossref","first-page":"1785","DOI":"10.1177\/0962280216669183","article-title":"Optimally estimating the sample mean from the sample size, median, mid-range, and\/or mid-quartile range.","volume":"27","author":"Luo","year":"2018","journal-title":"Stat Methods Med Res"},{"key":"R23-20261001","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test.","volume":"315","author":"Egger","year":"1997","journal-title":"BMJ"},{"key":"R24-20261001","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1055\/s-0034-1390871","article-title":"Newly designed, fully covered metal stents for endoscopic ultrasound (EUS)-guided transmural drainage of peripancreatic fluid collections: a prospective randomized study.","volume":"46","author":"Lee","year":"2014","journal-title":"Endoscopy"},{"key":"R25-20261001","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.gie.2015.02.035","article-title":"Metal versus plastic for pancreatic pseudocyst drainage: clinical outcomes and success.","volume":"82","author":"Sharaiha","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"R26-20261001","doi-asserted-by":"crossref","first-page":"320","DOI":"10.4103\/2303-9027.191659","article-title":"A two-center comparative study of plastic and lumen-apposing large diameter self-expandable metallic stents in endoscopic ultrasound-guided drainage of pancreatic fluid collections.","volume":"5","author":"Ang","year":"2016","journal-title":"Endosc Ultrasound"},{"key":"R27-20261001","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/den.12681","article-title":"Lumen-apposing metal stents for drainage of pancreatic fluid collections: when and for whom?","volume":"29","author":"Bang","year":"2017","journal-title":"Dig Endosc"},{"key":"R28-20261001","doi-asserted-by":"crossref","first-page":"E1189","DOI":"10.1055\/s-0043-120831","article-title":"A comparison of outcomes between a lumen-apposing metal stent with electrocautery-enhanced delivery system and a bi-flanged metal stent for drainage of walled-off pancreatic necrosis.","volume":"5","author":"Bekkali","year":"2017","journal-title":"Endosc Int Open"},{"key":"R29-20261001","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1016\/j.gie.2016.08.014","article-title":"Fully covered self-expandingmetal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success.","volume":"85","author":"Siddiqui","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"R30-20261001","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1016\/j.gie.2017.11.033","article-title":"Safety and efficacy of lumen-apposing metal stents with and without simultaneous double-pigtail plastic stents for draining pancreatic pseudocyst.","volume":"87","author":"Aburajab","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"R31-20261001","doi-asserted-by":"crossref","first-page":"249","DOI":"10.2147\/CEG.S167736","article-title":"Comparing efficacy of lumen-apposing stents to plastic stents in the endoscopic management of mature peripancreatic fluid collections: a single-center experience.","volume":"11","author":"Fasullo","year":"2018","journal-title":"Clin Exp Gastroenterol"},{"key":"R32-20261001","doi-asserted-by":"crossref","first-page":"2448","DOI":"10.1007\/s00464-017-5946-6","article-title":"Comparison of clinical efficacies and safeties of lumen-apposing metal stent and conventional-type metal stent-assisted EUS-guided pancreatic wall-off necrosis drainage: a real-life experience in a tertiary hospital.","volume":"32","author":"Law","year":"2018","journal-title":"Surg Endosc"},{"key":"R33-20261001","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1055\/a-0582-9127","article-title":"Safety of lumen-apposingstent with or without coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a retrospective study.","volume":"50","author":"Puga","year":"2018","journal-title":"Endoscopy"},{"key":"R34-20261001","first-page":"620","article-title":"Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?","volume":"32","author":"Ali","year":"2019","journal-title":"Ann Gastroenterol"},{"key":"R35-20261001","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1136\/gutjnl-2017-315335","article-title":"Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial.","volume":"68","author":"Bang","year":"2019","journal-title":"Gut"},{"key":"R36-20261001","doi-asserted-by":"crossref","first-page":"E347","DOI":"10.1055\/a-0828-7630","article-title":"Lumen apposing metal stents are superior to plastic stents in pancreatic walled-off necrosis: a large international multicenter study.","volume":"7","author":"Chen","year":"2019","journal-title":"Endosc Int Open"},{"key":"R37-20261001","doi-asserted-by":"crossref","first-page":"353","DOI":"10.5946\/ce.2018.154","article-title":"Comparison of clinical outcomes between plastic stent and novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of peripancreatic fluid collections.","volume":"52","author":"Shin","year":"2019","journal-title":"Clin Endosc"},{"key":"R38-20261001","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1111\/jgh.14557","article-title":"Comparison of three different stents for endoscopic ultrasound-guided drainage of pancreatic fluid collection: a large retrospective study.","volume":"34","author":"Wang","year":"2019","journal-title":"J Gastroenterol Hepatol"},{"key":"R39-20261001","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1055\/a-0759-1353","article-title":"Lumen-apposing stents versus plastic stents in the management of pancreatic pseudocysts: a large, comparative, international, multicenter study.","volume":"51","author":"Yang","year":"2019","journal-title":"Endoscopy"},{"key":"R40-20261001","doi-asserted-by":"crossref","first-page":"e14179","DOI":"10.1097\/MD.0000000000014179","article-title":"A novel self-expanding biflanged metal stent vs tubular metal stent for EUS-guided transmural drainage of pancreatic pseudocyst: a retrospective, cohort study.","volume":"98","author":"Yao","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"R41-20261001","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1093\/jcag\/gwy049","article-title":"The evolution of EUS-guided transluminal drainage for the treatment of pancreatic fluid collections: a comparison of clinical and cost outcomes with double-pigtail plastic stents, conventional metal stents and lumen-apposing metal stents.","volume":"3","author":"Falk","year":"2020","journal-title":"J Can Assoc Gastroenterol"},{"key":"R42-20261001","doi-asserted-by":"crossref","first-page":"E6","DOI":"10.1055\/a-1031-9295","article-title":"Lumen-apposing metal stents versus biliary fully-covered metal stents for EUS-guided drainage of pancreatic fluid collections: a case control study.","volume":"08","author":"de Paredes","year":"2020","journal-title":"Endosc Int Open"},{"key":"R43-20261001","doi-asserted-by":"crossref","first-page":"2103","DOI":"10.1111\/jgh.15086","article-title":"The role of solid debris in endoscopic ultrasound-guided drainage of walled-off necrosis: a large cohort study.","volume":"35","author":"Zhu","year":"2020","journal-title":"J Gastroenterol Hepatol"},{"key":"R44-20261001","doi-asserted-by":"crossref","first-page":"2698","DOI":"10.1007\/s00464-020-07699-x","article-title":"Endosonography-guided transmural drainage of pancreatic fluid collections: comparative outcomes by stent type.","volume":"35","author":"Kayal","year":"2021","journal-title":"Surg Endosc"},{"key":"R45-20261001","first-page":"273","article-title":"International, multicenter retrospective trial comparing the efficacy and safety of bi-flanged versus lumen-apposing metal stents for endoscopic drainage of walled-off pancreatic necrosis.","volume":"34","author":"Siddiqui","year":"2021","journal-title":"Ann Gastroenterol"},{"key":"R46-20261001","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/SLE.0000000000001046","article-title":"Endoscopic ultrasound\u2013guided drainage of patients with infected walled-off necrosis: which stent to choose?","volume":"32","author":"Muktesh","year":"2022","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"R47-20261001","doi-asserted-by":"crossref","first-page":"53","DOI":"10.4103\/EUS-D-21-00030","article-title":"Double pigtail stent placement as an adjunct to lumen-apposing metal stents for drainage of pancreatic fluid collections may not affect outcomes: a multicenter experience.","volume":"11","author":"Shamah","year":"2022","journal-title":"Endosc Ultrasound"},{"key":"R48-20261001","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1136\/gutjnl-2021-325632","article-title":"Comparison of lumen-apposing metal stents versus double-pigtail plastic stents for infected necrotising pancreatitis.","volume":"72","author":"Boxhoorn","year":"2023","journal-title":"Gut"},{"key":"R49-20261001","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.tige.2022.12.001","article-title":"Safety and efficacy of lumen-apposing metal stents with and without coaxial plastic stents for pancreatic fluid collections.","volume":"25","author":"Haddad","year":"2023","journal-title":"Tech Innov Gastrointest Endosc"},{"key":"R50-20261001","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1136\/gutjnl-2022-328225","article-title":"EUS-guided drainage of large walled-off pancreatic necroses using plastic versus lumen-apposing metal stents: a single-centre randomised controlled trial.","volume":"72","author":"Karstensen","year":"2023","journal-title":"Gut"},{"key":"R51-20261001","first-page":"e37731","article-title":"Self-expandable metal stent (SEMS) versus lumen-apposing metal stent (LAMS) for drainage of pancreatic fluid collections: a randomized clinical trial.","volume":"15","author":"Lera Dos Santos","year":"2023","journal-title":"Cureus"},{"key":"R52-20261001","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.gie.2022.12.026","article-title":"EUS-guided transluminal drainage using lumen-apposing metal stents with or without coaxial plastic stents for treatment of walled-off necrotizing pancreatitis: a prospective bicentric randomized controlled trial.","volume":"97","author":"Vanek","year":"2023","journal-title":"Gastrointest Endosc"},{"key":"R53-20261001","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.gie.2023.09.005","article-title":"Lumen-apposing metal stents with or without coaxial plastic stent placement for the management of pancreatic fluid collections.","volume":"99","author":"AbiMansour","year":"2024","journal-title":"Gastrointest Endosc"},{"key":"R54-20261001","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.dld.2023.07.012","article-title":"Endoscopic ultrasound-guided drainage of pancreatic collections with dedicated metal stents: a nationwide, multicenter, propensity score-matched comparison.","volume":"56","author":"Coluccio","year":"2024","journal-title":"Dig Liver Dis"},{"key":"R55-20261001","doi-asserted-by":"crossref","first-page":"2148","DOI":"10.1007\/s00464-024-10699-w","article-title":"Plastic pigtail vs lumen-apposing metal stents for drainage of walled-off necrosis (PROMETHEUS study): an open-label, multicenter randomized trial.","volume":"38","author":"Gornals","year":"2024","journal-title":"Surg Endosc"},{"key":"R56-20261001","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1055\/a-2332-3448","article-title":"Biflanged metal stents versus plastic stents for endoscopic ultrasound-guided drainage of walled-off necrosis: a randomized controlled trial.","volume":"56","author":"Koduri","year":"2024","journal-title":"Endoscopy"},{"key":"R57-20261001","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1055\/a-2219-3179","article-title":"Lumen-apposing metal stents for the treatment of pancreatic and peripancreatic fluid collections and bleeding risk: a propensity matched study.","volume":"56","author":"Mangiavillano","year":"2024","journal-title":"Endoscopy"},{"key":"R58-20261001","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1055\/a-2342-1140","article-title":"A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study.","volume":"56","author":"Moon","year":"2024","journal-title":"Endoscopy"},{"key":"R59-20261001","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.gie.2017.04.032","article-title":"Large-caliber metal stents versus plastic stents for the management of pancreatic walled-off necrosis.","volume":"87","author":"Abu Dayyeh","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"R60-20261001","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1080\/07853890.2022.2164048","article-title":"Safety and efficacy of lumen-apposing metal stents and double-pigtail plastic stents for endoscopic ultrasound-guided drainage of walled-off necrosis; a systematic review and meta-analysis.","volume":"55","author":"Khizar","year":"2023","journal-title":"Ann Med"},{"key":"R61-20261001","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1111\/den.14406","article-title":"Measurement of the anchoring force of covered self-expandable and lumen-apposing metal stents for interventional endoscopic ultrasonography.","volume":"35","author":"Takasaki","year":"2023","journal-title":"Dig Endosc"},{"key":"R62-20261001","doi-asserted-by":"crossref","first-page":"442","DOI":"10.4103\/EUS-D-21-00189","article-title":"Controversies in EUS-guided treatment of walled-off necrosis.","volume":"11","author":"Hocke","year":"2022","journal-title":"Endosc Ultrasound"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000049877","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T18:01:28Z","timestamp":1790877688000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000049877"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,24]]},"references-count":62,"journal-issue":{"issue":"30","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000049877","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,24]]},"assertion":[{"value":"2025-08-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}