{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T08:17:24Z","timestamp":1774945044503,"version":"3.50.1"},"reference-count":9,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2012,6,1]],"date-time":"2012-06-01T00:00:00Z","timestamp":1338508800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2012,6,1]],"date-time":"2012-06-01T00:00:00Z","timestamp":1338508800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2012,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose.<\/jats:title>\n                    <jats:p>To compare ocular biometry [anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL)] using A\u2010scan ultrasonography and optical low\u2010coherence interferometry (OLCI) in the chicken eye.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods.<\/jats:title>\n                    <jats:p>Two\u2010week\u2010old chicks (n = 42) were measured. Bland\u2010Altman plots and repeatability and correlation analyses were calculated for both methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results.<\/jats:title>\n                    <jats:p>There was a high correlation between both methods for ACD (r = 0.6144, p &lt; 0.0001), VCD (r = 0.9595, p &lt; 0.0001), and AL (r = 0.9290, p &lt; 0.0001) but not for LT (r = 0.1604, p = 0.144). Measurements by OLCI were more consistent (smaller coefficients of variation and higher intraclass correlation). Bland\u2010Altman plots showed that ultrasound provided larger values for LT, VCD, and AL but not for ACD [differences between ultrasound and OLCI (mean \u00b1 SD): ACD = \u22120.11 \u00b1 0.12 mm; LT = 0.10 \u00b1 0.09 mm; VCD = 0.25 \u00b1 0.08 mm; AL = 0.50 \u00b1 0.16 mm].<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions.<\/jats:title>\n                    <jats:p>A high correlation between both techniques was found for three of the four parameters (ACD, VCD, and AL). However, as the absolute values were different, both techniques cannot replace each other mainly because (1) one is non\u2010contact and the other contact and can induce a minor indentation of the cornea and (2) each device uses different types of waves that cross the ocular interfaces differently. While consistency and repeatability were better by OLCI, a disadvantage is that, different from humans, it can only be used in anesthetized chicks.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/opx.0b013e318257a255","type":"journal-article","created":{"date-parts":[[2012,5,4]],"date-time":"2012-05-04T04:54:19Z","timestamp":1336107259000},"page":"916-921","source":"Crossref","is-referenced-by-count":17,"title":["Ultrasonography and Optical Low\u2010Coherence Interferometry Compared in the Chicken Eye"],"prefix":"10.1002","volume":"89","author":[{"given":"Alexandra Marcha","family":"Penha","sequence":"first","affiliation":[{"name":"University Eye Hospital Institute for Ophthalmic Research, Section of Neurobiology of the Eye Tuebingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eva","family":"Burkhardt","sequence":"additional","affiliation":[{"name":"University Eye Hospital Institute for Ophthalmic Research, Section of Neurobiology of the Eye Tuebingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Schaeffel","sequence":"additional","affiliation":[{"name":"University Eye Hospital Institute for Ophthalmic Research, Section of Neurobiology of the Eye Tuebingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marita P.","family":"Feldkaemper","sequence":"additional","affiliation":[{"name":"University Eye Hospital Institute for Ophthalmic Research, Section of Neurobiology of the Eye Tuebingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,6,1]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1126\/science.694514","article-title":"Extreme myopia produced by modest change in early visual experience","volume":"201","author":"Wallman J","year":"1978","journal-title":"Science"},{"key":"e_1_2_8_3_2","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/0042-6989(91)90011-S","article-title":"Properties of the feedback loops controlling eye growth and refractive state in the chicken","volume":"31","author":"Schaeffel F","year":"1991","journal-title":"Vision Res"},{"key":"e_1_2_8_4_2","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1016\/0042-6989(87)90027-7","article-title":"Developmental aspects of experimental myopia in chicks: susceptibility, recovery and relation to emmetropization","volume":"27","author":"Wallman J","year":"1987","journal-title":"Vision Res"},{"key":"e_1_2_8_5_2","volume-title":"A\u2010scan Axial Length Measurements: A Handbook for IOL Calculations","author":"Byrne SF","year":"1995"},{"key":"e_1_2_8_6_2","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1136\/jech.40.3.274","article-title":"Comparison of methods of measuring blood pressure","volume":"40","author":"Altman DG","year":"1986","journal-title":"J Epidemiol Community Health"},{"key":"e_1_2_8_7_2","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1136\/bjo.2009.167700","article-title":"Clinical comparison of biometry using the non\u2010contact optical low coherence reflectometer (Lenstar LS 900) and contact ultrasound biometer (Tomey AL\u20103000) in cataract eyes","volume":"94","author":"Tappeiner C","year":"2010","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_8_8_2","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1136\/bjo.2008.156554","article-title":"A new optical low coherence reflectometry device for ocular biometry in cataract patients","volume":"93","author":"Buckhurst PJ","year":"2009","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_8_9_2","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1097\/OPX.0b013e31821cc4d6","article-title":"Lenstar versus ultrasound for ocular biometry in a pediatric population","volume":"88","author":"Gursoy H","year":"2011","journal-title":"Optom Vis Sci"},{"key":"e_1_2_8_10_2","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.jcrs.2008.10.038","article-title":"Comparison of partial coherence interferometry and ultrasound for anterior segment biometry","volume":"35","author":"Lara F","year":"2009","journal-title":"J Cataract Refract Surg"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e318257a255","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/OPX.0b013e318257a255","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e318257a255","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T06:53:49Z","timestamp":1774940029000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/OPX.0b013e318257a255"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6]]},"references-count":9,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,6]]}},"alternative-id":["10.1097\/OPX.0b013e318257a255"],"URL":"https:\/\/doi.org\/10.1097\/opx.0b013e318257a255","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6]]}}}