{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:12:58Z","timestamp":1786119178986,"version":"build-2736575974"},"reference-count":36,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>Minimally invasive cardiac output (CO) monitoring technologies lack validation in the adolescent population. We aimed to test the accuracy and precision of the FloTrac arterial pressure cardiac output (APCO) and ClearSight photoplethysmography cardiac output (PPGCO; Edwards Lifesciences, Irvine, CA) technologies in adolescents undergoing elective cardiac catheterization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Prospective, single-arm, nonrandomized, observational study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Cardiac catheterization laboratory at three freestanding pediatric hospitals in the United States.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients:<\/jats:title>\n                    <jats:p>Adolescent patients 12\u201318 years of age undergoing surveillance cardiac catheterization after heart transplantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions:<\/jats:title>\n                    <jats:p>Swan-Ganz pulmonary artery catheterization with the intermittent thermodilution CO (iCO) technique was used as the gold standard for CO measurements. APCO was measured using an existing femoral arterial sheath, and PPGCO was measured utilizing a volumetric cuff placed on the finger of the upper extremities. Two sets of simultaneous iCO, APCO, and PPGCO measurements were compared. Bias and level of concordance were assessed using Bland-Altman analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Measurements and Main Results:<\/jats:title>\n                    <jats:p>\n                      Out of the 89 subjects enrolled, 73 underwent measurements and provided a total of 60 sets of measurements for each device. The median age was 16 years (interquartile range [IQR], 14\u201317 yr) with a median body surface area of 1.6 m\n                      <jats:sup>2<\/jats:sup>\n                      (IQR, 1.5\u20131.8 m\n                      <jats:sup>2<\/jats:sup>\n                      ). The median averaged intermittent cardiac index was 2.7\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      (IQR, 2.3\u20133.1\u2009L\/min\/m\n                      <jats:sup>2)<\/jats:sup>\n                      . FloTrac APCO mean bias was 0.32\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      (IQR, 0.20\u20130.44\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      ) with a precision of 0.70\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      (IQR, 0.58\u20130.82\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      ). ClearSight PPGCO mean bias was 0.28\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      (95% CI, 0.16\u20130.41\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      ) with a precision of 0.71\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      (95% CI, 0.59\u20130.84\u2009L\/min\/m\n                      <jats:sup>2<\/jats:sup>\n                      ). No serious adverse events were reported related to the devices.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The minimally and noninvasive CO measurements with FloTrac and ClearSight APCO show acceptable bias and precision under standardized elective clinical conditions in an adolescent pediatric population, making them useful tools in the routine clinical management of critically ill children.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/pcc.0000000000003986","type":"journal-article","created":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:45:33Z","timestamp":1786038333000},"page":"986-997","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Validation of Minimally Invasive and Noninvasive Hemodynamic Monitoring in Adolescents: The Pediatric Cardiac Output Monitoring Observational (POGO) Study"],"prefix":"10.1097","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8582-4759","authenticated-orcid":false,"given":"Sebastian C.","family":"Tume","sequence":"first","affiliation":[{"name":"Department of Pediatrics, Baylor College of Medicine, Division of Critical Care Medicine, Texas Children\u2019s Hospital, Houston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael L.","family":"O\u2019Byrne","sequence":"additional","affiliation":[{"name":"Division of Cardiology, The Children\u2019s Hospital of Philadelphia, Department of Pediatrics, Perelman School of Medicine, The University of Pennsylvania, Philadelphia, PA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Curt","family":"Fudge","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Congenital Heart Center, University of Florida College of Medicine, Gainesville, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc M.","family":"Anders","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Baylor College of Medicine, Division of Critical Care Medicine, Texas Children\u2019s Hospital, Houston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dipankar","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Congenital Heart Center, University of Florida College of Medicine, Gainesville, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,6]]},"reference":[{"key":"R1-20260806","doi-asserted-by":"crossref","first-page":"e011991","DOI":"10.1161\/JAHA.119.011991","article-title":"Cardiogenic shock.","volume":"8","author":"Vahdatpour","year":"2019","journal-title":"J Am Heart Assoc"},{"key":"R2-20260806","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/j.jchf.2020.08.012","article-title":"Complete hemodynamic profiling with pulmonary artery catheters in cardiogenic shock is associated with lower in-hospital mortality.","volume":"8","author":"Garan","year":"2020","journal-title":"JACC Heart Fail"},{"key":"R3-20260806","doi-asserted-by":"crossref","first-page":"2559","DOI":"10.1001\/jama.283.19.2559","article-title":"Patient characteristics and ICU organizational factors that influence frequency of pulmonary artery catheterization.","volume":"283","author":"Rapoport","year":"2000","journal-title":"JAMA"},{"key":"R5-20260806","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1152\/jappl.1953.5.10.635","article-title":"The Fick principle: Analysis of potential errors in its conventional application.","volume":"5","author":"Visscher","year":"1953","journal-title":"J Appl Physiol"},{"key":"R6-20260806","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1093\/bja\/75.6.719","article-title":"Comparison between oxygen consumption calculated by Fick\u2019s principle using a continuous thermodilution technique and measured by indirect calorimetry.","volume":"75","author":"Bizouarn","year":"1995","journal-title":"Br J Anaesth"},{"key":"R7-20260806","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/BF02474767","article-title":"A simple mathematical derivation of the Stewart-Hamilton formula for the determination of cardiac output.","volume":"7","author":"Valentinuzzi","year":"1969","journal-title":"Med Biol Eng"},{"key":"R8-20260806","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1213\/ANE.0b013e3181cc885a","article-title":"Cardiac output monitoring using indicator-dilution techniques: Basics, limits, and perspectives.","volume":"110","author":"Reuter","year":"2010","journal-title":"Anesth Analg"},{"key":"R9-20260806","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1161\/CIRCULATIONAHA.119.043080","article-title":"Value of hemodynamic monitoring in patients with cardiogenic shock undergoing mechanical circulatory support.","volume":"141","author":"Saxena","year":"2020","journal-title":"Circulation"},{"key":"R10-20260806","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1111\/j.1460-9592.2008.02720.x","article-title":"Cardiac output measurement in pediatric anesthesia.","volume":"18","author":"Skowno","year":"2008","journal-title":"Paediatr Anaesth"},{"key":"R11-20260806","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1097\/ALN.0000000000002673","article-title":"Babies and children at last: Pediatric cardiac output monitoring in the twenty-first century.","volume":"130","author":"Trieu","year":"2019","journal-title":"Anesthesiology"},{"key":"R12-20260806","doi-asserted-by":"crossref","first-page":"403","DOI":"10.2345\/0899-8205(2007)41[403:CAPCOU]2.0.CO;2","article-title":"Calculating arterial pressure-based cardiac output using a novel measurement and analysis method.","volume":"41","author":"Pratt","year":"2007","journal-title":"Biomed Instrum Technol"},{"key":"R13-20260806","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s10877-012-9375-8","article-title":"Noninvasive continuous hemodynamic monitoring.","volume":"26","author":"Truijen","year":"2012","journal-title":"J Clin Monit Comput"},{"key":"R14-20260806","first-page":"67","article-title":"Physiocal, calibrating finger vascular physiology for finapres.","volume":"36","author":"Wesseling","year":"1995","journal-title":"Homeost Health Dis"},{"key":"R16-20260806","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement.","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"R17-20260806","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual.","volume":"17","author":"Bland","year":"2007","journal-title":"J Biopharm Stat"},{"key":"R18-20260806","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1161\/CIRCULATIONAHA.108.811141","article-title":"The Swan-Ganz catheters: Past, present, and future. A viewpoint.","volume":"119","author":"Chatterjee","year":"2009","journal-title":"Circulation"},{"key":"R19-20260806","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1213\/ane.0b013e31818ffd99","article-title":"Minimally invasive cardiac output monitoring in the perioperative setting.","volume":"108","author":"Funk","year":"2009","journal-title":"Anesth Analg"},{"key":"R20-20260806","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1007\/BF03011312","article-title":"Errors in the measurement of cardiac output by thermodilution.","volume":"40","author":"Nishikawa","year":"1993","journal-title":"Can J Anaesth"},{"key":"R21-20260806","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1152\/jappl.2000.89.1.89","article-title":"Effect of the mechanical ventilatory cycle on thermodilution right ventricular volumes and cardiac output.","volume":"89","author":"Groeneveld","year":"2000","journal-title":"J Appl Physiol (1985)"},{"key":"R22-20260806","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1007\/BF03027130","article-title":"Limitations of cardiac output measurements by thermodilution.","volume":"33","author":"Nadeau","year":"1986","journal-title":"Can Anaesth Soc J"},{"key":"R23-20260806","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.jtcvs.2006.07.038","article-title":"Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery.","volume":"133","author":"Fakler","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R24-20260806","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1213\/01.ANE.0000081797.61469.12","article-title":"Pulse contour analysis for cardiac output monitoring in cardiac surgery for congenital heart disease.","volume":"97","author":"Mahajan","year":"2003","journal-title":"Anesth Analg"},{"key":"R25-20260806","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1111\/j.1399-6576.2006.01080.x","article-title":"Cardiac output-pulse contour analysis vs. pulmonary artery thermodilution.","volume":"50","author":"Ostergaard","year":"2006","journal-title":"Acta Anaesthesiol Scand"},{"key":"R26-20260806","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1093\/bja\/aem177","article-title":"Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.","volume":"99","author":"Sakka","year":"2007","journal-title":"Br J Anaesth"},{"key":"R27-20260806","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/PCC.0b013e31816c7151","article-title":"Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiography.","volume":"9","author":"Calamandrei","year":"2008","journal-title":"Pediatr Crit Care Med"},{"key":"R28-20260806","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1111\/pan.12997","article-title":"Measuring cardiac output in children undergoing cardiac catheterization: Comparison between the Fick method and PRAM (pressure recording analytical method).","volume":"26","author":"Alonso-I\u00f1igo","year":"2016","journal-title":"Paediatr Anaesth"},{"key":"R29-20260806","doi-asserted-by":"crossref","first-page":"1834","DOI":"10.1097\/00003246-200208000-00027","article-title":"Assessment of cardiac output from systemic arterial pressure in humans.","volume":"30","author":"Romano","year":"2002","journal-title":"Crit Care Med"},{"key":"R30-20260806","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1177\/0310057X1003800211","article-title":"Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution.","volume":"38","author":"Hamm","year":"2010","journal-title":"Anaesth Intensive Care"},{"key":"R31-20260806","doi-asserted-by":"crossref","first-page":"A43","DOI":"10.1097\/00003246-200412001-00163","article-title":"Cardiac output determination using arterial pulse: A comparison of a novel algorithm against continuous and intermittent thermodiluation: 166.","volume":"32","author":"Manecke","year":"2004","journal-title":"Crit Care Med"},{"key":"R32-20260806","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/MBP.0000000000000458","article-title":"Use of pulse contour technology for continuous blood pressure monitoring in pediatric patients.","volume":"25","author":"Alharash","year":"2020","journal-title":"Blood Press Monit"},{"key":"R33-20260806","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1111\/anae.14638","article-title":"Cardiac output monitoring with thermodilution pulse-contour analysis vs. non-invasive pulse-contour analysis.","volume":"74","author":"Boisson","year":"2019","journal-title":"Anaesthesia"},{"key":"R34-20260806","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1093\/cvr\/19.3.139","article-title":"Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger.","volume":"19","author":"Wesseling","year":"1985","journal-title":"Cardiovasc Res"},{"key":"R35-20260806","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1213\/ANE.0b013e31829562c3","article-title":"Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: A comparison with intermittent thermodilution cardiac output.","volume":"117","author":"Bubenek-Turconi","year":"2013","journal-title":"Anesth Analg"},{"key":"R36-20260806","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1471-2253-9-6","article-title":"Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients.","volume":"9","author":"Stover","year":"2009","journal-title":"BMC Anesthesiol"},{"key":"R37-20260806","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/s10877-015-9744-1","article-title":"Continuous noninvasive cardiac output determination using the CNAP system: Evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.","volume":"30","author":"Wagner","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"R38-20260806","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/S0008-6363(97)00003-5","article-title":"Models of brachial to finger pulse wave distortion and pressure decrement.","volume":"33","author":"Gizdulich","year":"1997","journal-title":"Cardiovasc Res"}],"container-title":["Pediatric Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/PCC.0000000000003986","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:45:37Z","timestamp":1786038337000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/PCC.0000000000003986"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":36,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/pcc.0000000000003986","relation":{},"ISSN":["1529-7535","1947-3893"],"issn-type":[{"value":"1529-7535","type":"print"},{"value":"1947-3893","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]}}}