{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T10:20:38Z","timestamp":1785320438595,"version":"3.55.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Dopamine transporter single-photon emission computed tomography (DAT-SPECT) plays an important role in diagnosing parkinsonism. Recently, a reference-based quantitative analysis utilizing a Japanese normal database for DAT-SPECT was developed. This study aimed to investigate the frequency and trends of cases wherein the analysis- and physician-based diagnoses diverged.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Two physicians performed an interpretation task twice on 195 DAT-SPECT scans. After assessing intra- and intertester agreements, disagreements were resolved by consensus. For the reference-based quantitative analysis, the calibrated specific binding ratio (cSBR), calibrated asymmetry index (cAI), and Z-scores were measured. Images were grouped according to physician consensus and the negative\u2013positive difference from thresholds (Z-score of less than \u22122.0 and\/or cAI of more than 12.22) as follows: group 1 (physician, normal; quantitative analysis, normal; <jats:italic toggle=\"yes\">n<\/jats:italic>\u2005=\u200570), group 2 (abnormal; normal; <jats:italic toggle=\"yes\">n<\/jats:italic>\u2005=\u20054), group 3 (normal; abnormal; <jats:italic toggle=\"yes\">n<\/jats:italic>\u2005=\u200531), and group 4 (abnormal; abnormal; <jats:italic toggle=\"yes\">n<\/jats:italic>\u2005=\u200590).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Median cSBRs and Z-scores decreased in order from group 1 to group 4. Median cAI values increased in the order of groups 1, 3, 2, and 4. Significant differences were observed between groups 1 and 2 for cSBRs and cAIs; groups 2 and 3 for Z-scores; groups 2 and 4 for cSBRs and Z-scores; and groups 1 and 3, 1 and 4, and 3 and 4 for all parameters (Kruskal\u2013Wallis and Steel\u2013Dwass tests).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>In approximately 18% of cases, the visual interpretation of physicians diverged from the reference-based quantitative analysis based on a Japanese normal database. It is crucial to appropriately utilize DAT-SPECT reference-based quantitative analysis as a diagnostic aid.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mnm.0000000000001968","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T07:02:44Z","timestamp":1740466964000},"page":"523-532","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of visual interpretation of [I-123] FP-CIT SPECT scans versus reference-based quantitative analysis utilizing a Japanese normal database"],"prefix":"10.1097","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0265-5636","authenticated-orcid":false,"given":"Ryo","family":"Yamakuni","sequence":"first","affiliation":[{"name":"Radiology and Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiro","family":"Ishii","sequence":"additional","affiliation":[{"name":"Radiology and Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Fukushima","sequence":"additional","affiliation":[{"name":"Radiology and Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeyasu","family":"Kakamu","sequence":"additional","affiliation":[{"name":"Hygiene and Preventive Medicine, School of Medicine, Fukushima Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masanori","family":"Yusa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Fukushima Medical University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuyuki","family":"Kikori","sequence":"additional","affiliation":[{"name":"Department of Radiology, Fukushima Medical University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tensho","family":"Yamao","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, School of Health Science"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noriyuki","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, School of Health Science"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirofumi","family":"Sekino","sequence":"additional","affiliation":[{"name":"Radiology and Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuntaro","family":"Itagaki","sequence":"additional","affiliation":[{"name":"Department of Neuropsychiatry, School of Medicine, Fukushima Medical University, Fukushima, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Itaru","family":"Miura","sequence":"additional","affiliation":[{"name":"Department of Neuropsychiatry, School of Medicine, Fukushima Medical University, Fukushima, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Ito","sequence":"additional","affiliation":[{"name":"Radiology and Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,25]]},"reference":[{"key":"R1-20250507","doi-asserted-by":"crossref","first-page":"17013","DOI":"10.1038\/nrdp.2017.13","article-title":"Parkinson disease.","volume":"3","author":"Poewe","year":"2017","journal-title":"Nat Rev Dis Primers"},{"key":"R2-20250507","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1016\/j.amjmed.2019.03.001","article-title":"Parkinson\u2019s disease and parkinsonism.","volume":"132","author":"Hayes","year":"2019","journal-title":"Am J Med"},{"key":"R3-20250507","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1002\/1531-8257(200005)15:3<503::AID-MDS1013>3.0.CO;2-V","article-title":"Accurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: the [123I]-FP-CIT study group.","volume":"15","author":"Benamer","year":"2000","journal-title":"Mov Disord"},{"key":"R4-20250507","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1136\/jnnp.2008.157370","article-title":"The role of DAT-SPECT in movement disorders.","volume":"81","author":"K\u00e4gi","year":"2010","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"R5-20250507","doi-asserted-by":"crossref","first-page":"S153","DOI":"10.1259\/bjr\/89285735","article-title":"SPECT imaging in dementia.","volume":"80 Spec No 2","author":"Pimlott","year":"2007","journal-title":"Br J Radiol"},{"key":"R6-20250507","doi-asserted-by":"crossref","first-page":"1306546","DOI":"10.3389\/fneur.2024.1306546","article-title":"Harmonizing multisite data with the ComBat method for enhanced Parkinson\u2019s disease diagnosis via DAT-SPECT.","volume":"15","author":"Wakasugi","year":"2024","journal-title":"Front Neurol"},{"key":"R7-20250507","doi-asserted-by":"crossref","first-page":"1988","DOI":"10.1007\/s00259-023-06154-y","article-title":"The diagnostic performance of functional dopaminergic scintigraphic imaging in the diagnosis of dementia with Lewy bodies: an updated systematic review.","volume":"50","author":"Jreige","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R8-20250507","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1007\/s00259-018-3976-5","article-title":"Japanese multicenter database of healthy controls for [123I]FP-CIT SPECT.","volume":"45","author":"Matsuda","year":"2018","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R9-20250507","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1007\/s00259-022-06069-0","article-title":"Different z-score cut-offs for striatal binding ratio (SBR) of DaT SPECT are needed to support the diagnosis of Parkinson\u2019s disease (PD) and dementia with Lewy bodies (DLB).","volume":"50","author":"Lanfranchi","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R10-20250507","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1002\/1531-8257(200007)15:4<692::AID-MDS1014>3.0.CO;2-V","article-title":"Correlation of Parkinson\u2019s disease severity and duration with 123I-FP-CIT SPECT striatal uptake.","volume":"15","author":"Benamer","year":"2000","journal-title":"Mov Disord"},{"key":"R11-20250507","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00415-011-6163-1","article-title":"Visual assessment of dopaminergic degeneration pattern in 123I-FP-CIT SPECT differentiates patients with atypical parkinsonian syndromes and idiopathic Parkinson\u2019s disease.","volume":"259","author":"Kahraman","year":"2012","journal-title":"J Neurol"},{"key":"R12-20250507","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1007\/s00259-011-1801-5","article-title":"Calibration of gamma camera systems for a multicentre European 123I-FP-CIT SPECT normal database.","volume":"38","author":"Tossici-Bolt","year":"2011","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R13-20250507","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1007\/s00259-012-2304-8","article-title":"Automatic semi-quantification of [123I]FP-CIT SPECT scans in healthy volunteers using BasGan version 2: results from the ENC-DAT database.","volume":"40","author":"Nobili","year":"2013","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R14-20250507","first-page":"95","article-title":"Improvement of diagnostic accuracy of Parkinson\u2019s disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database.","volume":"8","author":"Kanzaki","year":"2020","journal-title":"Asia Ocean J Nucl Med Biol"},{"key":"R15-20250507","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1186\/s12883-021-02470-8","article-title":"Evaluating dopamine transporter imaging as an enrichment biomarker in a phase 2 Parkinson\u2019s disease trial.","volume":"21","author":"Hutchison","year":"2021","journal-title":"BMC Neurol"},{"key":"R16-20250507","doi-asserted-by":"crossref","first-page":"e96","DOI":"10.1097\/RLU.0000000000001477","article-title":"Added value of combined semi-quantitative and visual [123I]FP-CIT SPECT analyses for the diagnosis of dementia with Lewy bodies.","volume":"42","author":"Nicastro","year":"2017","journal-title":"Clin Nucl Med"},{"key":"R17-20250507","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1037\/h0026256","article-title":"Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit.","volume":"70","author":"Cohen","year":"1968","journal-title":"Psychol Bull"},{"key":"R19-20250507","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.1007\/s00702-016-1586-6","article-title":"Visual versus automated analysis of [I-123]FP-CIT SPECT scans in parkinsonism.","volume":"123","author":"M\u00e4kinen","year":"2016","journal-title":"J Neural Transm (Vienna)"},{"key":"R20-20250507","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1007\/s00259-023-06565-x","article-title":"Effects of medication on dopamine transporter imaging using [123I]I-FP-CIT SPECT in routine practice.","volume":"51","author":"Piatkova","year":"2024","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R21-20250507","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1007\/s00259-007-0621-0","article-title":"Dopamine transporter imaging with [123I]FP-CIT SPECT: potential effects of drugs.","volume":"35","author":"Booij","year":"2008","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R22-20250507","doi-asserted-by":"crossref","first-page":"459","DOI":"10.7863\/ultra.16.03025","article-title":"Computing the Z score and centiles for cross-sectional analysis: a practical approach.","volume":"36","author":"DeVore","year":"2017","journal-title":"J Ultrasound Med"},{"key":"R23-20250507","first-page":"1","article-title":"Reduced dopamine transporter availability in drug\u2010naive adult attention\u2010deficit\/hyperactivity disorder.","volume":"3","author":"Itagaki","year":"2024","journal-title":"PCN Rep"},{"key":"R24-20250507","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1038\/s41398-018-0328-y","article-title":"Ventral striatal dopamine transporter availability is associated with lower trait motor impulsivity in healthy adults.","volume":"8","author":"Smith","year":"2018","journal-title":"Transl Psychiatry"},{"key":"R25-20250507","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1136\/jnnp-2011-301695","article-title":"Impact of DaTscan SPECT imaging on clinical management, diagnosis, confidence of diagnosis, quality of life, health resource use and safety in patients with clinically uncertain parkinsonian syndromes: a prospective 1-year follow-up of an open-label controlled study.","volume":"83","author":"Kupsch","year":"2012","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"R26-20250507","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/j.nicl.2018.09.012","article-title":"A new visual rating scale for Ioflupane imaging in Lewy body disease.","volume":"20","author":"Lloyd","year":"2018","journal-title":"Neuroimage Clin"},{"key":"R27-20250507","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1016\/j.ejrad.2016.01.011","article-title":"Assessment of PI-RADS v2 for the detection of prostate cancer.","volume":"85","author":"Kasel-Seibert","year":"2016","journal-title":"Eur J Radiol"},{"key":"R28-20250507","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1148\/radiology.211.3.r99jn31845","article-title":"BI-RADS categorization as a predictor of malignancy.","volume":"211","author":"Orel","year":"1999","journal-title":"Radiology"}],"container-title":["Nuclear Medicine Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000001968","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T09:00:23Z","timestamp":1746608423000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000001968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,25]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/mnm.0000000000001968","relation":{},"ISSN":["0143-3636","1473-5628"],"issn-type":[{"value":"0143-3636","type":"print"},{"value":"1473-5628","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,25]]}}}