{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T10:54:43Z","timestamp":1774954483522,"version":"3.50.1"},"reference-count":37,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2012,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high\u2010contrast distance visual acuity, near high\u2010contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and the procedure was repeated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Repeated measures analysis of variance revealed differences in visual acuity and CS (p &lt; 0.001) between groups. Mean binocular distance visual acuity and near visual acuity obtained with multifocal toric CL were \u22120.01 \u00b1 0.03 logMAR and \u22120.04 \u00b1 0.06 logMAR, respectively. The mean distance CS with the multifocal toric CL was within normal limits under photopic and mesopic conditions. Under photopic conditions, distant CS was better with distance CL than with multifocal toric CL only at 18 cycles\/degree. Under mesopic conditions without and with glare, there were differences between both CLs in distant CS for all spatial frequencies. There were differences between the two CLs in near CS for all spatial frequencies. Mean values of stereopsis obtained with multifocal toric CLs and with the DCL combined with reading glasses were 62 \u00b1 12 sec of arc and 59 \u00b1 12 sec of arc, respectively (p = 0.06). Near range of clear vision with the multifocal toric CLs was 1.55 \u00b1 0.33D.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The results of this study suggest that the multifocal toric CL studied is a good option to compensate both presbyopia and astigmatism, providing an optimal distance and near visual quality without compromising the stereopsis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/opx.0b013e31826b0934","type":"journal-article","created":{"date-parts":[[2012,10,3]],"date-time":"2012-10-03T15:47:37Z","timestamp":1349279257000},"page":"1627-1635","source":"Crossref","is-referenced-by-count":14,"title":["Visual Performance of a Multifocal Toric Soft Contact Lens"],"prefix":"10.1002","volume":"89","author":[{"given":"David","family":"Madrid\u2010Costa","sequence":"first","affiliation":[{"name":"Optometry Research Group, Department of Optics University of Valencia Valencia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elena","family":"Tom\u00e1s","sequence":"additional","affiliation":[{"name":"Optometry Research Group, Department of Optics University of Valencia Valencia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teresa","family":"Ferrer\u2010Blasco","sequence":"additional","affiliation":[{"name":"Optometry Research Group, Department of Optics University of Valencia Valencia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santiago","family":"Garc\u00eda\u2010L\u00e1zaro","sequence":"additional","affiliation":[{"name":"Optometry Research Group, Department of Optics University of Valencia Valencia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Mont\u00e9s\u2010Mic\u00f3","sequence":"additional","affiliation":[{"name":"Optometry Research Group, Department of Optics University of Valencia Valencia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,11,1]]},"reference":[{"key":"e_1_2_7_2_1","volume-title":"World Population Ageing 2009","author":"United Nations Department of Economic and Social Affairs\/Population Division","year":"2009"},{"key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1111\/j.1444-0938.2010.00524.x","article-title":"An international survey of contact lens prescribing for presbyopia","volume":"94","author":"Morgan PB","year":"2011","journal-title":"Clin Exp Optom"},{"key":"e_1_2_7_4_1","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1097\/00006324-199912000-00018","article-title":"Comparison of suppression, stereoacuity, and interocular differences in visual acuity in monovision and acuvue bifocal contact lenses","volume":"76","author":"Kirschen DG","year":"1999","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1097\/01.opx.0000216098.62165.34","article-title":"Comparison of multifocal and monovision soft contact lens corrections in patients with low\u2010astigmatic presbyopia","volume":"83","author":"Richdale K","year":"2006","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_6_1","doi-asserted-by":"crossref","first-page":"E98","DOI":"10.1097\/OPX.0b013e318194eb18","article-title":"Visual comparison of multifocal contact lens to monovision","volume":"86","author":"Gupta N","year":"2009","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1097\/OPX.0b013e3181eb98b9","article-title":"Stereoacuity with simultaneous vision multifocal contact lenses","volume":"87","author":"Ferrer\u2010Blasco T","year":"2010","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_8_1","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1111\/j.1444-0938.2010.00530.x","article-title":"Stereoacuity with balanced presbyopic contact lenses","volume":"94","author":"Ferrer\u2010Blasco T","year":"2011","journal-title":"Clin Exp Optom"},{"key":"e_1_2_7_9_1","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/ICL.0b013e318185d271","article-title":"Visual acuity and \u201cbalanced progressive\u201d simultaneous vision multifocal contact lenses","volume":"34","author":"Sanders E","year":"2008","journal-title":"Eye Contact Lens"},{"key":"e_1_2_7_10_1","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1097\/OPX.0b013e31820ea1ea","article-title":"Fluctuation in visual acuity during soft toric contact lens wear","volume":"88","author":"Chamberlain P","year":"2011","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1111\/j.1444-0938.2002.tb03033.x","article-title":"Comparative clinical performance of two silicone hydrogel contact lenses for continuous wear","volume":"85","author":"Morgan PB","year":"2002","journal-title":"Clin Exp Optom"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.clae.2007.02.005","article-title":"Is randomisation necessary for measuring defocus curves in pre\u2010presbyopes?","volume":"30","author":"Gupta N","year":"2007","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_7_13_1","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0892-8967(00)00029-8","article-title":"Evaluation of two new soft contact lenses for correction of presbyopia: the Focus Progressives multifocal and the Acuvue Bifocal","volume":"26","author":"Fisher K","year":"2000","journal-title":"Int Contact Lens Clin"},{"key":"e_1_2_7_14_1","first-page":"88","article-title":"Visual performance of a multi\u2010zone bifocal and a progressive multifocal contact lens","volume":"28","author":"Guillon M","year":"2002","journal-title":"CLAO J"},{"key":"e_1_2_7_15_1","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1111\/j.1444-0938.2010.00518.x","article-title":"Visual and optical performance with hybrid multifocal intraocular lenses","volume":"93","author":"Madrid\u2010Costa D","year":"2010","journal-title":"Clin Exp Optom"},{"key":"e_1_2_7_16_1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/S0161-6420(03)00862-5","article-title":"Visual performance with multifocal intraocular lenses: mesopic contrast sensitivity under distance and near conditions","volume":"111","author":"Mont\u00e9s\u2010Mic\u00f3 R","year":"2004","journal-title":"Ophthalmology"},{"key":"e_1_2_7_17_1","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1016\/j.jcrs.2007.03.034","article-title":"Prospective visual evaluation of apodized diffractive intraocular lenses","volume":"33","author":"Alfonso JF","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_18_1","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.ajo.2005.12.031","article-title":"Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial","volume":"141","author":"Souza CE","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_7_19_1","doi-asserted-by":"crossref","first-page":"2043","DOI":"10.1016\/j.jcrs.2008.06.046","article-title":"Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes","volume":"34","author":"Ferrer\u2010Blasco T","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_20_1","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.jcrs.2009.01.014","article-title":"Visual function after implantation of an aspheric bifocal intraocular lens","volume":"35","author":"Alfonso JF","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_21_1","doi-asserted-by":"crossref","first-page":"265","DOI":"10.3928\/1081597X-20080301-08","article-title":"Visual function and change in quality of life after bilateral refractive lens exchange with the ReSTOR multifocal intraocular lens","volume":"24","author":"Blaylock JF","year":"2008","journal-title":"J Refract Surg"},{"key":"e_1_2_7_22_1","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1016\/j.jcrs.2006.04.015","article-title":"ReSTOR intraocular lens implantation in cataract surgery: quality of vision","volume":"32","author":"Chiam PJ","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_23_1","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.jcrs.2007.03.052","article-title":"Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses","volume":"33","author":"Vingolo EM","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_24_1","doi-asserted-by":"crossref","first-page":"2070","DOI":"10.1016\/j.jcrs.2009.07.010","article-title":"Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power","volume":"35","author":"Hayashi K","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_25_1","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1136\/bjo.2008.146647","article-title":"Clinical outcomes and functional visual performance: comparison of the ReSTOR apodised diffractive intraocular lens to a monofocal control","volume":"93","author":"Cionni RJ","year":"2009","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_7_26_1","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1177\/112067211002000111","article-title":"Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes","volume":"20","author":"Fern\u00e1ndez\u2010Vega L","year":"2010","journal-title":"Eur J Ophthalmol"},{"key":"e_1_2_7_27_1","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/j.ajo.2009.02.036","article-title":"Visual and refractive outcomes in hyperopic pseudophakic patients implanted with the Acri.LISA 366D multifocal intraocular lens","volume":"148","author":"Fernandez\u2010Vega L","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_7_28_1","doi-asserted-by":"crossref","first-page":"646","DOI":"10.3928\/1081-597X-20011101-03","article-title":"Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery","volume":"17","author":"Mont\u00e9s\u2010Mic\u00f3 R","year":"2001","journal-title":"J Refract Surg"},{"key":"e_1_2_7_29_1","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.1007\/s00417-007-0662-x","article-title":"Measuring contrast sensitivity in normal subjects with OPTEC 6500: influence of age and glare","volume":"245","author":"Hohberger B","year":"2007","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"e_1_2_7_30_1","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1364\/JOSA.57.001082","article-title":"Spatiotemporal modulation transfer in the human eye","volume":"57","author":"Nes FL","year":"1967","journal-title":"J Opt Soc Am"},{"key":"e_1_2_7_31_1","first-page":"295","volume-title":"The Pupil: Anatomy, Physiology, and Clinical Applications","author":"Loewenfeld IE","year":"1993"},{"key":"e_1_2_7_32_1","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1111\/j.1475-1313.1990.tb00972.x","article-title":"Topology of the near response triad","volume":"10","author":"Myers GA","year":"1990","journal-title":"Ophthalmic Physiol Opt"},{"key":"e_1_2_7_33_1","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.1097\/OPX.0b013e31822be35a","article-title":"Changes in accommodative responses with multifocal contact lenses: a pilot study","volume":"88","author":"Madrid\u2010Costa D","year":"2011","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_34_1","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/j.jcrs.2008.04.031","article-title":"Optimizing measurement of subjective amplitude of accommodation with defocus curves","volume":"34","author":"Gupta N","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_35_1","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1097\/00006324-199107000-00005","article-title":"Task and visual performance with concentric bifocal contact lenses","volume":"68","author":"Sheedy JE","year":"1991","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_36_1","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1097\/00006324-199206000-00011","article-title":"Comparative visual performance of three presbyopic contact lens corrections","volume":"69","author":"Back A","year":"1992","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_37_1","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.clae.2006.12.006","article-title":"An exploration of modified monovision with diffractive bifocal contact lenses","volume":"30","author":"Freeman MH","year":"2007","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_7_38_1","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/ICL.0b013e3181b5003b","article-title":"Early symptomatic presbyopes\u2014what correction modality works best?","volume":"35","author":"Woods J","year":"2009","journal-title":"Eye Contact Lens"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e31826b0934","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/OPX.0b013e31826b0934","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e31826b0934","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T09:58:26Z","timestamp":1774951106000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/OPX.0b013e31826b0934"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11]]},"references-count":37,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["10.1097\/OPX.0b013e31826b0934"],"URL":"https:\/\/doi.org\/10.1097\/opx.0b013e31826b0934","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,11]]}}}