{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:39:34Z","timestamp":1793144374183,"version":"4.5.0"},"reference-count":48,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:sec><jats:title>Objectives:<\/jats:title><jats:p>Ultrasound measured optic nerve sheath diameter is a noninvasive, nonirradiating tool for estimating intracranial hypertension. The objective of this systematic review and meta-analysis is summarization of the current evidence for accuracy of ultrasound measured optic nerve sheath diameter in detecting intracranial hypertension in pediatric patients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Data Sources:<\/jats:title><jats:p>Medical subject heading terms were used to search MEDLINE, Embase, Google Scholar, Web of Science, and the Cochrane Library for relevant citations. Publications from January 1, 2000, to June 30, 2019, were included in the search strategy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Selection:<\/jats:title><jats:p>Studies were included if they involved patients less than 18 years, where ultrasound measured optic nerve sheath diameter was compared to conventional, nonophthalmic tests for intracranial hypertension. Studies were excluded if there was insufficient data to compute a sensitivity\/specificity table. Case reports, case series, and manuscripts not published in English were also excluded.<\/jats:p><\/jats:sec><jats:sec><jats:title>Data Extraction:<\/jats:title><jats:p>The initial search returned 573 citations. Of these, 57 were selected for review.<\/jats:p><\/jats:sec><jats:sec><jats:title>Data Synthesis:<\/jats:title><jats:p>Eleven citations were included in the final meta-analysis. A bivariate random-effects meta-analysis was performed, which revealed a pooled sensitivity for ultrasound measured optic nerve sheath diameter of 93% (95% CI, 74\u201399%), a specificity of 74% (95% CI, 52\u201388%), and a diagnostic odds ratio of 39.00 (95% CI, 4.16\u2013365.32). The area under the curve of the hierarchical summary receiver operating characteristic curve was 0.90 (95% CI, 0.87\u20130.93). Subgroup analyses of the test\u2019s performance evaluating new-onset intracranial hypertension and in comparison to invasively measured intracranial pressure were performed. The test performance in these instances was similar to findings in the primary analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>We are unable to identify a threshold value in ultrasound measured optic nerve sheath diameter for the determination of intracranial hypertension in children. Even though the ultrasound measured optic nerve sheath diameter measurement is highly sensitive to the presence of increased intracranial pressure, the test has only moderate specificity. Therefore, other confirmatory methods and further investigation is necessary in the clinical care of children. The technique is likely not sufficiently precise for clinical use in the absence of other confirmatory methods, and further investigation is necessary to determine clinical protocols for its use in children.<\/jats:p><\/jats:sec>","DOI":"10.1097\/pcc.0000000000002453","type":"journal-article","created":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T15:04:29Z","timestamp":1597331069000},"page":"e858-e868","source":"Crossref","is-referenced-by-count":37,"title":["Ultrasonographic Optic Nerve Sheath Diameter Measurement to Detect Intracranial Hypertension in Children With Neurological Injury: A Systematic Review"],"prefix":"10.1097","volume":"21","author":[{"given":"Vidit","family":"Bhargava","sequence":"first","affiliation":[{"name":"Department of Pediatrics, Division of Critical Care Medicine, Stanford University School of Medicine, Stanford, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Tawfik","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Division of Critical Care Medicine, Stanford University School of Medicine, Stanford, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan Jin","family":"Tan","sequence":"additional","affiliation":[{"name":"Department of Epidemiology and Population Health, Stanford University School of Medicine, Stanford, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Trevor","family":"Dunbar","sequence":"additional","affiliation":[{"name":"Arizona College of Osteopathic Medicine, Midwestern University, Glendale, AZ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bereketeab","family":"Haileselassie","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Division of Critical Care Medicine, Stanford University School of Medicine, Stanford, CA."},{"name":"Department of Chemical and Systems Biology, Stanford University School of Medicine, Stanford, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Su","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Division of Critical Care Medicine, McGovern Medical School, Houston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,8,12]]},"reference":[{"key":"R1-20230824","doi-asserted-by":"crossref","first-page":"648","DOI":"10.3171\/jns.1987.67.5.0648","article-title":"Outcome after severe head injury. Relationship to mass lesions, diffuse injury, and ICP course in pediatric and adult patients.","volume":"67","author":"Alberico","year":"1987","journal-title":"J Neurosurg"},{"key":"R2-20230824","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.1007\/s00381-016-3067-5","article-title":"The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children: Part I: Repeatability, observer variability and general analysis.","volume":"32","author":"Padayachy","year":"2016","journal-title":"Childs Nerv Syst"},{"key":"R3-20230824","doi-asserted-by":"crossref","first-page":"N2","DOI":"10.1097\/01.pcc.0000537980.02045.85","article-title":"Abstract P-523: Ultrasonographic optic nerve sheath diameter (ONSD) measurement for raised intracranial pressure in a tertairy care center of a developing country.","volume":"19","author":"Saeed","year":"2018","journal-title":"Pediatr Crit Care Med"},{"key":"R4-20230824","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1055\/s-0031-1273491","article-title":"Measurement of the optic nerve sheath diameter in children: Comparison between transbulbar sonography and magnetic resonance imaging.","volume":"33","author":"Steinborn","year":"2012","journal-title":"Ultraschall Med"},{"key":"R5-20230824","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.jss.2011.03.009","article-title":"Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.","volume":"170","author":"Strumwasser","year":"2011","journal-title":"J Surg Res"},{"key":"R6-20230824","doi-asserted-by":"crossref","first-page":"42063","DOI":"10.1038\/srep42063","article-title":"Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter.","volume":"7","author":"Wang","year":"2017","journal-title":"Sci Rep"},{"key":"R7-20230824","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1038\/pr.2016.165","article-title":"Correlating optic nerve sheath diameter with opening intracranial pressure in pediatric traumatic brain injury.","volume":"81","author":"Young","year":"2017","journal-title":"Pediatr Res"},{"key":"R8-20230824","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/BF01627611","article-title":"The subarachnoid space surrounding the optic nerves. An ultrasound study of the optic nerve sheath.","volume":"18","author":"Hansen","year":"1996","journal-title":"Surg Radiol Anat"},{"key":"R9-20230824","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.pediatrneurol.2015.03.028","article-title":"Novel magnetic resonance imaging findings in children with intracranial hypertension.","volume":"53","author":"Hirfanoglu","year":"2015","journal-title":"Pediatr Neurol"},{"key":"R10-20230824","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: A systematic review and meta-analysis.","volume":"37","author":"Dubourg","year":"2011","journal-title":"Intensive Care Med"},{"key":"R11-20230824","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.7863\/ultra.34.7.1285","article-title":"Sonography of the optic nerve sheath diameter for detection of raised intracranial pressure compared to computed tomography.","volume":"34","author":"Ohle","year":"2015","journal-title":"J Ultrasound Med"},{"key":"R12-20230824","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1007\/s00134-018-5305-7","article-title":"Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: A systematic review and meta-analysis.","volume":"44","author":"Robba","year":"2018","journal-title":"Intensive Care Med"},{"key":"R13-20230824","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s00464-017-5653-3","article-title":"Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: A systematic review and meta-analysis.","volume":"32","author":"Kim","year":"2018","journal-title":"Surg Endosc"},{"key":"R14-20230824","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1177\/0284185118776501","article-title":"Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: A meta-analysis.","volume":"60","author":"Kim","year":"2019","journal-title":"Acta Radiol"},{"key":"R15-20230824","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.resuscitation.2019.03.004","article-title":"Diagnostic performance of optic nerve sheath diameter for predicting neurologic outcome in post-cardiac arrest patients: A systematic review and meta-analysis.","volume":"138","author":"Lee","year":"2019","journal-title":"Resuscitation"},{"key":"R16-20230824","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1089\/ham.2014.1127","article-title":"Ultrasonography of the optic nerve sheath diameter for diagnosis and monitoring of acute mountain sickness: A systematic review.","volume":"16","author":"Lochner","year":"2015","journal-title":"High Alt Med Biol"},{"key":"R17-20230824","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.7863\/ultra.16.05055","article-title":"Inter-rater reliability of sonographic optic nerve sheath diameter measurements by emergency medicine physicians.","volume":"36","author":"Oberfoell","year":"2017","journal-title":"J Ultrasound Med"},{"key":"R18-20230824","doi-asserted-by":"crossref","first-page":"646","DOI":"10.4103\/ijccm.IJCCM_104_18","article-title":"Sonographic measurement of optic nerve sheath diameter: How steep is the learning curve for a novice operator?","volume":"22","author":"Shrestha","year":"2018","journal-title":"Indian J Crit Care Med"},{"key":"R19-20230824","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1007\/s00381-016-3068-4","article-title":"The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children.: Part II: Age-related ONSD cut-off values and patency of the anterior fontanelle.","volume":"32","author":"Padayachy","year":"2016","journal-title":"Childs Nerv Syst"},{"key":"R20-20230824","doi-asserted-by":"crossref","first-page":"A105","DOI":"10.1097\/01.ccm.0000439580.03385.d5","article-title":"436: USEEICP: Ultrasound screening evaluation in the eyes for intracranial pressure.","volume":"41","author":"Godshall","year":"2013","journal-title":"Crit Care Med"},{"key":"R21-20230824","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The cochrane collaboration\u2019s tool for assessing risk of bias in randomised trials.","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"R22-20230824","doi-asserted-by":"crossref","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement.","volume":"6","author":"Moher","year":"2009","journal-title":"PLoS Med"},{"key":"R23-20230824","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies.","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"R24-20230824","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1186\/s13054-018-2236-1","article-title":"The combination of procalcitonin and C-reactive protein or presepsin alone improves the accuracy of diagnosis of neonatal sepsis: A meta-analysis and systematic review.","volume":"22","author":"Ruan","year":"2018","journal-title":"Crit Care"},{"key":"R25-20230824","doi-asserted-by":"crossref","first-page":"e5713","DOI":"10.1097\/MD.0000000000005713","article-title":"Lung ultrasound for the diagnosis of pneumonia in adults: A meta-analysis.","volume":"96","author":"Long","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"R26-20230824","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/j.jclinepi.2005.02.022","article-title":"Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews.","volume":"58","author":"Reitsma","year":"2005","journal-title":"J Clin Epidemiol"},{"key":"R27-20230824","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/s00068-011-0093-6","article-title":"Optic nerve sheath measurement and raised intracranial pressure in paediatric traumatic brain injury.","volume":"38","author":"Agrawal","year":"2012","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R28-20230824","doi-asserted-by":"crossref","first-page":"985","DOI":"10.4269\/ajtmh.2012.11-0459","article-title":"Prevalence of raised intracranial pressure in cerebral malaria detected by optic nerve sheath ultrasound.","volume":"87","author":"Beare","year":"2012","journal-title":"Am J Trop Med Hyg"},{"key":"R29-20230824","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1111\/j.1365-3156.2008.02153.x","article-title":"Detection of raised intracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children.","volume":"13","author":"Beare","year":"2008","journal-title":"Trop Med Int Health"},{"key":"R30-20230824","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1007\/s00381-013-2172-y","article-title":"Bedside optic nerve sheath diameter ultrasound for the evaluation of suspected pediatric ventriculoperitoneal shunt failure in the emergency department.","volume":"29","author":"Hall","year":"2013","journal-title":"Childs Nerv Syst"},{"key":"R31-20230824","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.pediatrneurol.2015.08.009","article-title":"Bedside optic nerve sheath diameter assessment in the identification of increased intracranial pressure in suspected idiopathic intracranial hypertension.","volume":"54","author":"Irazuzta","year":"2016","journal-title":"Pediatr Neurol"},{"key":"R32-20230824","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/s00381-019-04266-1","article-title":"The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - part I: Correlations, age-dependency and cut-off values.","volume":"36","author":"Kerscher","year":"2020","journal-title":"Childs Nerv Syst"},{"key":"R33-20230824","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/j.annemergmed.2008.11.025","article-title":"Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.","volume":"53","author":"Le","year":"2009","journal-title":"Ann Emerg Med"},{"key":"R34-20230824","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1097\/PEC.0000000000001034","article-title":"The use of ultrasound-measured optic nerve sheath diameter to predict ventriculoperitoneal shunt failure in children.","volume":"35","author":"Lin","year":"2019","journal-title":"Pediatr Emerg Care"},{"key":"R35-20230824","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1136\/bjo.86.10.1109","article-title":"Measurement of optic nerve sheath diameter by ultrasound: A means of detecting acute raised intracranial pressure in hydrocephalus.","volume":"86","author":"Newman","year":"2002","journal-title":"Br J Ophthalmol"},{"key":"R36-20230824","first-page":"495","article-title":"Ultrasonographic optic nerve sheath diameter measurement for raised intracranial pressure in a tertiary care centre of a developing country.","volume":"30","author":"Rehman Siddiqui","year":"2018","journal-title":"J Ayub Med Coll Abbottabad"},{"key":"R37-20230824","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1186\/s13059-014-0424-0","article-title":"The Kardashian index: A measure of discrepant social media profile for scientists.","volume":"15","author":"Hall","year":"2014","journal-title":"Genome Biol"},{"key":"R38-20230824","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s00381-008-0713-6","article-title":"Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus.","volume":"25","author":"McAuley","year":"2009","journal-title":"Childs Nerv Syst"},{"key":"R39-20230824","doi-asserted-by":"crossref","first-page":"369","DOI":"10.3174\/ajnr.A5456","article-title":"Optic nerve measurement on MRI in the pediatric population: Normative values and correlations.","volume":"39","author":"Al-Haddad","year":"2018","journal-title":"AJNR Am J Neuroradiol"},{"key":"R40-20230824","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1038\/eye.2016.141","article-title":"Postnatal growth of the human optic nerve.","volume":"30","author":"Bernstein","year":"2016","journal-title":"Eye (Lond)"},{"key":"R41-20230824","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1001\/archopht.1981.03930010655011","article-title":"Development of myelin in human optic nerve and tract. A light and electron microscopic study.","volume":"99","author":"Magoon","year":"1981","journal-title":"Arch Ophthalmol"},{"key":"R42-20230824","doi-asserted-by":"crossref","first-page":"896","DOI":"10.7326\/M19-0812","article-title":"Bedside optic nerve ultrasonography for diagnosing increased intracranial pressure: A systematic review and meta-analysis.","volume":"171","author":"Koziarz","year":"2019","journal-title":"Ann Intern Med"},{"key":"R43-20230824","doi-asserted-by":"crossref","first-page":"e528","DOI":"10.1111\/j.1755-3768.2011.02159.x","article-title":"Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure - an experimental ultrasound study.","volume":"89","author":"Hansen","year":"2011","journal-title":"Acta Ophthalmol"},{"key":"R44-20230824","first-page":"186","article-title":"Resolution in ultrasound imaging.","volume":"11","author":"Ng","year":"2011","journal-title":"BJA Educ"},{"key":"R45-20230824","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1097\/PCC.0b013e3181e8b3ee","article-title":"Intracranial pressure-monitoring systems in children with traumatic brain injury: Combining therapeutic and diagnostic tools.","volume":"12","author":"Exo","year":"2011","journal-title":"Pediatr Crit Care Med"},{"key":"R46-20230824","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1136\/bmj.a117","article-title":"Reasons or excuses for avoiding meta-analysis in forest plots.","volume":"336","author":"Ioannidis","year":"2008","journal-title":"BMJ"},{"key":"R47-20230824","doi-asserted-by":"crossref","first-page":"143","DOI":"10.7863\/jum.2005.24.2.143","article-title":"Sonographic evaluation of optic nerve diameter in children with raised intracranial pressure.","volume":"24","author":"Malayeri","year":"2005","journal-title":"J Ultrasound Med"},{"key":"R48-20230824","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1097\/PEC.0000000000001046","article-title":"Identification of optic nerve swelling using point-of-care ocular ultrasound in children.","volume":"34","author":"Marchese","year":"2018","journal-title":"Pediatr Emerg Care"}],"container-title":["Pediatric Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PCC.0000000000002453","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T18:40:01Z","timestamp":1696531201000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PCC.0000000000002453"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,12]]},"references-count":48,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/pcc.0000000000002453","relation":{},"ISSN":["1529-7535"],"issn-type":[{"value":"1529-7535","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8,12]]}}}