{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T21:58:45Z","timestamp":1777327125088,"version":"3.51.4"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2024,12,12]],"date-time":"2024-12-12T00:00:00Z","timestamp":1733961600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Drug-coated balloons (DCBs) have emerged as a potential option for treating in-stent restenosis (ISR). We aimed to assess the efficacy and safety of DCB compared to uncoated balloons (UCBs) for patients with ISR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We systematically searched Embase, MEDLINE, and Cochrane Library for randomized controlled trials comparing drug-coated balloons with uncoated balloons for coronary in-stent restenosis (ISR). Dichotomous and continuous outcomes were pooled using Revman 5.4 under a random-effects model. All the outcomes were assessed in a 6-month to 1-year follow-up period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of seven RCTs involving 1407 patients were included in our review. DCBs significantly reduced the rate of target lesion revascularization (TLR) (RR 0.28; 95% CI: 0.16, 0.48), target vessel revascularization (TVR) (RR 0.36; 95% CI: 0.14, 0.90), major adverse cardiovascular events (MACE) (RR 0.39; 95% CI: 0.26, 0.58), and MI (RR 0.56; 95% CI: 0.35, 0.91). However, no significant difference was observed between the two groups regarding all-cause mortality, cardiovascular mortality, and stent thrombosis. DCB significantly improved angiographic outcomes such as binary restenosis (RR 0.23; 95% CI: 0.12, 0.43), late lumen loss (MD \u22120.44; 95% CI:\u00a0\u2212\u00a00.55 to \u22120.33), and percent diameter stenosis (MD \u221213.91; 95% CI:\u00a0\u2212\u00a024.15 to \u22123.67) compared to the UCB group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Our meta-analysis showed that drug-coated balloons have superior efficacy and safety compared to uncoated balloons in coronary in-stent restenosis patients.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ms9.0000000000003496","type":"journal-article","created":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T15:00:19Z","timestamp":1750431619000},"page":"5165-5172","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Drug-coated balloons for the treatment of in-stent restenosis: an updated systematic review and meta-analysis of randomized controlled trials"],"prefix":"10.1097","volume":"87","author":[{"given":"Manojna","family":"Guntipalli","sequence":"first","affiliation":[{"name":"GITAM Institute of Medical Sciences and Research, Visakhapatnam, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ogechukwu","family":"Obi","sequence":"additional","affiliation":[{"name":"New York Institute of Technology College of Osteopathic Medicine, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teenu Maria","family":"Jeswin","sequence":"additional","affiliation":[{"name":"Department of Medicine, Doncaster Royal Infirmary, Doncaster, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rushern","family":"Naidoo","sequence":"additional","affiliation":[{"name":"Department of Medicine, Caucasus International University, Tbilisi, Georgia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed Amine","family":"Ghenai","sequence":"additional","affiliation":[{"name":"Department of Medicine, Universit\u00e9 de Montreal, Montreal, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nishi","family":"Kansara","sequence":"additional","affiliation":[{"name":"Surat Municipal Institute of Medical Education and Research, Surat, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Syed Karam","family":"Gardezi","sequence":"additional","affiliation":[{"name":"T.J. Samson Community Hospital, Glasgow, Kentucky, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Chathemparambil Mani","sequence":"additional","affiliation":[{"name":"Department of Radiology, MES Medical College, Perinthalmanna, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taqiyah","family":"Sheriff","sequence":"additional","affiliation":[{"name":"Batterjee Medical College, Jeddah, Saudi Arabia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sinda","family":"Hidri","sequence":"additional","affiliation":[{"name":"East Carolina University, Greenville, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muhammad","family":"Ehsan","sequence":"additional","affiliation":[{"name":"Department of Medicine, King Edward Medical University, Lahore, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wajeeh Ur","family":"Rehman","sequence":"additional","affiliation":[{"name":"Department of Medicine, United Health Services, Johnson, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asmaa","family":"Munasar","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Sana\u2019a University, Sana\u2019a, Yemen"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,12,12]]},"reference":[{"key":"R1-20250806","first-page":"15\u201323","article-title":"Fremdk\u00f6rper-reaktionen auf biomaterialien und strategien zum funktionserhalt von implantaten","volume":"11","author":"Hartmann","year":"2010","journal-title":"BioNanoMaterials"},{"key":"R2-20250806","doi-asserted-by":"crossref","first-page":"E1150","DOI":"10.21037\/jtd.2016.10.93","article-title":"Understanding and managing in-stent restenosis: a review of clinical data, from pathogenesis to treatment","volume":"8","author":"Buccheri","year":"2016","journal-title":"J Thorac Dis"},{"key":"R3-20250806","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.3390\/jcm13082377","article-title":"Current management of in-stent restenosis","volume":"13","author":"Giacoppo","year":"2024","journal-title":"J Clin Med"},{"key":"R4-20250806","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1097\/00041433-199912000-00004","article-title":"Pathology of in-stent restenosis","volume":"10","author":"Virmani","year":"1999","journal-title":"Curr Opin Lipidol"},{"key":"R5-20250806","doi-asserted-by":"crossref","first-page":"8104939","DOI":"10.1155\/2020\/8104939","article-title":"In-stent restenosis and a drug-coated balloon: insights from a clinical therapeutic strategy on coronary artery diseases","volume":"2020","author":"Zhang","year":"2020","journal-title":"Cardiol Res Pract"},{"key":"R6-20250806","doi-asserted-by":"crossref","first-page":"4\u201312","DOI":"10.1016\/j.ijcard.2011.08.855","article-title":"Paclitaxel coated balloons for coronary artery interventions: a comprehensive review of preclinical and clinical data","volume":"161","author":"Cortese","year":"2012","journal-title":"Int J Cardiol"},{"key":"R7-20250806","doi-asserted-by":"crossref","first-page":"352\u201358","DOI":"10.1161\/CIRCINTERVENTIONS.109.873703","article-title":"Drug-eluting balloon: the comeback kid?","volume":"2","author":"Waksman","year":"2009","journal-title":"Circ Cardiovasc Interv"},{"key":"R8-20250806","doi-asserted-by":"crossref","first-page":"618\u201322","DOI":"10.1016\/S0002-9149(96)00381-5","article-title":"Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis","volume":"78","author":"Mehran","year":"1996","journal-title":"Am J Cardiol"},{"key":"R9-20250806","doi-asserted-by":"crossref","first-page":"1451\u201354","DOI":"10.1016\/j.amjcard.2006.07.027","article-title":"Comparison with conventional therapies of repeated sirolimus-eluting stent implantation for the treatment of drug-eluting coronary stent restenosis","volume":"98","author":"Kim","year":"2006","journal-title":"Am J Cardiol"},{"key":"R10-20250806","doi-asserted-by":"crossref","first-page":"2152\u201360","DOI":"10.1016\/j.jacc.2005.10.078","article-title":"A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis: results of the restenosis intrastent: balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial","volume":"47","author":"Alfonso","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"R11-20250806","doi-asserted-by":"crossref","first-page":"165\u201371","DOI":"10.1001\/jama.293.2.165","article-title":"Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis: a randomized controlled trial","volume":"293","author":"Kastrati","year":"2005","journal-title":"JAMA"},{"key":"R13-20250806","doi-asserted-by":"crossref","first-page":"1015\u201324","DOI":"10.1001\/jama.2024.1361","article-title":"Paclitaxel-coated balloon vs uncoated balloon for coronary in-stent restenosis: the agent ide randomized clinical trial","volume":"331","author":"Yeh","year":"2024","journal-title":"JAMA"},{"key":"R14-20250806","doi-asserted-by":"crossref","first-page":"1695\u2013700","DOI":"10.1016\/j.jcin.2015.07.023","article-title":"Long-term outcomes after treatment with a paclitaxel-coated balloon versus balloon angioplasty","volume":"8","author":"Rittger","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"R15-20250806","doi-asserted-by":"crossref","first-page":"461\u20137","DOI":"10.1016\/S0140-6736(12)61964-3","article-title":"Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial","volume":"381","author":"Byrne","year":"2013","journal-title":"Lancet"},{"key":"R16-20250806","first-page":"51\u201359","article-title":"A novel drug-coated scoring balloon for the treatment of coronary in-stent restenosis: results from the multi-center randomized controlled PATENT-C first in human trial","volume":"88","author":"Scheller","year":"2016","journal-title":"Catheter Cardiovasc Interv"},{"key":"R17-20250806","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"R19-20250806","doi-asserted-by":"crossref","first-page":"5928","DOI":"10.1136\/bmj.d5928","article-title":"The cochrane collaboration\u2019s tool for assessing risk of bias in randomised trials","volume":"343:d","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"R20-20250806","doi-asserted-by":"crossref","first-page":"527\u201333","DOI":"10.1016\/j.ahj.2013.07.002","article-title":"A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosis","volume":"166","author":"Habara","year":"2013","journal-title":"Am Heart J"},{"key":"R21-20250806","doi-asserted-by":"crossref","first-page":"149\u201354","DOI":"10.1016\/j.jcin.2010.10.012","article-title":"Effectiveness of paclitaxel-eluting balloon catheter in patients with sirolimus-eluting stent restenosis","volume":"4","author":"Habara","year":"2011","journal-title":"JACC Cardiovasc Interv"},{"key":"R22-20250806","doi-asserted-by":"crossref","first-page":"323\u201330","DOI":"10.1016\/j.jcin.2012.01.008","article-title":"Long-term follow-up after treatment of coronary In-stent restenosis with a paclitaxel-coated balloon catheter","volume":"5","author":"Scheller","year":"2012","journal-title":"JACC Cardiovasc Interv"},{"key":"R23-20250806","doi-asserted-by":"crossref","first-page":"877\u201384","DOI":"10.1016\/j.jcin.2015.01.031","article-title":"Long-term efficacy and safety of paclitaxel-eluting balloon for the treatment of drug-eluting stent restenosis: 3-year results of a randomized controlled trial","volume":"8","author":"Kufner","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"R25-20250806","doi-asserted-by":"crossref","first-page":"e27521","DOI":"10.1016\/j.heliyon.2024.e27521","article-title":"Comparative efficacy of interventional therapies and devices for coronary in-stent restenosis: a systematic review and network meta-analysis of randomized controlled trials","volume":"10","author":"Guo","year":"2024","journal-title":"Heliyon"},{"issue":"7","key":"R28-20250806","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.jcin.2023.01.380","article-title":"Assessment of Paclitaxel Drug-Coated Balloon Only Angioplasty in STEMI","volume":"16","author":"Merinopoulos","journal-title":"JACC. Cardiovascular interventions"},{"issue":"12","key":"R31-20250806","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1016\/j.jcin.2020.02.043","article-title":"International DCB Consensus Group (2020). Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group","volume":"13","author":"Jeger","journal-title":"JACC. Cardiovascular interventions"}],"container-title":["Annals of Medicine &amp; Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MS9.0000000000003496","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,6]],"date-time":"2025-08-06T16:15:49Z","timestamp":1754496949000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MS9.0000000000003496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,12]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/ms9.0000000000003496","relation":{},"ISSN":["2049-0801"],"issn-type":[{"value":"2049-0801","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,12]]},"assertion":[{"value":"2025-01-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}