{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T08:33:48Z","timestamp":1748507628720,"version":"3.40.4"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Phlebotomy can account for significant blood loss in post-surgical pediatric cardiac patients. We investigated the effectiveness of a phlebotomy volume display in the electronic medical record (EMR) to decrease laboratory sampling and blood transfusions. Cost analysis was performed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>This is a prospective interrupted time series quality improvement study. Cross-sectional surveys were administered to medical personnel pre- and post-intervention.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>The study was conducted in a 19-bed cardiac ICU (CICU) at a Children\u2019s hospital.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients:<\/jats:title>\n            <jats:p>One hundred nine post-surgical pediatric cardiac patients weighing 10\u2009kg or less with an ICU stay of 30 days or less were included.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>We implemented a phlebotomy volume display in the intake and output section of the EMR along with a calculated maximal phlebotomy volume display based on 3% of patient total blood volume as a reference.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Measurements and Main Results:<\/jats:title>\n            <jats:p>Providers poorly estimated phlebotomy volume regardless of role, practice setting, or years in practice. Only 12% of providers reported the availability of laboratory sampling volume. After implementation of the phlebotomy display, there was a reduction in mean laboratories drawn per patient per day from 9.5 to 2.5 (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.005) and single electrolytes draw per patient over the CICU stay from 6.1 to 1.6 (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.016). After implementation of the reference display, mean phlebotomy volume per patient over the CICU stay decreased from 30.9 to 14.4\u2009mL (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.038). Blood transfusion volume did not decrease. CICU length of stay, intubation time, number of reintubations, and infections rates did not increase. Nearly all CICU personnel supported the use of the display. The financial cost of laboratory studies per patient has a downward trend and decreased for hemoglobin studies and electrolytes per patient after the intervention.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Providers may not readily have access to phlebotomy volume requirements for laboratories, and most estimate phlebotomy volumes inaccurately. A well-designed phlebotomy display in the EMR can reduce laboratory sampling and associated costs in the pediatric CICU without an increase in adverse patient outcomes.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/pcc.0000000000003240","type":"journal-article","created":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T13:01:04Z","timestamp":1682427664000},"page":"e342-e351","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Impact of Phlebotomy Volume Knowledge on Provider Laboratory Ordering and Transfusion Practices in the Pediatric Cardiac ICU"],"prefix":"10.1097","volume":"24","author":[{"given":"Gary A.","family":"LaCroix","sequence":"first","affiliation":[{"name":"Department of Cardiology, University of Nebraska Medical Center, Omaha, NE."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David A.","family":"Danford","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University of Nebraska Medical Center, Omaha, NE."},{"name":"Department of Cardiology, Children\u2019s Hospital & Medical Center, Omaha, NE."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amanda M.","family":"Marshall","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University of Nebraska Medical Center, Omaha, NE."},{"name":"Department of Cardiology, Children\u2019s Hospital & Medical Center, Omaha, NE."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2023,4,25]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1164\/rccm.200711-1637OC","article-title":"Anemia, blood loss, and blood transfusions in North American children in the intensive care unit.","volume":"178","author":"Bateman","year":"2008","journal-title":"Am J Respir Crit Care Med"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.athoracsur.2015.04.033","article-title":"Blood transfusions after pediatric cardiac operations: A North American Multicenter Prospective Study.","volume":"100","author":"Mazine","year":"2015","journal-title":"Ann Thorac Surg"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.pedn.2017.09.007","article-title":"The effect of diagnostic blood loss on anemia and transfusion among postoperative patients with congenital heart disease in a pediatric intensive care unit.","volume":"38","author":"Zhou","year":"2018","journal-title":"J Pediatr Nurs"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.athoracsur.2008.09.079","article-title":"Risks and predictors of blood transfusion in pediatric patients undergoing open heart operations.","volume":"87","author":"Szekely","year":"2009","journal-title":"Ann Thorac Surg"},{"issue":"9S Suppl 1","key":"R5-20250502","doi-asserted-by":"crossref","first-page":"S137","DOI":"10.1097\/PCC.0000000000001603","article-title":"Recommendations on RBC transfusion in infants and children with acquired and congenital heart disease from the pediatric critical care transfusion and anemia expertise initiative.","volume":"19","author":"Cholette","year":"2018","journal-title":"Pediatr Crit Care Med"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1111\/j.1460-9592.2009.02939.x","article-title":"An audit of transfusion of red blood cell units in pediatric anesthesia.","volume":"19","author":"Keung","year":"2009","journal-title":"Pediatric Anesthesia"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1016\/j.athoracsur.2009.08.081","article-title":"Risk factors for surgical site infection after cardiac surgery in children.","volume":"89","author":"Costello","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1097\/PCC.0b013e3181e30d43","article-title":"Blood transfusion is associated with prolonged duration of mechanical ventilation in infants undergoing reparative cardiac surgery.","volume":"12","author":"Kipps","year":"2011","journal-title":"Pediatr Crit Care Med"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1111\/trf.12827","article-title":"Transfusion reactions in pediatric compared with adult patients: A look at rate, reaction type, and associated products.","volume":"55","author":"Oakley","year":"2015","journal-title":"Transfusion"},{"key":"R10-20250502","first-page":"43","article-title":"Unique aspects of red blood cell transfusion in pediatric patients.","volume":"4","author":"Rai","year":"2016","journal-title":"Int J Clin Transfus Med"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"e047","DOI":"10.1097\/pq9.0000000000000047","article-title":"Reducing blood testing in pediatric patients after heart surgery: Proving sustainability.","volume":"2","author":"Bodily","year":"2017","journal-title":"Pediatr Qual Saf"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1213\/ANE.0000000000002504","article-title":"Patient blood management in pediatric cardiac surgery: A review.","volume":"127","author":"Cholette","year":"2018","journal-title":"Anesth Analg"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"71","DOI":"10.14740\/jocmr1997w","article-title":"Implementation of continuous capnography is associated with a decreased utilization of blood gases.","volume":"7","author":"Rowan","year":"2015","journal-title":"J Clin Med Res"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1542\/peds.2016-2480","article-title":"Controlling phlebotomy volume diminishes PICU transfusion: Implementation processes and impact.","volume":"140","author":"Steffen","year":"2017","journal-title":"Pediatrics"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1002\/jhm.2354","article-title":"A multifaceted hospitalist quality improvement intervention: Decreased frequency of common labs.","volume":"10","author":"Corson","year":"2015","journal-title":"J Hosp Med"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1001\/archsurg.2011.103","article-title":"Surgical vampires and rising health care expenditure: Reducing the cost of daily phlebotomy.","volume":"146","author":"Stuebing","year":"2011","journal-title":"Arch Surg"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/S0002-9343(98)00410-0","article-title":"A randomized trial of a computer-based intervention to reduce utilization of redundant laboratory tests.","volume":"106","author":"Bates","year":"1999","journal-title":"Am J Med"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1007\/s12630-016-0793-9","article-title":"Non-essential blood tests in the intensive care unit: A prospective observational study.","volume":"64","author":"Mikhaeil","year":"2017","journal-title":"Can J Anesth\/J Can Anesth"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"46","DOI":"10.2471\/BLT.10.080010","article-title":"Blood sample volumes in child health research: Review of safe limits.","volume":"89","author":"Howie","year":"2011","journal-title":"Bull World Health Organ"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1093\/jamia\/ocx047","article-title":"Asynchronous automated electronic laboratory result notifications: A systematic review.","volume":"24","author":"Slovis","year":"2017","journal-title":"J Am Med Inform Assoc"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1197\/jamia.M1471","article-title":"Some unintended consequences of information technology in health care: The nature of patient care information system-related errors.","volume":"11","author":"Ash","year":"2004","journal-title":"J Am Med Inform Assoc"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.ijmedinf.2017.05.011","article-title":"A systematic review of the effectiveness of interruptive medication prescribing alerts in hospital CPOE systems to change prescriber behavior and improve patient safety.","volume":"105","author":"Page","year":"2017","journal-title":"Int J Med Inform"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1186\/s12911-017-0430-8","article-title":"Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system.","volume":"17","author":"Ancker","year":"2017","journal-title":"BMC Med Inform Decis Mak"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1002\/jhm.2552","article-title":"Multifaceted intervention including education, rounding checklist implementation, cost feedback, and financial incentives reduces inpatient laboratory costs.","volume":"11","author":"Yarbrough","year":"2016","journal-title":"J Hosp Med"}],"container-title":["Pediatric Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PCC.0000000000003240","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T17:15:39Z","timestamp":1746206139000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PCC.0000000000003240"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,25]]},"references-count":24,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/pcc.0000000000003240","relation":{},"ISSN":["1529-7535"],"issn-type":[{"type":"print","value":"1529-7535"}],"subject":[],"published":{"date-parts":[[2023,4,25]]}}}