{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T02:38:22Z","timestamp":1794019102333,"version":"4.8.0"},"reference-count":37,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2012,4,1]],"date-time":"2012-04-01T00:00:00Z","timestamp":1333238400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2012,4,1]],"date-time":"2012-04-01T00:00:00Z","timestamp":1333238400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2012,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose.<\/jats:title>\n                    <jats:p>This study was designed to compare higher order aberrations of the cornea and of the eye with inferior\u2010superior (I\u2010S) corneal topographic values in keratoconic eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods.<\/jats:title>\n                    <jats:p>We studied 92 eyes from 78 subjects: 21 eyes of 14 subjects with suspected keratoconus, 23 eyes of 16 subjects with manifest keratoconus, and 48 eyes of 48 subjects without keratoconus using the L80 wave+, an instrument which can measure corneal topography and aberrations simultaneously with a large dynamic range making it possible to evaluate higher order aberrations to the seventh order of the Zernike polynomial function series.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results.<\/jats:title>\n                    <jats:p>All ocular and corneal higher order aberrations were found to be significantly higher for keratoconic than normal eyes, but for suspected keratoconus the results were mixed. Corneal aberrations were higher than ocular aberrations due to compensation from the internal aberrations. For manifest keratoconus, the corneal and ocular vertical coma displayed the largest difference being 38.6 and 78.5 times higher, respectively, than normal eyes, while the largest differences for suspected keratoconus were only 5.3 and 4.0 times higher, respectively. On the other hand, inferior\u2010superior dioptric asymmetry was 9.4 and 37.3 times higher for suspected keratoconus and keratoconic eyes, respectively, than normal eyes. The separation of normality curves between suspected keratoconus and normal eyes was 28.6% for I\u2010S and 14.3% for both corneal vertical coma and corneal total coma.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions.<\/jats:title>\n                    <jats:p>Although corneal vertical coma and, to a lesser extent, ocular vertical coma were found to be good indicators for the detection of keratoconic eyes, the traditional corneal topographic value such as the inferior\u2010superior dioptric asymmetry remains an important predictor for identifying suspected keratoconus. However, ocular vertical coma and ocular higher order total root mean square also represent a good means of identifying suspected keratoconus.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/opx.0b013e318249d727","type":"journal-article","created":{"date-parts":[[2012,2,4]],"date-time":"2012-02-04T06:09:05Z","timestamp":1328335745000},"page":"411-418","source":"Crossref","is-referenced-by-count":83,"title":["Aberrations and Topography in Normal, Keratoconus\u2010Suspect, and Keratoconic Eyes"],"prefix":"10.1002","volume":"89","author":[{"given":"Ariela","family":"Gordon\u2010Shaag","sequence":"first","affiliation":[{"name":"Department of Optometry and Vision Science Hadassah Academic College Jerusalem Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Millodot","sequence":"additional","affiliation":[{"name":"School of Optometry The Hong Kong Polytechnic University Hong Kong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reut","family":"Ifrah","sequence":"additional","affiliation":[{"name":"Department of Optometry and Vision Science Hadassah Academic College Jerusalem Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Einat","family":"Shneor","sequence":"additional","affiliation":[{"name":"Department of Optometry and Vision Science Hadassah Academic College Jerusalem Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,4,1]]},"reference":[{"key":"e_1_2_11_2_2","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/0039-6257(84)90094-8","article-title":"Keratoconus and related noninflammatory corneal thinning disorders","volume":"28","author":"Krachmer JH","year":"1984","journal-title":"Surv Ophthalmol"},{"key":"e_1_2_11_3_2","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz YS","year":"1998","journal-title":"Surv Ophthalmol"},{"key":"e_1_2_11_4_2","doi-asserted-by":"crossref","first-page":"91","DOI":"10.3109\/09286586.2011.560747","article-title":"Prevalence and associated factors of keratoconus in Jerusalem: a cross\u2010sectional study","volume":"18","author":"Millodot M","year":"2011","journal-title":"Ophthalmic Epidemiol"},{"key":"e_1_2_11_5_2","doi-asserted-by":"crossref","first-page":"507","DOI":"10.3928\/1081-597X-20000901-04","article-title":"Corneal first surface optical aberrations and visual performance","volume":"16","author":"Applegate RA","year":"2000","journal-title":"J Refract Surg"},{"key":"e_1_2_11_6_2","doi-asserted-by":"crossref","first-page":"400","DOI":"10.3928\/1081-597X-19891101-10","article-title":"Computer\u2010assisted corneal topography in keratoconus","volume":"5","author":"Rabinowitz YS","year":"1989","journal-title":"Refract Corneal Surg"},{"key":"e_1_2_11_7_2","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/00003226-199101000-00002","article-title":"Corneal topography of keratoconus","volume":"10","author":"Wilson SE","year":"1991","journal-title":"Cornea"},{"key":"e_1_2_11_8_2","first-page":"1426","article-title":"Computer\u2010assisted corneal topography. High\u2010resolution graphic presentation and analysis of keratoscopy","volume":"25","author":"Klyce SD","year":"1984","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_11_9_2","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/0002-9394(89)90001-9","article-title":"Corneal topography of early keratoconus","volume":"108","author":"Maguire LJ","year":"1989","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_11_10_2","first-page":"2749","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda N","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_11_11_2","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/S0886-3350(99)00195-9","article-title":"KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus","volume":"25","author":"Rabinowitz YS","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_11_12_2","doi-asserted-by":"crossref","first-page":"539","DOI":"10.3928\/1081-597X-20060601-05","article-title":"Corneal higher order aberrations: a method to grade keratoconus","volume":"22","author":"Alio JL","year":"2006","journal-title":"J Refract Surg"},{"key":"e_1_2_11_13_2","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3928\/1081-597X-20020501-09","article-title":"Validation of the estimation of corneal aberrations from videokeratography in keratoconus","volume":"18","author":"Barbero S","year":"2002","journal-title":"J Refract Surg"},{"key":"e_1_2_11_14_2","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.clae.2004.12.001","article-title":"Corneal wavefront aberration measurements to detect keratoconus patients","volume":"28","author":"Gobbe M","year":"2005","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_11_15_2","doi-asserted-by":"crossref","first-page":"774","DOI":"10.3928\/1081-597X-20071001-06","article-title":"Higher order wavefront aberrations and topography in early and suspected keratoconus","volume":"23","author":"Jafri B","year":"2007","journal-title":"J Refract Surg"},{"key":"e_1_2_11_16_2","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/ICL.0b013e3181e52dd1","article-title":"Visual acuity and ocular aberrations with different rigid gas permeable lens fittings in keratoconus","volume":"36","author":"Jinabhai A","year":"2010","journal-title":"Eye Contact Lens"},{"key":"e_1_2_11_17_2","doi-asserted-by":"crossref","first-page":"3062","DOI":"10.1167\/iovs.06-1285","article-title":"Magnitude and orientation of Zernike terms in patients with keratoconus","volume":"48","author":"Kosaki R","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_11_18_2","doi-asserted-by":"crossref","first-page":"825","DOI":"10.3928\/1081-597X-20071001-13","article-title":"Evaluation of higher order ocular aberrations in patients with keratoconus","volume":"23","author":"Lim L","year":"2007","journal-title":"J Refract Surg"},{"key":"e_1_2_11_19_2","doi-asserted-by":"crossref","first-page":"1996","DOI":"10.1016\/S0161-6420(02)01279-4","article-title":"Wavefront aberrations measured with Hartmann\u2010Shack sensor in patients with keratoconus","volume":"109","author":"Maeda N","year":"2002","journal-title":"Ophthalmology"},{"key":"e_1_2_11_20_2","doi-asserted-by":"crossref","first-page":"2660","DOI":"10.1167\/iovs.08-2754","article-title":"Higher\u2010order aberrations due to the posterior corneal surface in patients with keratoconus","volume":"50","author":"Nakagawa T","year":"2009","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_11_21_2","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1097\/00006324-199711000-00024","article-title":"Using corneal height maps and polynomial decomposition to determine corneal aberrations","volume":"74","author":"Schwiegerling J","year":"1997","journal-title":"Optom Vis Sci"},{"key":"e_1_2_11_22_2","doi-asserted-by":"crossref","first-page":"S255","DOI":"10.3928\/1081-597X-20030302-18","article-title":"Nidek OPD\u2010scan analysis of normal, keratoconic, and penetrating keratoplasty eyes","volume":"19","author":"Shah S","year":"2003","journal-title":"J Refract Surg"},{"key":"e_1_2_11_23_2","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.ajo.2006.11.030","article-title":"Evaluation of keratoconus in Asians: role of Orbscan II and Tomey TMS\u20102 corneal topography","volume":"143","author":"Lim L","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_11_24_2","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","article-title":"Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology","volume":"31","author":"McAlinden C","year":"2011","journal-title":"Ophthal Physiol Opt"},{"key":"e_1_2_11_25_2","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1111\/j.1444-0938.2011.00644.x","article-title":"Clinical evaluation of the L80 autorefractometer","volume":"95","author":"Shneor E","year":"2012","journal-title":"Clin Exp Optom"},{"key":"e_1_2_11_26_2","volume-title":"Optics of the Human Eye","author":"Atchison DA","year":"2000"},{"key":"e_1_2_11_27_2","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1111\/j.1444-0938.2004.tb03166.x","article-title":"Recent advances in representation of monochromatic aberrations of human eyes","volume":"87","author":"Atchison DA","year":"2004","journal-title":"Clin Exp Optom"},{"key":"e_1_2_11_28_2","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1046\/j.1475-1313.2002.00059.x","article-title":"A statistical model of the aberration structure of normal, well\u2010corrected eyes","volume":"22","author":"Thibos LN","year":"2002","journal-title":"Ophthal Physiol Opt"},{"key":"e_1_2_11_29_2","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.1001\/archophthalmol.2009.205","article-title":"Intraoperative and postoperative effects of corneal collagen cross\u2010linking on progressive keratoconus","volume":"127","author":"Vinciguerra P","year":"2009","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_11_30_2","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3928\/1081-597X-19950901-14","article-title":"Videokeratographic indices to aid in screening for keratoconus","volume":"11","author":"Rabinowitz YS","year":"1995","journal-title":"J Refract Surg"},{"key":"e_1_2_11_31_2","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1016\/j.ophtha.2007.01.008","article-title":"Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high\u2010dynamic range wavefront sensor","volume":"114","author":"Pantanelli S","year":"2007","journal-title":"Ophthalmology"},{"key":"e_1_2_11_32_2","doi-asserted-by":"crossref","first-page":"S951","DOI":"10.3928\/1081597X-20090915-10","article-title":"Total, corneal, and internal ocular optical aberrations in patients with keratoconus","volume":"25","author":"Schlegel Z","year":"2009","journal-title":"J Refract Surg"},{"key":"e_1_2_11_33_2","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1111\/j.1442-9071.2008.01821.x","article-title":"An introduction to understanding elevation\u2010based topography: how elevation data are displayed\u2014a review","volume":"37","author":"Belin MW","year":"2009","journal-title":"Clin Experiment Ophthalmol"},{"key":"e_1_2_11_34_2","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1111\/j.1444-0938.2009.00357.x","article-title":"Pentacam posterior and anterior corneal aberrations in normal and keratoconic eyes","volume":"92","author":"Pinero DP","year":"2009","journal-title":"Clin Exp Optom"},{"key":"e_1_2_11_35_2","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1364\/JOSAA.19.000657","article-title":"Videokeratoscope\u2010line\u2010of\u2010sight misalignment and its effect on measurements of corneal and internal ocular aberrations","volume":"19","author":"Salmon TO","year":"2002","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"e_1_2_11_36_2","doi-asserted-by":"crossref","first-page":"4676","DOI":"10.1167\/iovs.03-0190","article-title":"Zernike polynomial fitting fails to represent all visually significant corneal aberrations","volume":"44","author":"Smolek MK","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_11_37_2","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1016\/j.ajo.2009.06.024","article-title":"Prevalence and associations of keratoconus in rural Maharashtra in central India: the central India eye and medical study","volume":"148","author":"Jonas JB","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_11_38_2","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1136\/bjo.2005.074955","article-title":"Incidence and severity of keratoconus in Asir province, Saudi Arabia","volume":"89","author":"Assiri AA","year":"2005","journal-title":"Br J Ophthalmol"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e318249d727","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/OPX.0b013e318249d727","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e318249d727","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T06:30:03Z","timestamp":1774938603000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/OPX.0b013e318249d727"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,4]]}},"alternative-id":["10.1097\/OPX.0b013e318249d727"],"URL":"https:\/\/doi.org\/10.1097\/opx.0b013e318249d727","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,4]]}}}