{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T09:53:43Z","timestamp":1779357223553,"version":"3.51.4"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T00:00:00Z","timestamp":1719446400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>Transcutaneous carbon dioxide (Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub>) monitoring can noninvasively assess ventilation by estimating carbon dioxide (<jats:sc>CO<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub>) levels in the blood. We aimed to evaluate the accuracy of Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> monitoring in critically ill children by comparing it to the partial pressure of arterial carbon dioxide (Pa<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub>). In addition, we sought to determine the variation between Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> and Pa<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> acceptable to clinicians to modify patient care and to determine which patient-level factors may affect the accuracy of Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> measurements.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Retrospective observational cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Single, quaternary care PICU from July 1, 2012, to August 1, 2020.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Included participants were admitted to the PICU and received noninvasive ventilation support (i.e., continuous or bilevel positive airway pressure), conventional mechanical ventilation, or high-frequency oscillatory or percussive ventilation with Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> measurements obtained within 15 minutes of Pa<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> measurement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>None.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Three thousand four hundred seven paired arterial blood gas and Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> measurements were obtained from 264 patients. Bland-Altman analysis revealed a bias of \u20134.4\u2009mm Hg (95% CI, \u201327 to 18.3\u2009mm Hg) for Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> levels against Pa<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> levels on the first measurement pair for each patient, which fell within the acceptable range of \u00b15\u2009mm Hg stated by surveyed clinicians, albeit with wide limits of agreement. The sensitivity and specificity of Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> to diagnose hypercarbia were 93% and 71%, respectively. Vasoactive-Infusion Score (VIS), age, and self-identified Black\/African American race confounded the relationship between Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> with Pa<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> but percent fluid overload, weight-for-age, probe location, and severity of illness were not significantly associated with Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> accuracy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Tc<jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> monitoring may be a useful adjunct to monitor ventilation in children with respiratory failure, but providers must be aware of the limitations to its accuracy.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/pcc.0000000000003564","type":"journal-article","created":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T18:08:57Z","timestamp":1719511737000},"page":"e372-e379","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Accuracy and Interpretation of Transcutaneous Carbon Dioxide Monitoring in Critically Ill Children"],"prefix":"10.1097","volume":"25","author":[{"given":"Leah","family":"Setar","sequence":"first","affiliation":[{"name":"Ann and Robert H. Lurie Children\u2019s Hospital, Chicago, IL."},{"name":"Division of Pediatrics, Northwestern McGaw Medical Center, Chicago, IL."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica G.","family":"Lee","sequence":"additional","affiliation":[{"name":"Ann and Robert H. Lurie Children\u2019s Hospital, Chicago, IL."},{"name":"Division of Pediatrics, Northwestern McGaw Medical Center, Chicago, IL."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L. Nelson","family":"Sanchez-Pinto","sequence":"additional","affiliation":[{"name":"Ann and Robert H. Lurie Children\u2019s Hospital, Chicago, IL."},{"name":"Division of Pediatrics, Northwestern McGaw Medical Center, Chicago, IL."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bria M.","family":"Coates","sequence":"additional","affiliation":[{"name":"Ann and Robert H. Lurie Children\u2019s Hospital, Chicago, IL."},{"name":"Division of Pediatrics, Northwestern McGaw Medical Center, Chicago, IL."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,6,27]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1513\/AnnalsATS.201311-387FR","article-title":"Techniques for the measurement and monitoring of carbon dioxide in the blood.","volume":"11","author":"Huttmann","year":"2014","journal-title":"Ann Am Thorac Soc"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1111\/pan.14208","article-title":"Carbon dioxide monitoring in children-a narrative review of physiology, value, and pitfalls in clinical practice.","volume":"31","author":"Humphreys","year":"2021","journal-title":"Paediatr Anaesth"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1007\/s00431-014-2407-2","article-title":"Transcutaneous PCO2 monitoring in infants hospitalized with viral bronchiolitis.","volume":"174","author":"Gal","year":"2015","journal-title":"Eur J Pediatr"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1177\/0885066605278652","article-title":"Noninvasive monitoring of carbon dioxide in infants and children with congenital heart disease: End-tidal versus transcutaneous techniques.","volume":"20","author":"Wilson","year":"2005","journal-title":"J Intensive Care Med"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"e20183640","DOI":"10.1542\/peds.2018-3640","article-title":"Continuous noninvasive carbon dioxide monitoring in neonates: From theory to standard of care.","volume":"144","author":"Hochwald","year":"2019","journal-title":"Pediatrics"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1378\/chest.07-1173","article-title":"Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation.","volume":"132","author":"Storre","year":"2007","journal-title":"Chest"},{"key":"R7-20250502","first-page":"55","article-title":"Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: End-tidal versus transcutaneous carbon dioxide.","volume":"85","author":"Tobias","year":"1997","journal-title":"Anesth Analg"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1002\/ppul.23319","article-title":"Diagnostic accuracy of capnography during high-frequency ventilation in neonatal intensive care units.","volume":"51","author":"Kugelman","year":"2016","journal-title":"Pediatr Pulmonol"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1097\/00000539-200106000-00015","article-title":"Noninvasive monitoring of carbon dioxide during mechanical ventilation in older children: End-tidal versus transcutaneous techniques.","volume":"92","author":"Berkenbosch","year":"2001","journal-title":"Anesth Analg"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"S48","DOI":"10.1213\/01.ane.0000278642.16117.f8","article-title":"The design, use, and results of transcutaneous carbon dioxide analysis: Current and future directions.","volume":"105","author":"Eberhard","year":"2007","journal-title":"Anesth Analg"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1111\/j.1460-9592.2009.02930.x","article-title":"Transcutaneous carbon dioxide monitoring in infants and children.","volume":"19","author":"Tobias","year":"2009","journal-title":"Paediatr Anaesth"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"201","DOI":"10.4187\/respcare.06209","article-title":"Accuracy of transcutaneous carbon dioxide levels in comparison to arterial carbon dioxide levels in critically ill children.","volume":"64","author":"Bhalla","year":"2019","journal-title":"Respir Care"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s10877-020-00569-w","article-title":"Comparison of arterial CO2 estimation by end-tidal and transcutaneous CO2 measurements in intubated children and variability with subject related factors.","volume":"35","author":"Duyu","year":"2021","journal-title":"J Clin Monit Comput"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"2203","DOI":"10.1097\/01.CCM.0000181734.26070.26","article-title":"Transcutaneous PCO2 monitoring in critically ill adults: Clinical evaluation of a new sensor.","volume":"33","author":"Bendjelid","year":"2005","journal-title":"Crit Care Med"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1111\/j.1460-9592.2008.02661.x","article-title":"Longtime performance and reliability of two different PtcCO2 and SpO2 sensors in neonates.","volume":"18","author":"Bernet","year":"2008","journal-title":"Paediatr Anaesth"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1002\/ppul.21203","article-title":"Accuracy of three transcutaneous carbon dioxide monitors in critically ill children.","volume":"45","author":"Urbano","year":"2010","journal-title":"Pediatr Pulmonol"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"484","DOI":"10.4187\/respcare.03335","article-title":"What is the potential role of transcutaneous carbon dioxide in guiding acute noninvasive ventilation?","volume":"60","author":"van Oppen","year":"2015","journal-title":"Respir Care"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"721","DOI":"10.4187\/respcare.04618","article-title":"Transcutaneous carbon dioxide in the management of noninvasive ventilation.","volume":"61","author":"Akcil","year":"2016","journal-title":"Respir Care"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1513\/AnnalsATS.201701-034FR","article-title":"Estimating arterial partial pressure of carbon dioxide in ventilated patients: How valid are surrogate measures?","volume":"14","author":"Nassar","year":"2017","journal-title":"Ann Am Thorac Soc"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"2660","DOI":"10.1097\/CCM.0000000000001278","article-title":"High-frequency oscillatory ventilation in pediatric acute lung injury: A multicenter international experience.","volume":"43","author":"Rettig","year":"2015","journal-title":"Crit Care Med"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1034\/j.1399-6576.2003.00170.x","article-title":"Comparison of transcutaneous and endtidal CO2-monitoring for rigid bronchoscopy during high-frequency jet ventilation.","volume":"47","author":"Simon","year":"2003","journal-title":"Acta Anaesthesiol Scand"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"90","DOI":"10.4187\/respcare.04212","article-title":"Neonatal transcutaneous carbon dioxide monitoring\u2014effect on clinical management and outcomes.","volume":"61","author":"Mukhopadhyay","year":"2016","journal-title":"Respir Care"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1136\/thoraxjnl-2017-211466","article-title":"Accuracy and precision of transcutaneous carbon dioxide monitoring: A systematic review and meta-analysis.","volume":"74","author":"Conway","year":"2019","journal-title":"Thorax"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1097\/CCM.0000000000005394","article-title":"Disparities in hypoxemia detection by pulse oximetry across self-identified racial groups and associations with clinical outcomes.","volume":"50","author":"Henry","year":"2022","journal-title":"Crit Care Med"},{"key":"R25-20250502","doi-asserted-by":"crossref","first-page":"1951","DOI":"10.1513\/AnnalsATS.202203-270CME","article-title":"Racial disparity in oxygen saturation measurements by pulse oximetry: Evidence and implications.","volume":"19","author":"Jamali","year":"2022","journal-title":"Ann Am Thorac Soc"},{"key":"R26-20250502","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1146\/annurev-med-043021-024004","article-title":"Origins of racial and ethnic bias in pulmonary technologies.","volume":"74","author":"Sjoding","year":"2023","journal-title":"Annu Rev Med"},{"key":"R27-20250502","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.4187\/respcare.02011","article-title":"AARC clinical practice guideline: Transcutaneous monitoring of carbon dioxide and oxygen: 2012.","volume":"57","author":"Restrepo","year":"2012","journal-title":"Respir Care"}],"container-title":["Pediatric Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PCC.0000000000003564","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T17:03:40Z","timestamp":1746205420000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PCC.0000000000003564"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,27]]},"references-count":27,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/pcc.0000000000003564","relation":{},"ISSN":["1529-7535","1947-3893"],"issn-type":[{"value":"1529-7535","type":"print"},{"value":"1947-3893","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,27]]}}}