{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T23:52:35Z","timestamp":1782604355634,"version":"3.54.5"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Pancreas"],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The aims of this study were to analyze the continuous glucose monitoring (CGM) profiles of patients with insulinoma before and after treatment with endoscopic ultrasound\u2013guided ethanol injection and assess the value of CGM in curative effect evaluating.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>We included 8 patients, and CGM was performed for 3 to 5 days before and after treatment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The proportion of monitoring points at which the glucose level was lower than 3.9 mmol\/L after treatment decreased in patient 5 (from 4% to 3%) and patient 8 (from 30% to 12%), whereas the proportion increased in patient 1 (from 1% to 16%), patient 3 (from 5% to 23%), and patient 7 (from 7% to 63%). There was no mean significant difference between CGM values (5.75 [standard deviation, 2.49] mmol\/L) and self-monitoring of blood glucose values (5.76 [standard deviation, 2.32] mmol\/L) (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.05). Pearson correlation analysis showed positive correlation between CGM values and self-monitoring of blood glucose values (<jats:italic toggle=\"yes\">r<\/jats:italic> = 0.88, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). Clarke Error Grid Analysis showed that 91.5% of pairs were located in areas A and B.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Continuous glucose monitoring is useful for detecting hypoglycemia and evaluating curative effect, but the correction of fingertip blood glucose is necessary when the blood glucose is relatively low.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mpa.0000000000001735","type":"journal-article","created":{"date-parts":[[2021,2,21]],"date-time":"2021-02-21T19:54:05Z","timestamp":1613937245000},"page":"183-188","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Continuous Glucose Monitoring in Patients With Insulinoma Treated by Endoscopic Ultrasound-Guided Ethanol Injection"],"prefix":"10.1097","volume":"50","author":[{"given":"Tao","family":"Yuan","sequence":"first","affiliation":[{"name":"Department of Endocrinology, Key Laboratory of Endocrinology of National Health Commission"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shixuan","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Endocrinology, Key Laboratory of Endocrinology of National Health Commission"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Zhu","sequence":"additional","affiliation":[{"name":"Gastroenterology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingyue","family":"Dong","sequence":"additional","affiliation":[{"name":"Department of Endocrinology, Key Laboratory of Endocrinology of National Health Commission"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huijuan","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Endocrinology, Key Laboratory of Endocrinology of National Health Commission"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xi","family":"Wu","sequence":"additional","affiliation":[{"name":"Gastroenterology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Tang","sequence":"additional","affiliation":[{"name":"Pharmacy, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weigang","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Endocrinology, Key Laboratory of Endocrinology of National Health Commission"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,2,8]]},"reference":[{"key":"bib1-20250808","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.endonu.2015.04.004","article-title":"Insulinoma: a multicenter, retrospective analysis of three decades of experience (1983\u20132014)","volume":"62","year":"2015","journal-title":"Endocrinol Nutr"},{"key":"bib2-20250808","doi-asserted-by":"crossref","first-page":"829","DOI":"10.3748\/wjg.v19.i6.829","article-title":"Diagnosis and management of insulinoma","volume":"19","year":"2013","journal-title":"World J Gastroenterol"},{"key":"bib3-20250808","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/S0889-8529(05)70084-0","article-title":"Symptoms of hypoglycemia, thresholds for their occurrence, and hypoglycemia unawareness","volume":"28","year":"1999","journal-title":"Endocrinol Metab Clin North Am"},{"key":"bib4-20250808","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1677\/ERC-07-0221","article-title":"Pancreatic endocrine neoplasms: epidemiology and prognosis of pancreatic endocrine tumors","volume":"15","year":"2008","journal-title":"Endocr Relat Cancer"},{"key":"bib5-20250808","doi-asserted-by":"crossref","first-page":"3067","DOI":"10.2169\/internalmedicine.8766-16","article-title":"Insulinoma presenting with reactive hypoglycemia: evaluating the effect of tumor resection via continuous glucose monitoring","volume":"56","year":"2017","journal-title":"Intern Med"},{"key":"bib6-20250808","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.diabres.2017.08.005","article-title":"Continuous glucose monitoring: a review of the technology and clinical use","volume":"133","year":"2017","journal-title":"Diabetes Res Clin Pract"},{"key":"bib7-20250808","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s12020-016-0902-0","article-title":"Spontaneous hypoglycemia: diagnostic evaluation and management","volume":"53","year":"2016","journal-title":"Endocrine"},{"key":"bib8-20250808","doi-asserted-by":"crossref","first-page":"489","DOI":"10.14310\/horm.2002.1706","article-title":"Glycemic control in patients with insulinoma","volume":"15","year":"2016","journal-title":"Hormones (Athens)"},{"key":"bib9-20250808","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1111\/j.1365-2265.2007.03161.x","article-title":"Continuous glucose monitoring in patients with insulinoma","volume":"68","year":"2008","journal-title":"Clin Endocrinol (Oxf)"},{"key":"bib10-20250808","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s13098-017-0215-3","article-title":"Characteristics of glucose metabolism indexes and continuous glucose monitoring system (CGMS) in patients with insulinoma","volume":"9","year":"2017","journal-title":"Diabetol Metab Syndr"},{"key":"bib11-20250808","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1177\/1932296814532203","article-title":"A comparative effectiveness analysis of three continuous glucose monitors: the Navigator, G4 Platinum, and Enlite","volume":"8","year":"2014","journal-title":"J Diabetes Sci Technol"},{"key":"bib12-20250808","doi-asserted-by":"crossref","first-page":"622","DOI":"10.2337\/diacare.10.5.622","article-title":"Evaluating clinical accuracy of systems for self-monitoring of blood glucose","volume":"10","year":"1987","journal-title":"Diabetes Care"},{"key":"bib13-20250808","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1111\/j.2040-1124.2012.00197.x","article-title":"Continuous glucose monitoring system: is it really accurate, safe and clinically useful?","volume":"3","year":"2012","journal-title":"J Diabetes Investig"},{"key":"bib14-20250808","doi-asserted-by":"crossref","first-page":"582","DOI":"10.2337\/diacare.26.3.582","article-title":"Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs","volume":"26","year":"2003","journal-title":"Diabetes Care"},{"key":"bib15-20250808","doi-asserted-by":"crossref","first-page":"2871","DOI":"10.2337\/diacare.28.12.2871","article-title":"Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients","volume":"28","year":"2005","journal-title":"Diabetes Care"},{"issue":"S3","key":"bib16-20250808","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.1089\/dia.2017.0035","article-title":"Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes","volume":"19","year":"2017","journal-title":"Diabetes Technol Ther"}],"container-title":["Pancreas"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MPA.0000000000001735","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,8]],"date-time":"2025-08-08T11:05:02Z","timestamp":1754651102000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MPA.0000000000001735"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/mpa.0000000000001735","relation":{},"ISSN":["1536-4828","0885-3177"],"issn-type":[{"value":"1536-4828","type":"electronic"},{"value":"0885-3177","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]}}}