{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T23:47:45Z","timestamp":1775000865893,"version":"3.50.1"},"reference-count":25,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T00:00:00Z","timestamp":1343779200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T00:00:00Z","timestamp":1343779200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2012,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose.<\/jats:title>\n                    <jats:p>To evaluate the difference in the spherical aberration (SA) induced by an aspheric and a non\u2010aspheric myopic ablation profile with the MEL80 excimer laser (Carl Zeiss Meditec).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods.<\/jats:title>\n                    <jats:p>This was a prospective randomized paired\u2010eye controlled study of 15 patients (30 eyes) who underwent LASIK using the Hansatome microkeratome (160 \u03bcm) (Bausch &amp; Lomb) and the MEL80 using a 6 mm optical zone. For each patient, one eye was treated with an aspheric (Aberration Smart Ablation [ASA]) profile and the other eye was treated with a non\u2010aspheric (Tissue Saving Ablation [TSA]) profile, assigned at random. Patients were measured before and 3 months after LASIK with the wavefront supported custom ablation aberrometer (Carl Zeiss Meditec), and SA was measured with an analysis zone of 3 to 7 mm in 0.5 mm intervals. The area under the curve of SA plotted against analysis zone (RAWS) was calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results.<\/jats:title>\n                    <jats:p>The mean spherical equivalent refraction was \u22122.43 \u00b1 1.53 D for the ASA group and \u22122.54 \u00b1 1.47 D for the TSA group (p = 0.87). There was a statistically significant increase in SA for an analysis zone of 6.0 to 7.0 mm for the ASA group and for an analysis zone of 4.5 to 7.0 mm for the TSA group. At the 6 mm zone, the increase in SA was 0.032 in the ASA group and 0.069 in the TSA group. The induction of SA per diopter was 0.024 \u03bcm\/D in the ASA group and 0.035 \u03bcm\/D in the TSA group. The RAWS parameter increased by 34.8% in the ASA group and 74.4% in the TSA group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions.<\/jats:title>\n                    <jats:p>There was less induction of SA in myopic LASIK with an aspheric ablation profile than with a non\u2010aspheric ablation profile.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/opx.0b013e318263c2b2","type":"journal-article","created":{"date-parts":[[2012,7,6]],"date-time":"2012-07-06T05:15:58Z","timestamp":1341551758000},"page":"1211-1218","source":"Crossref","is-referenced-by-count":12,"title":["Spherical Aberration from Myopic Excimer Laser Ablation for Aspheric and Non\u2010Aspheric Profiles"],"prefix":"10.1002","volume":"89","author":[{"given":"Sabong","family":"Srivannaboon","sequence":"first","affiliation":[{"name":"Department of Ophthalmology Siriraj Hospital, Mahidol University Bangkok Thailand"},{"name":"TRSC International LASIK Center Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dan Z.","family":"Reinstein","sequence":"additional","affiliation":[{"name":"London Vision Clinic London United Kingdom"},{"name":"Department of Ophthalmology Columbia University Medical Center New York"},{"name":"Centre Hospitalier National d'Ophtalmologie Paris France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy J.","family":"Archer","sequence":"additional","affiliation":[{"name":"London Vision Clinic London United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ekktet","family":"Chansue","sequence":"additional","affiliation":[{"name":"TRSC International LASIK Center Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,8,1]]},"reference":[{"key":"e_1_2_10_2_1","first-page":"1396","article-title":"Ocular aberrations before and after myopic corneal refractive surgery: LASIK\u2010induced changes measured with laser ray tracing","volume":"42","author":"Moreno\u2010Barriuso E","year":"2001","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_3_1","doi-asserted-by":"crossref","first-page":"S647","DOI":"10.3928\/1081-597X-20000901-32","article-title":"Longitudinal evaluation of optical aberrations following laser in situ keratomileusis surgery","volume":"16","author":"Hong X","year":"2000","journal-title":"J Refract Surg"},{"key":"e_1_2_10_4_1","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jcrs.2004.10.046","article-title":"Causes of spherical aberration induced by laser refractive surgery","volume":"31","author":"Yoon G","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_10_5_1","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/S0886-3350(99)00011-5","article-title":"Functional vision and corneal changes after laser in situ keratomileusis determined by contrast sensitivity, glare testing, and corneal topography","volume":"25","author":"Holladay JT","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_10_6_1","doi-asserted-by":"crossref","first-page":"65","DOI":"10.3928\/1081-597X-20030101-13","article-title":"Equation for corneal asphericity after corneal refractive surgery","volume":"19","author":"Jim\u00e9nez JR","year":"2003","journal-title":"J Refract Surg"},{"key":"e_1_2_10_7_1","first-page":"1736","article-title":"Determination of corneal asphericity after myopia surgery with the excimer laser: a mathematical model","volume":"42","author":"Gatinel D","year":"2001","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_8_1","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1167\/iovs.03-0753","article-title":"Corneal asphericity change after excimer laser hyperopic surgery: theoretical effects on corneal profiles and corresponding Zernike expansions","volume":"45","author":"Gatinel D","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_9_1","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1016\/S0886-3350(02)01895-3","article-title":"Changes in corneal asphericity after laser in situ keratomileusis","volume":"29","author":"Anera RG","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_10_10_1","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.ohc.2004.02.008","article-title":"Correlation of aberrations with visual acuity and symptoms","volume":"17","author":"Chalita MR","year":"2004","journal-title":"Ophthalmol Clin North Am"},{"key":"e_1_2_10_11_1","volume-title":"Queratomileusis y queratofakia","author":"Barraquer JI","year":"1980"},{"key":"e_1_2_10_12_1","doi-asserted-by":"crossref","first-page":"50","DOI":"10.3928\/1081-597X-19960101-12","article-title":"Effects of ablation diameter, depth, and edge contour on the outcome of photorefractive keratectomy","volume":"12","author":"O'Brart DP","year":"1996","journal-title":"J Refract Surg"},{"key":"e_1_2_10_13_1","doi-asserted-by":"crossref","first-page":"166","DOI":"10.3928\/1081-597X-19930501-04","article-title":"Aspheric photorefractive keratectomy with excimer laser","volume":"9","author":"Seiler T","year":"1993","journal-title":"Refract Corneal Surg"},{"key":"e_1_2_10_14_1","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.jcrs.2004.01.026","article-title":"Wavefront\u2010optimized ablation profiles: theoretical background","volume":"30","author":"Mrochen M","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_10_15_1","doi-asserted-by":"crossref","first-page":"S508","DOI":"10.3928\/1081-597X-20050901-18","article-title":"Wavefront aberration outcomes of LASIK for high myopia and high hyperopia","volume":"21","author":"Pesudovs K","year":"2005","journal-title":"J Refract Surg"},{"key":"e_1_2_10_16_1","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/S0886-3350(02)01844-8","article-title":"Quality of vision after laser in situ keratomileusis: influence of dioptric correction and pupil size on visual function","volume":"29","author":"Lee YC","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_10_17_1","doi-asserted-by":"crossref","first-page":"S535","DOI":"10.3928\/1081-597X-20050901-23","article-title":"A new night vision disturbances parameter and contrast sensitivity as indicators of success in wavefront\u2010guided enhancement","volume":"21","author":"Reinstein DZ","year":"2005","journal-title":"J Refract Surg"},{"key":"e_1_2_10_18_1","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.ohc.2004.03.005","article-title":"Optimized and wavefront guided corneal refractive surgery using the Carl Zeiss Meditec platform: the WASCA aberrometer, CRS\u2010Master, and MEL80 excimer laser","volume":"17","author":"Reinstein DZ","year":"2004","journal-title":"Ophthalmol Clin North Am"},{"key":"e_1_2_10_19_1","first-page":"459","article-title":"Standard graphs for reporting refractive surgery","volume":"16","author":"Waring GO","year":"2000","journal-title":"J Refract Surg"},{"key":"e_1_2_10_20_1","doi-asserted-by":"crossref","first-page":"975","DOI":"10.3928\/1081597X-20091016-01","article-title":"Graphic reporting of outcomes of refractive surgery","volume":"25","author":"Reinstein DZ","year":"2009","journal-title":"J Refract Surg"},{"key":"e_1_2_10_21_1","doi-asserted-by":"crossref","first-page":"S656","DOI":"10.3928\/1081-597X-20000901-35","article-title":"Reference axis selection: subcommittee report of the OSA Working Group to establish standards for measurement and reporting of optical aberrations of the eye","volume":"16","author":"Applegate RA","year":"2000","journal-title":"J Refract Surg"},{"key":"e_1_2_10_22_1","doi-asserted-by":"crossref","first-page":"2805","DOI":"10.1167\/iovs.09-4604","article-title":"The effect of the asphericity of myopic laser ablation profiles on the induction of wavefront aberrations","volume":"51","author":"Buhren J","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_23_1","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1016\/j.jcrs.2011.01.013","article-title":"Visual and refractive outcomes following myopic laser\u2010assisted subepithelial keratectomy with a flying\u2010spot excimer laser","volume":"37","author":"McAlinden C","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_10_24_1","doi-asserted-by":"crossref","first-page":"380","DOI":"10.3928\/1081597X-20101104-01","article-title":"Hyperopic LASEK treatments with mitomycin C using the SCHWIND AMARIS","volume":"27","author":"McAlinden C","year":"2011","journal-title":"J Refract Surg"},{"key":"e_1_2_10_25_1","doi-asserted-by":"crossref","first-page":"5537","DOI":"10.1167\/iovs.10-5341","article-title":"The development of an instrument to measure quality of vision: the Quality of Vision (QoV) questionnaire","volume":"51","author":"McAlinden C","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_26_1","volume-title":"Statistics: Methods and Applications","author":"Lewicki P","year":"2007"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e318263c2b2","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/OPX.0b013e318263c2b2","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e318263c2b2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T09:55:00Z","timestamp":1774950900000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/OPX.0b013e318263c2b2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8]]},"references-count":25,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["10.1097\/OPX.0b013e318263c2b2"],"URL":"https:\/\/doi.org\/10.1097\/opx.0b013e318263c2b2","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,8]]}}}