{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T16:43:07Z","timestamp":1791304987608,"version":"4.3.1"},"reference-count":98,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>This review outlines the prevalence and complications of apneas and intermittent hypoxemic events in preterm infants, examines current monitoring limitations in neonatal ICUs (NICUs), and explores emerging technologies addressing these challenges.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>New evidence from the Prematurity-Related Ventilatory Control (Pre-Vent) study, which analyzed cardiorespiratory data from 717 extremely preterm infants, exposes the varying frequency, duration, and severity of apneas, intermittent hypoxemia, bradycardias, and periodic breathing during hospitalization, and highlights the negative impact of intermittent hypoxemia on pulmonary outcomes at discharge. Although traditional monitoring methods cannot differentiate between apnea types and quantify their burden, recent advancements in sensor technologies and data integration hold promise for improving real-time detection and evaluation of apneas in the NICU. Notably, small wearable mechano-acoustic sensors could improve apnea monitoring through continuous detection of airflow and respiratory efforts. Additionally, integrating bedside physiological data with modalities such as near-infrared spectroscopy, diaphragmatic activity, and electrical impedance tomography could help predict adverse outcomes by monitoring regional oxygen saturation and lung function in relation to apneas.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Enhancing our understanding of neonatal apneas and overcoming the current limitations in apnea monitoring through advanced sensor technologies and data integration could lead to more personalized management and improved outcomes for preterm infants.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mop.0000000000001432","type":"journal-article","created":{"date-parts":[[2025,1,20]],"date-time":"2025-01-20T14:00:33Z","timestamp":1737381633000},"page":"173-181","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Reimagining apnea monitoring in the neonatal ICU"],"prefix":"10.1097","volume":"37","author":[{"given":"Emily","family":"Jeanne","sequence":"first","affiliation":[{"name":"Department of Medicine, Division of Experimental Medicine, McGill University, Montreal, Quebec"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruben","family":"Alvaro","sequence":"additional","affiliation":[{"name":"Department of Pediatrics and Child Health, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wissam","family":"Shalish","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Montreal Children's Hospital, McGill University Health Center, Montreal, Quebec, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,12,11]]},"reference":[{"key":"R1-20250604","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1038\/pr.2016.43","article-title":"Clinical associations of immature breathing in preterm infants: part 1-central apnea","volume":"80","author":"Fairchild","year":"2016","journal-title":"Pediatr Res"},{"key":"R2-20250604","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1038\/jp.2015.165","article-title":"Cardiorespiratory events in preterm infants: interventions and consequences","volume":"36","author":"Di Fiore","year":"2016","journal-title":"J Perinatol"},{"key":"R3-20250604","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1038\/jp.2015.164","article-title":"Cardiorespiratory events in preterm infants: etiology and monitoring technologies","volume":"36","author":"Di Fiore","year":"2016","journal-title":"J Perinatol"},{"key":"R4-20250604","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1038\/jp.2010.126","article-title":"Apnea of prematurity: pathogenesis and management strategies","volume":"31","author":"Mathew","year":"2011","journal-title":"J Perinatol"},{"key":"R5-20250604","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1164\/rccm.201108-1455CI","article-title":"Obstructive sleep apnea in infants","volume":"185","author":"Katz","year":"2012","journal-title":"Am J Respir Crit Care Med"},{"issue":"(Suppl A)","key":"R6-20250604","doi-asserted-by":"crossref","first-page":"S377","DOI":"10.1016\/S1526-0542(04)90067-X","article-title":"Apnoea of prematurity","volume":"5","author":"Martin","year":"2004","journal-title":"Paediatr Respir Rev"},{"key":"R7-20250604","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/S0022-3476(87)80457-2","article-title":"Comparison of respiratory inductive plethysmography and thoracic impedance for apnea monitoring","volume":"111","author":"Brouillette","year":"1987","journal-title":"J Pediatr"},{"key":"R8-20250604","doi-asserted-by":"crossref","first-page":"2550","DOI":"10.1111\/apa.15888","article-title":"Limitations of thoracic impedance monitoring for central apnoea detection in preterm infants","volume":"110","author":"Lim","year":"2021","journal-title":"Acta Paediatr"},{"key":"R9-20250604","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1164\/ajrccm.154.5.8912777","article-title":"Use of a magnified cardiac airflow oscillation to classify neonatal apnea","volume":"154","author":"Lemke","year":"1996","journal-title":"Am J Respir Crit Care Med"},{"key":"R10-20250604","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1002\/ppul.20989","article-title":"The effects of airway closure in central apneas and obstructed respiratory efforts in mixed apneas in preterm infants","volume":"44","author":"Al-Sufayan","year":"2009","journal-title":"Pediatr Pulmonol"},{"key":"R11-20250604","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1001\/jama.2021.23580","article-title":"Mortality, in-hospital morbidity, care practices, and 2-year outcomes for extremely preterm infants in the US, 2013-2018","volume":"327","author":"Bell","year":"2022","journal-title":"JAMA"},{"key":"R12-20250604","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1001\/jamapediatrics.2021.1921","article-title":"Changes in use of respiratory support for preterm infants in the US, 2008-2018","volume":"175","author":"Hatch","year":"2021","journal-title":"JAMA Pediatr"},{"key":"R13-20250604","doi-asserted-by":"crossref","DOI":"10.1542\/peds.2015-3757","article-title":"Apnea of prematurity","volume":"137","author":"Eichenwald","year":"2016","journal-title":"Pediatrics"},{"key":"R14-20250604","doi-asserted-by":"crossref","first-page":"597","DOI":"10.5664\/jcsm.2172","article-title":"Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine","volume":"8","author":"Berry","year":"2012","journal-title":"J Clin Sleep Med"},{"key":"R15-20250604","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1038\/s41390-019-0317-8","article-title":"Pre-Vent: the prematurity-related ventilatory control study","volume":"85","author":"Dennery","year":"2019","journal-title":"Pediatr Res"},{"key":"R16-20250604","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1038\/s41390-023-02839-0","article-title":"Maturation of cardioventilatory physiological trajectories in extremely preterm infants","volume":"95","author":"Weese-Mayer","year":"2024","journal-title":"Pediatr Res"},{"key":"R17-20250604","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1038\/pr.2016.58","article-title":"Clinical associations with immature breathing in preterm infants: part 2-periodic breathing","volume":"80","author":"Patel","year":"2016","journal-title":"Pediatr Res"},{"key":"R18-20250604","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1002\/ppul.26273","article-title":"Periodic breathing in clinically stable very preterm infants","volume":"58","author":"Yee","year":"2023","journal-title":"Pediatr Pulmonol"},{"key":"R19-20250604","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.clp.2019.05.006","article-title":"Intermittent hypoxemia in preterm infants","volume":"46","author":"Di Fiore","year":"2019","journal-title":"Clin Perinatol"},{"key":"R20-20250604","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jpeds.2010.01.046","article-title":"A higher incidence of intermittent hypoxemic episodes is associated with severe retinopathy of prematurity","volume":"157","author":"Di Fiore","year":"2010","journal-title":"J Pediatr"},{"key":"R21-20250604","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1038\/pr.2012.132","article-title":"The relationship between patterns of intermittent hypoxia and retinopathy of prematurity in preterm infants","volume":"72","author":"Di Fiore","year":"2012","journal-title":"Pediatr Res"},{"key":"R22-20250604","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1038\/s41390-018-0253-z","article-title":"Neonatal intermittent hypoxemia events are associated with diagnosis of bronchopulmonary dysplasia at 36\u200aweeks postmenstrual age","volume":"85","author":"Raffay","year":"2019","journal-title":"Pediatr Res"},{"key":"R23-20250604","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1038\/s41390-018-0223-5","article-title":"Oxygen desaturations in the early neonatal period predict development of bronchopulmonary dysplasia","volume":"85","author":"Fairchild","year":"2019","journal-title":"Pediatr Res"},{"key":"R24-20250604","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.1164\/rccm.202105-1150OC","article-title":"Association between intermittent hypoxemia and severe bronchopulmonary dysplasia in preterm infants","volume":"204","author":"Jensen","year":"2021","journal-title":"Am J Respir Crit Care Med"},{"key":"R25-20250604","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1001\/jama.2015.8841","article-title":"Association between intermittent hypoxemia or bradycardia and late death or disability in extremely preterm infants","volume":"314","author":"Poets","year":"2015","journal-title":"JAMA"},{"key":"R26-20250604","doi-asserted-by":"crossref","first-page":"105919","DOI":"10.1016\/j.earlhumdev.2023.105919","article-title":"Association between intermittent hypoxemia and neurodevelopmental outcomes in extremely premature infants: a single-center experience","volume":"188","author":"Kim","year":"2024","journal-title":"Early Hum Dev"},{"key":"R27-20250604","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1164\/rccm.202210-1971OC","article-title":"Cardiorespiratory monitoring data to predict respiratory outcomes in extremely preterm infants","volume":"208","author":"Ambalavanan","year":"2023","journal-title":"Am J Respir Crit Care Med"},{"key":"R28-20250604","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1038\/s41372-023-01748-8","article-title":"Developmental consequences of short apneas and periodic breathing in preterm infants","volume":"43","author":"Yee","year":"2023","journal-title":"J Perinatol"},{"key":"R29-20250604","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1016\/j.sleep.2024.05.040","article-title":"Longitudinal effects of early exposure to intermittent hypoxia on autonomic cardiovascular control in very preterm infants","volume":"119","author":"Horne","year":"2024","journal-title":"Sleep Med"},{"key":"R30-20250604","doi-asserted-by":"crossref","first-page":"14","DOI":"10.5385\/nm.2021.28.1.14","article-title":"Cerebral oxygenation during apnea in preterm infants: effects of accompanying peripheral oxygen desaturation","volume":"28","author":"Choi","year":"2021","journal-title":"Neonatal Med"},{"key":"R31-20250604","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1038\/pr.2017.330","article-title":"Patterns of reintubation in extremely preterm infants: a longitudinal cohort study","volume":"83","author":"Shalish","year":"2018","journal-title":"Pediatr Res"},{"key":"R32-20250604","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.jpeds.2018.09.062","article-title":"The impact of time interval between extubation and reintubation on death or bronchopulmonary dysplasia in extremely preterm infants","volume":"205","author":"Shalish","year":"2019","journal-title":"J Pediatr"},{"key":"R33-20250604","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1542\/peds.111.1.146","article-title":"Cost-effectiveness analysis of predischarge monitoring for apnea of prematurity","volume":"111","author":"Zupancic","year":"2003","journal-title":"Pediatrics"},{"key":"R34-20250604","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1542\/peds.108.4.928","article-title":"Inter-neonatal intensive care unit variation in discharge timing: influence of apnea and feeding management","volume":"108","author":"Eichenwald","year":"2001","journal-title":"Pediatrics"},{"key":"R35-20250604","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1159\/000535264","article-title":"Association between intermittent hypoxemia and NICU length of stay in preterm infants","volume":"121","author":"Hibbs","year":"2024","journal-title":"Neonatology"},{"key":"R36-20250604","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1002\/jhm.2520","article-title":"Systematic review of physiologic monitor alarm characteristics and pragmatic interventions to reduce alarm frequency","volume":"11","author":"Paine","year":"2016","journal-title":"J Hosp Med"},{"key":"R37-20250604","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/jhm.2331","article-title":"Association between exposure to nonactionable physiologic monitor alarms and response time in a children's hospital","volume":"10","author":"Bonafide","year":"2015","journal-title":"J Hosp Med"},{"key":"R38-20250604","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1001\/jamapediatrics.2016.5123","article-title":"Video analysis of factors associated with response time to physiologic monitor alarms in a children's hospital","volume":"171","author":"Bonafide","year":"2017","journal-title":"JAMA Pediatr"},{"key":"R39-20250604","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1542\/peds.72.4.541","article-title":"Undetected episodes of prolonged apnea and severe bradycardia in preterm infants","volume":"72","author":"Southall","year":"1983","journal-title":"Pediatrics"},{"key":"R40-20250604","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1002\/ppul.1950110302","article-title":"Undetected apnea and bradycardia in infants","volume":"11","author":"Graff","year":"1991","journal-title":"Pediatr Pulmonol"},{"key":"R41-20250604","doi-asserted-by":"crossref","first-page":"F524","DOI":"10.1136\/archdischild-2012-303369","article-title":"Under-recognition of alarms in a neonatal intensive care unit","volume":"98","author":"Brockmann","year":"2013","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"R42-20250604","first-page":"643","article-title":"Monitoring apnea of prematurity: validity of nursing documentation and bedside cardiorespiratory monitor","volume":"30","author":"Amin","year":"2013","journal-title":"Am J Perinatol"},{"key":"R43-20250604","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1136\/adc.55.1.63","article-title":"An explanation for failure of impedance apnoea alarm systems","volume":"55","author":"Southall","year":"1980","journal-title":"Arch Dis Child"},{"key":"R44-20250604","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1088\/0143-0815\/4\/1\/010","article-title":"Long-term respiration monitoring in infants--a comparison of impedance and pressure capsule monitors","volume":"4","author":"Railton","year":"1983","journal-title":"Clin Phys Physiol Meas"},{"key":"R45-20250604","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1136\/adc.56.8.645","article-title":"Bradycardia and associated respiratory changes in neonates","volume":"56","author":"Smith","year":"1981","journal-title":"Arch Dis Child"},{"key":"R46-20250604","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1542\/peds.60.5.742","article-title":"Apnea monitor failure in infants with upper airway obstruction","volume":"60","author":"Warburton","year":"1977","journal-title":"Pediatrics"},{"key":"R47-20250604","first-page":"713","article-title":"Neonatal apnea: diagnosis by nurse versus computer","volume":"82","author":"Muttitt","year":"1988","journal-title":"Pediatrics"},{"key":"R48-20250604","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.5664\/jcsm.9264","article-title":"Polysomnography use in complex term and preterm infants to facilitate evaluation and management in the neonatal intensive care unit","volume":"17","author":"Kim","year":"2021","journal-title":"J Clin Sleep Med"},{"key":"R49-20250604","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1016\/j.jpeds.2011.06.044","article-title":"Mortality reduction by heart rate characteristic monitoring in very low birth weight neonates: a randomized trial","volume":"159","author":"Moorman","year":"2011","journal-title":"J Pediatr"},{"key":"R50-20250604","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.jpeds.2020.08.036","article-title":"Cerebral oxygenation and autoregulation in preterm infants (Early NIRS Study)","volume":"227","author":"Chock","year":"2020","journal-title":"J Pediatr"},{"key":"R51-20250604","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.jpeds.2018.11.038","article-title":"Low cerebral oxygenation in preterm infants is associated with adverse neurodevelopmental outcome","volume":"207","author":"Alderliesten","year":"2019","journal-title":"J Pediatr"},{"key":"R52-20250604","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1038\/s41372-018-0075-1","article-title":"Splanchnic NIRS monitoring in neonatal care: rationale, current applications and future perspectives","volume":"38","author":"Martini","year":"2018","journal-title":"J Perinatol"},{"key":"R53-20250604","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1136\/archdischild-2022-325245","article-title":"Clinical usefulness of reintubation criteria in extremely preterm infants: a cohort study","volume":"108","author":"Alarcon-Martinez","year":"2023","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"(S 01)","key":"R54-20250604","first-page":"e2348","article-title":"The alarm fatigue challenge in the neonatal intensive care unit: a \u2018before\u2019 and \u2018after\u2019 study","volume":"41","author":"Stiglich","year":"2024","journal-title":"Am J Perinatol"},{"key":"R55-20250604","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1055\/s-0038-1653945","article-title":"Reducing alarm fatigue in two neonatal intensive care units through a quality improvement collaboration","volume":"35","author":"Johnson","year":"2018","journal-title":"Am J Perinatol"},{"key":"R56-20250604","doi-asserted-by":"crossref","first-page":"357","DOI":"10.3233\/NPM-16162","article-title":"Alarms, oxygen saturations, and SpO2 averaging time in the NICU","volume":"9","author":"McClure","year":"2016","journal-title":"J Neonatal Perinatal Med"},{"key":"R57-20250604","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/978-3-030-34461-0_36","article-title":"Reducing false alarm rates in neonatal intensive care: a new machine learning approach","volume":"1232","author":"Ostojic","year":"2020","journal-title":"Adv Exp Med Biol"},{"key":"R58-20250604","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0967-3334\/33\/1\/1","article-title":"A new algorithm for detecting central apnea in neonates","volume":"33","author":"Lee","year":"2012","journal-title":"Physiol Meas"},{"key":"R59-20250604","first-page":"157","article-title":"Accurate automated apnea analysis in preterm infants","volume":"31","author":"Vergales","year":"2014","journal-title":"Am J Perinatol"},{"key":"R60-20250604","doi-asserted-by":"crossref","first-page":"107155","DOI":"10.1016\/j.cmpb.2022.107155","article-title":"Central apnea detection in premature infants using machine learning","volume":"226","author":"Varisco","year":"2022","journal-title":"Comput Methods Programs Biomed"},{"key":"R61-20250604","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6579\/ad2291","article-title":"Detecting central apneas using multichannel signals in premature infants","volume":"45","author":"Varisco","year":"2024","journal-title":"Physiol Meas"},{"key":"R62-20250604","doi-asserted-by":"crossref","first-page":"3574","DOI":"10.1002\/ppul.26695","article-title":"Cardiorespiratory monitoring with a wireless and nonadhesive belt measuring diaphragm activity in preterm and term infants: a multicenter noninferiority study","volume":"58","author":"Scholten","year":"2023","journal-title":"Pediatr Pulmonol"},{"key":"R63-20250604","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1038\/s41390-023-02800-1","article-title":"Diaphragmatic electromyography in infants: an overview of possible clinical applications","volume":"95","author":"Scholten","year":"2024","journal-title":"Pediatr Res"},{"key":"R64-20250604","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1136\/bmjinnov-2016-000145","article-title":"\u2018There were more wires than him\u2019: the potential for wireless patient monitoring in neonatal intensive care","volume":"3","author":"Bonner","year":"2017","journal-title":"BMJ Innov"},{"key":"R65-20250604","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1186\/s40560-015-0120-5","article-title":"Bacterial contamination of inanimate surfaces and equipment in the intensive care unit","volume":"3","author":"Russotto","year":"2015","journal-title":"J Intensive Care"},{"key":"R66-20250604","doi-asserted-by":"crossref","first-page":"2745","DOI":"10.1111\/jocn.13259","article-title":"Systematic review of qualitative studies exploring parental experiences in the neonatal intensive care unit","volume":"25","author":"Al Maghaireh","year":"2016","journal-title":"J Clin Nurs"},{"key":"R67-20250604","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.compbiomed.2016.11.010","article-title":"Monitoring infants by automatic video processing: a unified approach to motion analysis","volume":"80","author":"Cattani","year":"2017","journal-title":"Comput Biol Med"},{"key":"R68-20250604","first-page":"E171","article-title":"Non-contact video-based neonatal respiratory monitoring","volume":"7","author":"Rossol","year":"2020","journal-title":"Children (Basel)"},{"key":"R69-20250604","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1007\/s10877-022-00945-8","article-title":"Noncontact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates","volume":"37","author":"Maurya","year":"2023","journal-title":"J Clin Monit Comput"},{"key":"R70-20250604","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1093\/sleep\/8.4.342","article-title":"A comparison of tracheal breath sounds, airflow, and impedance pneumography in the detection of childhood apnea","volume":"8","author":"Beckerman","year":"1985","journal-title":"Sleep"},{"key":"R71-20250604","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/00003246-198206000-00005","article-title":"Tracheal breath sounds for detection of apnea in infants and children","volume":"10","author":"Beckerman","year":"1982","journal-title":"Crit Care Med"},{"key":"R72-20250604","doi-asserted-by":"crossref","first-page":"e0177926","DOI":"10.1371\/journal.pone.0177926","article-title":"Automatic adventitious respiratory sound analysis: a systematic review","volume":"12","author":"Pramono","year":"2017","journal-title":"PLoS One"},{"key":"R73-20250604","doi-asserted-by":"crossref","first-page":"285","DOI":"10.5664\/jcsm.7634","article-title":"Comparison of apnea detection using oronasal thermal airflow sensor, nasal pressure transducer, respiratory inductance plethysmography and tracheal sound sensor","volume":"15","author":"Sabil","year":"2019","journal-title":"J Clin Sleep Med"},{"key":"R74-20250604","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1542\/peds.86.6.950","article-title":"Microphonic versus end-tidal carbon dioxide nasal airflow detection in neonates with apnea","volume":"86","author":"Toubas","year":"1990","journal-title":"Pediatrics"},{"key":"R75-20250604","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1111\/pan.12254","article-title":"Accuracy of acoustic respiration rate monitoring in pediatric patients","volume":"23","author":"Patino","year":"2013","journal-title":"Paediatr Anaesth"},{"key":"R76-20250604","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1038\/s41551-019-0480-6","article-title":"Mechano-acoustic sensing of physiological processes and body motions via a soft wireless device placed at the suprasternal notch","volume":"4","author":"Lee","year":"2020","journal-title":"Nat Biomed Eng"},{"key":"R77-20250604","doi-asserted-by":"crossref","first-page":"e2104925118","DOI":"10.1073\/pnas.2104925118","article-title":"Miniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants","volume":"118","author":"Jeong","year":"2021","journal-title":"Proc Natl Acad Sci U S A"},{"key":"R78-20250604","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.resp.2013.11.003","article-title":"Respiratory rate assessments using a dual-accelerometer device","volume":"191","author":"Lapi","year":"2014","journal-title":"Respir Physiol Neurobiol"},{"key":"R79-20250604","doi-asserted-by":"crossref","first-page":"eaau0780","DOI":"10.1126\/science.aau0780","article-title":"Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care","volume":"363","author":"Chung","year":"2019","journal-title":"Science"},{"key":"R80-20250604","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1038\/s41591-020-0792-9","article-title":"Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units","volume":"26","author":"Chung","year":"2020","journal-title":"Nat Med"},{"key":"R81-20250604","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1542\/peds.71.1.53","article-title":"Apnea monitoring by acoustic detection of airflow","volume":"71","author":"Werthammer","year":"1983","journal-title":"Pediatrics"},{"key":"R82-20250604","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1002\/ppul.24633","article-title":"Acoustic analysis of neonatal breath sounds using digital stethoscope technology","volume":"55","author":"Zhou","year":"2020","journal-title":"Pediatr Pulmonol"},{"key":"R83-20250604","doi-asserted-by":"crossref","first-page":"3137","DOI":"10.1038\/s41591-023-02637-5","article-title":"Wireless broadband acousto-mechanical sensing system for continuous physiological monitoring","volume":"29","author":"Yoo","year":"2023","journal-title":"Nat Med"},{"key":"R84-20250604","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1038\/s41598-023-27399-5","article-title":"A machine learning approach to the development and prospective evaluation of a pediatric lung sound classification model","volume":"13","author":"Park","year":"2023","journal-title":"Sci Rep"},{"key":"R85-20250604","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1038\/s41390-018-0269-4","article-title":"Continuous pulse oximetry and respiratory rate trends predict short-term respiratory and growth outcomes in premature infants","volume":"85","author":"Warburton","year":"2019","journal-title":"Pediatr Res"},{"key":"R86-20250604","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1109\/JBHI.2019.2927463","article-title":"Predicting neonatal sepsis using features of heart rate variability, respiratory characteristics, and ECG-derived estimates of infant motion","volume":"24","author":"Joshi","year":"2020","journal-title":"IEEE J Biomed Health Inform"},{"key":"R87-20250604","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1055\/s-0037-1608709","article-title":"Cross-correlation of heart rate and oxygen saturation in very low birthweight infants: association with apnea and adverse events","volume":"35","author":"Fairchild","year":"2018","journal-title":"Am J Perinatol"},{"key":"R88-20250604","doi-asserted-by":"crossref","first-page":"114042","DOI":"10.1016\/j.jpeds.2024.114042","article-title":"Apnea, intermittent hypoxemia, and bradycardia events predict late-onset sepsis in infants born extremely preterm","volume":"271","author":"Kausch","year":"2024","journal-title":"J Pediatr"},{"key":"R89-20250604","article-title":"Clinical correlates of a high cardiorespiratory risk score for very low birth weight infants","author":"Kausch","year":"2024","journal-title":"Pediatr Res"},{"key":"R90-20250604","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1038\/s41390-022-02210-9","article-title":"Automated prediction of extubation success in extremely preterm infants: the APEX multicenter study","volume":"93","author":"Kanbar","year":"2023","journal-title":"Pediatr Res"},{"key":"R91-20250604","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1007\/s10877-022-00840-2","article-title":"Assessment of neonatal respiratory rate variability","volume":"36","author":"Coleman","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R92-20250604","doi-asserted-by":"crossref","first-page":"570","DOI":"10.3389\/fped.2020.00570","article-title":"Predicting apnoeic events in preterm infants","volume":"8","author":"Lim","year":"2020","journal-title":"Front Pediatr"},{"key":"R93-20250604","doi-asserted-by":"crossref","first-page":"416","DOI":"10.4187\/respcare.04102","article-title":"The objective use of pulse oximetry to predict respiratory support transition in preterm infants: an observational pilot study","volume":"61","author":"Mascoll-Robertson","year":"2016","journal-title":"Respir Care"},{"key":"R94-20250604","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1038\/s41372-019-0486-7","article-title":"Oxygen saturation histogram monitoring to reduce death or retinopathy of prematurity: a quality improvement initiative","volume":"40","author":"Gentle","year":"2020","journal-title":"J Perinatol"},{"key":"R95-20250604","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/s00431-020-03732-2","article-title":"Histogram analysis for bedside respiratory monitoring in not critically ill preterm neonates: a proposal for a new way to look at the monitoring data","volume":"180","author":"Sur","year":"2021","journal-title":"Eur J Pediatr"},{"key":"R96-20250604","article-title":"Neuromonitoring practices for neonates with congenital heart disease: a scoping review","author":"Pardo","year":"2024","journal-title":"Pediatr Res"},{"key":"R97-20250604","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1038\/s41390-022-02392-2","article-title":"Neuromonitoring in neonatal critical care part II: extremely premature infants and critically ill neonates","volume":"94","author":"El-Dib","year":"2023","journal-title":"Pediatr Res"},{"key":"R98-20250604","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1136\/archdischild-2022-324282","article-title":"Lung volume changes during apnoeas in preterm infants","volume":"108","author":"Gaertner","year":"2023","journal-title":"Arch Dis Child Fetal Neonatal Ed"}],"container-title":["Current Opinion in Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MOP.0000000000001432","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T09:00:31Z","timestamp":1749027631000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MOP.0000000000001432"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,11]]},"references-count":98,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/mop.0000000000001432","relation":{},"ISSN":["1531-698X"],"issn-type":[{"value":"1531-698X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,11]]}}}