{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T19:40:22Z","timestamp":1785354022847,"version":"3.55.0"},"reference-count":24,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2013,3,1]],"date-time":"2013-03-01T00:00:00Z","timestamp":1362096000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2013,3,1]],"date-time":"2013-03-01T00:00:00Z","timestamp":1362096000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/100007489","name":"Bausch and Lomb","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007489","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2013,3]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate changes in the shape of the posterior cornea at the end of the day based on anterior corneal topography and corneal thickness during myopic overnight orthokeratology (OK) over 14 nights' wear of reverse geometry gas\u2010permeable (GP) contact lenses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Eighteen subjects (aged 19 to 32 years) with low myopia and astigmatism were fitted with reverse geometry lenses (BE; Capricornia Contact Lens Pty Ltd) for myopic OK, which were worn overnight only for a 14\u2010day period. A separate group of 10 subjects (aged 19 to 32 years) with low astigmatism wore J\u2010Contour conventional GP lenses (Capricornia Contact Lens Pty Ltd) for one night. Corneal topography (Medmont E\u2010300) and total corneal thickness (Holden\u2010Payor optical pachometer) across the horizontal meridian were measured at baseline and approximately 8 to 10 hours after lens removal on days 1, 4, 7, and 14 of overnight OK lens wear and after one night of GP lens wear for the control group. Posterior corneal apical radius of curvature and asphericity (\n                      <jats:italic>Q<\/jats:italic>\n                      ) were calculated using an in\u2010house program based on the anterior corneal ellipse curve and corneal thickness.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Myopia reduced from \u22122.64 \u00b1 0.99 diopters (mean \u00b1 SD) to \u22120.39 \u00b1 0.49 diopters during 14 days of overnight OK lens wear. In the OK lens\u2013wearing eyes, there were no statistically significant changes in posterior corneal apical radius of curvature during 14 days of overnight OK. However, there were statistically significant increases in posterior corneal\n                      <jats:italic>Q<\/jats:italic>\n                      on days 4 and 7. In the conventional GP lens\u2013wearing eyes, there were no statistically significant changes in either posterior corneal apical radius or\n                      <jats:italic>Q<\/jats:italic>\n                      after overnight lens wear.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The results of this study support the current hypothesis that the OK refractive effect is achieved primarily through remodeling of the anterior corneal layers, without overall corneal bending.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/opx.0b013e31828121eb","type":"journal-article","created":{"date-parts":[[2013,2,15]],"date-time":"2013-02-15T03:48:10Z","timestamp":1360900090000},"page":"196-204","source":"Crossref","is-referenced-by-count":29,"title":["Posterior Corneal Shape Changes in Myopic Overnight Orthokeratology"],"prefix":"10.1002","volume":"90","author":[{"given":"Jeong Ho","family":"Yoon","sequence":"first","affiliation":[{"name":"School of Optometry University of Choonhae Health Science Ulsan Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helen A.","family":"Swarbrick","sequence":"additional","affiliation":[{"name":"School of Optometry and Vision Science University of New South Wales Sydney New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,3,1]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/S0892-8967(97)00055-2","article-title":"An analysis of the changes in corneal shape and refractive error induced by accelerated orthokeratology","volume":"24","author":"Mountford J","year":"1997","journal-title":"Int Contact Lens Clin"},{"key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1002\/j.1538-9235.2000.tb01088.x","article-title":"Overnight orthokeratology","volume":"77","author":"Nichols JJ","year":"2000","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_4_1","doi-asserted-by":"crossref","first-page":"2518","DOI":"10.1167\/iovs.02-0680","article-title":"The effects of overnight orthokeratology lens wear on corneal thickness","volume":"44","author":"Alharbi A","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_7_5_1","first-page":"598","article-title":"Overnight orthokeratology: preliminary results of the Lenses and Overnight Orthokeratology (LOOK) study","volume":"79","author":"Rah MJ","year":"2002","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_6_1","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/01.ICL.0000072831.13880.A0","article-title":"Overnight orthokeratology: visual and corneal changes","volume":"29","author":"Soni PS","year":"2003","journal-title":"Eye Contact Lens"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/01.opx.0000166772.68413.0e","article-title":"Reduction of myopia from corneal refractive therapy","volume":"82","author":"Sorbara L","year":"2005","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_8_1","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1097\/ICL.0b013e318065b0dd","article-title":"Empirical advanced orthokeratology through corneal topography: the University of Houston clinical study","volume":"33","author":"El Hage S","year":"2007","journal-title":"Eye Contact Lens"},{"key":"e_1_2_7_9_1","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/S0886-3350(88)80063-4","article-title":"Photorefractive keratectomy: a technique for laser refractive surgery","volume":"14","author":"Munnerlyn CR","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_10_1","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/ICL.0b013e3180515299","article-title":"Changes in the anterior and posterior radii of the corneal curvature and anterior chamber depth by orthokeratology","volume":"34","author":"Tsukiyama J","year":"2008","journal-title":"Eye Contact Lens"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1111\/j.1475-1313.2010.00710.x","article-title":"Posterior corneal curvature change and recovery after 6 months of overnight orthokeratology treatment","volume":"30","author":"Chen D","year":"2010","journal-title":"Ophthalmic Physiol Opt"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1097\/01.opx.0000135097.99877.5d","article-title":"Posterior corneal changes with orthokeratology","volume":"81","author":"Owens H","year":"2004","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_13_1","first-page":"223","article-title":"Validating a new approach to quantify posterior corneal curvature in vivo","volume":"17","author":"Yoon JH","year":"2012","journal-title":"J Korean Ophthal Opt Soc"},{"key":"e_1_2_7_14_1","first-page":"175","article-title":"The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting","volume":"79","author":"Cho P","year":"2002","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_15_1","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1111\/j.1475-1313.1989.tb00902.x","article-title":"Theoretical principles of optical pachometry","volume":"9","author":"Brennan NA","year":"1989","journal-title":"Ophthalmic Physiol Opt"},{"key":"e_1_2_7_16_1","first-page":"1001","article-title":"The posterior corneal topography","volume":"32","author":"Rivett AG","year":"1991","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_7_17_1","doi-asserted-by":"crossref","first-page":"1918","DOI":"10.1016\/j.ophtha.2006.05.053","article-title":"Repeatability and reproducibility of posterior corneal curvature measurements by combined scanning\u2010slit and placido\u2010disc topography after LASIK","volume":"113","author":"Maldonado MJ","year":"2006","journal-title":"Ophthalmology"},{"key":"e_1_2_7_18_1","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1111\/j.1444-0938.2008.00336.x","article-title":"Reliability and repeatability of the Pentacam on corneal curvatures","volume":"92","author":"Chen D","year":"2009","journal-title":"Clin Exp Optom"},{"key":"e_1_2_7_19_1","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.jcrs.2008.10.010","article-title":"Intraobserver and interobserver repeatability of curvature and aberrometric measurements of the posterior corneal surface in normal eyes using Scheimpflug photography","volume":"35","author":"Pi\u00f1ero DP","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_7_20_1","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.ajo.2007.05.030","article-title":"Corneal changes and wavefront analysis after orthokeratology fitting test","volume":"144","author":"Stillitano IG","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_7_21_1","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1097\/OPX.0b013e3180437e6e","article-title":"Corneal refractive therapy with different lens materials, part 2: effect of oxygen transmissibility on corneal shape and optical characteristics","volume":"84","author":"Lu F","year":"2007","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_22_1","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.clae.2006.12.001","article-title":"Visual performance after overnight orthokeratology","volume":"30","author":"Johnson KL","year":"2007","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_7_23_1","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/01.ICL.0000146170.27288.A3","article-title":"Empirical versus trial set fitting systems for accelerated orthokeratology","volume":"31","author":"Maldonado\u2010Codina C","year":"2005","journal-title":"Eye Contact Lens"},{"key":"e_1_2_7_24_1","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1097\/00006324-199811000-00019","article-title":"Corneal response to orthokeratology","volume":"75","author":"Swarbrick HA","year":"1998","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_25_1","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/01.ICL.0000140223.60892.16","article-title":"Corneal and epithelial thickness changes after 4 weeks of overnight corneal refractive therapy lens wear, measured with optical coherence tomography","volume":"30","author":"Haque S","year":"2004","journal-title":"Eye Contact Lens"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e31828121eb","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/OPX.0b013e31828121eb","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0b013e31828121eb","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T11:35:40Z","timestamp":1774956940000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/OPX.0b013e31828121eb"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,3]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,3]]}},"alternative-id":["10.1097\/OPX.0b013e31828121eb"],"URL":"https:\/\/doi.org\/10.1097\/opx.0b013e31828121eb","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,3]]}}}