{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T23:35:04Z","timestamp":1780356904777,"version":"3.54.1"},"reference-count":57,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Forensic Med Pathol"],"published-print":{"date-parts":[[2018,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Recent studies have indicated that multiphase postmortem computed tomography angiography (MPMCTA) allows detection of a pathological enhancement of the myocardium in regions that correlate with the localization of the infarction at histology. The aim of this study was to verify this hypothesis by examining MPMCTA images in cases of myocardial infarction. Therefore, we investigated 10 autopsy cases where death was attributed to myocardial infarction or which showed cardiovascular pathology. As a control group, we selected 10 cases of non-natural (namely, not cardiac) death. The MPMCTA was performed in both groups to ascertain whether a pathological enhancement could be observed. We detected a myocardial enhancement in all cardiac death cases, in the same region that showed infarction at histology. No enhancement was observed in control cases. These results have important implications in the routine management of sudden cardiac death cases. In fact, MPMCTA can not only orient about the cause of death before autopsy, but can especially help to identify affected regions for guiding and improving the sampling for microscopic examination.<\/jats:p>","DOI":"10.1097\/paf.0000000000000372","type":"journal-article","created":{"date-parts":[[2018,2,13]],"date-time":"2018-02-13T20:18:10Z","timestamp":1518553090000},"page":"106-113","source":"Crossref","is-referenced-by-count":10,"title":["Visualization of Myocardial Infarction in Postmortem Multiphase Computed Tomography Angiography"],"prefix":"10.1097","volume":"39","author":[{"given":"Sara","family":"Sabatasso","sequence":"first","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Vanhaebost","sequence":"additional","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Doenz","sequence":"additional","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristian","family":"Palmiere","sequence":"additional","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katarzyna","family":"Michaud","sequence":"additional","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrice","family":"Dedouit","sequence":"additional","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silke","family":"Grabherr","sequence":"additional","affiliation":[{"name":"From the *University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland; \u2020Cliniques Universitaires Saint-Luc, Service de M\u00e9decine L\u00e9gale, Brussels, Belgium; and \u2021Centre Hospitalier Universitaire Vaudois (CHUV), Service de Radiologie, Lausanne, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"2","key":"bib1-20231020","first-page":"386","article-title":"Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)-a feasibility study","volume":"48","year":"2003","journal-title":"J Forensic Sci"},{"issue":"1","key":"bib2-20231020","first-page":"29","article-title":"Dilatation of the heart on postmortem computed tomography (PMCT): comparison with live CT","volume":"21","year":"2003","journal-title":"Radiat Med"},{"issue":"1","key":"bib3-20231020","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.forsciint.2003.09.016","article-title":"Non-traumatic postmortem computed tomographic (PMCT) findings of the lung","volume":"139","year":"2004","journal-title":"Forensic Sci Int"},{"key":"bib4-20231020","doi-asserted-by":"crossref","first-page":"1423","DOI":"10.1136\/bmj.324.7351.1423","article-title":"Postmortem examinations using magnetic resonance imaging: four year review of a working service","volume":"324","year":"2002","journal-title":"BMJ"},{"issue":"2","key":"bib5-20231020","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1002\/1522-2586(200102)13:2<277::AID-JMRI1040>3.0.CO;2-W","article-title":"Postmortem whole-body magnetic resonance imaging as an adjunct to autopsy: preliminary clinical experience","volume":"13","year":"2001","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"bib6-20231020","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1097\/00005373-199410000-00006","article-title":"Utility of postmortem computed tomography in trauma victims","volume":"37","year":"1994","journal-title":"J Trauma"},{"issue":"1","key":"bib7-20231020","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.forsciint.2004.05.019","article-title":"Virtopsy: Postmortem imaging of the human heart in situ using MSCT and MRI","volume":"149","year":"2005","journal-title":"Forensic Sci Int"},{"issue":"5","key":"bib8-20231020","first-page":"1175","article-title":"Virtopsy: postmortem minimally invasive angiography using cross section techniques\u2014implementation and preliminary results","volume":"50","year":"2005","journal-title":"J Forensic Sci"},{"issue":"1036","key":"bib9-20231020","doi-asserted-by":"crossref","first-page":"20130488","DOI":"10.1259\/bjr.20130488","article-title":"Advances in post-mortem CT-angiography","volume":"87","year":"2014","journal-title":"Br J Radiol"},{"issue":"1","key":"bib10-20231020","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/00004728-198302000-00024","article-title":"Postmortem computed tomography in a diving fatality","volume":"7","year":"1983","journal-title":"J Comput Assist Tomogr"},{"issue":"5","key":"bib11-20231020","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1148\/rg.265065001","article-title":"VIRTOPSY: minimally invasive, imaging-guided virtual autopsy","volume":"26","year":"2006","journal-title":"Radiographics"},{"issue":"3","key":"bib13-20231020","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1148\/radiol.2503080421","article-title":"Minimally invasive autopsy: an alternative to conventional autopsy?","volume":"250","year":"2009","journal-title":"Radiology"},{"issue":"12","key":"bib14-20231020","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.mpdhp.2010.08.017","article-title":"The role of computed tomography in adult postmortem examinations: an overview","volume":"16","year":"2010","journal-title":"Diagn Histopathol"},{"issue":"12","key":"bib15-20231020","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.mpdhp.2010.08.010","article-title":"An image of sudden death: utility of routine postmortem computed tomography scanning in medico-legal autopsy practice","volume":"16","year":"2010","journal-title":"Diagn Histopathol"},{"issue":"2\u20133","key":"bib16-20231020","first-page":"190","article-title":"Computed tomography as routine in connection with medico-legal autopsies","volume":"171","year":"2007","journal-title":"Forensic Sci Int"},{"issue":"1\u20133","key":"bib17-20231020","first-page":"9","article-title":"Craniocerebral trauma\u2014congruence between post-mortem computed tomography diagnoses and autopsy results: a 2-year retrospective study","volume":"194","year":"2010","journal-title":"Forensic Sci Int"},{"issue":"9811","key":"bib18-20231020","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/S0140-6736(11)61483-9","article-title":"Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study","volume":"379","year":"2012","journal-title":"Lancet"},{"issue":"1\u20133","key":"bib19-20231020","first-page":"3","article-title":"Background and current status of postmortem imaging in Japan: short history of \"Autopsy imaging (Ai)\"","volume":"225","year":"2013","journal-title":"Forensic Sci Int"},{"issue":"5","key":"bib20-20231020","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.legalmed.2012.03.007","article-title":"Diagnosable and non-diagnosable causes of death by postmortem computed tomography: a review of 339 forensic cases","volume":"14","year":"2012","journal-title":"Leg Med (Tokyo)"},{"issue":"1","key":"bib21-20231020","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.legalmed.2012.08.005","article-title":"Detection of coronary thrombosis after multi-phase postmortem CT-angiography","volume":"15","year":"2013","journal-title":"Leg Med (Tokyo)"},{"issue":"5","key":"bib22-20231020","doi-asserted-by":"crossref","first-page":"W515","DOI":"10.2214\/AJR.05.1394","article-title":"Postmortem angiography after vascular perfusion with diesel oil and a lipophilic contrast agent","volume":"187","year":"2006","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"bib23-20231020","doi-asserted-by":"crossref","first-page":"832","DOI":"10.2214\/AJR.06.0787","article-title":"Postmortem angiography: review of former and current methods","volume":"188","year":"2007","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"bib24-20231020","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1111\/j.1556-4029.2008.00673.x","article-title":"Whole body postmortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver","volume":"53","year":"2008","journal-title":"J Forensic Sci"},{"issue":"5","key":"bib25-20231020","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.2214\/AJR.07.3082","article-title":"Postmortem whole-body CT angiography: evaluation of two contrast media solutions","volume":"190","year":"2008","journal-title":"AJR Am J Roentgenol"},{"issue":"7","key":"bib26-20231020","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1002\/jemt.20585","article-title":"Angiofil-mediated visualization of the vascular system by microcomputed tomography: a feasibility study","volume":"71","year":"2008","journal-title":"Microsc Res Tech"},{"issue":"2","key":"bib27-20231020","doi-asserted-by":"crossref","first-page":"345","DOI":"10.2214\/AJR.07.2261","article-title":"Two-step postmortem angiography with a modified heart-lung machine: preliminary results","volume":"190","year":"2008","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"bib28-20231020","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.2214\/AJR.10.4600","article-title":"Postmortem imaging-guided biopsy as an adjuvant to minimally invasive autopsy with CT and postmortem angiography: a feasibility study","volume":"195","year":"2010","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"bib29-20231020","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1111\/j.1556-4029.2011.02037.x","article-title":"Whole body postmortem magnetic resonance angiography","volume":"57","year":"2012","journal-title":"J Forensic Sci"},{"issue":"6","key":"bib30-20231020","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1007\/s00414-010-0526-5","article-title":"Multi-phase post-mortem CT angiography: development of a standardized protocol","volume":"125","year":"2011","journal-title":"Int J Legal Med"},{"issue":"4","key":"bib31-20231020","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s00414-011-0559-4","article-title":"Targeted post-mortem computed tomography cardiac angiography: proof of concept","volume":"125","year":"2011","journal-title":"Int J Legal Med"},{"issue":"7","key":"bib32-20231020","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.crad.2011.01.007","article-title":"Technical report: diagnosis of coronary artery disease using minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography","volume":"66","year":"2011","journal-title":"Clin Radiol"},{"issue":"9","key":"bib33-20231020","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/j.crad.2011.04.005","article-title":"Post-mortem coronary CT angiography: a Leicester perspective","volume":"66","year":"2011","journal-title":"Clin Radiol"},{"issue":"1","key":"bib34-20231020","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1007\/s12024-011-9267-0","article-title":"Targeted cardiac post-mortem computed tomography angiography: a pictorial review","volume":"8","year":"2012","journal-title":"Forensic Sci Med Pathol"},{"issue":"7","key":"bib35-20231020","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1007\/s10554-012-0012-x","article-title":"Evaluation of postmortem MDCT and MDCT-angiography for the investigation of sudden cardiac death related to atherosclerotic coronary artery disease","volume":"28","year":"2012","journal-title":"Int J Cardiovasc Imaging"},{"issue":"2","key":"bib36-20231020","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1007\/s11547-016-0698-2","article-title":"Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry","volume":"122","year":"2017","journal-title":"Radiol Med"},{"issue":"5","key":"bib37-20231020","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1007\/s00414-015-1191-5","article-title":"Pathomorphological and CT-angiographical characteristics of coronary atherosclerotic plaques in cases of sudden cardiac death","volume":"129","year":"2015","journal-title":"Int J Legal Med"},{"issue":"1","key":"bib38-20231020","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/s00414-013-0819-6","article-title":"Postmortem imaging of sudden cardiac death","volume":"128","year":"2014","journal-title":"Int J Legal Med"},{"issue":"12","key":"bib39-20231020","first-page":"1024","article-title":"Myocardial contrast defect associated with thrombotic coronary occlusion: pre-autopsy diagnosis of a cardiac death with post-mortem CT angiography","volume":"16","year":"2015","journal-title":"Korean J Radiol"},{"issue":"4","key":"bib40-20231020","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1007\/s00414-012-0790-7","article-title":"Accuracy of targeted post-mortem computed tomography coronary angiography compared to assessment of serial histological sections","volume":"127","year":"2013","journal-title":"Int J Legal Med"},{"issue":"20","key":"bib41-20231020","doi-asserted-by":"crossref","first-page":"2459","DOI":"10.1093\/eurheartj\/ehl255","article-title":"Postmortem unenhanced magnetic resonance imaging of myocardial infarction in correlation to histological infarction age characterization","volume":"27","year":"2006","journal-title":"Eur Heart J"},{"issue":"7","key":"bib42-20231020","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.jacc.2013.01.089","article-title":"Post-mortem cardiac 3-T magnetic resonance imaging: visualization of sudden cardiac death?","volume":"62","year":"2013","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"bib43-20231020","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.pcad.2008.06.003","article-title":"Epidemiology of sudden cardiac death: clinical and research implications","volume":"51","year":"2008","journal-title":"Prog Cardiovasc Dis"},{"key":"bib44-20231020","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s00428-007-0505-5","article-title":"Guidelines for autopsy investigation of sudden cardiac death","volume":"452","year":"2008","journal-title":"Virchows Arch"},{"issue":"3","key":"bib45-20231020","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1007\/s00414-013-0840-9","article-title":"Multi-phase postmortem CT angiography: recognizing technique-related artefacts and pitfalls","volume":"127","year":"2013","journal-title":"Int J Legal Med"},{"issue":"1","key":"bib46-20231020","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1097\/PAF.0b013e31820c6aa3","article-title":"The forensic radiographer: a new member in the medicolegal team","volume":"33","year":"2012","journal-title":"Am J Forensic Med Pathol"},{"issue":"2","key":"bib47-20231020","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1148\/radiol.11091882","article-title":"Delayed contrast enhancement on MR images of myocardium: past, present, future","volume":"261","year":"2011","journal-title":"Radiology"},{"issue":"3","key":"bib48-20231020","doi-asserted-by":"crossref","first-page":"469","DOI":"10.2214\/ajr.136.3.469","article-title":"In vivo evaluation of experimental myocardial infarcts by ungated computed tomography","volume":"136","year":"1981","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"bib49-20231020","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1097\/RLI.0b013e3181dfda60","article-title":"Dual source dual-energy computed tomography of acute myocardial infarction: correlation with histopathologic findings in a canine model","volume":"45","year":"2010","journal-title":"Invest Radiol"},{"issue":"2","key":"bib50-20231020","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.jcct.2008.10.014","article-title":"Practical tips and tricks in cardiovascular computed tomography: diagnosis of myocardial infarction","volume":"3","year":"2009","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"1","key":"bib51-20231020","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1148\/radiology.213.1.r99se30247","article-title":"Reperfused myocardial infarction as seen with use of necrosis-specific versus standard extracellular MR contrast media in rats","volume":"213","year":"1999","journal-title":"Radiology"},{"issue":"6","key":"bib52-20231020","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1161\/01.CIR.103.6.871","article-title":"Magnetic resonance characterization of the peri-infarction zone of reperfused myocardial infarction with necrosis-specific and extracellular nonspecific contrast media","volume":"103","year":"2001","journal-title":"Circulation"},{"issue":"Suppl 1","key":"bib53-20231020","first-page":"S42","article-title":"Toward necrotic cell fraction measurement by contrast-enhanced MRI of reperfused ischemically injured myocardium","volume":"5","year":"1998","journal-title":"Acad Radiol"},{"issue":"2","key":"bib54-20231020","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1148\/radiology.215.2.r00ma38520","article-title":"Reperfused rat myocardium subjected to various durations of ischemia: estimation of the distribution volume of contrast material with echo-planar MR imaging","volume":"215","year":"2000","journal-title":"Radiology"},{"issue":"3","key":"bib55-20231020","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1148\/radiology.211.3.r99jn41698","article-title":"Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction: comparison with 99mTc-DTPA autoradiography in rats","volume":"211","year":"1999","journal-title":"Radiology"},{"issue":"5","key":"bib56-20231020","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1161\/01.CIR.99.5.690","article-title":"Noninvasive measurements of infarct size after thrombolysis with a necrosis-avid MRI contrast agent","volume":"99","year":"1999","journal-title":"Circulation"},{"issue":"2","key":"bib57-20231020","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1586\/erc.10.180","article-title":"Computed tomography imaging in myocardial infarction","volume":"9","year":"2011","journal-title":"Expert Rev Cardiovasc Ther"},{"issue":"1","key":"bib58-20231020","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.carpath.2009.06.010","article-title":"The metamorphosis of myocardial infarction following coronary recanalization","volume":"19","year":"2010","journal-title":"Cardiovasc Pathol"}],"container-title":["American Journal of Forensic Medicine &amp; Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00000433-201806000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,20]],"date-time":"2023-10-20T10:37:24Z","timestamp":1697798244000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00000433-201806000-00004"}},"subtitle":["A Feasibility Study"],"short-title":[],"issued":{"date-parts":[[2018,6]]},"references-count":57,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/paf.0000000000000372","relation":{},"ISSN":["1533-404X","0195-7910"],"issn-type":[{"value":"1533-404X","type":"electronic"},{"value":"0195-7910","type":"print"}],"subject":[],"published":{"date-parts":[[2018,6]]}}}