{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T19:00:24Z","timestamp":1790103624952,"version":"4.0.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"38","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9,18]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      This study aimed to evaluate the clinical performance of artificial intelligence (AI)-assisted measurement of thoracic aortic diameter on non-contrast computed tomography (NCCT). This single-center prospective study included 79 patients (mean age\u2005=\u200570\u2005\u00b1\u200513 standard deviation; 46 men) who underwent NCCT and arterial phase contrast-enhanced computed tomography (CECT) for evaluating aortic diseases between 2021 and 2022. Maximum diameters of 9 American Heart Association landmarks and the maximum ascending\/descending aorta were measured. Upper limits of the 95% confidence interval (CI) for the absolute difference in aortic diameter between the AI-assisted\/manual method on NCCT and the manual method on CECT (Diff\n                      <jats:sub>AI-assisted<\/jats:sub>\n                      \/Diff\n                      <jats:sub>manual<\/jats:sub>\n                      ) were calculated and compared using a predefined cutoff of 1.5\u2009mm. Evaluation times were also compared. No significant difference was found between per-patient Diff\n                      <jats:sub>AI-assisted<\/jats:sub>\n                      and Diff\n                      <jats:sub>manual<\/jats:sub>\n                      (1.10\u2009mm; 95% CI\u2005=\u20051.03\u20131.18 vs 1.03\u2009mm; 95% CI\u2005=\u20050.95\u20131.11,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.058); the upper limit of the 95% CI was &lt;1.5\u2009mm. The upper limit of the 95% CI of the geometric mean Diff\n                      <jats:sub>AI-assisted<\/jats:sub>\n                      and Diff\n                      <jats:sub>manual<\/jats:sub>\n                      was also &lt;1.5\u2009mm at each landmark. The median evaluation time of the AI-assisted method was shorter than that of the manual method (expert radiologist\u2005=\u2005272 seconds [interquartile range (IQR)\u2005=\u2005229\u2013313] vs 496 seconds [IQR\u2005=\u2005438\u2013550];\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.001, training radiologist: 304 seconds [IQR\u2005=\u2005257\u2013404] vs 710 seconds [IQR\u2005=\u2005563\u2013855];\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.001). AI-assisted thoracic aortic diameter measurement on NCCT was as accurate as manual measurement on CECT; its evaluation time was shorter than that of manual measurement on NCCT.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000050702","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:01:44Z","timestamp":1789750904000},"page":"e50702","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of clinical performance of artificial intelligence-assisted measurement of thoracic aortic diameter on non-contrast CT"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4457-3260","authenticated-orcid":false,"given":"Akiyoshi","family":"Suzuki","sequence":"first","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6305-1081","authenticated-orcid":false,"given":"Nobuo","family":"Tomizawa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kotaro","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"},{"name":"Department of Radiology, Kokura Memorial Hospital, Kitakyushu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichi","family":"Morita","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"},{"name":"Department of Radiology, The University of Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shohei","family":"Fujita","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"},{"name":"Department of Radiology, The University of Tokyo, Tokyo, Japan"},{"name":"Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuhiro","family":"Sano","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiaki","family":"Akashi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuo","family":"Nishizawa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiro","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiko","family":"Wada","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Endo","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Matsushita","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanako K.","family":"Kumamaru","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keiichi","family":"Funaki","sequence":"additional","affiliation":[{"name":"Digital & Automation Department, Siemens Healthcare K.K., Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Sperl","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging, Computed Tomography, Clinical Concepts, Siemens Healthineers AG, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoru","family":"Tabata","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeki","family":"Aoki","sequence":"additional","affiliation":[{"name":"Department of Radiology, Juntendo University Graduate School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260922","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1253\/circj.CJ-22-0794","article-title":"JCS\/JSCVS\/JATS\/JSVS 2020 guideline on diagnosis and treatment of aortic aneurysm and aortic dissection.","volume":"87","author":"Ogino","year":"2023","journal-title":"Circ J"},{"key":"R2-20260922","doi-asserted-by":"crossref","first-page":"e266","DOI":"10.1161\/CIR.0b013e3181d47d48","article-title":"2010 ACCF\/AHA\/AATS\/ACR\/ASA\/SCA\/SCAI\/SIR\/STS\/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease: a report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine.","volume":"121","author":"Hiratzka","year":"2010","journal-title":"Circulation"},{"key":"R3-20260922","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1038\/ncpcardio0937","article-title":"Etiology, pathogenesis and management of thoracic aortic aneurysm.","volume":"4","author":"Ince","year":"2007","journal-title":"Nat Clin Pract Cardiovasc Med"},{"key":"R4-20260922","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1001\/jama.280.22.1926","article-title":"Improved prognosis of thoracic aortic aneurysms: a population-based study.","volume":"280","author":"Clouse","year":"1998","journal-title":"JAMA"},{"key":"R5-20260922","doi-asserted-by":"crossref","first-page":"2873","DOI":"10.1093\/eurheartj\/ehu281","article-title":"2014 ESC Guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. The task force for the diagnosis and treatment of aortic diseases of the European Society of Cardiology (ESC).","volume":"35","author":"Erbel","year":"2014","journal-title":"Eur Heart J"},{"key":"R6-20260922","doi-asserted-by":"crossref","first-page":"e334","DOI":"10.1161\/CIR.0000000000001106","article-title":"2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association\/American College of Cardiology Joint Committee on Clinical Practice Guidelines.","volume":"146","author":"Isselbacher","year":"2022","journal-title":"Circulation"},{"key":"R7-20260922","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1002\/jmri.22016","article-title":"Measuring aortic diameter with different MR techniques: comparison of three-dimensional (3D) navigated steady-state free-precession (SSFP), 3D contrast-enhanced magnetic resonance angiography (CE-MRA), 2D T2 black blood, and 2D cine SSFP.","volume":"31","author":"Potthast","year":"2010","journal-title":"J Magn Reson Imaging"},{"key":"R8-20260922","doi-asserted-by":"crossref","first-page":"e210196","DOI":"10.1148\/ryai.210196","article-title":"Evaluating the performance of a convolutional neural network algorithm for measuring thoracic aortic diameters in a heterogeneous population.","volume":"4","author":"Monti","year":"2022","journal-title":"Radiol Artif Intell"},{"key":"R9-20260922","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1148\/radiol.2017161424","article-title":"What is the optimal abdominal aortic aneurysm sac measurement on CT images during follow-up after endovascular repair?","volume":"285","author":"Boos","year":"2017","journal-title":"Radiology"},{"key":"R11-20260922","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.jacc.2020.03.084","article-title":"Discrepancies in measurement of the thoracic aorta: JACC review topic of the week.","volume":"76","author":"Elefteriades","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"R12-20260922","doi-asserted-by":"crossref","first-page":"109424","DOI":"10.1016\/j.ejrad.2020.109424","article-title":"Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up.","volume":"134","author":"Rueckel","year":"2021","journal-title":"Eur J Radiol"},{"key":"R13-20260922","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1016\/j.ejvs.2021.07.013","article-title":"Pre-surgical and post-surgical aortic aneurysm maximum diameter measurement: full automation by artificial intelligence.","volume":"62","author":"Adam","year":"2021","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"R14-20260922","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.avsg.2021.12.008","article-title":"Automatic measurement of maximal diameter of abdominal aortic aneurysm on computed tomography angiography using artificial intelligence.","volume":"83","author":"Lareyre","year":"2022","journal-title":"Ann Vasc Surg"},{"key":"R15-20260922","doi-asserted-by":"crossref","first-page":"111067","DOI":"10.1016\/j.ejrad.2023.111067","article-title":"Validation of an AI-based algorithm for measurement of the thoracic aortic diameter in low-dose chest CT.","volume":"167","author":"Hamelink","year":"2023","journal-title":"Eur J Radiol"},{"key":"R16-20260922","doi-asserted-by":"crossref","first-page":"20220853","DOI":"10.1259\/bjr.20220853","article-title":"Assessing the role of an artificial intelligence assessment tool for thoracic aorta diameter on routine chest CT.","volume":"96","author":"Graby","year":"2023","journal-title":"Br J Radiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050702","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T18:03:02Z","timestamp":1790100182000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050702"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":15,"journal-issue":{"issue":"38","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000050702","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]},"assertion":[{"value":"2024-12-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-31","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}