{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T06:25:02Z","timestamp":1794983102225,"version":"4.9.1"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"42","license":[{"start":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T00:00:00Z","timestamp":1792108800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10,16]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      Biodegradable pins are increasingly used in the treatment of lateral condylar fractures of the humerus (LCFH) in children, but the strength of the biodegradable pin is weaker than that of K-wire. However, to enhance the stability of LCFH fixed by biodegradable pins, absorbable tension band wiring is often combined with the application, yet high-quality comparative evidence verifying the clinical value of this auxiliary reinforcement remains lacking. This study aimed to compare and analyze whether auxiliary absorbable tension band wiring has clinical significance for Weiss type III LCFH and to clarify whether additional tension band fixation is clinically necessary in reducing postoperative complications and improving fracture stability. This study enrolled 96 children with Weiss type III LCFH admitted between January 2017 and September 2019. The patients were divided into 2 groups: A (fixed by 3 biodegradable pins alone, n\u2005=\u200545) and B (fixed by 3 biodegradable pins and combined with the application of absorbable figure-of-eight tension band wiring, n\u2005=\u200551). Preoperative, intraoperative, and postoperative indicators, including age, sex, operation time, intraoperative blood loss, fracture healing time, elbow functional recovery time, and postoperative complications, were compared between the 2 groups. Postoperative elbow function was assessed by using the Flynn grading system. All radiographic measurements and functional evaluations were performed by 2 calibrated orthopedic surgeons with excellent inter-rater reliability. Sample size calculations were performed before data collection to guarantee statistical validity. There were no significant differences in age, sex, injured side, preoperative fracture displacement, operation duration, intraoperative blood loss, fracture healing time, elbow functional recovery time, or Flynn functional grading (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&gt;\u2005.05). Complete fracture union was observed in all patients, and no adverse complications, such as wound infection, bone nonunion, osteonecrosis, or elbow deformity, occurred in either group. Absorbable tension band wiring reinforcement is not required after biodegradable pin fixation in the treatment of LCFH in children.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000050972","type":"journal-article","created":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T18:00:49Z","timestamp":1792173649000},"page":"e50972","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Biodegradable pins fixation for lateral condylar fracture of the humerus in children"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-5647-7171","authenticated-orcid":false,"given":"Lifei","family":"Dong","sequence":"first","affiliation":[{"name":"Pediatric Orthopedic Ward, Xingtai City Orthopedics Hospital, Xingtai City, Hebei Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dingding","family":"Jia","sequence":"additional","affiliation":[{"name":"Pediatric Orthopedic Ward, Xingtai City Orthopedics Hospital, Xingtai City, Hebei Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liyuan","family":"Hao","sequence":"additional","affiliation":[{"name":"Pediatric Orthopedic Ward, Xingtai City Orthopedics Hospital, Xingtai City, Hebei Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenyu","family":"Chen","sequence":"additional","affiliation":[{"name":"Pediatric Orthopedic Ward, Xingtai City Orthopedics Hospital, Xingtai City, Hebei Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiuyu","family":"Fan","sequence":"additional","affiliation":[{"name":"Pediatric Orthopedic Ward, Xingtai City Orthopedics Hospital, Xingtai City, Hebei Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Na","family":"Li","sequence":"additional","affiliation":[{"name":"Pediatric Orthopedic Ward, Xingtai City Orthopedics Hospital, Xingtai City, Hebei Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20261118","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1302\/1863-2548.12.170090","article-title":"Cannulated screw versus Kirschner-wire fixation for Milch II lateral condyle fractures in a paediatric sawbone model: a biomechanical comparison.","volume":"12","author":"Franks","year":"2018","journal-title":"J Child Orthop"},{"key":"R3-20261118","doi-asserted-by":"crossref","first-page":"401","DOI":"10.3109\/17453679508995573","article-title":"Surgery for nonunion of the lateral humeral condyle in children 6 cases followed for 1-9 years.","volume":"66","author":"De Boeck","year":"1995","journal-title":"Acta Orthop Scand"},{"key":"R5-20261118","doi-asserted-by":"crossref","first-page":"86941","DOI":"10.1155\/2013\/869418","article-title":"Lateral condyle fracture of the humerus in children treated with bioabsorbable materials.","volume":"2013","author":"Andrey","year":"2013","journal-title":"Sci World J"},{"key":"R6-20261118","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s11832-011-0358-y","article-title":"Exposed versus buried wires for fixation of lateral humeral condyle fractures in children: a comparison of safety and efficacy.","volume":"5","author":"Chan","year":"2011","journal-title":"J Child Orthop"},{"key":"R7-20261118","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.5435\/JAAOS-D-17-00815","article-title":"Current concepts in the treat- ment of lateral condyle fractures in children.","volume":"28","author":"Abzug","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"key":"R9-20261118","first-page":"1","article-title":"Percutaneous K wire fixation in pediatric lateral condylar fractures of humerus: a prospective study.","volume":"62","author":"Lal Sahu","year":"2018","journal-title":"Rev Esp Cir Ortop Traumatol"},{"key":"R10-20261118","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1097\/BPO.0b013e3181558ac5","article-title":"Arthroscopically-assisted treatment of pediatric lateral humeral condyle fractures.","volume":"27","author":"Hausman","year":"2007","journal-title":"J Pediatr Orthop"},{"key":"R11-20261118","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1007\/s00264-011-1452-y","article-title":"Comparison of Kirschner wires and AO cannulated screw internal fixation for displaced lateral humeral condyle fracture in children.","volume":"36","author":"Li","year":"2012","journal-title":"Int Orthop"},{"key":"R12-20261118","doi-asserted-by":"crossref","first-page":"1","DOI":"10.12968\/hmed.2020.0733","article-title":"Management of lateral condyle fractures of the humerus in children.","volume":"82","author":"Kim","year":"2021","journal-title":"Br J Hosp Med (Lond)"},{"key":"R13-20261118","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1142\/S2424835521500211","article-title":"Characteristics of cubitus varus deformity after lateral condylar fracture of the humerus.","volume":"26","author":"Takagi","year":"2021","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"R14-20261118","doi-asserted-by":"crossref","first-page":"52","DOI":"10.5606\/ehc.2018.58165","article-title":"Basic principles of fracture treatment in children.","volume":"29","author":"\u00d6mero\u011flu","year":"2018","journal-title":"Eklem Hastalik Cerrahisi"},{"key":"R15-20261118","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1097\/BPO.0b013e3181b2842c","article-title":"A new classification system predictive of complications in surgically treated pediatric humeral lateral condyle fractures.","volume":"29","author":"Weiss","year":"2009","journal-title":"J Pediatr Orthop"},{"key":"R16-20261118","first-page":"98","article-title":"Clinical outcomes of absorbable tension band combined with biodegradable pins for pediatric humeral lateral condyle fractures.","volume":"6","author":"Wang","year":"2023","journal-title":"Chin J Pediatr Orthop"},{"key":"R17-20261118","first-page":"412","article-title":"Biomechanical performance of absorbable implants for pediatric elbow intra-articular fractures.","volume":"31","author":"Smith","year":"2022","journal-title":"J Pediatr Orthop B"},{"key":"R18-20261118","first-page":"1489","article-title":"Long-term follow-up of PLLA absorbable fixation in children elbow fractures.","volume":"13","author":"Zhang","year":"2021","journal-title":"Orthop Surg"},{"key":"R19-20261118","first-page":"167","article-title":"Simplified absorbable pin fixation without tension band for displaced lateral condylar fractures in children.","volume":"15","author":"Liu","year":"2024","journal-title":"J Clin Orthop Trauma"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050972","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T06:01:07Z","timestamp":1794981667000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000050972"}},"subtitle":["A retrospective study of biodegradable pin fixation combined with versus without absorbable tension band wiring"],"short-title":[],"issued":{"date-parts":[[2026,10,16]]},"references-count":16,"journal-issue":{"issue":"42","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000050972","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,16]]},"assertion":[{"value":"2025-03-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}