{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T20:08:58Z","timestamp":1793304538692,"version":"4.5.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>Continuous glucose monitoring (CGM) is increasingly used in the management of diabetes in children and adults, but there are few data regarding its use in neonates. The purpose of this article is to discuss the potential benefits and limitations of CGM in neonates.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>Smaller electrodes in new sensors and real-time monitoring have made CGM devices more approachable for neonatal care. CGM is well tolerated in infants including very low birth weight babies, and few if any local complications have been reported. Use of CGM in newborns may reduce the frequency of blood sampling and improve glycemic stability, with more time spent in the euglycemic range. However, CGM may also lead to more intervention, with potential adverse effects on outcomes. More information is also needed about reliability, calibration and interpretation of CGM in the neonate.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Although the use of CGM in neonates appears to be well tolerated, feasible and has been associated with better glycemic status, there is not yet any evidence of improved clinical outcomes. Clinical utility of CGM should be demonstrated in randomized trials prior to its introduction into regular neonatal care.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mop.0000000000000592","type":"journal-article","created":{"date-parts":[[2018,1,17]],"date-time":"2018-01-17T20:21:36Z","timestamp":1516220496000},"page":"204-208","source":"Crossref","is-referenced-by-count":34,"title":["Neonatal hypoglycemia: continuous glucose monitoring"],"prefix":"10.1097","volume":"30","author":[{"given":"Rajesh","family":"Shah","sequence":"first","affiliation":[{"name":"Liggins Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.D.","family":"McKinlay","sequence":"additional","affiliation":[{"name":"Liggins Institute"},{"name":"Department of Paediatrics, Child and Youth Health, University of Auckland, Auckland"},{"name":"Kidz First Neonatal Care, Counties Manukau Health, Pukekohe, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jane E.","family":"Harding","sequence":"additional","affiliation":[{"name":"Liggins Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"(Suppl 1)","key":"R1-20230918","doi-asserted-by":"crossref","first-page":"S17","DOI":"10.1089\/dia.2008.0133","article-title":"The chemistry of commercial continuous glucose monitors","volume":"11","author":"McGarraugh","year":"2009","journal-title":"Diabetes Technol Ther"},{"key":"R2-20230918","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40748-017-0055-z","article-title":"Continuous glucose monitoring in neonates: a review","volume":"3","author":"McKinlay","year":"2017","journal-title":"Matern Health Neonatol Perinatol"},{"key":"R3-20230918","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.3109\/14767058.2013.858686","article-title":"Experience with real time continuous glucose monitoring in stabilising fluctuating glycaemia during intensive care of the preterm infant of a diabetic mother","volume":"27","author":"Stechova","year":"2014","journal-title":"J Matern Fetal Neonatal Med"},{"key":"R4-20230918","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/s13052-016-0236-9","article-title":"Continuous glucose monitoring in preterm infants: evaluation by a modified Clarke error grid","volume":"42","author":"Tiberi","year":"2016","journal-title":"Ital J Pediatr"},{"key":"R5-20230918","doi-asserted-by":"crossref","first-page":"e0116255","DOI":"10.1371\/journal.pone.0116255","article-title":"Real-time continuous glucose monitoring reduces the duration of hypoglycemia episodes: a randomized trial in very low birth weight neonates","volume":"10","author":"Uettwiller","year":"2015","journal-title":"PLoS One"},{"key":"R6-20230918","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1111\/apa.13479","article-title":"Continuous subcutaneous glucose monitoring is accurate in term and near-term infants at risk of hypoglycaemia","volume":"105","author":"Wackernagel","year":"2016","journal-title":"Acta Paediatr"},{"key":"R7-20230918","doi-asserted-by":"crossref","first-page":"e20171162","DOI":"10.1542\/peds.2017-1162","article-title":"Continuous glucose monitoring in very preterm infants: a randomized controlled trial","volume":"140","author":"Galderisi","year":"2017","journal-title":"Pediatrics"},{"key":"R8-20230918","doi-asserted-by":"crossref","first-page":"F136","DOI":"10.1136\/archdischild-2012-301661","article-title":"Validation of the continuous glucose monitoring sensor in preterm infants","volume":"98","author":"Beardsall","year":"2012","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"R9-20230918","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1089\/dia.2012.0111","article-title":"Impact of retrospective calibration algorithms on hypoglycemia detection in newborn infants using continuous glucose monitoring","volume":"14","author":"Signal","year":"2012","journal-title":"Diabetes Technol Ther"},{"key":"R10-20230918","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.jpeds.2010.02.003","article-title":"Continuous glucose monitoring in newborn babies at risk of hypoglycemia","volume":"157","author":"Harris","year":"2010","journal-title":"J Pediatr"},{"key":"R11-20230918","doi-asserted-by":"crossref","first-page":"e76702","DOI":"10.1371\/journal.pone.0076702","article-title":"Neonatal pain-related stress predicts cortical thickness at age 7 years in children born very preterm","volume":"8","author":"Ranger","year":"2013","journal-title":"PLoS One"},{"key":"R12-20230918","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1056\/NEJMoa1504909","article-title":"Neonatal glycemia and neurodevelopmental outcomes at 2 years","volume":"373","author":"McKinlay","year":"2015","journal-title":"N Engl J Med"},{"key":"R13-20230918","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.jpeds.2010.04.032","article-title":"Prevalence and determinants of hyperglycemia in very low birth weight infants: cohort analyses of the NIRTURE study","volume":"157","author":"Beardsall","year":"2010","journal-title":"J Pediatr"},{"key":"R14-20230918","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/j.jpeds.2005.06.039","article-title":"Association between fluid intake and weight loss during the first ten days of life and risk of bronchopulmonary dysplasia in extremely low birth weight infants","volume":"147","author":"Oh","year":"2005","journal-title":"J Pediatr"},{"key":"R15-20230918","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1001\/jamapediatrics.2017.1579","article-title":"Association of neonatal glycemia with neurodevelopmental outcomes at 4.5 years","volume":"171","author":"McKinlay","year":"2017","journal-title":"JAMA Pediatrics"},{"key":"R16-20230918","doi-asserted-by":"crossref","first-page":"F126","DOI":"10.1136\/archdischild-2014-306168","article-title":"Clinically stable very low birthweight infants are at risk for recurrent tissue glucose fluctuations even after fully established enteral nutrition","volume":"100","author":"Mola-Schenzle","year":"2014","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"R17-20230918","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1016\/j.jpeds.2014.08.029","article-title":"Instability of glucose values in very preterm babies at term postmenstrual age","volume":"165","author":"Pertierra-Cortada","year":"2014","journal-title":"J Pediatr"},{"key":"R18-20230918","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1159\/000166847","article-title":"Cot-side electro-encephalography and interstitial glucose monitoring during insulin-induced hypoglycaemia in newborn lambs","volume":"95","author":"Harris","year":"2009","journal-title":"Neonatology"},{"key":"R19-20230918","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1177\/1932296814533091","article-title":"Continuous glucose monitoring and trend accuracy: news about a trend compass","volume":"8","author":"Signal","year":"2014","journal-title":"J Diabetes Sci Technol"}],"container-title":["Current Opinion in Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00008480-201804000-00008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T02:13:20Z","timestamp":1695003200000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00008480-201804000-00008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/mop.0000000000000592","relation":{},"ISSN":["1040-8703","1531-698X"],"issn-type":[{"value":"1040-8703","type":"print"},{"value":"1531-698X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4]]}}}