{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T23:06:18Z","timestamp":1791846378488,"version":"4.3.4"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1097\/mnm.0000000000000765","type":"journal-article","created":{"date-parts":[[2017,10,3]],"date-time":"2017-10-03T20:02:05Z","timestamp":1507060925000},"page":"1047-1054","source":"Crossref","is-referenced-by-count":35,"title":["Dual-isotope subtraction SPECT-CT in parathyroid localization"],"prefix":"10.1097","volume":"38","author":[{"given":"Anna-May","family":"Woods","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison A.","family":"Bolster","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sai","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fat-Wui","family":"Poon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Colville","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Shand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James B.","family":"Neilly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-6-20210212","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/00006231-200302000-00002","article-title":"Trends in surgical techniques","volume":"24","author":"Thomas","year":"2003","journal-title":"Nucl Med Commun"},{"key":"R2-6-20210212","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1097\/MNM.0b013e32835710b6","article-title":"Preoperative 99mTc-sestamibi scintigraphy in patients with primary hyperthyroidism and concomitant nodular goitre: comparison of SPECT-CT, SPECT and planar imaging","volume":"33","author":"Shafiei","year":"2012","journal-title":"Nucl Med Commun"},{"key":"R3-6-20210212","first-page":"1801","article-title":"Detection and localisation of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase srudy)","volume":"33","author":"Taillefer","year":"1992","journal-title":"J Nucl Med"},{"key":"R4-6-20210212","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1097\/00003072-199608000-00002","article-title":"Comparison of Tc-99m MIBI and Tl-201\/Tc-99m pertechnetate for diagnosis of primary parahyperthyroidism","volume":"21","author":"Rauth","year":"1996","journal-title":"Clin Nucl Med"},{"key":"R5-6-20210212","first-page":"37","article-title":"Sestamibi parathyroid scanning and preoperative localisationstudies for patients with recurrent\/persistent hyperparathyroidism of significant comorbid conditions: development of an optimal localisation strategy","volume":"63","author":"Peeler","year":"1997","journal-title":"Am Surg"},{"key":"R6-6-20210212","doi-asserted-by":"crossref","first-page":"1817","DOI":"10.1007\/s002590100627","article-title":"Technitium-99m tetrofosmin for parathyroid scintigraphy: a direct comparison with Tc99m-MIBI, 201Tl, MRI and US","volume":"28","author":"Wakamatsu","year":"2001","journal-title":"Eur J Nucl Med"},{"key":"R7-6-20210212","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1097\/01.MLG.0000203411.53666.AD","article-title":"Impact of gland morphology and concomitant thyroid nodules on preoperative localisation of parathyroid adenomas","volume":"116","author":"Erbil","year":"2006","journal-title":"Laryngoscope"},{"key":"R8-6-20210212","first-page":"241","article-title":"Rapid washout of technetium-99m-MIBI from a large parathyroid adenoma","volume":"36","author":"B\u00e9nard","year":"1995","journal-title":"J Nucl Med"},{"key":"R9-6-20210212","first-page":"439","article-title":"Parathyroid adenomas with rapid washout: two case reports","volume":"21","author":"Calendini-Viallet","year":"1997","journal-title":"Med Nucl"},{"key":"R10-6-20210212","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1097\/00003072-200112000-00001","article-title":"Diagnostic dilemmas in parathyroid scintigraphy","volume":"26","author":"Krausz","year":"2001","journal-title":"Clin Nucl Med"},{"key":"R11-6-20210212","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1259\/bjr\/44399050","article-title":"Technetium-99m sestamibi scintigraphy and helical CT together in patients with primary hyperparathyroidism: a prospective clinical study","volume":"77","author":"Lumachi","year":"2004","journal-title":"Br J Radiol"},{"key":"R12-6-20210212","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1007\/s00268-015-3389-6","article-title":"A multimodality protocol, 123I\/99mTc-sestamibi, SPECT, and SPECT\/CT in primary hyperparathyroidism adds limited benefit for pre-operative surgery","volume":"40","author":"Lee","year":"2016","journal-title":"World J Surg"},{"key":"R13-6-20210212","first-page":"1100","article-title":"Parathyroid imaging using simultaneous double-window recording of technetium-99m-sestamibi and iodine-123","volume":"39","author":"Hindi\u00e9","year":"1998","journal-title":"J Nucl Med"},{"key":"R14-6-20210212","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1007\/s00259-002-0944-9","article-title":"Parathyroid 99mTc-sestamibi scintigraphy: dual-tracer subtraction is superior to double phase washout","volume":"29","author":"Leslie","year":"2002","journal-title":"Eur J Nucl Med"},{"key":"R15-6-20210212","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/00006231-200307000-00004","article-title":"Parathyroid scintigraphy with 99mTc-MIBI and 123I subtraction: a comparison with magnetic resonance imaging and ultrasonography","volume":"24","author":"Wakamatsu","year":"2003","journal-title":"Nucl Med Commun"},{"key":"R17-6-20210212","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1007\/s13139-016-0438-5","article-title":"Usefulness of SPECT\/CT in parathyroid lesion detection in patients with thyroid parenchymal 99m-Tc-sestamibi retention","volume":"51","author":"Hwang","year":"2017","journal-title":"Nucl Med Mol Imaging"},{"key":"R18-6-20210212","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1046\/j.1365-2168.1998.00942.x","article-title":"Radionuclide scanning in parathyroid diseases","volume":"85","author":"Pattou","year":"1998","journal-title":"Br J Surg"},{"key":"R19-6-20210212","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/00003072-199704000-00001","article-title":"Preliminary experience with double-phase SPECT using Tc-99m sestamibi in patients with hyperparathyroidism","volume":"22","author":"Neumann","year":"1997a","journal-title":"Clin Nucl Med"},{"key":"R20-6-20210212","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.2214\/ajr.169.6.9393188","article-title":"Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidism","volume":"169","author":"Neumann","year":"1997b","journal-title":"Am J Roentgenol"},{"key":"R21-6-20210212","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1053\/j.semnuclmed.2006.03.003","article-title":"Parathyroid imaging: how good is it and how should it be done?","volume":"36","author":"Kettle","year":"2006","journal-title":"Semin Nucl Med"},{"key":"R22-6-20210212","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/RLU.0000000000000272","article-title":"Dual-isotope 99mTc-MIBI\/123I parathyroid scintigraphy in primary hyperparathyroidism comparison of subtraction SPECT\/CT and pinhole planar scan","volume":"39","author":"Hassler","year":"2014","journal-title":"Clin Nucl Med"},{"key":"R23-6-20210212","first-page":"477","article-title":"The value of parathyroid I-123\/Tc-99m subtraction SPECT\/CT in primary hyperparathyroidism","volume":"55","author":"Korsten","year":"2014","journal-title":"J Nucl Med"}],"container-title":["Nuclear Medicine Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000000765","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T23:36:20Z","timestamp":1620948980000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00006231-201712000-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":22,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/mnm.0000000000000765","relation":{},"ISSN":["0143-3636"],"issn-type":[{"value":"0143-3636","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12]]}}}