{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,19]],"date-time":"2023-09-19T08:29:18Z","timestamp":1695112158051},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:p>Diagnosis of hereditary spherocytosis (HS) is based on clinical evaluation and eosin-5\u2032-maleimide (EMA) test. A decrease in EMA fluorescence compared with healthy individuals is typical for HS and serves as a basis for HS diagnosis. Sensitivity and specificity of the test is high and false-positive results rarely occur. Studies have shown that anticoagulated blood sample when stored at 4\u00b0C for 7 days do not affect the test results. This case study is about an autoimmune hemolytic anemia patient who showed a primary positive result for EMA test (decrease in EMA fluorescence\u201447% compared with 100% for samples of healthy individual), when the test was performed in the sample stored for 48 hours after venipuncture and before staining. An irrelevant decrease (92.5% compared with 100% for samples of healthy individual) was found when freshly collected sample was analyzed. On the basis of the results obtained, it is recommended that EMA staining should be performed on the same day of blood collection for patients with significant hemolysis.<\/jats:p>","DOI":"10.1097\/mph.0000000000000652","type":"journal-article","created":{"date-parts":[[2016,7,27]],"date-time":"2016-07-27T23:38:43Z","timestamp":1469662723000},"page":"e303-e306","source":"Crossref","is-referenced-by-count":2,"title":["Delayed Measurement of Eosin-5\u2032-Maleimide Binding May Affect the Test Results of Highly Hemolyzed Samples In Vivo and In Vitro\u2014A Case Study"],"prefix":"10.1097","volume":"38","author":[{"given":"Olga","family":"Ciepiela","sequence":"first","affiliation":[{"name":"Laboratory Diagnostics and Clinical Immunology of Developmental Age"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Adamowicz-Salach","sequence":"additional","affiliation":[{"name":"Paediatrics, Haematology and Oncology, Medical University of Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Izabela","family":"Zdziechowicz","sequence":"additional","affiliation":[{"name":"Paediatrics, Haematology and Oncology, Medical University of Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iwona","family":"Kotu\u0142a","sequence":"additional","affiliation":[{"name":"Laboratory Diagnostics and Clinical Immunology of Developmental Age"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230918","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1111\/ijlh.12335","article-title":"ICSH guidelines for the laboratory diagnosis of nonimmune hereditary red cell membrane disorders","volume":"37","author":"King","year":"2015","journal-title":"Int J Lab Haematol"},{"key":"R2-20230918","article-title":"Improved harmonization of eosin-5-maleimide binding test across different instruments and age groups","author":"Agarwal","year":"2015","journal-title":"Cytometry B Clin Cytom"},{"key":"R3-20230918","doi-asserted-by":"crossref","first-page":"1959","DOI":"10.1007\/s00277-015-2491-z","article-title":"Early postnatal diagnosis of hereditary spherocytosis by combining light microscopy, acidified glycerol lysis test and eosin-5\u2019-maleimide binding assay","volume":"94","author":"Andres","year":"2015","journal-title":"Ann Hematol"},{"key":"R4-20230918","doi-asserted-by":"crossref","first-page":"516","DOI":"10.3324\/haematol.2011.052845","article-title":"Diagnostic power of laboratory tests for hereditary spherocytosis: a comparison study in 150 patients grouped according to molecular and clinical characteristics","volume":"97","author":"Bianchi","year":"2012","journal-title":"Haematologica"},{"key":"R5-20230918","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1515\/cclm-2012-0240","article-title":"A delay in the measurement of eosin-5\u2019-maleimide binding (EMA) does not affect the test result for the diagnosis of hereditary spherocytosis","volume":"51","author":"Ciepiela","year":"2013","journal-title":"Clin Chem Lab Med"},{"key":"R6-20230918","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1111\/j.1365-2141.2007.06944.x","article-title":"Usefulness of the eosin-5\u2019-maleimide cytometric method as a first-line screening test for the diagnosis of hereditary spherocytosis: comparison with ektacytometry and protein electrophoresis","volume":"140","author":"Girodon","year":"2008","journal-title":"Br J Haematol"},{"key":"R7-20230918","first-page":"924","article-title":"Rapid flow cytometric test for the diagnosis of membrane cytoskeleton-associated haemolytic anaemia","volume":"111","author":"King","year":"2000","journal-title":"Br J Haematol"},{"key":"R8-20230918","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/S0031-3939(09)70105-2","article-title":"Evaluation of long-term blood sample storage and its influence on result of EMA binding test analysis. Initial report [in Polish]","volume":"84","author":"Szmydki-Baran","year":"2009","journal-title":"Pediatr Pol"},{"key":"R9-20230918","first-page":"598","article-title":"Flow cytometric test using eosin-5\u2019-maleimide (EMA) labelling of red blood for diagnosis of hereditary spherocytosis","volume":"36","author":"Wang","year":"2015","journal-title":"Zhonghua Xue Ye Xue Za Zhi"},{"key":"R10-20230918","doi-asserted-by":"crossref","first-page":"8630","DOI":"10.1021\/bi012007e","article-title":"Binding of hemoglobin to red cell membranes with eosin-5-maleimide-labeled band 3: analysis of centrifugation and fluorescence data","volume":"41","author":"Demehin","year":"2002","journal-title":"Biochemistry"},{"key":"R11-20230918","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1111\/j.1537-2995.2009.02133.x","article-title":"Changes in Band 3 oligomeric state precede cell membrane phospholipid loss during blood bank storage of red blood cells","volume":"49","author":"Karon","year":"2009","journal-title":"Transfusion"},{"key":"R12-20230918","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1046\/j.1365-2141.2003.04730.x","article-title":"Eosin-5-maleimide binding to band 3 and Rh-related proteins forms the basis of a screening test for hereditary spherocytosis","volume":"124","author":"King","year":"2004","journal-title":"Br J Haematol"}],"container-title":["Journal of Pediatric Hematology\/Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00043426-201611000-00025","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T04:09:32Z","timestamp":1695010172000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00043426-201611000-00025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":12,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/mph.0000000000000652","relation":{},"ISSN":["1077-4114"],"issn-type":[{"value":"1077-4114","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]}}}