{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T06:25:38Z","timestamp":1790749538775,"version":"4.1.0"},"reference-count":81,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>There is expanding evidence for point-of-care ultrasound (POCUS) use in pediatric emergency medicine \u2013 this review highlights the benefits and challenges in the clinical integration of high-yield POCUS applications. Specifically, it will delve into POCUS applications during resuscitations, controversies of Focused Assessment with Sonography for Trauma (FAST) in pediatric trauma, POCUS-guided procedures, and examples of clinical pathways where POCUS can expedite definitive care.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>POCUS can enhance diagnostic accuracy and aid in management of pediatric patients in shock and help identify reversible causes during cardiac arrest. The use of the FAST in pediatric blunt abdominal trauma remains nuanced \u2013 its proper use requires an integration with clinical findings and an appreciation of its limitations. POCUS has been shown to enhance safety and efficacy of procedures such as nerve blocks, incision &amp; drainage, and intravenous access. Integrating POCUS into pathways for conditions such as intussusception and testicular torsion expedites downstream care.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>POCUS enhances diagnostic efficiency and management in pediatric patients arriving at the ED with undifferentiated shock, cardiac arrest, or trauma. Additionally, POCUS improves procedural success and safety, and is integral to clinical pathways for expediting definitive care for various pediatric emergencies. Future research should continue to focus on the impact of POCUS on patient outcomes, ensuring user competency, and the expansion of POCUS into diverse settings.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mop.0000000000001340","type":"journal-article","created":{"date-parts":[[2024,2,27]],"date-time":"2024-02-27T11:02:39Z","timestamp":1709031759000},"page":"256-265","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":19,"title":["Updates on the clinical integration of point-of-care ultrasound in pediatric emergency medicine"],"prefix":"10.1097","volume":"36","author":[{"given":"Michelle Sin","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danielle","family":"Sweetnam-Holmes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gili Palnizky","family":"Soffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maya","family":"Harel-Sterling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,2,23]]},"reference":[{"key":"R1-20250730","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/MOP.0000000000001244","article-title":"Updates in pediatric ultrasound","volume":"35","author":"Ruscica","year":"2023","journal-title":"Curr Opin Pediatr"},{"key":"R2-20250730","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/MOP.0000000000000097","article-title":"Advances in point-of-care ultrasound in pediatric emergency medicine","volume":"26","author":"Gallagher","year":"2014","journal-title":"Curr Opin Pediatr"},{"key":"R3-20250730","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1186\/s13054-023-04495-6","article-title":"Diagnostic accuracy of point-of-care ultrasound for shock: a systematic review and meta-analysis","volume":"27","author":"Yoshida","year":"2023","journal-title":"Crit Care"},{"key":"R4-20250730","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.3390\/jcm12031105","article-title":"Point of care ultrasonography for the septic patient in the emergency department: a literature review","volume":"12","author":"Verras","year":"2023","journal-title":"J Clin Med"},{"key":"R5-20250730","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1017\/cem.2018.498","article-title":"The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: a systematic review and meta-analysis","volume":"21","author":"Stickles","year":"2019","journal-title":"CJEM"},{"key":"R6-20250730","doi-asserted-by":"crossref","first-page":"e1198","DOI":"10.1097\/PEC.0000000000002546","article-title":"Focused cardiac ultrasound findings in children presenting with shock to a tertiary care hospital in Rwanda","volume":"38","author":"Chen","year":"2022","journal-title":"Pediatr Emerg Care"},{"key":"R7-20250730","first-page":"186","article-title":"Point-of-care ultrasound in early diagnosis of cardiomyopathy in a child with viral myocarditis: a case report","volume":"5","author":"Gupta","year":"2021","journal-title":"Clin Pract Cases Emerg Med"},{"key":"R8-20250730","doi-asserted-by":"crossref","first-page":"e18","DOI":"10.1016\/j.jemermed.2021.03.015","article-title":"Diagnosing acute heart failure in the pediatric emergency department using point-of-care ultrasound","volume":"61","author":"Hamad","year":"2021","journal-title":"J Emerg Med"},{"key":"R9-20250730","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s43678-023-00611-1","article-title":"POCUS literature primer: key papers on POCUS in cardiac arrest and shock","volume":"26","author":"Kim","year":"2023","journal-title":"CJEM"},{"key":"R10-20250730","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1055\/a-2048-6274","article-title":"The effect of point-of-care ultrasound on length of stay and mortality in patients with chest pain\/dyspnea","volume":"44","author":"Huang","year":"2023","journal-title":"Ultraschall Med"},{"key":"R11-20250730","first-page":"e0019","article-title":"Impact of point-of-care ultrasound in the emergency department on care processes and outcomes in critically ill nontraumatic patients","volume":"1","author":"Mosier","year":"2019","journal-title":"Crit Care Explor"},{"key":"R12-20250730","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1007\/s43678-022-00431-9","article-title":"Does point-of-care ultrasonography improve diagnostic accuracy in emergency department patients with undifferentiated hypotension? An international randomized controlled trial from the SHOC-ED investigators","volume":"25","author":"Peach","year":"2023","journal-title":"CJEM"},{"key":"R13-20250730","first-page":"46","article-title":"A study to compare ultrasound-guided and clinically guided fluid management in children with septic shock","volume":"27","author":"Kaiser","year":"2023","journal-title":"Indian J Crit Care Med"},{"key":"R14-20250730","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jped.2017.02.005","article-title":"Role of echocardiography in reducing shock reversal time in pediatric septic shock: a randomized controlled trial","volume":"94","author":"El-Nawawy","year":"2018","journal-title":"J Pediatr"},{"key":"R15-20250730","first-page":"e0231","article-title":"Myocardial dysfunction is independently associated with mortality in pediatric septic shock","volume":"2","author":"Lautz","year":"2020","journal-title":"Crit Care Explor"},{"key":"R16-20250730","doi-asserted-by":"crossref","first-page":"548","DOI":"10.12998\/wjcc.v7.i5.548","article-title":"Clinical presentation and early predictors for poor outcomes in pediatric myocarditis: a retrospective study","volume":"7","author":"Rodriguez-Gonzalez","year":"2019","journal-title":"World J Clin Cases"},{"key":"R17-20250730","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.echo.2022.11.010","article-title":"Recommendations for cardiac point-of-care ultrasound in children: a report from the american society of echocardiography","volume":"36","author":"Lu","year":"2023","journal-title":"J Am Soc Echocardiogr"},{"key":"R18-20250730","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.jemermed.2021.09.009","article-title":"Left ventricular ejection fraction assessment by emergency physician-performed bedside echocardiography: a prospective comparative evaluation of multiple modalities","volume":"61","author":"Bahl","year":"2021","journal-title":"J Emerg Med"},{"key":"R19-20250730","doi-asserted-by":"crossref","first-page":"e486","DOI":"10.1097\/PCC.0000000000001661","article-title":"Mitral annular plane systolic excursion as a predictor of mortality in children with septic shock","volume":"19","author":"El-Zayat","year":"2018","journal-title":"Pediatr Crit Care Med"},{"key":"R20-20250730","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1007\/s42399-021-00804-8","article-title":"Moving toward noninvasive hemodynamic and echocardiographic monitoring in critical pediatric patients in the emergency department: setting standards","volume":"3","author":"Fuenmayor-Oramas","year":"2021","journal-title":"SN Compr Clin Med"},{"key":"R22-20250730","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1007\/s12098-023-04772-w","article-title":"Predicting fluid responsiveness in children with shock: POCUS can guide","volume":"90","author":"Charaya","year":"2023","journal-title":"Indian J Pediatr"},{"key":"R23-20250730","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1177\/0885066617752308","article-title":"Accuracy of ultrasonographic measurements of inferior vena cava to determine fluid responsiveness: a systematic review and meta-analysis","volume":"35","author":"Orso","year":"2020","journal-title":"J Intensive Care Med"},{"key":"R24-20250730","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1111\/1742-6723.12948","article-title":"Does respiratory variation of inferior vena cava diameter predict fluid responsiveness in spontaneously ventilating children with sepsis","volume":"30","author":"Long","year":"2018","journal-title":"Emerg Med Australasia"},{"key":"R25-20250730","doi-asserted-by":"crossref","first-page":"e20095","DOI":"10.5812\/traumamon.20095","article-title":"Accuracy of rapid ultrasound in shock (RUSH) exam for diagnosis of shock in critically ill patients","volume":"20","author":"Ghane","year":"2015","journal-title":"Trauma Mon"},{"key":"R26-20250730","doi-asserted-by":"crossref","first-page":"271","DOI":"10.29252\/beat-060402","article-title":"Diagnostic accuracy of rapid ultrasound in shock (rush) exam; a systematic review and meta-analysis","volume":"6","author":"Keikha","year":"2018","journal-title":"Bull Emerg Trauma"},{"key":"R27-20250730","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.3390\/medicina59061180","article-title":"Point-of-care ultrasound: a multimodal tool for the management of sepsis in the emergency department","volume":"59","author":"Polyzogopoulou","year":"2023","journal-title":"Medicina (Kaunas)"},{"key":"R28-20250730","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1186\/s13054-020-2787-9","article-title":"International evidence-based guidelines on point of care ultrasound (POCUS) for critically ill neonates and children issued by the POCUS Working Group of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC)","volume":"24","author":"Singh","year":"2020","journal-title":"Crit Care"},{"key":"R29-20250730","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1136\/archdischild-2019-317972","article-title":"Fifteen-minute consultation: point of care ultrasound in the management of paediatric shock","volume":"106","author":"Hardwick","year":"2021","journal-title":"Arch Dis Child Educ Pract Ed"},{"key":"R30-20250730","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13089-021-00248-0","article-title":"Point-of-care ultrasound in cardiorespiratory arrest (POCUS-CA): narrative review article","volume":"13","author":"\u00c1vila-Reyes","year":"2021","journal-title":"Ultrasound J"},{"key":"R31-20250730","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.annemergmed.2017.07.476","article-title":"Variability in interpretation of cardiac standstill among physician sonographers","volume":"71","author":"Hu","year":"2018","journal-title":"Ann Emerg Med"},{"key":"R32-20250730","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.annemergmed.2023.04.003","article-title":"Interpretation of cardiac standstill in children using point-of-care ultrasound","volume":"82","author":"Yanni","year":"2023","journal-title":"Ann Emerg Med"},{"key":"R33-20250730","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1097\/PEC.0000000000002741","article-title":"The feasibility of using point-of-care ultrasound during cardiac arrest in children: rapid apical contractility evaluation","volume":"39","author":"Leviter","year":"2023","journal-title":"Pediatr Emerg Care"},{"key":"R34-20250730","doi-asserted-by":"crossref","first-page":"e12650","DOI":"10.1002\/emp2.12650","article-title":"Focused assessment with sonography for trauma in predicting early surgical intervention in hemodynamically unstable children with blunt abdominal trauma","volume":"3","author":"Long","year":"2022","journal-title":"J Am Coll Emerg Physicians Open"},{"key":"R35-20250730","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.resuscitation.2019.03.009","article-title":"The POCUS pulse check: a randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound","volume":"139","author":"Badra","year":"2019","journal-title":"Resuscitation"},{"key":"R36-20250730","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1097\/PEC.0000000000002743","article-title":"Point-of-care ultrasound for pulse checks in pediatric cardiac arrest: two illustrative cases","volume":"39","author":"Leviter","year":"2023","journal-title":"Pediatr Emerg Care"},{"key":"R37-20250730","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jemermed.2020.04.040","article-title":"Endotracheal tube placement confirmation by ultrasonography: a systematic review and meta-analysis of more than 2500 patients","volume":"59","author":"Sahu","year":"2020","journal-title":"J Emerg Med"},{"key":"R39-20250730","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.resuscitation.2017.11.056","article-title":"Point-of-care ultrasound use in patients with cardiac arrest is associated prolonged cardiopulmonary resuscitation pauses: a prospective cohort study","volume":"122","author":"Clattenburg","year":"2018","journal-title":"Resuscitation"},{"key":"R40-20250730","doi-asserted-by":"crossref","first-page":"e01278","DOI":"10.1213\/XAA.0000000000001278","article-title":"Focused cardiac ultrasound and the periresuscitative period: a case series of resident-performed echocardiographic assessment using subcostal-only view in advanced life support","volume":"14","author":"Bughrara","year":"2020","journal-title":"A A Pract"},{"key":"R41-20250730","doi-asserted-by":"crossref","first-page":"e483","DOI":"10.1161\/CIR.0000000000001095","article-title":"2022 International consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations: summary from the basic life support; advanced life support; pediatric life support; neonatal life support; education, implementation, and teams; and first aid task forces","volume":"146","author":"Wyckoff","year":"2022","journal-title":"Circulation"},{"key":"R42-20250730","first-page":"CD012669","article-title":"Point-of-care ultrasonography for diagnosing thoracoabdominal injuries in patients with blunt trauma","volume":"12","author":"Stengel","year":"2018","journal-title":"Cochrane Database Syst Rev"},{"key":"R43-20250730","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/PEC.0000000000001755","article-title":"The utility of the focused assessment with sonography in trauma examination in pediatric blunt abdominal trauma: a systematic review and meta-analysis","volume":"37","author":"Liang","year":"2021","journal-title":"Pediatr Emerg Care"},{"key":"R44-20250730","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1016\/j.jpedsurg.2007.04.023","article-title":"Performance of abdominal ultrasonography in pediatric blunt trauma patients: a meta-analysis","volume":"42","author":"Holmes","year":"2007","journal-title":"J Pediatr Surg"},{"key":"R45-20250730","doi-asserted-by":"crossref","first-page":"e222922","DOI":"10.1001\/jamanetworkopen.2022.2922","article-title":"Development of a consensus-based definition of focused assessment with sonography for trauma in children","volume":"5","author":"Kornblith","year":"2022","journal-title":"JAMA Network Open"},{"key":"R46-20250730","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1111\/acem.13959","article-title":"The utility of focused assessment with sonography for trauma enhanced physical examination in children with blunt torso trauma","volume":"27","author":"Kornblith","year":"2020","journal-title":"Acad Emerg Med"},{"key":"R47-20250730","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1016\/j.jemermed.2016.01.003","article-title":"Pelvic free fluid in asymptomatic pediatric blunt abdominal trauma patients: a case series and review of the literature","volume":"50","author":"Berona","year":"2016","journal-title":"J Emerg Med"},{"key":"R48-20250730","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1002\/jum.15787","article-title":"Ultrasonographic evaluation of physiologic free intraperitoneal fluid in healthy children: a prospective observational study","volume":"41","author":"Arredondo","year":"2022","journal-title":"J Ultrasound Med"},{"key":"R49-20250730","doi-asserted-by":"crossref","first-page":"e1012","DOI":"10.1097\/PEC.0000000000001877","article-title":"Reevaluation of FAST sensitivity in pediatric blunt abdominal trauma patients: should we redefine the qualitative threshold for significant hemoperitoneum?","volume":"37","author":"Riera","year":"2021","journal-title":"Pediatr Emerg Care"},{"key":"R50-20250730","doi-asserted-by":"crossref","first-page":"2290","DOI":"10.1001\/jama.2017.6322","article-title":"Effect of abdominal ultrasound on clinical care, outcomes, and resource use among children with blunt torso trauma: a randomized clinical trial","volume":"317","author":"Holmes","year":"2017","journal-title":"JAMA"},{"key":"R51-20250730","doi-asserted-by":"crossref","first-page":"1","DOI":"10.21037\/jtd.2017.12.37","article-title":"Not so FAST\u2014let's not abandon the pediatric focused assessment with sonography in trauma yet","volume":"10","author":"Moore","year":"2018","journal-title":"J Thorac Dis"},{"key":"R52-20250730","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1111\/j.1553-2712.2011.01242.x","article-title":"The technical errors of physicians learning to perform focused assessment with sonography in trauma","volume":"19","author":"Jang","year":"2012","journal-title":"Acad Emerg Med"},{"key":"R53-20250730","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1007\/s00247-022-05464-x","article-title":"Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen","volume":"53","author":"Davis","year":"2023","journal-title":"Pediatr Radiol"},{"key":"R54-20250730","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/s40477-019-00423-z","article-title":"Contrast-enhanced ultrasonography (CEUS) in the follow-up of pediatric abdominal injuries: value and timing","volume":"23","author":"Di Renzo","year":"2020","journal-title":"J Ultrasound"},{"key":"R55-20250730","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.1007\/s00247-020-04869-w","article-title":"Contrast-enhanced ultrasound of blunt abdominal trauma in children","volume":"51","author":"Paltiel","year":"2021","journal-title":"Pediatr Radiol"},{"key":"R56-20250730","doi-asserted-by":"crossref","first-page":"e12623","DOI":"10.1002\/emp2.12623","article-title":"External validation of a pediatric decision rule for blunt abdominal trauma","volume":"3","author":"Sigal","year":"2022","journal-title":"JACEP Open"},{"key":"R57-20250730","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.emc.2021.04.006","article-title":"Procedural applications of point-of-care ultrasound in pediatric emergency medicine","volume":"39","author":"Shaahinfar","year":"2021","journal-title":"Emerg Med Clin North Am"},{"key":"R58-20250730","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1002\/ca.23406","article-title":"Pediatric regional anesthesia: a review of the relevance of surface anatomy and landmarks used for peripheral nerve blockades in infants and children","volume":"32","author":"Byun","year":"2019","journal-title":"Clin Anat"},{"key":"R59-20250730","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1097\/PEC.0000000000002607","article-title":"Ultrasound-guided regional anesthesia of the femoral nerve in the pediatric emergency department","volume":"39","author":"Heffler.F MA","year":"2023","journal-title":"Pediatr Emerg Care"},{"key":"R60-20250730","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1097\/PEC.0000000000002768","article-title":"Ultrasound-guided paravenous saphenous nerve block for lower extremity abscess incision and drainage in a male adolescent","volume":"39","author":"Allen","year":"2023","journal-title":"Pediatr Emer Care"},{"key":"R61-20250730","doi-asserted-by":"crossref","first-page":"e324","DOI":"10.1097\/PEC.0000000000002190","article-title":"Sedoanalgesia versus infraclavicular block for closed reduction of pediatric forearm fracture in emergency department: prospective randomized study","volume":"37","author":"Karagoz","year":"2021","journal-title":"Pediatr Emer Care"},{"key":"R62-20250730","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1097\/PEC.0000000000001897","article-title":"Ultrasound-guided posterior tibial nerve block for plantar foot foreign body removal","volume":"36","author":"Moake","year":"2020","journal-title":"Pediatr Emerg Care"},{"key":"R63-20250730","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/PEC.0000000000002663","article-title":"Point-of-care ultrasound\u2013guided serratus anterior plane block for chest tube placement in a spontaneous pneumothorax","volume":"38","author":"Khalil","year":"2022","journal-title":"Pediatr Emerg Care"},{"key":"R64-20250730","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.annemergmed.2019.02.019","article-title":"Ultrasonographic guidance to improve first-attempt success in children with predicted difficult intravenous access in the emergency department: a randomized controlled Trial","volume":"74","author":"Vinograd","year":"2019","journal-title":"Ann Emerg Med"},{"key":"R65-20250730","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1177\/1129729820987958","article-title":"Ultrasound guided peripheral IV placement: an observational study of the learning curve in pediatric patients","volume":"23","author":"Anderson","year":"2022","journal-title":"J Vasc Access"},{"key":"R66-20250730","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1016\/j.jen.2023.05.007","article-title":"Outcomes of a comprehensive ultrasound guided peripheral IV insertion (USGPIV) training program in a pediatric emergency department","volume":"49","author":"Jamal","year":"2023","journal-title":"J Emerg Nurs"},{"key":"R67-20250730","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1542\/hpeds.2021-005870","article-title":"Reducing delays in a pediatric procedural unit with ultrasound-guided intravenous line insertion","volume":"11","author":"Peters","year":"2021","journal-title":"Hosp Pediatr"},{"key":"R68-20250730","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.jemermed.2018.07.010","article-title":"Comparison of ultrasound guidance vs. clinical assessment alone for management of pediatric skin and soft tissue infections","volume":"55","author":"Lam","year":"2018","journal-title":"J Emerg Med"},{"key":"R69-20250730","first-page":"e49","article-title":"Point-of-care ultrasonography for identification of skin and soft tissue abscess in adult and pediatric patients; a systematic review and meta-analysis","volume":"11","author":"Rahmani","year":"2023","journal-title":"Arch Acad Emerg Med"},{"key":"R70-20250730","first-page":"339","article-title":"Role of point-of-care ultrasound (POCUS) in the diagnosis of an abscess in paediatric skin and soft tissue infections: a systematic review and meta-analysis","volume":"24","author":"Wu","year":"2022","journal-title":"Med Ultrason"},{"key":"R71-20250730","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1097\/PEC.0000000000002869","article-title":"Validation of a clinical decision rule for ultrasound identification of MRSA skin abscesses in children","volume":"39","author":"Gutierrez","year":"2023","journal-title":"Pediatr Emer Care"},{"key":"R72-20250730","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/s13089-022-00292-4","article-title":"Effect of a point-of-care ultrasound (POCUS) curriculum on emergency department soft tissue management","volume":"14","author":"Nti","year":"2022","journal-title":"Ultrasound J"},{"key":"R73-20250730","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1136\/emermed-2021-212281","article-title":"Diagnostic accuracy of point-of-care ultrasound for paediatric testicular torsion: a systematic review and meta-analysis","volume":"40","author":"Mori","year":"2023","journal-title":"Emerg Med J"},{"key":"R74-20250730","doi-asserted-by":"crossref","first-page":"1760","DOI":"10.1016\/j.ajem.2019.06.006","article-title":"Accuracy of point-of-care ultrasound and radiology-performed ultrasound for intussusception: a systematic review and meta-analysis","volume":"37","author":"Tsou","year":"2019","journal-title":"Am J Emerg Med"},{"key":"R75-20250730","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1016\/j.annemergmed.2021.04.033","article-title":"Diagnostic accuracy of point-of-care ultrasound for intussusception: a multicenter, noninferiority study of paired diagnostic tests","volume":"78","author":"Bergmann","year":"2021","journal-title":"Ann Emerg Med"},{"key":"R76-20250730","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1542\/peds.2014-2833","article-title":"Lung ultrasound for the diagnosis of pneumonia in children: a meta-analysis","volume":"135","author":"Pereda","year":"2015","journal-title":"Pediatrics"},{"key":"R77-20250730","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/s40477-018-0306-5","article-title":"Lung ultrasound in diagnosing pneumonia in childhood: a systematic review and meta-analysis","volume":"21","author":"Orso","year":"2018","journal-title":"J Ultrasound"},{"key":"R78-20250730","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1097\/PEC.0000000000001287","article-title":"A systematic review of testicle survival time after a torsion event","volume":"35","author":"Mellick","year":"2019","journal-title":"Pediatr Emer Care"},{"key":"R79-20250730","doi-asserted-by":"crossref","first-page":"2757","DOI":"10.1002\/jum.16312","article-title":"Implementing point-of-care ultrasound for acute scrotal pain in the pediatric emergency department: screening testicular torsion and patient flow analysis","volume":"42","author":"Park","year":"2023","journal-title":"J Ultrasound Med"},{"key":"R80-20250730","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1097\/PEC.0000000000002863","article-title":"Point-of-care ultrasound for the diagnosis of pediatric testicular torsion: a retrospective case series analysis","volume":"39","author":"Koppel","year":"2023","journal-title":"Pediatr Emerg Care"},{"key":"R81-20250730","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/s002689900158","article-title":"Intussusception in children: international perspective","volume":"20","author":"Meier","year":"1996","journal-title":"World J Surg"},{"key":"R82-20250730","doi-asserted-by":"crossref","first-page":"e27971","DOI":"10.1097\/MD.0000000000027971","article-title":"Effectiveness of the implementation of pediatric intussusception clinical pathway","volume":"100","author":"Paek","year":"2021","journal-title":"Medicine (Baltimore)"},{"key":"R83-20250730","doi-asserted-by":"crossref","first-page":"e90","DOI":"10.1097\/PEC.0000000000001283","article-title":"Point-of-care ultrasound could streamline the emergency department workflow of clinically nonspecific intussusception","volume":"36","author":"Kim","year":"2020","journal-title":"Pediatr Emer Care"}],"container-title":["Current Opinion in Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MOP.0000000000001340","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T18:03:31Z","timestamp":1753898611000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MOP.0000000000001340"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,23]]},"references-count":81,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/mop.0000000000001340","relation":{},"ISSN":["1040-8703","1531-698X"],"issn-type":[{"value":"1040-8703","type":"print"},{"value":"1531-698X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,23]]}}}