{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T10:49:56Z","timestamp":1789728596710,"version":"4.0.1"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Nuclear medicine\u2019s lung perfusion scintigraphy is a valuable imaging technique for assessing many health conditions. Various methods have been described in the literature for segmenting and quantifying the lung perfusion in single-photon emission computed tomography\/computed tomography (SPECT\/CT) images, but they rely on commercially available software, require manual definition of regions\/volumes of interest, or both.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study proposes a never reported approach to segment and quantify SPECT (and SPECT\/CT) lung perfusion images by developing a fully automated algorithm utilizing only free software.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Python programming language was used to write a completely automated algorithm for 3D Slicer to segment and quantify SPECT and SPECT\/CT images. The algorithm was tested in 37 lung perfusion images, collected retrospectively from a public hospital database.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The algorithm was able to perform fully automated lobar perfusion quantification. The mean relative perfusion found were: LUL \u2013 23.5%, LLL \u2013 22.3%, RUL \u2013 24.6%, RML \u2013 7.9%, and RLL \u2013 21.7%. The algorithm also segmented and quantified the relative perfusion of the left (L) and right (R) lungs without the aid of CT: L \u2013 44.6% and R \u2013 55.3%; and found no statistical difference in the results obtained with or without CT (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      -value\u2005=\u20050.38 and 0.44, respectively).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The algorithm created required no user interaction, presented good agreement with previously reported works, and was on average 10 times faster than the fastest algorithm reported on the literature, thus making it a free, efficient, and reliable tool for assisting diagnosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/mnm.0000000000002102","type":"journal-article","created":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T10:00:09Z","timestamp":1768298409000},"page":"380-387","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Fully automated regional lung perfusion quantification in SPECT\/CT images with open-source software"],"prefix":"10.1097","volume":"47","author":[{"given":"Daniel M.","family":"Seraphim","sequence":"first","affiliation":[{"name":"Medical Physics and Radiological Protecion Unit, Botucatu Medical School, Clinics Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o Pedro P.","family":"Borges","sequence":"additional","affiliation":[{"name":"Institute of Biosciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davi B.S.","family":"Pantano","sequence":"additional","affiliation":[{"name":"Institute of Biosciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diana R.","family":"de Pina","sequence":"additional","affiliation":[{"name":"Department of Infectious Diseases, Dermatology, Diagnostic Imaging and Radiotherapy, Botucatu Medical School, S\u00e3o Paulo State University (UNESP), Botucatu, S\u00e3o Paulo, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,1,13]]},"reference":[{"key":"R3-20260304","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1053\/j.semnuclmed.2019.07.004","article-title":"A brief history of lung ventilation and perfusion imaging over the 50-year tenure of the editors of seminars in nuclear medicine.","volume":"50","author":"Bailey","year":"2020","journal-title":"Semin Nucl Med"},{"key":"R4-20260304","doi-asserted-by":"crossref","first-page":"2427","DOI":"10.1007\/s00259-019-04464-8","article-title":"A guide for a brave future for lung ventilation\/perfusion tomography: the most important pulmonary nuclear medicine technique.","volume":"46","author":"Bajc","year":"2019","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R5-20260304","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1007\/s00259-009-1170-5","article-title":"EANM guidelines for ventilation\/perfusion scintigraphy: Part 1. Pulmonary imaging with ventilation\/perfusion single photon emission tomography.","volume":"36","author":"Bajc","year":"2009","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R6-20260304","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1007\/BF01268022","article-title":"Comparison of perfusion lung scanning and angiography in the estimation of vascular obstruction in acute pulmonary embolism.","volume":"17","author":"Meyer","year":"1990","journal-title":"Eur J Nucl Med"},{"key":"R7-20260304","doi-asserted-by":"crossref","first-page":"2429","DOI":"10.1007\/s00259-019-04450-0","article-title":"EANM guideline for ventilation\/perfusion single-photon emission computed tomography (SPECT) for diagnosis of pulmonary embolism and beyond.","volume":"46","author":"Bajc","year":"2019","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R9-20260304","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.trre.2018.10.003","article-title":"Ventilation perfusion pulmonary scintigraphy in the evaluation of pre- and post-lung transplant patients.","volume":"33","author":"Pinho","year":"2019","journal-title":"Transplant Rev (Orlando)"},{"key":"R10-20260304","doi-asserted-by":"crossref","first-page":"57","DOI":"10.2967\/jnmt.111.101386","article-title":"SNM practice guideline for lung scintigraphy 4.0.","volume":"40","author":"Parker","year":"2012","journal-title":"J Nucl Med Technol"},{"key":"R11-20260304","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1097\/MNM.0000000000001247","article-title":"Functional lung volume mapping with perfusion single-photon emission computed tomography scan for radiotherapy planning in patients with locally advanced nonsmall cell lung cancer.","volume":"41","author":"Follacchio","year":"2020","journal-title":"Nucl Med Commun"},{"key":"R12-20260304","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1097\/MNM.0000000000000098","article-title":"Differential regional lung uptake analysis of the lung scan as an adjunct to interpretation of pulmonary embolism.","volume":"35","author":"Ali","year":"2014","journal-title":"Nucl Med Commun"},{"key":"R13-20260304","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1007\/s13139-016-0448-3","article-title":"Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT\/CT.","volume":"51","author":"Suh","year":"2017","journal-title":"Nucl Med Mol Imaging"},{"key":"R14-20260304","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1007\/s13139-019-00617-7","article-title":"Comparative analysis of lung perfusion scan and SPECT\/CT for the evaluation of functional lung capacity.","volume":"53","author":"Suh","year":"2019","journal-title":"Nucl Med Mol Imaging"},{"key":"R15-20260304","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s41824-018-0036-0","article-title":"Is hybrid SPECT\/CT necessary for pre-interventional 3D quantification of relative lobar lung function?","volume":"2","author":"Knollmann","year":"2018","journal-title":"Eur J Hybrid Imaging"},{"key":"R16-20260304","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1159\/000500407","article-title":"Lobar quantification by ventilation\/perfusion SPECT\/CT in patients with severe emphysema undergoing lung volume reduction with endobronchial valves.","volume":"98","author":"Kristiansen","year":"2019","journal-title":"Respiration"},{"key":"R17-20260304","doi-asserted-by":"crossref","first-page":"185","DOI":"10.2967\/jnmt.117.191056","article-title":"Reproducibility of lobar perfusion and ventilation quantification using SPECT\/CT segmentation software in lung cancer patients.","volume":"45","author":"Provost","year":"2017","journal-title":"J Nucl Med Technol"},{"key":"R18-20260304","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1186\/s40658-023-00578-z","article-title":"Clinical validation of an AI-based automatic quantification tool for lung lobes in SPECT\/CT.","volume":"10","author":"Verrecchia-Ramos","year":"2023","journal-title":"EJNMMI Phys"},{"key":"R19-20260304","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.lungcan.2018.02.010","article-title":"Pre-operative quantification of pulmonary function using hybrid-SPECT\/low-dose-CT: a pilot study.","volume":"118","author":"Genseke","year":"2018","journal-title":"Lung Cancer"},{"key":"R20-20260304","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1007\/s12149-023-01848-7","article-title":"Quantitative analysis of lung function and airway remodeling using ventilation\/perfusion single photon emission tomography\/computed tomography and HRCT in patients with chronic obstructive pulmonary disease and asthma.","volume":"37","author":"Xie","year":"2023","journal-title":"Ann Nucl Med"},{"key":"R21-20260304","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s11517-022-02717-7","article-title":"An automatic segmentation framework for computer-assisted renal scintigraphy procedure.","volume":"61","author":"Rahimi","year":"2023","journal-title":"Med Biol Eng Comput"},{"key":"R22-20260304","doi-asserted-by":"crossref","first-page":"e218","DOI":"10.1002\/mp.13764","article-title":"Computer\u2010aided diagnosis in the era of deep learning.","volume":"47","author":"Chan","year":"2020","journal-title":"Med Phys"},{"key":"R23-20260304","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.21037\/tlcr-20-708","article-title":"Radiomics and artificial intelligence in lung cancer screening.","volume":"10","author":"Binczyk","year":"2021","journal-title":"Transl Lung Cancer Res"},{"key":"R24-20260304","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s00259-022-05947-x","article-title":"An EANM position paper on the application of artificial intelligence in nuclear medicine.","volume":"50","author":"Hustinx","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R25-20260304","doi-asserted-by":"crossref","first-page":"2120","DOI":"10.1007\/s00247-021-05146-0","article-title":"Current and emerging artificial intelligence applications in chest imaging: a pediatric perspective.","volume":"52","author":"Schalekamp","year":"2022","journal-title":"Pediatr Radiol"},{"key":"R26-20260304","doi-asserted-by":"crossref","first-page":"81549","DOI":"10.1007\/s11042-024-18761-4","article-title":"CT imaging and lung segmentation analysis of SARS-CoV-2 variants and vaccination impacts on lung impairment quantification.","volume":"83","author":"Silva","year":"2024","journal-title":"Multimed Tools Appl"},{"key":"R27-20260304","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","article-title":"3D Slicer as an image computing platform for the Quantitative Imaging Network.","volume":"30","author":"Fedorov","year":"2012","journal-title":"Magn Reson Imaging"},{"key":"R28-20260304","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/0734-189X(85)90133-1","article-title":"moment-preserving thresholding: a new approach.","volume":"29","author":"Tsai","year":"1985","journal-title":"Comput Vision Gr Image Process"},{"key":"R29-20260304","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1007\/s12149-024-01969-7","article-title":"How anatomical impairments found on CT affect perfusion percentage assessed by SPECT\/CT scan?","volume":"38","author":"Seraphim","year":"2024","journal-title":"Ann Nucl Med"},{"key":"R30-20260304","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1007\/s12149-017-1223-y","article-title":"Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.","volume":"32","author":"Cheimariotis","year":"2018","journal-title":"Ann Nucl Med"},{"key":"R31-20260304","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40658-022-00446-2","article-title":"The magnitude of the partial volume effect in SPECT imaging of the kidneys: a phantom study.","volume":"9","author":"Grings","year":"2022","journal-title":"EJNMMI Phys"},{"key":"R32-20260304","doi-asserted-by":"crossref","first-page":"932","DOI":"10.2967\/jnumed.106.035774","article-title":"Partial-volume effect in PET tumor imaging.","volume":"48","author":"Soret","year":"2007","journal-title":"J Nucl Med"},{"key":"R33-20260304","doi-asserted-by":"crossref","first-page":"54","DOI":"10.4274\/mirt.galenos.2020.05658","article-title":"Small-angle Compton scatter artifact in Tc-99m-IDA hepatobiliary scintigraphy resulting in the breast overlying the liver in planar dynamic imaging.","volume":"30","author":"Qutbi","year":"2021","journal-title":"Mol Imaging Radionucl Ther"}],"container-title":["Nuclear Medicine Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000002102","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T07:00:27Z","timestamp":1772607627000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MNM.0000000000002102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,13]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/mnm.0000000000002102","relation":{},"ISSN":["0143-3636","1473-5628"],"issn-type":[{"value":"0143-3636","type":"print"},{"value":"1473-5628","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,13]]},"assertion":[{"value":"2025-09-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}