{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T11:12:47Z","timestamp":1788606767190,"version":"build-2803163510"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"36","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9,4]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      This study compares the clinical and radiological outcomes of volar plating alone and combined volar and radial column plating in the management of Arbeitsgemeinschaft f\u00fcr Osteosynthesefragen (AO) type C2\u2013C3 distal radius fractures. This retrospective cohort study included 80 patients with AO type C2\u2013C3 distal radius fractures who were treated with either single volar plating (n\u2005=\u200550) or combined volar and radial column plating (n\u2005=\u200530). The patients were followed up for a minimum of 2 years. Outcome measures included the Patient-Rated Wrist Evaluation score, wrist range of motion, radiological parameters (radial height, inclination, volar tilt, ulnar variance), and pinch strength. Patients treated with dual plating demonstrated significantly better Patient-Rated Wrist Evaluation scores at all follow-up points (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05) as well as improved radial height, inclination, volar tilt, wrist flexion, and grip strength. Pronation values were more favorable in the single-plating group across all follow-up time points, while supination values differed only at the 6-month assessment; overall function and radiological alignment otherwise appeared more favorable in the dual-plating group. In AO type C distal radius fractures with radial styloid involvement or severe comminution, dual plate fixation demonstrated improved functional recovery and maintenance of radiographic alignment. Supplementary radial column fixation may therefore represent an effective treatment strategy for these challenging fracture patterns, warranting further prospective investigation.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000050427","type":"journal-article","created":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T11:00:39Z","timestamp":1788606039000},"page":"e50427","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Does additional radial column plating improve clinical and radiological outcomes in distal radius fractures with radial styloid involvement or severe comminution?"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3021-0581","authenticated-orcid":false,"given":"Sabit Numan","family":"Kuyuba\u015fi","sequence":"first","affiliation":[{"name":"Department of Orthopedics and Traumatology, K\u00fctahya Health Sciences University, K\u00fctahya, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4333-0582","authenticated-orcid":false,"given":"S\u00fcleyman Kaan","family":"\u00d6ner","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Traumatology, K\u00fctahya Health Sciences University, K\u00fctahya, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5175-0600","authenticated-orcid":false,"given":"S\u00fcleyman","family":"Kozlu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Traumatology, K\u00fctahya Health Sciences University, K\u00fctahya, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7930-0775","authenticated-orcid":false,"given":"Bilgehan","family":"Ocak","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Traumatology, K\u00fctahya Health Sciences University, K\u00fctahya, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0117-9455","authenticated-orcid":false,"given":"Umur","family":"Batak","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Traumatology, K\u00fctahya Health Sciences University, K\u00fctahya, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260905","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1186\/s12891-017-1596-z","article-title":"Epidemiology and time trends of distal forearm fractures in adults - a study of 11.2 million person-years in Sweden.","volume":"18","author":"Jerrhag","year":"2017","journal-title":"BMC Musculoskelet Disord"},{"key":"R2-20260905","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1142\/S242483551640004X","article-title":"Pearls and pitfalls of the volar locking plating for distal radius fractures.","volume":"21","author":"Im","year":"2016","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"R3-20260905","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1016\/j.jhsa.2006.09.011","article-title":"Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: a biomechanical study in cadavers.","volume":"31","author":"Blythe","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R4-20260905","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1177\/1558944718760861","article-title":"Complications of radial column plating of the distal radius.","volume":"14","author":"Galle","year":"2019","journal-title":"Hand (N Y)"},{"key":"R5-20260905","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/j.injury.2012.04.022","article-title":"Orthogonal plating of intra-articular distal radius fractures with an associated radial column fracture via a single volar approach.","volume":"43","author":"Helmerhorst","year":"2012","journal-title":"Injury"},{"key":"R6-20260905","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/BTH.0b013e3181cae14d","article-title":"Radial column and volar plating (RCVP) for distal radius fractures with a radial styloid component or severe comminution.","volume":"14","author":"Tang","year":"2010","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R7-20260905","doi-asserted-by":"crossref","first-page":"120","DOI":"10.3944\/AOTT.2015.14.0208","article-title":"Validity and reliability of the Turkish \u201cPatient-Rated Wrist Evaluation\u201d questionnaire.","volume":"49","author":"Ozturk","year":"2015","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R8-20260905","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1302\/2046-3758.54.2000462","article-title":"Are validated outcome measures used in distal radial fractures truly valid? A critical assessment using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist.","volume":"5","author":"Kleinlugtenbelt","year":"2016","journal-title":"Bone Joint Res"},{"key":"R9-20260905","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/BTH.0b013e3181e1d2d5","article-title":"Exposure of distal radius fractures using a direct radial approach with mobilization of the superficial branch of the radial nerve.","volume":"14","author":"Pirela-Cruz","year":"2010","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R10-20260905","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1055\/s-0043-1774331","article-title":"Volar locking plate versus closed reduction and immobilization for distal radius fracture in the elderly: systematic review and meta-analysis of randomized controlled trials.","volume":"13","author":"Latypov","year":"2024","journal-title":"J Wrist Surg"},{"key":"R11-20260905","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1186\/s13018-020-01942-w","article-title":"A systematic review and meta-analysis of the pronator quadratus repair following volar plating of distal radius fractures.","volume":"15","author":"Lu","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R12-20260905","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/00130911-200006000-00007","article-title":"The double plating technique for distal radius fractures.","volume":"4","author":"Rikli","year":"2000","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R13-20260905","doi-asserted-by":"crossref","first-page":"971","DOI":"10.5435\/JAAOS-D-23-01169","article-title":"Complications of volar versus low-profile dorsal plating of distal radius fractures.","volume":"33","author":"Jiang","year":"2024","journal-title":"J Am Acad Orthop Surg"},{"key":"R14-20260905","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1016\/j.clinbiomech.2006.12.010","article-title":"Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture.","volume":"22","author":"Cheng","year":"2007","journal-title":"Clin Biomech (Bristol)"},{"key":"R15-20260905","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1097\/00130911-200112000-00004","article-title":"The extended flexor carpi radialis approach: a new perspective for the distal radius fracture.","volume":"5","author":"Orbay","year":"2001","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R16-20260905","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1186\/1749-799X-5-55","article-title":"Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique.","volume":"5","author":"Jacobi","year":"2010","journal-title":"J Orthop Surg Res"},{"key":"R17-20260905","doi-asserted-by":"crossref","first-page":"93","DOI":"10.12790\/ahm.21.0091","article-title":"The usefulness of radial column plate in distal radius fracture: indications and results.","volume":"26","author":"An","year":"2021","journal-title":"Arch Hand Microsurg"},{"key":"R18-20260905","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1007\/s00256-021-03985-4","article-title":"Diagnostic ultrasound of tendon injuries in the setting of distal radius fractures.","volume":"51","author":"Sun","year":"2022","journal-title":"Skeletal Radiol"},{"key":"R19-20260905","doi-asserted-by":"crossref","first-page":"108","DOI":"10.52312\/jdrs.2023.856","article-title":"Is tendinitis in volar plating related to the dorsally protruding screw length and its compartment?","volume":"34","author":"Alic","year":"2023","journal-title":"Jt Dis Relat Surg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050427","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T11:00:41Z","timestamp":1788606041000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050427"}},"subtitle":["A retrospective cohort study with 2-year follow-up"],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":19,"journal-issue":{"issue":"36","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000050427","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"assertion":[{"value":"2025-06-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}