{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:24:02Z","timestamp":1790789042317,"version":"4.1.0"},"reference-count":271,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T00:00:00Z","timestamp":1654041600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Clinics are treating a growing number of patients with greater amounts of residual hearing. These patients often benefit from a bimodal hearing configuration in which acoustic input from a hearing aid on 1 ear is combined with electrical stimulation from a cochlear implant on the other ear. The current guidelines aim to review the literature and provide best practice recommendations for the evaluation and treatment of individuals with bilateral sensorineural hearing loss who may benefit from bimodal hearing configurations. Specifically, the guidelines review: benefits of bimodal listening, preoperative and postoperative cochlear implant evaluation and programming, bimodal hearing aid fitting, contralateral routing of signal considerations, bimodal treatment for tinnitus, and aural rehabilitation recommendations.<\/jats:p>","DOI":"10.1097\/ono.0000000000000011","type":"journal-article","created":{"date-parts":[[2022,8,5]],"date-time":"2022-08-05T20:03:44Z","timestamp":1659729824000},"page":"e011","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":25,"title":["Guidelines for Best Practice in the Audiological Management of Adults Using Bimodal Hearing Configurations"],"prefix":"10.1097","volume":"2","author":[{"given":"Jourdan T.","family":"Holder","sequence":"first","affiliation":[{"name":"Vanderbilt University Medical Center, Nashville, TN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meredith A.","family":"Holcomb","sequence":"additional","affiliation":[{"name":"University of Miami, Miami, FL"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hillary","family":"Snapp","sequence":"additional","affiliation":[{"name":"University of Miami, Miami, FL"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert F.","family":"Labadie","sequence":"additional","affiliation":[{"name":"Medical University of South Carolina, Charleston, SC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jantien","family":"Vroegop","sequence":"additional","affiliation":[{"name":"Erasmus Medical Center, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Rocca","sequence":"additional","affiliation":[{"name":"Guy\u2019s and St. Thomas\u2019 Hearing Implant Centre, London, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed Salah","family":"Elgandy","sequence":"additional","affiliation":[{"name":"University of Iowa, Iowa City, IA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Camille","family":"Dunn","sequence":"additional","affiliation":[{"name":"University of Iowa, Iowa City, IA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9 H.","family":"Gifford","sequence":"additional","affiliation":[{"name":"Vanderbilt University Medical Center, Nashville, TN"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,6]]},"reference":[{"key":"R1-20241014","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1097\/AUD.0000000000000657","article-title":"Bimodal hearing or bilateral cochlear implants? Ask the patient.","volume":"40","author":"Gifford","year":"2019","journal-title":"Ear Hear"},{"key":"R2-20241014","first-page":"1014","article-title":"Self-reported usage, functional benefit, and audiologic characteristics of cochlear implant patients who use a contralateral hearing aid.","volume":"21","author":"Neuman","year":"2017","journal-title":"Trends Hear"},{"key":"R3-20241014","doi-asserted-by":"crossref","first-page":"1561","DOI":"10.1044\/2020_JSLHR-19-00304","article-title":"Clinical application of spectral modulation detection: speech recognition benefit for combining a cochlear implant and contralateral hearing aid.","volume":"63","author":"Kessler","year":"2020","journal-title":"J Speech Lang Hear Res"},{"key":"R4-20241014","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1097\/AUD.0000000000000150","article-title":"A retrospective multicenter study comparing speech perception outcomes for bilateral implantation and bimodal rehabilitation.","volume":"36","author":"Blamey","year":"2015","journal-title":"Ear Hear"},{"key":"R5-20241014","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1159\/000355700","article-title":"Availability of binaural cues for bilateral implant recipients and bimodal listeners with and without preserved hearing in the implanted ear.","volume":"19","author":"Gifford","year":"2014","journal-title":"Audiol Neurootol"},{"key":"R6-20241014","doi-asserted-by":"crossref","first-page":"e240","DOI":"10.1097\/MAO.0000000000000529","article-title":"Evaluation of the bimodal benefit in a large cohort of cochlear implant subjects using a contralateral hearing aid.","volume":"35","author":"Illg","year":"2014","journal-title":"Otol Neurotol"},{"key":"R7-20241014","doi-asserted-by":"crossref","first-page":"2331216520902001","DOI":"10.1177\/2331216520902001","article-title":"Frequency following response and speech recognition benefit for combining a cochlear implant and contralateral hearing aid.","volume":"24","author":"Kessler","year":"2020","journal-title":"Trends Hear"},{"key":"R8-20241014","article-title":"Perception of sung speech in bimodal cochlear implant users.","volume":"20","author":"Crew","year":"2016","journal-title":"Trends Hear"},{"key":"R9-20241014","doi-asserted-by":"crossref","first-page":"S19","DOI":"10.1097\/MAO.0000000000003375","article-title":"Bimodal hearing with pediatric cochlear implant recipients: effect of acoustic bandwidth.","volume":"42","author":"Gifford","year":"2021","journal-title":"Otol Neurotol"},{"key":"R10-20241014","doi-asserted-by":"crossref","first-page":"4610592","DOI":"10.1155\/2018\/4610592","article-title":"The benefits of residual hair cell function for speech and music perception in pediatric bimodal cochlear implant listeners.","volume":"2018","author":"Cheng","year":"2018","journal-title":"Neural Plast"},{"key":"R11-20241014","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1097\/AUD.0000000000000401","article-title":"Sound localization and speech perception in noise of pediatric cochlear implant recipients: bimodal fitting versus bilateral cochlear implants.","volume":"38","author":"Choi","year":"2017","journal-title":"Ear Hear"},{"key":"R12-20241014","doi-asserted-by":"crossref","first-page":"393","DOI":"10.3766\/jaaa.26.4.7","article-title":"Evaluation of hearing aid frequency response fittings in pediatric and young adult bimodal recipients.","volume":"26","author":"Davidson","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R13-20241014","doi-asserted-by":"crossref","first-page":"3620","DOI":"10.1044\/2019_JSLHR-H-18-0255","article-title":"Effects of early acoustic hearing on speech perception and language for pediatric cochlear implant recipients.","volume":"62","author":"Davidson","year":"2019","journal-title":"J Speech Lang Hear Res"},{"key":"R14-20241014","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1044\/1092-4388(2005\/046)","article-title":"Benefit of wearing a hearing aid on the unimplanted ear in adult users of a cochlear implant.","volume":"48","author":"Dunn","year":"2005","journal-title":"J Speech Lang Hear Res"},{"key":"R15-20241014","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1159\/000357588","article-title":"The benefits of bimodal hearing: effect of frequency region and acoustic bandwidth.","volume":"19","author":"Sheffield","year":"2014","journal-title":"Audiol Neurootol"},{"key":"R16-20241014","article-title":"The benefits of bimodal aiding on extended dimensions of speech perception: intelligibility, listening effort, and sound quality.","volume":"21","author":"Devocht","year":"2017","journal-title":"Trends Hear"},{"key":"R17-20241014","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1097\/AUD.0000000000000548","article-title":"Results in adult cochlear implant recipients with varied asymmetric hearing: a prospective longitudinal study of speech recognition, localization, and participant report.","volume":"39","author":"Firszt","year":"2018","journal-title":"Ear Hear"},{"key":"R18-20241014","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1016\/j.amjoto.2009.04.002","article-title":"Benefit from bimodal hearing in a group of prelingually deafened adult cochlear implant users.","volume":"31","author":"Berrettini","year":"2010","journal-title":"Am J Otolaryngol"},{"key":"R19-20241014","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1044\/2020_JSLHR-20-00390","article-title":"Bimodal benefit for music perception: effect of acoustic bandwidth.","volume":"64","author":"D\u2019Onofrio","year":"2021","journal-title":"J Speech Lang Hear Res"},{"key":"R20-20241014","doi-asserted-by":"crossref","first-page":"114","DOI":"10.3389\/fnins.2020.00114","article-title":"Musical emotion perception in bimodal patients: relative weighting of musical mode and tempo cues.","volume":"14","author":"D\u2019Onofrio","year":"2020","journal-title":"Front Neurosci"},{"key":"R21-20241014","doi-asserted-by":"crossref","first-page":"558421","DOI":"10.3389\/fnins.2021.558421","article-title":"Participation of acoustic and electric hearing in perceiving musical sounds.","volume":"15","author":"Duret","year":"2021","journal-title":"Front Neurosci"},{"key":"R22-20241014","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1097\/AUD.0000000000000418","article-title":"Combined electric and acoustic stimulation with hearing preservation: effect of cochlear implant low-frequency cutoff on speech understanding and perceived listening difficulty.","volume":"38","author":"Gifford","year":"2017","journal-title":"Ear Hear"},{"key":"R24-20241014","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1097\/MAO.0000000000002664","article-title":"Development of a 60\/60 guideline for referring adults for a traditional cochlear implant candidacy evaluation.","volume":"41","author":"Zwolan","year":"2020","journal-title":"Otol Neurotol"},{"key":"R26-20241014","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1177\/0194599812438041","article-title":"Long-term performance of cochlear implants in postlingually deafened adults.","volume":"147","author":"Lenarz","year":"2012","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R27-20241014","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/AUD.0000000000000248","article-title":"Effects of threshold adjustment on speech perception in nucleus cochlear implant recipients.","volume":"37","author":"Busby","year":"2016","journal-title":"Ear Hear"},{"key":"R28-20241014","doi-asserted-by":"crossref","first-page":"93","DOI":"10.3109\/14992020209090399","article-title":"Relationship of intraoperative electrically evoked stapedius reflex thresholds to maximum comfortable loudness levels of children with cochlear implants.","volume":"41","author":"Allum","year":"2002","journal-title":"Int J Audiol"},{"key":"R29-20241014","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1002\/cii.18","article-title":"Investigations into electrically evoked stapedius reflex measures and subjective loudness percepts in the MED-EL COMBI 40+ cochlear implant.","volume":"6","author":"Brickley","year":"2005","journal-title":"Cochlear Implants Int"},{"issue":"suppl 1","key":"R30-20241014","first-page":"S28","article-title":"Programming cochlear implant stimulation levels in infants and children with a combination of objective measures.","volume":"43","author":"Gordon","year":"2004","journal-title":"Int J Audiol"},{"key":"R31-20241014","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0194-5998(97)70183-9","article-title":"Electrical middle ear muscle reflex: use in cochlear implant programming.","volume":"117","author":"Hodges","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R32-20241014","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1080\/14670100.2004.11873748","article-title":"ESRT and MCL correlations in experienced paediatric cochlear implant users.","volume":"5","author":"Lorens","year":"2004","journal-title":"Cochlear Implants Int"},{"key":"R33-20241014","first-page":"175","article-title":"Relationships among comfort levels determined by cochlear implant patient\u2019s self-programming, audiologist\u2019s programming, and electrical stapedius reflex thresholds.","volume":"166","author":"Shallop","year":"1995","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"R34-20241014","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1288\/00005537-199410000-00007","article-title":"Programming the cochlear implant based on electrical acoustic reflex thresholds: patient performance.","volume":"104","author":"Spivak","year":"1994","journal-title":"Laryngoscope"},{"key":"R35-20241014","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/00206090009073049","article-title":"Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants.","volume":"39","author":"Stephan","year":"2000","journal-title":"Audiology"},{"key":"R36-20241014","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1159\/000326892","article-title":"Evoked stapedius reflex and compound action potential thresholds versus most comfortable loudness level: assessment of their relation for charge-based fitting strategies in implant users.","volume":"73","author":"Walkowiak","year":"2011","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"issue":"1 suppl","key":"R37-20241014","doi-asserted-by":"crossref","first-page":"24S","DOI":"10.1097\/01.AUD.0000051687.99218.0F","article-title":"Factors associated with development of speech perception skills in children implanted by age five.","volume":"24","author":"Geers","year":"2003","journal-title":"Ear Hear"},{"key":"R38-20241014","doi-asserted-by":"crossref","first-page":"EL81","DOI":"10.1121\/1.2761924","article-title":"Loudness growth in individual listeners with hearing losses: a review.","volume":"122","author":"Marozeau","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R39-20241014","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1179\/cim.2006.7.3.125","article-title":"Objective methods in postlingually and prelingually deafened adults for programming cochlear implants: ESR and NRT.","volume":"7","author":"Polak","year":"2006","journal-title":"Cochlear Implants Int"},{"key":"R40-20241014","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/MAO.0b013e318161aac7","article-title":"Electric charge requirements of pediatric cochlear implant recipients enrolled in the Childhood Development After Cochlear Implantation study.","volume":"29","author":"Zwolan","year":"2008","journal-title":"Otol Neurotol"},{"key":"R41-20241014","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1179\/cim.2003.4.4.161","article-title":"Comparison between NRT-based MAPs and behaviourally measured MAPs at different stimulation rates\u2013a multicentre investigation.","volume":"4","author":"Craddock","year":"2003","journal-title":"Cochlear Implants Int"},{"key":"R42-20241014","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/AUD.0000000000000495","article-title":"Use of electrically evoked compound action potentials for cochlear implant fitting: a systematic review.","volume":"39","author":"de Vos","year":"2018","journal-title":"Ear Hear"},{"issue":"suppl 1","key":"R43-20241014","doi-asserted-by":"crossref","first-page":"67S","DOI":"10.1097\/00003446-200202001-00008","article-title":"A model of a nucleus 24 cochlear implant fitting protocol based on the electrically evoked whole nerve action potential.","volume":"23","author":"Franck","year":"2002","journal-title":"Ear Hear"},{"key":"R44-20241014","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1097\/00003446-200108000-00004","article-title":"Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation\u2019s CI24M device.","volume":"22","author":"Franck","year":"2001","journal-title":"Ear Hear"},{"key":"R45-20241014","first-page":"260","article-title":"Using electrically evoked compound action potential thresholds to facilitate creating MAPs for children with the Nucleus CI24M.","volume":"57","author":"Hughes","year":"2000","journal-title":"Adv Otorhinolaryngol"},{"key":"R46-20241014","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3766\/jaaa.21.1.3","article-title":"Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the Advanced Bionics cochlear implant.","volume":"21","author":"Jeon","year":"2010","journal-title":"J Am Acad Audiol"},{"key":"R47-20241014","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1097\/MAO.0000000000001548","article-title":"Using electrically-evoked compound action potentials to estimate perceptive levels in experienced adult cochlear implant users.","volume":"38","author":"Joly","year":"2017","journal-title":"Otol Neurotol"},{"key":"R48-20241014","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1159\/000066154","article-title":"Speech perception in nucleus CI24M cochlear implant users with processor settings based on electrically evoked compound action potential thresholds.","volume":"7","author":"Smoorenburg","year":"2002","journal-title":"Audiol Neurootol"},{"key":"R49-20241014","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1001\/jamaoto.2020.1584","article-title":"Assessment of speech understanding after cochlear implantation in adult hearing aid users a nonrandomized controlled trial.","volume":"146","author":"Buchman","year":"2020","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R50-20241014","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1121\/1.421224","article-title":"Speech recognition of hearing-impaired listeners: predictions from audibility and the limited role of high-frequency amplification.","volume":"103","author":"Ching","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R51-20241014","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1097\/AUD.0000000000000577","article-title":"How to optimally fit a hearing aid for bimodal cochlear implant users: a systematic review.","volume":"39","author":"Vroegop","year":"2018","journal-title":"Ear Hear"},{"key":"R52-20241014","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/AUD.0000000000000597","article-title":"Comparing two hearing aid fitting algorithms for bimodal cochlear implant users.","volume":"40","author":"Vroegop","year":"2019","journal-title":"Ear Hear"},{"issue":"suppl 2","key":"R53-20241014","doi-asserted-by":"crossref","first-page":"S45","DOI":"10.3109\/14992027.2015.1133936","article-title":"Fitting recommendations and clinical benefit associated with use of the NAL-NL2 hearing-aid prescription in Nucleus cochlear implant recipients.","volume":"55","author":"English","year":"2016","journal-title":"Int J Audiol"},{"key":"R54-20241014","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1044\/2018_AJA-18-0067","article-title":"Comparing the effect of different hearing aid fitting methods in bimodal cochlear implant users.","volume":"28","author":"Vroegop","year":"2019","journal-title":"Am J Audiol"},{"key":"R55-20241014","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1080\/14992027.2019.1697902","article-title":"Comparison of bimodal benefit for the use of DSL v5.0 and NAL-NL2 in cochlear implant listeners.","volume":"59","author":"Digeser","year":"2020","journal-title":"Int J Audiol"},{"key":"R56-20241014","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1097\/MAO.0000000000002796","article-title":"Aligning hearing aid and cochlear implant improves hearing outcome in bimodal cochlear implant users.","volume":"41","author":"Holtmann","year":"2020","journal-title":"Otol Neurotol"},{"key":"R57-20241014","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1097\/AUD.0000000000000260","article-title":"Matching automatic gain control across devices in bimodal cochlear implant users.","volume":"37","author":"Veugen","year":"2016","journal-title":"Ear Hear"},{"key":"R58-20241014","doi-asserted-by":"crossref","first-page":"23312165211014139","DOI":"10.1177\/23312165211014139","article-title":"Synchronized automatic gain control in bilateral cochlear implant recipients yields significant benefit in static and dynamic listening conditions.","volume":"25","author":"Dwyer","year":"2021","journal-title":"Trends Hear"},{"key":"R59-20241014","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/00003446-200110000-00002","article-title":"Should children who use cochlear implants wear hearing aids in the opposite ear?","volume":"22","author":"Ching","year":"2001","journal-title":"Ear Hear"},{"key":"R60-20241014","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/01.AUD.0000111261.84611.C8","article-title":"Binaural benefits for adults who use hearing aids and cochlear implants in opposite ears.","volume":"25","author":"Ching","year":"2004","journal-title":"Ear Hear"},{"key":"R61-20241014","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1080\/00222930500271630","article-title":"The effect of auditory experience on speech perception, localization, and functional performance of children who use a cochlear implant and a hearing aid in opposite ears.","volume":"44","author":"Ching","year":"2005","journal-title":"Int J Audiol"},{"key":"R62-20241014","doi-asserted-by":"crossref","first-page":"EL87","DOI":"10.1121\/1.3298451","article-title":"The use of interaural time and level difference cues by bilateral cochlear implant users.","volume":"127","author":"Aronoff","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R63-20241014","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1097\/MAO.0b013e318278506d","article-title":"The effectiveness of bilateral cochlear implants for severe-to-profound deafness in adults: a systematic review.","volume":"34","author":"van Schoonhoven","year":"2013","journal-title":"Otol Neurotol"},{"key":"R64-20241014","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1159\/000493844","article-title":"The value of unilateral CIs, CI-CROS and bilateral CIs, with and without beamformer microphones, for speech understanding in a simulation of a restaurant environment.","volume":"23","author":"Dorman","year":"2018","journal-title":"Audiol Neurootol"},{"key":"R65-20241014","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1097\/01.aud.0000246816.50820.42","article-title":"Simultaneous bilateral cochlear implantation in adults: a multicenter clinical study.","volume":"27","author":"Litovsky","year":"2006","journal-title":"Ear Hear"},{"issue":"suppl 2","key":"R66-20241014","doi-asserted-by":"crossref","first-page":"80S","DOI":"10.1097\/AUD.0b013e3180315117","article-title":"More challenging speech-perception tasks demonstrate binaural benefit in bilateral cochlear implant users.","volume":"28","author":"Wackym","year":"2007","journal-title":"Ear Hear"},{"key":"R67-20241014","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/AUD.0b013e31815d636f","article-title":"Interaural time and level difference thresholds for acoustically presented signals in post-lingually deafened adults fitted with bilateral cochlear implants using CIS+ processing.","volume":"29","author":"Grantham","year":"2008","journal-title":"Ear Hear"},{"key":"R68-20241014","doi-asserted-by":"crossref","first-page":"33","DOI":"10.17430\/882761","article-title":"The psychophysics of low-frequency acoustic hearing in electric and acoustic stimulation (EAS) and bimodal patients.","volume":"2","author":"Gifford","year":"2012","journal-title":"J Hear Sci"},{"key":"R69-20241014","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1080\/00016480510027493","article-title":"Advantages of binaural hearing provided through bimodal stimulation via a cochlear implant and a conventional hearing aid: a 6-month comparative study.","volume":"125","author":"Morera","year":"2005","journal-title":"Acta Otolaryngol"},{"key":"R70-20241014","doi-asserted-by":"crossref","first-page":"2205","DOI":"10.1007\/s00405-019-05467-9","article-title":"Benefits of a contralateral routing of signal device for unilateral Na\u00edda CI cochlear implant recipients.","volume":"276","author":"Mosnier","year":"2019","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R71-20241014","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1121\/1.4955307","article-title":"Benefit of contralateral routing of signals for unilateral cochlear implant users.","volume":"140","author":"Taal","year":"2016","journal-title":"J Acoust Soc Am"},{"key":"R72-20241014","doi-asserted-by":"crossref","first-page":"579","DOI":"10.3766\/jaaa.17121","article-title":"Application of wireless contralateral routing of signal technology in unilateral cochlear implant users with bilateral profound hearing loss.","volume":"30","author":"Snapp","year":"2019","journal-title":"J Am Acad Audiol"},{"key":"R73-20241014","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1080\/14670100.2019.1586151","article-title":"Evaluation of a wireless contralateral routing of signal (CROS) device with the Advanced Bionics Na\u00edda CI Q90 sound processor.","volume":"20","author":"Ernst","year":"2019","journal-title":"Cochlear Implants Int"},{"key":"R74-20241014","doi-asserted-by":"crossref","first-page":"e233","DOI":"10.1097\/MAO.0000000000000461","article-title":"The addition of a contralateral microphone for unilateral cochlear implant users: not an alternative for bilateral cochlear implantation.","volume":"35","author":"van Loon","year":"2014","journal-title":"Otol Neurotol"},{"key":"R75-20241014","first-page":"235","article-title":"Contralateral routing of signal yields significant speech in noise benefit for unilateral cochlear implant recipients.","volume":"30","author":"Dwyer","year":"2019","journal-title":"J Am Acad Audiol"},{"key":"R76-20241014","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1097\/MAO.0000000000002955","article-title":"Cochlear implantation in adults with single-sided deafness: outcomes and device use.","volume":"42","author":"Deep","year":"2021","journal-title":"Otol Neurotol"},{"key":"R77-20241014","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.amjoto.2017.01.020","article-title":"Cochlear implantation for single-sided deafness and tinnitus suppression.","volume":"38","author":"Holder","year":"2017","journal-title":"Am J Otolaryngol"},{"key":"R78-20241014","doi-asserted-by":"crossref","first-page":"61","DOI":"10.4103\/1012-5574.199404","article-title":"Tinnitus suppression after cochlear implantation in patients with single-sided deafness.","volume":"33","author":"Ahmed","year":"2017","journal-title":"Egypt J Otolaryngol"},{"key":"R79-20241014","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1177\/0194599819846084","article-title":"The influence of cochlear implantation on tinnitus in patients with single-sided deafness: a systematic review.","volume":"161","author":"Peter","year":"2019","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R80-20241014","first-page":"237","article-title":"How does auditory training work? Joined-up thinking and listening.","volume":"36","author":"Ferguson","year":"2015","journal-title":"Semin Hear"},{"key":"R81-20241014","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1044\/2016_JSLHR-H-15-0162","article-title":"Examination of individual differences in outcomes from a randomized controlled clinical trial comparing formal and informal individual auditory training programs.","volume":"59","author":"Smith","year":"2016","journal-title":"J Speech Lang Hear Res"},{"key":"R82-20241014","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1001\/jamaoto.2020.0998","article-title":"Unilateral cochlear implants for severe, profound, or moderate sloping to profound bilateral sensorineural hearing loss: a systematic review and consensus statements.","volume":"146","author":"Buchman","year":"2020","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R83-20241014","doi-asserted-by":"crossref","first-page":"1820","DOI":"10.2105\/AJPH.2016.303299","article-title":"Prevalence of hearing loss by severity in the United States.","volume":"106","author":"Goman","year":"2016","journal-title":"Am J Public Health"},{"key":"R84-20241014","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1001\/archinternmed.2011.1408","article-title":"Prevalence of hearing aid use among older adults in the United States.","volume":"172","author":"Chien","year":"2012","journal-title":"Arch Intern Med"},{"issue":"suppl 1","key":"R86-20241014","first-page":"S4","article-title":"Cochlear implantation in the world\u2019s largest medical device market: utilization and awareness of cochlear implants in the United States.","volume":"14","author":"Sorkin","year":"2013","journal-title":"Cochlear Implants Int"},{"key":"R87-20241014","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1097\/MAO.0000000000003068","article-title":"Further evidence for the expansion of adult cochlear implant candidacy criteria.","volume":"42","author":"Perkins","year":"2021","journal-title":"Otol Neurotol"},{"key":"R89-20241014","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1001\/jamaoto.2019.3760","article-title":"Audiology practices in the preoperative evaluation and management of adult cochlear implant candidates.","volume":"146","author":"Prentiss","year":"2020","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R90-20241014","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1055\/s-0040-1714744","article-title":"Guidelines for best practice in the audiological management of adults with severe and profound hearing loss.","volume":"41","author":"Turton","year":"2020","journal-title":"Semin Hear"},{"key":"R91-20241014","doi-asserted-by":"crossref","first-page":"912","DOI":"10.3109\/14992027.2010.509113","article-title":"Combining acoustic and electric stimulation in the service of speech recognition.","volume":"49","author":"Dorman","year":"2010","journal-title":"Int J Audiol"},{"key":"R92-20241014","article-title":"Current profile of adults presenting for preoperative cochlear implant evaluation.","volume":"22","author":"Holder","year":"2018","journal-title":"Trends Hear"},{"key":"R93-20241014","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1044\/2018_AJA-17-0105","article-title":"Tinnitus suppression in cochlear implant patients using a sound therapy app.","volume":"27","author":"Tyler","year":"2018","journal-title":"Am J Audiol"},{"key":"R94-20241014","doi-asserted-by":"crossref","first-page":"6","DOI":"10.3766\/jaaa.18027","article-title":"Tinnitus sound therapy trial shows effectiveness for those with tinnitus.","volume":"31","author":"Tyler","year":"2020","journal-title":"J Am Acad Audiol"},{"key":"R95-20241014","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.heares.2011.11.014","article-title":"Contrasting benefits from contralateral implants and hearing aids in cochlear implant users.","volume":"288","author":"van Hoesel","year":"2012","journal-title":"Hear Res"},{"key":"R96-20241014","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/AUD.0b013e3181b7190c","article-title":"Information from the voice fundamental frequency (F0) region accounts for the majority of the benefit when acoustic stimulation is added to electric stimulation.","volume":"31","author":"Zhang","year":"2010","journal-title":"Ear Hear"},{"key":"R97-20241014","doi-asserted-by":"crossref","first-page":"1698","DOI":"10.1121\/1.1776192","article-title":"Localization ability with bimodal hearing aids and bilateral cochlear implants.","volume":"116","author":"Seeber","year":"2004","journal-title":"J Acoust Soc Am"},{"key":"R98-20241014","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/00003446-200204000-00003","article-title":"Patients utilizing a hearing aid and a cochlear implant: speech perception and localization.","volume":"23","author":"Tyler","year":"2002","journal-title":"Ear Hear"},{"key":"R99-20241014","doi-asserted-by":"crossref","first-page":"e0120279","DOI":"10.1371\/journal.pone.0120279","article-title":"Contributions of electric and acoustic hearing to bimodal speech and music perception.","volume":"10","author":"Crew","year":"2015","journal-title":"PLoS One"},{"key":"R100-20241014","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1159\/000111782","article-title":"The benefits of combining acoustic and electric stimulation for the recognition of speech, voice and melodies.","volume":"13","author":"Dorman","year":"2008","journal-title":"Audiol Neurootol"},{"issue":"suppl 1","key":"R101-20241014","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1159\/000206491","article-title":"How much residual hearing is \u2018useful\u2019 for music perception with cochlear implants?","volume":"14","author":"El Fata","year":"2009","journal-title":"Audiol Neurootol"},{"key":"R102-20241014","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1177\/000348941212101203","article-title":"Accuracy of cochlear implant recipients in speech reception in the presence of background music.","volume":"121","author":"Gfeller","year":"2012","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R103-20241014","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/01.AUD.0000120365.97792.2F","article-title":"Music perception with temporal cues in acoustic and electric hearing.","volume":"25","author":"Kong","year":"2004","journal-title":"Ear Hear"},{"key":"R104-20241014","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/AUD.0b013e318252caae","article-title":"Timbre and speech perception in bimodal and bilateral cochlear-implant listeners.","volume":"33","author":"Kong","year":"2012","journal-title":"Ear Hear"},{"key":"R105-20241014","doi-asserted-by":"crossref","first-page":"494","DOI":"10.3766\/jaaa.14098","article-title":"Differences in perception of musical stimuli among acoustic, electric, and combined modality listeners.","volume":"26","author":"Prentiss","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R106-20241014","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.heares.2014.09.010","article-title":"Factors constraining the benefit to speech understanding of combining information from low-frequency hearing and a cochlear implant.","volume":"322","author":"Dorman","year":"2015","journal-title":"Hear Res"},{"key":"R107-20241014","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/AUD.0b013e31815d7467","article-title":"Multicenter U.S. bilateral MED-EL cochlear implantation study: speech perception over the first year of use.","volume":"29","author":"Buss","year":"2008","journal-title":"Ear Hear"},{"key":"R108-20241014","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1097\/AUD.0b013e31806dc21a","article-title":"Horizontal-plane localization of noise and speech signals by postlingually deafened adults fitted with bilateral cochlear implants.","volume":"28","author":"Grantham","year":"2007","journal-title":"Ear Hear"},{"key":"R109-20241014","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1044\/2015_JSLHR-H-14-0355","article-title":"Using ILD or ITD cues for sound source localization and speech understanding in a complex listening environment by listeners with bilateral and with hearing-preservation cochlear implants.","volume":"59","author":"Loiselle","year":"2016","journal-title":"J Speech Lang Hear Res"},{"key":"R110-20241014","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1044\/1059-0889(2013\/11-0031)","article-title":"Transitioning from bimodal to bilateral cochlear implant listening: speech recognition and localization in four individuals.","volume":"23","author":"Potts","year":"2014","journal-title":"Am J Audiol"},{"key":"R111-20241014","doi-asserted-by":"crossref","first-page":"e551","DOI":"10.1097\/MAO.0000000000001524","article-title":"Effectiveness of directional microphones in bilateral\/bimodal cochlear implant users-impact of spatial and temporal noise characteristics.","volume":"38","author":"Weissgerber","year":"2017","journal-title":"Otol Neurotol"},{"key":"R112-20241014","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1097\/AUD.0000000000000712","article-title":"Factors affecting bimodal benefit in pediatric Mandarin-speaking Chinese cochlear implant users.","volume":"40","author":"Liu","year":"2019","journal-title":"Ear Hear"},{"key":"R113-20241014","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.heares.2014.02.005","article-title":"Contribution of bimodal hearing to lexical tone normalization in Mandarin-speaking cochlear implant users.","volume":"312","author":"Luo","year":"2014","journal-title":"Hear Res"},{"key":"R114-20241014","doi-asserted-by":"crossref","first-page":"S17","DOI":"10.1080\/14992027.2017.1321789","article-title":"Bimodal benefits in Mandarin-speaking cochlear implant users with contralateral residual acoustic hearing.","volume":"56","author":"Yang","year":"2017","journal-title":"Int J Audiol"},{"key":"R115-20241014","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1080\/14992027.2020.1719437","article-title":"Mandarin lexical tone recognition in bimodal cochlear implant users.","volume":"59","author":"Zhou","year":"2020","journal-title":"Int J Audiol"},{"key":"R116-20241014","doi-asserted-by":"crossref","first-page":"EL94","DOI":"10.1121\/1.3606460","article-title":"Binaural benefit for speech recognition with spectral mismatch across ears in simulated electric hearing.","volume":"130","author":"Yoon","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R117-20241014","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1179\/1754762814Y.0000000101","article-title":"Bimodal benefit depends on the performance difference between a cochlear implant and a hearing aid.","volume":"16","author":"Yoon","year":"2015","journal-title":"Cochlear Implants Int"},{"key":"R118-20241014","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1044\/1092-4388(2010\/10-0197)","article-title":"Cross-frequency integration for consonant and vowel identification in bimodal hearing.","volume":"54","author":"Kong","year":"2011","journal-title":"J Speech Lang Hear Res"},{"key":"R119-20241014","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1121\/1.1857526","article-title":"Speech and melody recognition in binaurally combined acoustic and electric hearing.","volume":"117","author":"Kong","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R120-20241014","doi-asserted-by":"crossref","first-page":"3717","DOI":"10.1121\/1.2717408","article-title":"Improved speech recognition in noise in simulated binaurally combined acoustic and electric stimulation.","volume":"121","author":"Kong","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R121-20241014","doi-asserted-by":"crossref","first-page":"145","DOI":"10.3766\/jaaa.26.2.5","article-title":"Preserved acoustic hearing in cochlear implantation improves speech perception.","volume":"26","author":"Sheffield","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R122-20241014","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1080\/00016489.2020.1780311","article-title":"Phoneme recognition in bimodal hearing.","volume":"140","author":"Shpak","year":"2020","journal-title":"Acta Otolaryngol"},{"key":"R123-20241014","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1159\/000113510","article-title":"Speech recognition materials and ceiling effects: considerations for cochlear implant programs.","volume":"13","author":"Gifford","year":"2008","journal-title":"Audiol Neurootol"},{"key":"R124-20241014","doi-asserted-by":"crossref","first-page":"e1111","DOI":"10.1097\/MAO.0000000000002767","article-title":"Are there real-world benefits to bimodal listening?","volume":"41","author":"Nyirjesy","year":"2020","journal-title":"Otol Neurotol"},{"key":"R125-20241014","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1097\/AUD.0b013e31826709af","article-title":"Relationship between auditory function of nonimplanted ears and bimodal benefit.","volume":"34","author":"Zhang","year":"2013","journal-title":"Ear Hear"},{"key":"R126-20241014","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1044\/1092-4388(2007\/057)","article-title":"Contribution of high frequencies to speech recognition in quiet and noise in listeners with varying degrees of high-frequency sensorineural hearing loss.","volume":"50","author":"Amos","year":"2007","journal-title":"J Speech Lang Hear Res"},{"key":"R127-20241014","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1121\/1.1498853","article-title":"Effects of low pass filtering on the intelligibility of speech in noise for people with and without dead regions at high frequencies.","volume":"112","author":"Baer","year":"2002","journal-title":"J Acoust Soc Am"},{"key":"R128-20241014","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1121\/1.423247","article-title":"High-frequency audibility: benefits for hearing-impaired listeners.","volume":"104","author":"Hogan","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R129-20241014","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1097\/AUD.0b013e31820e5028","article-title":"Effects of degree and configuration of hearing loss on the contribution of high- and low-frequency speech information to bilateral speech understanding.","volume":"32","author":"Hornsby","year":"2011","journal-title":"Ear Hear"},{"issue":"suppl 1","key":"R130-20241014","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1159\/000095606","article-title":"Hearing loss and the limits of amplification.","volume":"11","author":"Turner","year":"2006","journal-title":"Audiol Neurootol"},{"key":"R131-20241014","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1044\/1059-0889(1999\/002)","article-title":"Speech audibility for listeners with high-frequency hearing loss.","volume":"8","author":"Turner","year":"1999","journal-title":"Am J Audiol"},{"key":"R132-20241014","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1121\/1.1381534","article-title":"Effects of low-pass filtering on the intelligibility of speech in quiet for people with and without dead regions at high frequencies.","volume":"110","author":"Vickers","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R133-20241014","doi-asserted-by":"crossref","first-page":"2761","DOI":"10.1121\/1.428133","article-title":"Inter-relationship between different psychoacoustic measures assumed to be related to the cochlear active mechanism.","volume":"106","author":"Moore","year":"1999","journal-title":"J Acoust Soc Am"},{"key":"R134-20241014","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1121\/1.385827","article-title":"Shifts in phonetic identification with changes in signal presentation level.","volume":"69","author":"Dorman","year":"1981","journal-title":"J Acoust Soc Am"},{"key":"R135-20241014","doi-asserted-by":"crossref","first-page":"2964","DOI":"10.1121\/1.1369105","article-title":"The effects of compression ratio, signal-to-noise ratio, and level on speech recognition in normal-hearing listeners.","volume":"109","author":"Hornsby","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R136-20241014","doi-asserted-by":"crossref","first-page":"2431","DOI":"10.1121\/1.426848","article-title":"Monosyllabic word recognition at higher-than-normal speech and noise levels.","volume":"105","author":"Studebaker","year":"1999","journal-title":"J Acoust Soc Am"},{"key":"R137-20241014","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1044\/jslhr.4302.456","article-title":"Effect of compression ratio on speech recognition and speech-quality ratings with wide dynamic range compression amplification.","volume":"43","author":"Boike","year":"2000","journal-title":"J Speech Lang Hear Res"},{"key":"R138-20241014","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1044\/1092-4388(2007\/022)","article-title":"Ranking hearing aid input-output functions for understanding low-, conversational-, and high-level speech in multitalker babble.","volume":"50","author":"Chung","year":"2007","journal-title":"J Speech Lang Hear Res"},{"key":"R139-20241014","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1121\/1.413092","article-title":"The effect of multichannel dynamic compression on speech intelligibility.","volume":"97","author":"Hohmann","year":"1995","journal-title":"J Acoust Soc Am"},{"key":"R140-20241014","doi-asserted-by":"crossref","first-page":"872","DOI":"10.3766\/jaaa.18.10.6","article-title":"Speech recognition in quiet and noise in borderline cochlear implant candidates.","volume":"18","author":"Alkaf","year":"2007","journal-title":"J Am Acad Audiol"},{"key":"R141-20241014","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1097\/AUD.0b013e3181c6b831","article-title":"Evidence for the expansion of adult cochlear implant candidacy.","volume":"31","author":"Gifford","year":"2010","journal-title":"Ear Hear"},{"key":"R142-20241014","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/MAO.0000000000001271","article-title":"Older individuals meeting Medicare cochlear implant candidacy criteria in noise but not in quiet: are these patients improved by surgery?","volume":"38","author":"Mudery","year":"2017","journal-title":"Otol Neurotol"},{"key":"R143-20241014","doi-asserted-by":"crossref","first-page":"2368","DOI":"10.1002\/lary.26513","article-title":"Evaluation of a revised indication for determining adult cochlear implant candidacy.","volume":"127","author":"Sladen","year":"2017","journal-title":"Laryngoscope"},{"key":"R144-20241014","doi-asserted-by":"crossref","first-page":"102300","DOI":"10.1016\/j.amjoto.2019.102300","article-title":"Comprehensive hearing aid assessment in adults with bilateral severe-profound sensorineural hearing loss who present for cochlear implant evaluation.","volume":"41","author":"Lupo","year":"2020","journal-title":"Am J Otolaryngol"},{"key":"R145-20241014","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.otohns.2008.12.021","article-title":"Clinical implications of a damaged cochlea: pure tone thresholds vs information-carrying capacity.","volume":"140","author":"Halpin","year":"2009","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R146-20241014","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1097\/MAO.0b013e3182204526","article-title":"Implications of minimizing trauma during conventional cochlear implantation.","volume":"32","author":"Carlson","year":"2011","journal-title":"Otol Neurotol"},{"key":"R147-20241014","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1017\/S0022215115003436","article-title":"Preservation of cochlear structures and hearing when using the Nucleus Slim Straight (CI422) electrode in children.","volume":"130","author":"Skarzynski","year":"2016","journal-title":"J Laryngol Otol"},{"key":"R148-20241014","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1080\/00016480410018179","article-title":"Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study.","volume":"124","author":"Adunka","year":"2004","journal-title":"Acta Otolaryngol"},{"key":"R149-20241014","article-title":"Guideline for audiologic management of the adult patient.","author":"Valente","year":"2006","journal-title":"Audiol Online"},{"key":"R150-20241014","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1044\/1059-0889(1998\/012)","article-title":"Average speech levels and spectra in various speaking\/listening conditions: a summary of the Pearson, Bennett, & Fidell (1977) report.","volume":"7","author":"Olsen","year":"1998","journal-title":"Am J Audiol"},{"key":"R151-20241014","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/S0194-5998(97)70173-6","article-title":"Parameter selection to optimize speech recognition with the Nucleus implant.","volume":"117","author":"Skinner","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R152-20241014","first-page":"32","article-title":"Live voice speech recognition audiometry-- Stop the madness!","volume":"20","author":"Roeser","year":"2008","journal-title":"Audiol Today"},{"key":"R153-20241014","doi-asserted-by":"crossref","first-page":"e70","DOI":"10.1097\/MAO.0000000000000911","article-title":"Method of speech stimulus presentation impacts pediatric speech recognition: monitored live voice versus recorded speech.","volume":"37","author":"Uhler","year":"2016","journal-title":"Otol Neurotol"},{"key":"R154-20241014","first-page":"19","article-title":"MarkeTrak VIII: consumer satisfaction with hearing aids is slowly increasing.","volume":"63","author":"Kochkin","year":"2010","journal-title":"Hear J"},{"key":"R156-20241014","doi-asserted-by":"crossref","first-page":"183","DOI":"10.3766\/jaaa.26.2.7","article-title":"Estimation of signal-to-noise ratios in realistic sound scenarios.","volume":"26","author":"Smeds","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R157-20241014","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1080\/14992020400050014","article-title":"The speech, spatial and qualities of hearing scale (SSQ).","volume":"43","author":"Gatehouse","year":"2004","journal-title":"Int J Audiol"},{"key":"R158-20241014","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1097\/01.AUD.0000134552.22205.EE","article-title":"Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems.","volume":"25","author":"Firszt","year":"2004","journal-title":"Ear Hear"},{"key":"R159-20241014","doi-asserted-by":"crossref","first-page":"3554","DOI":"10.1044\/2019_JSLHR-H-19-0142","article-title":"Cochlear Implant-Quality of Life (CIQOL): development of a profile specific instrument (CIQOL-35 Profile) and a global measure (CIQOL-10 Global).","volume":"62","author":"McRackan","year":"2019","journal-title":"J Speech Hear Res"},{"key":"R160-20241014","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1017\/S0266462300102132","article-title":"The effect of cochlear implant use in postlingually deaf adults.","volume":"16","author":"Krabbe","year":"2000","journal-title":"Int J Technol Assess Health Care"},{"key":"R162-20241014","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1097\/00005537-200308000-00014","article-title":"Facial nerve paralysis following cochlear implant surgery.","volume":"113","author":"Fayad","year":"2003","journal-title":"Laryngoscope"},{"key":"R163-20241014","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1080\/14670100.2019.1625126","article-title":"Iatrogenic facial nerve exposure in cochlear implant surgery: incidence and clinical significance in the absence of intra-operative nerve monitoring.","volume":"20","author":"Mandour","year":"2019","journal-title":"Cochlear Implants Int"},{"key":"R164-20241014","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1017\/S0022215116010008","article-title":"Pre- and post-operative dizziness, tinnitus, and taste disturbances among cochlear implant recipients.","volume":"131","author":"Mikkelsen","year":"2017","journal-title":"J Laryngol Otol"},{"key":"R165-20241014","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/MAO.0000000000000920","article-title":"Outcomes after cochlear implantation in the very elderly.","volume":"37","author":"Wong","year":"2016","journal-title":"Otol Neurotol"},{"key":"R166-20241014","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1179\/cim.2007.8.4.203","article-title":"Taste change following cochlear implantation.","volume":"8","author":"Lloyd","year":"2007","journal-title":"Cochlear Implants Int"},{"key":"R167-20241014","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1080\/00016489.2018.1482422","article-title":"Postoperative infections following cochlear implant surgery.","volume":"138","author":"Olsen","year":"2018","journal-title":"Acta Otolaryngol"},{"issue":"suppl 2","key":"R168-20241014","doi-asserted-by":"crossref","first-page":"95S","DOI":"10.1097\/AUD.0b013e3180315502","article-title":"A multicenter study of device failure in European cochlear implant centers.","volume":"28","author":"Battmer","year":"2007","journal-title":"Ear Hear"},{"key":"R169-20241014","doi-asserted-by":"crossref","first-page":"e705","DOI":"10.1097\/MAO.0000000000002659","article-title":"Outcomes of revision cochlear implantation.","volume":"41","author":"Kimura","year":"2020","journal-title":"Otol Neurotol"},{"key":"R170-20241014","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1007\/s10162-007-0076-9","article-title":"Frequency map for the human cochlear spiral ganglion: implications for cochlear implants.","volume":"8","author":"Stakhovskaya","year":"2007","journal-title":"J Assoc Res Otolaryngol"},{"key":"R172-20241014","article-title":"Effects of tinnitus on cochlear implant programming.","volume":"23","author":"Pierzycki","year":"2019","journal-title":"Trends Hear"},{"issue":"suppl 4","key":"R173-20241014","doi-asserted-by":"crossref","first-page":"2S","DOI":"10.1097\/00003446-200508001-00002","article-title":"Effects of minimum stimulation settings for the Med El Tempo+ speech processor on speech understanding.","volume":"26","author":"Spahr","year":"2005","journal-title":"Ear Hear"},{"key":"R174-20241014","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1097\/MAO.0b013e3181eb320c","article-title":"Cochlear implant characteristics and speech perception skills of adolescents with long-term device use.","volume":"31","author":"Davidson","year":"2010","journal-title":"Otol Neurotol"},{"key":"R175-20241014","doi-asserted-by":"crossref","first-page":"302","DOI":"10.3766\/jaaa.23.5.2","article-title":"Optimization of programming parameters in children with the advanced bionics cochlear implant.","volume":"23","author":"Baudhuin","year":"2012","journal-title":"J Am Acad Audiol"},{"key":"R176-20241014","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1097\/MAO.0000000000001241","article-title":"Factors affecting outcomes in cochlear implant recipients implanted with a perimodiolar electrode array located in scala tympani.","volume":"37","author":"Holden","year":"2016","journal-title":"Otol Neurotol"},{"key":"R177-20241014","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1179\/cim.2008.9.2.70","article-title":"Relationships among objective measures and speech perception in adult users of the HiResolution Bionic Ear.","volume":"9","author":"Wolfe","year":"2008","journal-title":"Cochlear Implants Int"},{"key":"R178-20241014","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3109\/14992020309056084","article-title":"Analysis of programming maps and its application for balancing multichannel cochlear implants.","volume":"42","author":"Sainz","year":"2003","journal-title":"Int J Audiol"},{"key":"R179-20241014","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1001\/archotol.127.8.963","article-title":"Measurement of comfort levels by means of electrical stapedial reflex in children.","volume":"127","author":"Bresnihan","year":"2001","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R180-20241014","doi-asserted-by":"crossref","first-page":"501738","DOI":"10.1155\/2014\/501738","article-title":"Cochlear implant programming: a global survey on the state of the art.","volume":"2014","author":"Vaerenberg","year":"2014","journal-title":"ScientificWorldJournal"},{"key":"R181-20241014","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1097\/AUD.0000000000000405","article-title":"The change in electrical stimulation levels during 24 months postimplantation for a large cohort of adults using the Nucleus\u00ae cochlear implant.","volume":"38","author":"Gajadeera","year":"2017","journal-title":"Ear Hear"},{"key":"R182-20241014","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1097\/AUD.0000000000000466","article-title":"Investigation of electrical stimulation levels over 8 to 10 years postimplantation for a large cohort of adults using cochlear implants.","volume":"38","author":"Gajadeera","year":"2017","journal-title":"Ear Hear"},{"key":"R183-20241014","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1097\/00003446-200112000-00004","article-title":"A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users.","volume":"22","author":"Hughes","year":"2001","journal-title":"Ear Hear"},{"key":"R184-20241014","first-page":"111","article-title":"Longitudinal variations in fitting parameters for adult cochlear implant recipients.","volume":"34","author":"Mosca","year":"2014","journal-title":"Acta Otorhinolaryngol Ital"},{"key":"R185-20241014","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1179\/cim.2006.7.1.15","article-title":"Changes in psychophysical parameters during the first month of programming the nucleus contour and contour advance cochlear implants.","volume":"7","author":"Walravens","year":"2006","journal-title":"Cochlear Implants Int"},{"key":"R186-20241014","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1177\/0194599818764329","article-title":"Minimum reporting standards for adult cochlear implantation.","volume":"159","author":"Adunka","year":"2018","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R187-20241014","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1044\/jshd.2701.62","article-title":"Revised CNC lists for auditory tests.","volume":"27","author":"Peterson","year":"1962","journal-title":"J Speech Hear Disord"},{"key":"R188-20241014","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1097\/AUD.0b013e31822c2549","article-title":"Development and validation of the AzBio sentence lists.","volume":"33","author":"Spahr","year":"2012","journal-title":"Ear Hear"},{"key":"R190-20241014","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1097\/01.mao.0000178150.44505.52","article-title":"Cochlear implant soft failures consensus development conference statement.","volume":"26","author":"Balkany","year":"2005","journal-title":"Otol Neurotol"},{"key":"R191-20241014","doi-asserted-by":"crossref","first-page":"722","DOI":"10.3766\/jaaa.17011","article-title":"Cochlear implant practice patterns: the U.S. trends with pediatric patients.","volume":"29","author":"Hemmingson","year":"2018","journal-title":"J Am Acad Audiol"},{"key":"R192-20241014","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.3109\/00016489.2014.914244","article-title":"Exploring the clinical approach to the bimodal fitting of hearing aids and cochlear implants: results of an international survey.","volume":"134","author":"Scherf","year":"2014","journal-title":"Acta Otolaryngol"},{"key":"R193-20241014","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1044\/2015_AJA-14-0069","article-title":"Bimodal programming: a survey of current clinical practice.","volume":"24","author":"Siburt","year":"2015","journal-title":"Am J Audiol"},{"key":"R198-20241014","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1080\/14670100.2020.1787622","article-title":"Evaluation of a novel bimodal fitting formula in Advanced Bionics cochlear implant recipients.","volume":"21","author":"Warren","year":"2020","journal-title":"Cochlear Implants Int"},{"key":"R199-20241014","article-title":"Reducing the device delay mismatch can improve sound localization in bimodal cochlear implant\/hearing-aid users.","volume":"23","author":"Zirn","year":"2019","journal-title":"Trends Hear"},{"key":"R200-20241014","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1044\/2015_AJA-15-0045","article-title":"Reduction in high-frequency hearing aid gain can improve performance in patients with contralateral cochlear implant: a pilot study.","volume":"24","author":"Messersmith","year":"2015","journal-title":"Am J Audiol"},{"key":"R201-20241014","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.3109\/00016489.2012.677546","article-title":"Contralateral hearing aid use in cochlear implanted patients: multicenter study of bimodal benefit.","volume":"132","author":"Morera","year":"2012","journal-title":"Acta Otolaryngol"},{"key":"R202-20241014","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1097\/AUD.0b013e31828e86e8","article-title":"Effect of hearing aid bandwidth on speech recognition performance of listeners using a cochlear implant and contralateral hearing aid (bimodal hearing).","volume":"34","author":"Neuman","year":"2013","journal-title":"Ear Hear"},{"key":"R203-20241014","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3766\/jaaa.20.6.4","article-title":"Recognition and localization of speech by adult cochlear implant recipients wearing a digital hearing aid in the nonimplanted ear (bimodal hearing).","volume":"20","author":"Potts","year":"2009","journal-title":"J Am Acad Audiol"},{"key":"R204-20241014","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1179\/cim.2007.8.1.29","article-title":"Bimodal benefits of cochlear implant and hearing aid (on the non-implanted ear): a pilot study to develop a protocol and a test battery.","volume":"8","author":"Ullauri","year":"2007","journal-title":"Cochlear Implants Int"},{"key":"R205-20241014","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/AUD.0000000000000638","article-title":"The effect of hearing aid bandwidth and configuration of hearing loss on bimodal speech recognition in cochlear implant users.","volume":"40","author":"Neuman","year":"2019","journal-title":"Ear Hear"},{"key":"R206-20241014","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/AUD.0000000000000032","article-title":"Cochlear dead regions constrain the benefit of combining acoustic stimulation with electric stimulation.","volume":"35","author":"Zhang","year":"2014","journal-title":"Ear Hear"},{"key":"R207-20241014","doi-asserted-by":"crossref","first-page":"205","DOI":"10.3109\/03005364000000131","article-title":"A test for the diagnosis of dead regions in the cochlea.","volume":"34","author":"Moore","year":"2000","journal-title":"Br J Audiol"},{"key":"R208-20241014","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1097\/01.aud.0000145992.31135.89","article-title":"New version of the TEN test with calibrations in dB HL.","volume":"25","author":"Moore","year":"2004","journal-title":"Ear Hear"},{"key":"R209-20241014","doi-asserted-by":"crossref","first-page":"10, 12, 13","DOI":"10.1097\/01.HJ.0000553576.87650.3c","article-title":"Bimodal hearing: how to optimize bimodal fitting.","volume":"72","author":"Gifford","year":"2019","journal-title":"Hear J"},{"key":"R210-20241014","doi-asserted-by":"crossref","first-page":"722","DOI":"10.3766\/jaaa.23.9.6","article-title":"Cochlear implant combined with a linear frequency transposing hearing aid.","volume":"23","author":"Hua","year":"2012","journal-title":"J Am Acad Audiol"},{"key":"R211-20241014","doi-asserted-by":"crossref","first-page":"380","DOI":"10.3766\/jaaa.21.6.3","article-title":"The use of frequency compression by cochlear implant recipients with postoperative acoustic hearing.","volume":"21","author":"McDermott","year":"2010","journal-title":"J Am Acad Audiol"},{"key":"R212-20241014","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/AUD.0b013e31824a3b97","article-title":"Effects of frequency compression hearing aids for unilaterally implanted children with acoustically amplified residual hearing in the nonimplanted ear.","volume":"33","author":"Park","year":"2012","journal-title":"Ear Hear"},{"key":"R213-20241014","doi-asserted-by":"crossref","first-page":"105","DOI":"10.3766\/jaaa.24.2.4","article-title":"The contribution of a frequency-compression hearing aid to contralateral cochlear implant performance.","volume":"24","author":"Perreau","year":"2013","journal-title":"J Am Acad Audiol"},{"key":"R214-20241014","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1080\/14670100.2017.1353762","article-title":"Effect of extreme adaptive frequency compression in bimodal listeners on sound localization and speech perception.","volume":"18","author":"Veugen","year":"2017","journal-title":"Cochlear Implants Int"},{"key":"R215-20241014","doi-asserted-by":"crossref","first-page":"467","DOI":"10.3109\/14992027.2014.996825","article-title":"Predictors of aided speech recognition, with and without frequency compression, in older adults.","volume":"54","author":"Ellis","year":"2015","journal-title":"Int J Audiol"},{"key":"R216-20241014","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1080\/14992020902971349","article-title":"Evaluation of nonlinear frequency compression: clinical outcomes.","volume":"48","author":"Glista","year":"2009","journal-title":"Int J Audiol"},{"key":"R217-20241014","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/AUD.0000000000001109","article-title":"Decoding billing practices in cochlear implant programs.","volume":"43","author":"Hall","year":"2022","journal-title":"Ear Hear"},{"issue":"suppl 2","key":"R218-20241014","first-page":"S17","article-title":"Worldwide trends in bilateral cochlear implantation.","volume":"120","author":"Peters","year":"2010","journal-title":"Laryngoscope"},{"key":"R220-20241014","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1001\/archotol.130.5.648","article-title":"Bilateral cochlear implants in adults and children.","volume":"130","author":"Litovsky","year":"2004","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R221-20241014","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1097\/AUD.0b013e3181a165be","article-title":"Spatial hearing and speech intelligibility in bilateral cochlear implant users.","volume":"30","author":"Litovsky","year":"2009","journal-title":"Ear Hear"},{"key":"R222-20241014","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1159\/000078393","article-title":"Exploring the benefits of bilateral cochlear implants.","volume":"9","author":"van Hoesel","year":"2004","journal-title":"Audiol Neurootol"},{"key":"R223-20241014","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1007\/s00405-011-1733-5","article-title":"Clinical need for a Baha trial in patients with single-sided sensorineural deafness. Analysis of a Baha database of 196 patients.","volume":"269","author":"Desmet","year":"2012","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R224-20241014","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/MAO.0b013e318278540e","article-title":"Quality of life reported by patients with idiopathic sudden sensorineural hearing loss.","volume":"34","author":"Sano","year":"2013","journal-title":"Otol Neurotol"},{"key":"R225-20241014","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1097\/MAO.0b013e3181d27cc0","article-title":"BAHA in single-sided deafness: patient compliance and subjective benefit.","volume":"31","author":"Schr\u00f8der","year":"2010","journal-title":"Otol Neurotol"},{"key":"R226-20241014","doi-asserted-by":"crossref","first-page":"4163","DOI":"10.1523\/JNEUROSCI.0048-04.2004","article-title":"Contribution of head shadow and pinna cues to chronic monaural sound localization.","volume":"24","author":"Van Wanrooij","year":"2004","journal-title":"J Neurosci"},{"key":"R227-20241014","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/MAO.0000000000001269","article-title":"Comparison of speech-in-noise and localization benefits in unilateral hearing loss subjects using contralateral routing of signal hearing aids or bone-anchored implants.","volume":"38","author":"Snapp","year":"2017","journal-title":"Otol Neurotol"},{"key":"R228-20241014","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1097\/MAO.0000000000001614","article-title":"Effectiveness in rehabilitation of current wireless CROS technology in experienced bone-anchored implant users.","volume":"38","author":"Snapp","year":"2017","journal-title":"Otol Neurotol"},{"key":"R229-20241014","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1044\/jshd.3002.121","article-title":"A rehabilitative approach to the problem of unilateral hearing impairment: the contralateral routing of signals CROS.","volume":"30","author":"Harford","year":"1965","journal-title":"J Speech Hear Disord"},{"key":"R230-20241014","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/00129492-200301000-00015","article-title":"Comparison of the bone anchored hearing aid implantable hearing device with contralateral routing of offside signal amplification in the rehabilitation of unilateral deafness.","volume":"24","author":"Niparko","year":"2003","journal-title":"Otol Neurotol"},{"key":"R231-20241014","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1109\/TNSRE.2013.2253333","article-title":"Image-guidance enables new methods for customizing cochlear implant stimulation strategies.","volume":"21","author":"Noble","year":"2013","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"R232-20241014","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1097\/01.AUD.0000130792.43315.97","article-title":"Head shadow, squelch, and summation effects in bilateral users of the MED-EL COMBI 40\/40+ cochlear implant.","volume":"25","author":"Schleich","year":"2004","journal-title":"Ear Hear"},{"key":"R233-20241014","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1097\/AUD.0b013e318257607b","article-title":"Sound localization in noise by normal-hearing listeners and cochlear implant users.","volume":"33","author":"Kerber","year":"2012","journal-title":"Ear Hear"},{"key":"R234-20241014","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1121\/1.1539520","article-title":"Speech perception, localization, and lateralization with bilateral cochlear implants.","volume":"113","author":"van Hoesel","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R235-20241014","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1002\/lary.23367","article-title":"The addition of a contralateral routing of signals microphone to a unilateral cochlear implant system\u2013a prospective study in speech outcomes.","volume":"123","author":"Arora","year":"2013","journal-title":"Laryngoscope"},{"key":"R236-20241014","first-page":"1","article-title":"Current estimates from the National Health Interview Survey, 1996.","author":"Adams","year":"1999","journal-title":"Vital Health Stat 10"},{"key":"R237-20241014","first-page":"886","article-title":"Tinnitus: an epidemiologic study in Iranian population.","volume":"51","author":"Jalessi","year":"2013","journal-title":"Acta Med Iran"},{"key":"R238-20241014","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1159\/000306630","article-title":"Epidemiological study of chronic tinnitus in Assiut, Egypt.","volume":"35","author":"Khedr","year":"2010","journal-title":"Neuroepidemiology"},{"key":"R239-20241014","first-page":"10","article-title":"the prevalence of tinnitus in the United States and the self-reported efficacy of various treatments.","volume":"18","author":"KochKin","year":"2011","journal-title":"Hear Rev"},{"key":"R240-20241014","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1055\/s-0040-1715975","article-title":"Prevalence and 5-year incidence of tinnitus among older adults: the epidemiology of hearing loss study.","volume":"13","author":"Nondahl","year":"2002","journal-title":"J Am Acad Audiol"},{"key":"R241-20241014","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1111\/coa.12232","article-title":"Prevalence and risk factors of tinnitus: the Korean National Health and Nutrition Examination Survey 2010-2011, a cross-sectional study.","volume":"39","author":"Park","year":"2014","journal-title":"Clin Otolaryngol"},{"key":"R242-20241014","first-page":"9","article-title":"Epidemiology of hearing problems among adults in Italy.","volume":"42","author":"Quaranta","year":"1996","journal-title":"Scand Audiol Suppl"},{"key":"R243-20241014","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.amjmed.2010.02.015","article-title":"Prevalence and characteristics of tinnitus among US adults.","volume":"123","author":"Shargorodsky","year":"2010","journal-title":"Am J Med"},{"key":"R244-20241014","doi-asserted-by":"crossref","first-page":"289","DOI":"10.3109\/14992020309078348","article-title":"Prevalence and characteristics of tinnitus in older adults: the Blue Mountains Hearing Study.","volume":"42","author":"Sindhusake","year":"2003","journal-title":"Int J Audiol"},{"key":"R245-20241014","doi-asserted-by":"crossref","first-page":"115","DOI":"10.3766\/jaaa.23.2.6","article-title":"Patient preferences and willingness to pay for tinnitus treatments.","volume":"23","author":"Tyler","year":"2012","journal-title":"J Am Acad Audiol"},{"issue":"suppl 27","key":"R246-20241014","first-page":"1","article-title":"Cochlear implants.","volume":"85(","author":"House","year":"1976","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R247-20241014","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S0079-6123(07)66033-6","article-title":"Cochlear implants and tinnitus.","volume":"166","author":"Baguley","year":"2007","journal-title":"Prog Brain Res"},{"key":"R248-20241014","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1007\/s00405-007-0352-7","article-title":"Tinnitus modifications after cochlear implantation.","volume":"264","author":"Di Nardo","year":"2007","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R249-20241014","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1080\/14992020400050033","article-title":"Tinnitus and cochlear implantation.","volume":"43","author":"Quaranta","year":"2004","journal-title":"Int J Audiol"},{"key":"R250-20241014","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1080\/00016480701387173","article-title":"The effect of unilateral multichannel cochlear implant on bilaterally perceived tinnitus.","volume":"128","author":"Quaranta","year":"2008","journal-title":"Acta Otolaryngol"},{"key":"R251-20241014","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1097\/MAO.0000000000003172","article-title":"The effect of cochlear implantation on tinnitus and quality of life: a systematic review and meta-analysis.","volume":"42","author":"Yuen","year":"2021","journal-title":"Otol Neurotol"},{"key":"R252-20241014","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1159\/000171478","article-title":"Binaural hearing after cochlear implantation in subjects with unilateral sensorineural deafness and tinnitus.","volume":"14","author":"Vermeire","year":"2009","journal-title":"Audiol Neurootol"},{"key":"R253-20241014","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1080\/14670100.2016.1176778","article-title":"Cochlear implantation in recipients with single-sided deafness: audiological performance.","volume":"17","author":"Hoth","year":"2016","journal-title":"Cochlear Implants Int"},{"key":"R254-20241014","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1177\/000348940411301111","article-title":"Cochlear implants and health status: a comparison with other hearing-impaired patients.","volume":"113","author":"Mo","year":"2004","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R255-20241014","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/j.otc.2015.07.009","article-title":"On the Horizon: cochlear implant technology.","volume":"48","author":"Roche","year":"2015","journal-title":"Otolaryngol Clin North Am"},{"key":"R256-20241014","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1002\/lary.25451","article-title":"United States multicenter clinical trial of the cochlear nucleus hybrid implant system.","volume":"126","author":"Roland","year":"2016","journal-title":"Laryngoscope"},{"key":"R257-20241014","first-page":"128","article-title":"A unilateral cochlear implant for tinnitus.","volume":"22","author":"Elg","year":"2018","journal-title":"Int Tinnitus J"},{"key":"R258-20241014","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1097\/MAO.0b013e3181e3d353","article-title":"Cochlear implantation in unilateral deaf subjects associated with ipsilateral tinnitus.","volume":"31","author":"Buechner","year":"2010","journal-title":"Otol Neurotol"},{"key":"R259-20241014","doi-asserted-by":"crossref","first-page":"1681","DOI":"10.1097\/MAO.0000000000000102","article-title":"Outcomes after cochlear implantation for patients with single-sided deafness, including those with recalcitrant M\u00e9ni\u00e8re\u2019s disease.","volume":"34","author":"Hansen","year":"2013","journal-title":"Otol Neurotol"},{"key":"R260-20241014","doi-asserted-by":"crossref","first-page":"7462","DOI":"10.1186\/1757-1626-2-7462","article-title":"Curing tinnitus with a Cochlear Implant in a patient with unilateral sudden deafness: a case report.","volume":"2","author":"Kleinjung","year":"2009","journal-title":"Cases J"},{"key":"R261-20241014","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.1002\/lary.28358","article-title":"Long-term audiologic outcomes after cochlear implantation for single-sided deafness.","volume":"130","author":"Sullivan","year":"2020","journal-title":"Laryngoscope"},{"key":"R262-20241014","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1177\/000348940811700903","article-title":"Incapacitating unilateral tinnitus in single-sided deafness treated by cochlear implantation.","volume":"117","author":"Van de Heyning","year":"2008","journal-title":"Ann Otol Rhinol Laryngol"},{"issue":"suppl 1","key":"R263-20241014","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1159\/000095616","article-title":"Acoustic plus electric speech processing: preliminary results of a multicenter clinical trial of the Iowa\/Nucleus Hybrid implant.","volume":"11","author":"Gantz","year":"2006","journal-title":"Audiol Neurootol"},{"key":"R264-20241014","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1044\/jshd.4802.150","article-title":"Difficulties experienced by tinnitus sufferers.","volume":"48","author":"Tyler","year":"1983","journal-title":"J Speech Hear Disord"},{"key":"R265-20241014","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1055\/s-0028-1095892","article-title":"Electrical stimulation of the cochlea to reduce tinnitus.","volume":"29","author":"Tyler","year":"2008","journal-title":"Semin Hear"},{"key":"R266-20241014","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1001\/archotol.128.10.1145","article-title":"Payment under public and private insurance and access to cochlear implants.","volume":"128","author":"Garber","year":"2002","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R267-20241014","doi-asserted-by":"crossref","first-page":"e12","DOI":"10.1097\/MAO.0000000000001632","article-title":"Survey of the American Neurotology Society on Cochlear Implantation: part 1, Candidacy Assessment and Expanding Indications.","volume":"39","author":"Carlson","year":"2018","journal-title":"Otol Neurotol"},{"key":"R268-20241014","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1080\/14992020500060404","article-title":"The efficacy of a structured group therapy intervention in improving communication and coping skills for adult cochlear implant recipients.","volume":"44","author":"Heydebrand","year":"2005","journal-title":"Int J Audiol"},{"key":"R269-20241014","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/01.HJ.0000464224.74169.ae","article-title":"Aural rehabilitation builds up patients\u2019 communication skills.","volume":"68","author":"Sweetow","year":"2015","journal-title":"Hear J"},{"key":"R270-20241014","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1159\/000343189","article-title":"Factors affecting auditory performance of postlinguistically deaf adults using cochlear implants: an update with 2251 patients.","volume":"18","author":"Blamey","year":"2013","journal-title":"Audiol Neurootol"},{"key":"R271-20241014","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1055\/s-0035-1564460","article-title":"Optimizing performance in adult cochlear implant users through clinician directed auditory training.","volume":"36","author":"Plant","year":"2015","journal-title":"Semin Hear"},{"key":"R272-20241014","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2174\/1874428101004010047","article-title":"Quality of life measurements after cochlear implantation.","volume":"4","author":"Loeffler","year":"2010","journal-title":"Open Otorhinolaryngol J"},{"key":"R273-20241014","doi-asserted-by":"crossref","first-page":"e130","DOI":"10.1097\/MAO.0000000000002873","article-title":"Role of preoperative patient expectations in adult cochlear implant outcomes.","volume":"42","author":"McRackan","year":"2021","journal-title":"Otol Neurotol"},{"key":"R274-20241014","doi-asserted-by":"crossref","first-page":"190","DOI":"10.3109\/14992027.2014.969409","article-title":"Computer-based auditory phoneme discrimination training improves speech recognition in noise in experienced adult cochlear implant listeners.","volume":"54","author":"Schumann","year":"2015","journal-title":"Int J Audiol"},{"key":"R275-20241014","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1097\/AUD.0b013e31820fc821","article-title":"Digit training in noise can improve cochlear implant users\u2019 speech understanding in noise.","volume":"32","author":"Oba","year":"2011","journal-title":"Ear Hear"},{"key":"R276-20241014","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1044\/1092-4388(2012\/11-0291)","article-title":"The effects of short-term computerized speech-in-noise training on postlingually deafened adult cochlear implant recipients.","volume":"56","author":"Ingvalson","year":"2013","journal-title":"J Speech Lang Hear Res"},{"key":"R277-20241014","article-title":"Computer-based connected-text training of speech-in-noise perception for cochlear implant users.","volume":"23","author":"Green","year":"2019","journal-title":"Trends Hear"},{"key":"R278-20241014","doi-asserted-by":"crossref","first-page":"556","DOI":"10.3389\/fpsyg.2015.00556","article-title":"Auditory training can improve working memory, attention, and communication in adverse conditions for adults with hearing loss.","volume":"6","author":"Ferguson","year":"2015","journal-title":"Front Psychol"},{"key":"R279-20241014","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1590\/2317-1782\/20152013062","article-title":"Munich music questionnaire: adaptation into Brazilian Portuguese and application in cochlear implant users.","volume":"27","author":"Frederigue-Lopes","year":"2015","journal-title":"Codas"},{"key":"R280-20241014","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1682\/JRRD.2007.08.0118","article-title":"Music perception in cochlear implant users and its relationship with psychophysical capabilities.","volume":"45","author":"Drennan","year":"2008","journal-title":"J Rehabil Res Dev"},{"key":"R281-20241014","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1044\/2017_AJA-16-0120","article-title":"A music-related quality of life measure to guide music rehabilitation for adult cochlear implant users.","volume":"26","author":"Dritsakis","year":"2017","journal-title":"Am J Audiol"},{"key":"R282-20241014","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1525\/mp.2016.33.4.493","article-title":"Evaluation of an interactive music awareness program for cochlear implant recipients.","volume":"33","author":"van Besouw","year":"2016","journal-title":"Music Percept"},{"key":"R283-20241014","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1037\/a0021895","article-title":"The relation between instrumental musical activity and cognitive aging.","volume":"25","author":"Hanna-Pladdy","year":"2011","journal-title":"Neuropsychology"},{"key":"R284-20241014","doi-asserted-by":"crossref","first-page":"e18082","DOI":"10.1371\/journal.pone.0018082","article-title":"Musical experience and the aging auditory system: implications for cognitive abilities and hearing speech in noise.","volume":"6","author":"Parbery-Clark","year":"2011","journal-title":"PLoS One"}],"container-title":["Otology &amp; Neurotology Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ONO.0000000000000011","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,15]],"date-time":"2024-10-15T00:11:30Z","timestamp":1728951090000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ONO.0000000000000011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6]]},"references-count":271,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/ono.0000000000000011","relation":{},"ISSN":["2766-3604"],"issn-type":[{"value":"2766-3604","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6]]}}}