{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T08:42:01Z","timestamp":1758703321566,"version":"3.43.0"},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Ventilation-perfusion (V\/Q) scan coupled with single photon emission computed tomography (SPECT) is commonly used for the diagnosis of pulmonary embolism (PE). An abnormal chest x-ray (CXR) is deemed to hinder the interpretation of V\/Q scan and therefore a normal CXR is recommended prior to V\/Q scan.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Aims<\/jats:title>\n            <jats:p>To determine if an abnormal CXR impacted on V\/Q scan interpretation and subsequent management.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A retrospective cohort analysis of all patients who underwent a V\/Q scan for diagnosis of suspected acute PE between March 2016 and 2022 was performed. CXR reports were reviewed and classified as normal or abnormal. Low-dose computerised tomography was routinely performed in patients above the age of 70. Data regarding V\/Q scan results and subsequent management including initiation of anticoagulation for PE or further diagnostic investigations were collected.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A total of 340 cases were evaluated. Of the positive V\/Q scans (92\/340), 98.3% of the normal CXR were anticoagulated compared to 100% of the abnormal CXR group. Of the negative V\/Q scans (239\/340), no cases were started on anticoagulation and no further investigations were performed across both normal and abnormal CXR groups. Indeterminate results occurred in only 9 cases with no significant difference in management between normal and abnormal CXR groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>An abnormal CXR does not affect the reliability of V\/Q scan interpretation in the diagnosis of PE when coupled with SPECT. Unless clinically indicated, the mandate by clinical society guidelines for a normal CXR prior to V\/Q should be revisited.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mnm.0000000000001802","type":"journal-article","created":{"date-parts":[[2024,1,22]],"date-time":"2024-01-22T05:00:08Z","timestamp":1705899608000},"page":"181-187","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Ventilation-perfusion scan for diagnosing pulmonary embolism: do chest x-rays matter?"],"prefix":"10.1097","volume":"45","author":[{"given":"Thomas J.","family":"Conrad","sequence":"first","affiliation":[{"name":"Internal Medicine Services, The Prince Charles Hospital, Metro North Health, Brisbane"},{"name":"Internal Medicine Services, Toowoomba Hospital, Darling Downs Health, Toowoomba, Queensland, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Han X.","family":"Lau","sequence":"additional","affiliation":[{"name":"Internal Medicine Services, The Prince Charles Hospital, Metro North Health, Brisbane"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie T.","family":"Yerkovich","sequence":"additional","affiliation":[{"name":"Child and Maternal Health Division, Menzies School of Health Research, Charles Darwin University, Darwin, Northern Territory, Australia"},{"name":"Australian Centre for Health Services Innovation, Queensland University of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alaa","family":"Alghamry","sequence":"additional","affiliation":[{"name":"Internal Medicine Services, The Prince Charles Hospital, Metro North Health, Brisbane"},{"name":"Faculty of Medicine, The University of Queensland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph C.","family":"Lee","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, The University of Queensland"},{"name":"Department of Medical Imaging, The Prince Charles Hospital, Metro North Health, Brisbane, Queensland, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,1,19]]},"reference":[{"key":"R1-20250807","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/0020-708X(67)90101-9","article-title":"Technetium-99m macroaggregated albumin: a new lung scanning agent.","volume":"18","author":"Peterson","year":"1967","journal-title":"Int J Appl Radiat Isotope"},{"key":"R2-20250807","first-page":"45","article-title":"Using Xenon-133 and a scintillation camera to evaluate pulmonary function.","volume":"9","author":"Loken","year":"1968","journal-title":"J Nucl Med"},{"key":"R3-20250807","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/00004728-198501000-00015","article-title":"SPECT quantification of technetium-99m microspheres within the canine lung.","volume":"9","author":"Osborne","year":"1985","journal-title":"J Comput Assist Tomogr"},{"key":"R4-20250807","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1259\/0007-1285-57-674-141","article-title":"Ventilation perfusion ratios of the normal supine lung using emission tomography.","volume":"57","author":"Lavender","year":"1984","journal-title":"Br J Radiol"},{"key":"R5-20250807","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1136\/thx.41.7.542","article-title":"Tomography of regional ventilation and perfusion using krypton 81m in normal subjects and asthmatic patients.","volume":"41","author":"Orphanidou","year":"1986","journal-title":"Thorax"},{"key":"R6-20250807","doi-asserted-by":"crossref","first-page":"2753","DOI":"10.1001\/jama.1990.03440200057023","article-title":"PIOPED: value of the ventilation\/perfusion scan in acute pulmonary embolism Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED).","volume":"263","year":"1990","journal-title":"JAMA"},{"key":"R7-20250807","first-page":"1119","article-title":"Ventilation-perfusion scintigraphy in the PIOPED study Part II Evaluation of the scintigraphic criteria and interpretations.","volume":"34","author":"Gottschalk","year":"1993","journal-title":"J Nucl Med"},{"key":"R8-20250807","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1164\/ajrccm.154.5.8912753","article-title":"Value of perfusion lung scan in the diagnosis of pulmonary embolism: results of the Prospective Investigative Study of Acute Pulmonary Embolism Diagnosis (PISA-PED).","volume":"154","author":"Miniati","year":"1996","journal-title":"Am J Respir Crit Care Med"},{"key":"R9-20250807","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.1148\/rg.2021210060","article-title":"Ventilation-perfusion scan: a primer for practicing radiologists.","volume":"41","author":"Derenoncourt","year":"2021","journal-title":"Radiographics"},{"key":"R10-20250807","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.2214\/ajr.133.6.1033","article-title":"Ventilation-perfusion studies in suspected pulmonary embolism.","volume":"133","author":"Biello","year":"1979","journal-title":"Am J Roentgenol"},{"key":"R11-20250807","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1053\/j.semnuclmed.2019.07.004","article-title":"A brief history of lung ventilation and perfusion imaging over the 50-year tenure of the editors of seminars in nuclear medicine.","volume":"50","author":"Bailey","year":"2020","journal-title":"Semin Nucl Med"},{"key":"R12-20250807","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1097\/00006231-200211000-00011","article-title":"Is a lung perfusion scan obtained by using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism?","volume":"23","author":"Collart","year":"2002","journal-title":"Nucl Med Commun"},{"key":"R13-20250807","doi-asserted-by":"crossref","first-page":"489","DOI":"10.2214\/AJR.16.17195","article-title":"Current status of ventilation-perfusion scintigraphy for suspected pulmonary embolism.","volume":"208","author":"Metter","year":"2017","journal-title":"AJR Am J Roentgenol"},{"key":"R14-20250807","doi-asserted-by":"crossref","first-page":"1741","DOI":"10.2967\/jnumed.108.052217","article-title":"Sensitivity and specificity of perfusion scintigraphy combined with chest radiography for acute pulmonary embolism in PIOPED II.","volume":"49","author":"Sostman","year":"2008","journal-title":"J Nucl Med"},{"key":"R15-20250807","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1016\/0002-9149(91)90875-L","article-title":"Usefulness of noninvasive diagnostic tools for diagnosis of acute pulmonary embolism in patients with a normal chest radiograph.","volume":"67","author":"Stein","year":"1991","journal-title":"Am J Cardiol"},{"key":"R16-20250807","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1164\/rccm.201108-1575ST","article-title":"ATS\/STR Committee on Pulmonary Embolism in Pregnancy An official American Thoracic Society\/Society of Thoracic Radiology clinical practice guideline: evaluation of suspected pulmonary embolism in pregnancy.","volume":"184","author":"Leung","year":"2011","journal-title":"Am J Respir Crit Care Med"},{"key":"R17-20250807","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1093\/eurheartj\/ehz405","article-title":"ESC Scientific Document Group 2019 ESC Guidelines for the diagnosis and management of acute pulmonary embolism developed in collaboration with the European Respiratory Society (ERS).","volume":"41","author":"Konstantinides","year":"2020","journal-title":"Eur Heart J"},{"key":"R18-20250807","doi-asserted-by":"crossref","first-page":"392","DOI":"10.2214\/AJR.09.2499","article-title":"Success of a safe and simple algorithm to reduce use of CT pulmonary angiography in the emergency department.","volume":"194","author":"Stein","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"R19-20250807","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.2214\/AJR.04.0770","article-title":"Female breast radiation exposure during CT pulmonary angiography.","volume":"185","author":"Parker","year":"2005","journal-title":"AJR Am J Roentgenol"},{"key":"R20-20250807","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1148\/rg.293085226","article-title":"Imaging pregnant patients with suspected pulmonary embolism: what the radiologist needs to know.","volume":"29","author":"Pahade","year":"2009","journal-title":"Radiographics"},{"key":"R21-20250807","first-page":"1501","article-title":"Tomographic imaging in the diagnosis of pulmonary embolism: a comparison between V\/Q lung scintigraphy in SPECT technique and multislice spiral CT.","volume":"45","author":"Reinartz","year":"2004","journal-title":"J Nucl Med"},{"key":"R22-20250807","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1053\/j.semnuclmed.2008.06.002","article-title":"Enhancing lung scintigraphy with single-photon emission computed tomography.","volume":"38","author":"Roach","year":"2008","journal-title":"Semin Nucl Med"},{"key":"R23-20250807","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s00259-006-0194-3","article-title":"Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation\/perfusion scintigraphy: initial experience and potential benefit.","volume":"34","author":"Harris","year":"2007","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R24-20250807","doi-asserted-by":"crossref","first-page":"3226","DOI":"10.1182\/bloodadvances.2018024828","article-title":"American Society of Hematology 2018 guidelines for management of venous thromboembolism: diagnosis of venous thromboembolism.","volume":"2","author":"Lim","year":"2018","journal-title":"Blood Adv"},{"key":"R25-20250807","first-page":"584","article-title":"Abnormal chest radiographs preceding VQ scans: does the type of abnormality matter?","volume":"38","author":"Lakhanpal","year":"2011","journal-title":"Eur Respir J"},{"key":"R26-20250807","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1097\/00006231-200404000-00073","article-title":"With an abnormal chest X-ray, is there any point in performing V\/Q scintigraphy?","volume":"25","author":"Chilab","year":"2004","journal-title":"Nucl Med Commun"},{"key":"R27-20250807","doi-asserted-by":"crossref","first-page":"82","DOI":"10.5694\/mja2.50233","article-title":"Pulmonary embolism: update on diagnosis and management.","volume":"211","author":"Kruger","year":"2019","journal-title":"Med J Aust"},{"key":"R28-20250807","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1097\/MNM.0000000000001606","article-title":"Ventilation perfusion reporting: the utility of a prior chest radiograph in interpreting ventilation perfusion scans.","volume":"43","author":"Rabinowicz","year":"2022","journal-title":"Nucl Med Commun"},{"key":"R29-20250807","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1007\/s00259-009-1169-y","article-title":"EANM guidelines for ventilation\/perfusion scintigraphy: Part 2 Algorithms and clinical considerations for diagnosis of pulmonary emboli with V\/P(SPECT) and MDCT.","volume":"36","author":"Bajc","year":"2009","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R30-20250807","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1111\/1754-9485.12471","article-title":"SPECT-CT\/VQ versus CTPA for diagnosing pulmonary embolus and other lung pathology: Pre-existing lung disease should not be a contraindication.","volume":"60","author":"Bhatia","year":"2016","journal-title":"J Med Imaging Radiat Oncol"},{"key":"R31-20250807","first-page":"168","article-title":"Symptomatic subsegmental versus more central pulmonary embolism: Clinical outcomes during anticoagulation.","volume":"18","author":"Fern\u00e1ndez-Capit\u00e1n","year":"2020","journal-title":"Res Pract Thromb Haemost"},{"key":"R32-20250807","doi-asserted-by":"crossref","first-page":"29","DOI":"10.7326\/M21-2981","article-title":"Risk for recurrent venous thromboembolism in patients with subsegmental pulmonary embolism managed without anticoagulation: a multicenter prospective cohort study.","volume":"175","author":"Le Gal","year":"2022","journal-title":"Ann Intern Med"},{"key":"R33-20250807","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.mayocpiqo.2020.02.002","article-title":"Adverse events and mortality in anticoagulated patients with different categories of pulmonary embolism.","volume":"5","author":"Cambron","year":"2020","journal-title":"Mayo Clin Proc Innov Qual Outcomes"},{"key":"R34-20250807","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1177\/02676591221075934","article-title":"Head-to-head comparison of ventilation\/perfusion single photon emission computed tomography\/computed tomography and multidetector computed tomography angiography for the detection of acute pulmonary embolism in clinical practice.","volume":"38","author":"Martins","year":"2022","journal-title":"Perfusion"},{"key":"R35-20250807","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1148\/radiol.12121823","article-title":"Intravenous contrast material-induced nephropathy: causal or coincident phenomenon?","volume":"267","author":"McDonald","year":"2013","journal-title":"Radiology"},{"key":"R36-20250807","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1148\/radiol.13122276","article-title":"Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate.","volume":"268","author":"Davenport","year":"2013","journal-title":"Radiology"},{"key":"R37-20250807","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.2214\/AJR.14.14259","article-title":"Contrast media controversies in 2015: imaging patients with renal impairment or risk of contrast reaction.","volume":"204","author":"Davenport","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"R38-20250807","doi-asserted-by":"crossref","first-page":"188","DOI":"10.2214\/AJR.19.21424","article-title":"Influence of clinical factors on risk of contrast-induced nephrotoxicity from IV iodinated low-osmolality contrast material in patients with a low estimated glomerular filtration rate.","volume":"213","author":"Ellis","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"R39-20250807","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1097\/MNM.0b013e32827a8e99","article-title":"Prospective evaluation of the negative predictive value of V\/Q SPECT using 99mTc-Technegas.","volume":"28","author":"Leblanc","year":"2007","journal-title":"Nucl Med Commun"},{"key":"R40-20250807","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.2214\/AJR.09.2360","article-title":"Pulmonary embolism in pregnancy: comparison of pulmonary CT angiography and lung scintigraphy.","volume":"193","author":"Ridge","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"R41-20250807","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/AOG.0b013e3181a99def","article-title":"Diagnosing pulmonary embolism in pregnancy using computed-tomographic angiography or ventilation-perfusion.","volume":"114","author":"Cahill","year":"2009","journal-title":"Obstet Gynecol"},{"key":"R42-20250807","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1111\/imj.15065","article-title":"An audit of ventilation and perfusion SPECT reporting for the diagnosis of pulmonary embolism in a tertiary cardiothoracic centre.","volume":"50","author":"Kannan","year":"2020","journal-title":"Intern Med J"}],"container-title":["Nuclear Medicine Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000001802","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,7]],"date-time":"2025-08-07T20:05:07Z","timestamp":1754597107000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000001802"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,19]]},"references-count":42,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/mnm.0000000000001802","relation":{},"ISSN":["0143-3636"],"issn-type":[{"type":"print","value":"0143-3636"}],"subject":[],"published":{"date-parts":[[2024,1,19]]}}}