{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T16:52:21Z","timestamp":1794847941688,"version":"4.9.1"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Pancreas"],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The aim of the study is to evaluate the usefulness of virtual monoenergetic imaging (VMI) generated from dual-energy computed tomography (DECT) in detecting small pancreatic ductal adenocarcinomas (PDACs).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This study included 82 patients pathologically diagnosed with small PDAC (\u226430 mm) and 20 without pancreatic tumors who underwent triple-phase contrast-enhanced DECT. To assess diagnostic performance for small PDAC detection via a receiver operating characteristic analysis, 3 observers reviewed 2 image sets (conventional computed tomography [CT] set and combined image set [conventional CT + 40-keV VMI from DECT]). The tumor-to-pancreas contrast-to-noise ratio was compared between conventional CT and 40-keV VMI from DECT.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The area under the receiver operating characteristic curve of the 3 observers were 0.97, 0.96, and 0.97 in conventional CT set and 0.99, 0.99, and 0.99 in combined image set (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.017\u20130.028), respectively. The combined image set yielded a better sensitivity than the conventional CT set (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.001\u20130.023), without a loss of specificity (all <jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.999). The tumor-to-pancreas contrast-to-noise ratios of 40-keV VMI from DECT were approximately threefold higher than those of conventional CT at all phases.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The addition of 40-keV VMI from DECT to conventional CT had better sensitivity for detecting small PDACs without compromising specificity.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mpa.0000000000002207","type":"journal-article","created":{"date-parts":[[2023,4,26]],"date-time":"2023-04-26T17:01:49Z","timestamp":1682528509000},"page":"1352-1358","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":17,"title":["Value of Dual-Energy Computed Tomography for Detecting Small Pancreatic Ductal Adenocarcinoma"],"prefix":"10.1097","volume":"51","author":[{"given":"Yosuke","family":"Fujisaki","sequence":"first","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihiko","family":"Fukukura","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichi","family":"Kumagae","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumitaka","family":"Ejima","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryoji","family":"Yamagishi","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinya","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junki","family":"Kamizono","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kurahara","sequence":"additional","affiliation":[{"name":"Digestive Surgery, Breast and Thyroid Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinichi","family":"Hashimoto","sequence":"additional","affiliation":[{"name":"Digestive and Lifestyle Diseases, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Yoshiura","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20250808","first-page":"7","article-title":"Cancer statistics, 2021","volume":"71","year":"2021","journal-title":"CA Cancer J Clin"},{"key":"bib2-20250808","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1245\/s10434-006-9249-8","article-title":"Trends in the treatment and outcome of pancreatic cancer in the United States","volume":"14","year":"2007","journal-title":"Ann Surg Oncol"},{"issue":"suppl 5","key":"bib3-20250808","first-page":"v56","article-title":"Cancer of the pancreas: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up","volume":"26","year":"2015","journal-title":"Ann Oncol"},{"key":"bib4-20250808","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1056\/NEJMra1404198","article-title":"Pancreatic adenocarcinoma","volume":"371","year":"2014","journal-title":"N Engl J Med"},{"key":"bib5-20250808","doi-asserted-by":"crossref","first-page":"4538","DOI":"10.1200\/JCO.2005.23.911","article-title":"Locally advanced pancreatic cancer","volume":"23","year":"2005","journal-title":"J Clin Oncol"},{"key":"bib6-20250808","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1097\/MPA.0b013e318258055c","article-title":"Japan Pancreatic Cancer Registry; 30th year anniversary: Japan Pancreas Society","volume":"41","year":"2012","journal-title":"Pancreas"},{"key":"bib7-20250808","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.ejrad.2017.04.009","article-title":"Imaging modalities in the diagnosis of pancreatic adenocarcinoma: a systematic review and meta-analysis of sensitivity, specificity and diagnostic accuracy","volume":"92","year":"2017","journal-title":"Eur J Radiol"},{"key":"bib8-20250808","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1148\/radiol.2243011284","article-title":"Isoattenuating pancreatic adenocarcinoma at multi-detector row CT: secondary signs","volume":"224","year":"2002","journal-title":"Radiology"},{"key":"bib9-20250808","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1148\/radiol.10100015","article-title":"Visually isoattenuating pancreatic adenocarcinoma at dynamic-enhanced CT: frequency, clinical and pathologic characteristics, and diagnosis at imaging examinations","volume":"257","year":"2010","journal-title":"Radiology"},{"key":"bib10-20250808","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1148\/radiol.11101133","article-title":"Small (\u2264 20 mm) pancreatic adenocarcinomas: analysis of enhancement patterns and secondary signs with multiphasic multidetector CT","volume":"259","year":"2011","journal-title":"Radiology"},{"key":"bib11-20250808","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.suronc.2015.09.006","article-title":"The isoattenuating pancreatic adenocarcinoma: review of the literature and critical analysis","volume":"24","year":"2015","journal-title":"Surg Oncol"},{"key":"bib12-20250808","doi-asserted-by":"crossref","first-page":"888","DOI":"10.2214\/AJR.20.25430","article-title":"Adding delayed phase images to dual-phase contrast-enhanced CT increases sensitivity for small pancreatic ductal adenocarcinoma","volume":"217","year":"2021","journal-title":"AJR Am J Roentgenol"},{"key":"bib13-20250808","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1007\/s00261-018-1754-2","article-title":"Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT","volume":"44","year":"2019","journal-title":"Abdom Radiol (NY)"},{"key":"bib14-20250808","doi-asserted-by":"crossref","first-page":"3617","DOI":"10.1007\/s00330-019-06116-9","article-title":"Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma","volume":"29","year":"2019","journal-title":"Eur Radiol"},{"key":"bib15-20250808","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/RCT.0000000000000492","article-title":"Use of a noise optimized monoenergetic algorithm for patient-size independent selection of an optimal energy level during dual-energy CT of the pancreas","volume":"41","year":"2017","journal-title":"J Comput Assist Tomogr"},{"key":"bib16-20250808","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1097\/RCT.0000000000000295","article-title":"Quantitative and qualitative comparison of single-source dual-energy computed tomography and 120-kVp computed tomography for the assessment of pancreatic ductal adenocarcinoma","volume":"39","year":"2015","journal-title":"J Comput Assist Tomogr"},{"key":"bib17-20250808","doi-asserted-by":"crossref","first-page":"2052","DOI":"10.1016\/j.ejrad.2015.07.020","article-title":"Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm","volume":"84","year":"2015","journal-title":"Eur J Radiol"},{"key":"bib18-20250808","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/RCT.0000000000000276","article-title":"Application of an advanced image-based virtual monoenergetic reconstruction of dual source dual-energy CT data at low keV increases image quality for routine pancreas imaging","volume":"39","year":"2015","journal-title":"J Comput Assist Tomogr"},{"key":"bib19-20250808","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1007\/s00261-014-0274-y","article-title":"Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT","volume":"40","year":"2015","journal-title":"Abdom Imaging"},{"key":"bib20-20250808","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1007\/s00330-019-06337-y","article-title":"Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma","volume":"30","year":"2020","journal-title":"Eur Radiol"},{"key":"bib21-20250808","doi-asserted-by":"crossref","first-page":"320.e17","DOI":"10.1016\/j.crad.2019.11.012","article-title":"Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT","volume":"75","year":"2020","journal-title":"Clin Radiol"},{"key":"bib22-20250808","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.crad.2012.06.108","article-title":"Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast","volume":"68","year":"2013","journal-title":"Clin Radiol"},{"key":"bib23-20250808","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1148\/radiology.199.3.8637990","article-title":"Two-phase helical CT for pancreatic tumors: pancreatic versus hepatic phase enhancement of tumor, pancreas, and vascular structures","volume":"199","year":"1996","journal-title":"Radiology"},{"key":"bib25-20250808","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1016\/j.ejrad.2013.12.016","article-title":"Contrast-enhanced CT and diffusion-weighted MR imaging: performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma","volume":"83","year":"2014","journal-title":"Eur J Radiol"},{"key":"bib26-20250808","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.ejrad.2007.09.012","article-title":"Diagnostic value of the delayed phase image for iso-attenuating pancreatic carcinomas in the pancreatic parenchymal phase on multidetector computed tomography","volume":"69","year":"2009","journal-title":"Eur J Radiol"},{"key":"bib27-20250808","doi-asserted-by":"crossref","first-page":"2837","DOI":"10.1007\/s00330-018-5789-0","article-title":"Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: impact of closing k-edge on image quality and lesion detectability","volume":"29","year":"2019","journal-title":"Eur Radiol"},{"key":"bib28-20250808","doi-asserted-by":"crossref","first-page":"025027","DOI":"10.1088\/1361-6560\/aa9e1b","article-title":"Objective image characterization of a spectral CT scanner with dual-layer detector","volume":"63","year":"2018","journal-title":"Phys Med Biol"},{"key":"bib29-20250808","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ejrad.2017.11.005","article-title":"Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner","volume":"98","year":"2018","journal-title":"Eur J Radiol"},{"key":"bib30-20250808","doi-asserted-by":"crossref","first-page":"2745","DOI":"10.1007\/s00330-017-5238-5","article-title":"Dual-energy CT: a phantom comparison of different platforms for abdominal imaging","volume":"28","year":"2018","journal-title":"Eur Radiol"}],"container-title":["Pancreas"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MPA.0000000000002207","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,8]],"date-time":"2025-08-08T11:05:59Z","timestamp":1754651159000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MPA.0000000000002207"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11]]},"references-count":29,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/mpa.0000000000002207","relation":{},"ISSN":["1536-4828","0885-3177"],"issn-type":[{"value":"1536-4828","type":"electronic"},{"value":"0885-3177","type":"print"}],"subject":[],"published":{"date-parts":[[2022,11]]}}}