{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T19:53:48Z","timestamp":1790970828122,"version":"4.1.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"40","license":[{"start":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:00:00Z","timestamp":1790899200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10,2]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      This study aimed to assess how optic disc (OD) size influences structural and functional tests in patients with glaucoma with small and normal-sized discs and to compare the sensitivities of these tests. The study comprised 182 eyes, including 109 eyes of 73 patients diagnosed with glaucoma and 73 eyes of 41 healthy subjects. Eyes were classified according to OD size as either small (&lt;1.6\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      ) or normal (1.6\u20132.1\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      ). Optic nerve head parameters, peripapillary retinal nerve fiber layer (RNFL) thickness, and macular ganglion cell analysis were assessed using Cirrus 4000 spectral-domain optical coherence tomography. The sensitivities of RNFL, macular ganglion cell\u2013inner plexiform layer (GCIPL), and visual field parameters were evaluated using logistic receiver operating characteristic regression analysis. The mean ages of the patients and controls were 65.48\u2005\u00b1\u20057.94 years and 65.22\u2005\u00b1\u20056.55 years, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.859). The mean disc diameter was 1.48\u2005\u00b1\u20050.11\u2009mm in the small-disc group and 1.86\u2005\u00b1\u20050.16\u2009mm in the normal-disc group. The mean deviation values were \u22125.52\u2005\u00b1\u20054.81 and \u22124.54\u2005\u00b1\u20053.73 in the small- and normal-disc groups, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.268). Among patients with glaucoma and small ODs, GCIPL parameters (mean, minimum, superior, and inferior hemifield values) demonstrated greater sensitivity than RNFL parameters. In contrast, RNFL parameters (average, superior, inferior, and corresponding hemifield values) showed greater sensitivity than GCIPL parameters in patients with normal-sized ODs. Macular structural parameters demonstrated higher sensitivity for glaucoma diagnosis in patients with small ODs. However, a comprehensive assessment integrating both macular and peripapillary structural parameters may improve diagnostic accuracy by providing complementary information in these patients.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000050866","type":"journal-article","created":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T19:01:59Z","timestamp":1790967719000},"page":"e50866","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Challenges in glaucoma diagnosis in small optic discs"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5966-5336","authenticated-orcid":false,"given":"Serap","family":"Yildiz","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Atat\u00fcrk Training and Research Hospital, \u0130zmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4057-3984","authenticated-orcid":false,"given":"Seyda","family":"Ugurlu Karadeniz","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, \u0130zmir Katip Celebi University, Atat\u00fcrk Training and Research Hospital, \u0130zmir, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261002","doi-asserted-by":"crossref","first-page":"2183","DOI":"10.1016\/S0140-6736(17)31469-1","article-title":"Glaucoma.","volume":"390","author":"Jonas","year":"2017","journal-title":"Lancet"},{"key":"R2-20261002","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1136\/bjophthalmol-2016-308957","article-title":"The use of Bruch\u2019s membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs.","volume":"101","author":"Enders","year":"2017","journal-title":"Br J Ophthalmol"},{"key":"R3-20261002","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1038\/s41598-021-80993-3","article-title":"An objective structural and functional reference standard in glaucoma.","volume":"11","author":"Mariottoni","year":"2021","journal-title":"Sci Rep"},{"key":"R4-20261002","doi-asserted-by":"crossref","first-page":"5853","DOI":"10.1167\/iovs.12-10414","article-title":"Determinants of ganglion cell-inner plexiform layer thickness measured by high-definition optical coherence tomography.","volume":"53","author":"Koh","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R5-20261002","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1136\/bjo.2004.052498","article-title":"Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study.","volume":"89","author":"Savini","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"R6-20261002","first-page":"807","article-title":"Optic disc size and progression of visual field damage in patients with normal-tension glaucoma.","volume":"7","author":"Hayamizu","year":"2013","journal-title":"Clin Ophthalmol"},{"key":"R7-20261002","doi-asserted-by":"crossref","first-page":"4990","DOI":"10.1167\/iovs.11-8214","article-title":"Does optic nerve head size variation affect circumpapillary retinal nerve fiber layer thickness measurement by optical coherence tomography?","volume":"53","author":"Huang","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R8-20261002","doi-asserted-by":"crossref","first-page":"266","DOI":"10.3390\/diagnostics13020266","article-title":"Ganglion cell complex analysis: correlations with retinal nerve fiber layer on optical coherence tomography.","volume":"13","author":"Ghita","year":"2023","journal-title":"Diagnostics (Basel)"},{"key":"R9-20261002","first-page":"2213","article-title":"Relationship between electrophysiological, psychophysical, and anatomical measurements in glaucoma.","volume":"43","author":"Garway-Heath","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R10-20261002","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s12886-017-0419-1","article-title":"Ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis.","volume":"17","author":"Seo","year":"2017","journal-title":"BMC Ophthalmol"},{"key":"R11-20261002","first-page":"1333","article-title":"Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma.","volume":"5","author":"Cordeiro","year":"2011","journal-title":"Clin Ophthalmol"},{"key":"R12-20261002","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1007\/s00347-021-01363-y","article-title":"Relative micro- and macrodiscs \u2013 a challenge in optical coherence tomography-based glaucoma diagnostics?.","volume":"118","author":"Mardin","year":"2021","journal-title":"Ophthalmologe"},{"key":"R13-20261002","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1038\/eye.2017.306","article-title":"Bruch\u2019s membrane opening-based optical coherence tomography of the optic nerve head: a useful diagnostic tool to detect glaucoma in macrodiscs.","volume":"32","author":"Enders","year":"2018","journal-title":"Eye (Lond)"},{"key":"R14-20261002","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/IJG.0000000000000574","article-title":"Optic nerve head histopathology in high axial myopia.","volume":"26","author":"Jonas","year":"2017","journal-title":"J Glaucoma"},{"key":"R15-20261002","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1136\/bjophthalmol-2011-301021","article-title":"Glaucoma discrimination of segmented cirrus spectral domain optical coherence tomography (SD-OCT) macular scans.","volume":"96","author":"Kotowski","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"R16-20261002","doi-asserted-by":"crossref","first-page":"8323","DOI":"10.1167\/iovs.11-7962","article-title":"Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma.","volume":"52","author":"Mwanza","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R17-20261002","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1167\/iovs.10-5546","article-title":"Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma.","volume":"52","author":"Rao","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R19-20261002","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1016\/S0161-6420(90)32434-X","article-title":"Glaucomatous optic nerve atrophy in small discs with low cup-to-disc ratios.","volume":"97","author":"Jonas","year":"1990","journal-title":"Ophthalmology"},{"key":"R20-20261002","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2018\/8941489","article-title":"A small disc area is a risk factor for visual field loss progression in primary open-angle glaucoma: the glaucoma stereo analysis study.","volume":"2018","author":"Kitaoka","year":"2018","journal-title":"J Ophthalmol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050866","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T19:02:02Z","timestamp":1790967722000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050866"}},"subtitle":["An OCT-based analysis"],"short-title":[],"issued":{"date-parts":[[2026,10,2]]},"references-count":19,"journal-issue":{"issue":"40","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000050866","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,2]]},"assertion":[{"value":"2025-12-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}