{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,23]],"date-time":"2025-08-23T05:13:31Z","timestamp":1755926011350},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatr Emer Care"],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Our objective was to describe the sonographic appearance of fluid at clinically selected interspinous spaces and see if additional interspaces could be identified as suitable and safe targets for needle insertion. We also measured the reproducibility of fluid measurements and assessed for positional differences.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A prospective convenience sample of infants younger than 3 months was enrolled in the pediatric emergency department. Excluded were clinically unstable infants or those with spinal dysraphism. Infants were first held in standard lateral lumbar puncture position. Pediatric emergency medicine (PEM) physicians marked infants' backs at the level they would insert a needle using the landmark palpation technique. A PEM sonologist imaged and measured the spinal fluid in 2 orthogonal planes at this marked level in lateral then sitting positions. Fluid measurements were repeated by a second blinded PEM sonologist.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Forty-six infants were enrolled. Ultrasound verified the presence of fluid at the marked level as determined by the landmark palpation technique in 98% of cases. Ultrasound identified additional suitable spaces 1 space higher (82%) and 2 spaces higher (41%). Intraclass correlation coefficient of all measurements was excellent (&gt;0.85), with differences noted for sitting versus lateral position in mean area of fluid 0.34 mm<jats:sup>2<\/jats:sup> versus 0.31 mm<jats:sup>2<\/jats:sup> (difference, 0.03; 95% confidence interval [CI], 0.005\u20130.068), dorsal fluid pocket 0.23 mm<jats:sup>2<\/jats:sup> versus 0.15 mm<jats:sup>2<\/jats:sup> (difference, 0.08; 95% CI, 0.031\u20130.123), and nerve root-to-canal ratio 0.44 versus 0.51 (difference, 0.07; 95% CI, 0.004\u20130.117).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Ultrasound can verify the presence of fluid at interspaces determined by the landmark palpation technique and identify additional suitable spaces at higher levels. There were statistically greater fluid measurements in sitting versus lateral positions. These novel fluid measurements were shown to be reliable.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/pec.0000000000000793","type":"journal-article","created":{"date-parts":[[2016,8,9]],"date-time":"2016-08-09T16:57:29Z","timestamp":1470761849000},"page":"334-338","source":"Crossref","is-referenced-by-count":5,"title":["The Sonographic Appearance of Spinal Fluid at Clinically Selected Interspaces in Sitting Versus Lateral Positions"],"prefix":"10.1097","volume":"34","author":[{"given":"Yaffa M.","family":"Vitberg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peggy","family":"Tseng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David O.","family":"Kessler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20231023","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1016\/j.annemergmed.2006.10.018","article-title":"Risk factors for traumatic or unsuccessful lumbar punctures in children","volume":"49","year":"2007","journal-title":"Ann Emerg Med"},{"key":"bib2-20231023","doi-asserted-by":"crossref","first-page":"e811","DOI":"10.1542\/peds.2012-0607","article-title":"Interns' success with clinical procedures in infants after simulation training","volume":"131","year":"2013","journal-title":"Pediatrics"},{"key":"bib3-20231023","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1007\/s002470100453","article-title":"Diagnostic and interventional ultrasonography in neonatal and infant lumbar puncture","volume":"31","year":"2001","journal-title":"Pediatr Radiol"},{"key":"bib4-20231023","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1542\/peds.2009-0646","article-title":"Positioning for lumbar puncture in children evaluated by bedside ultrasound","volume":"125","year":"2010","journal-title":"Pediatrics"},{"key":"bib5-20231023","first-page":"215","article-title":"Evaluating infant positioning for lumbar puncture using sonographic measurements","volume":"18","year":"2011","journal-title":"Acad Emerg Med"},{"key":"bib6-20231023","doi-asserted-by":"crossref","first-page":"e921","DOI":"10.1542\/peds.2010-2511","article-title":"Needle-entry angle for lumbar puncture in children as determined by using ultrasonography","volume":"127","year":"2011","journal-title":"Pediatrics"},{"key":"bib7-20231023","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1097\/PEC.0b013e31828e630d","article-title":"Sitting or tilt position for infant lumbar puncture does not increase ultrasound measurements of lumbar subarachnoid space width","volume":"29","year":"2013","journal-title":"Pediatr Emerg Care"},{"key":"bib8-20231023","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/j.1365-2044.2004.03657.x","article-title":"The tenth rib line as a new landmark of the lumbar vertebral level during spinal block","volume":"59","year":"2004","journal-title":"Anaesthesia"},{"key":"bib9-20231023","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.2214\/ajr.152.5.1029","article-title":"John Caffey award. MR imaging determination of the location of the normal conus medullaris throughout childhood","volume":"152","year":"1989","journal-title":"Am J Roentgenol"},{"key":"bib10-20231023","first-page":"469","article-title":"Ultrasound determination of the normal location of the conus medullaris in neonates","volume":"16","year":"1995","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib11-20231023","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1007\/BF02015359","article-title":"The conus medullaris: time of ascendence to normal level","volume":"22","year":"1992","journal-title":"Pediatr Radiol"},{"key":"bib12-20231023","doi-asserted-by":"crossref","first-page":"F67","DOI":"10.1136\/fn.77.1.F67","article-title":"Level of conus medullaris in term and preterm neonates","volume":"77","year":"1997","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"bib13-20231023","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1007\/s00381-013-2310-6","article-title":"Sonographic determination of normal conus medullaris level and ascent in early infancy","volume":"30","year":"2014","journal-title":"Childs Nerv Syst"},{"key":"bib14-20231023","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1046\/j.1460-9592.2003.01120.x","article-title":"Investigation of the radiological relationship between iliac crests, conus medullaris and vertebral level in children","volume":"13","year":"2003","journal-title":"Pediatr Anesth"},{"key":"bib15-20231023","first-page":"E7","article-title":"Termination of the normal conus medullaris in children: a whole-spine magnetic resonance imaging study","volume":"23","year":"2007","journal-title":"Neurosurg Focus"},{"key":"bib16-20231023","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1111\/acem.12582","article-title":"The effect of traumatic lumbar puncture on hospitalization rate for febrile infants 28 to 60 days of age","volume":"22","year":"2015","journal-title":"Acad Emerg Med"},{"key":"bib17-20231023","first-page":"303","article-title":"Ultrasound guided lumbar puncture in emergency department: time saving and less complications","volume":"18","year":"2013","journal-title":"J Res Med Sci"},{"key":"bib18-20231023","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1542\/peds.2006-1191","article-title":"Factors associated with lumbar puncture success","volume":"118","year":"2006","journal-title":"Pediatrics"},{"key":"bib19-20231023","doi-asserted-by":"crossref","first-page":"F133","DOI":"10.1136\/archdischild-2011-301475","article-title":"Positioning of infants in the neonatal intensive care unit for lumbar puncture as determined by bedside ultrasonography","volume":"98","year":"2013","journal-title":"Arch Dis Child Fetal Neonatal Ed"}],"container-title":["Pediatric Emergency Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00006565-201805000-00008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T02:11:23Z","timestamp":1698027083000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00006565-201805000-00008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/pec.0000000000000793","relation":{},"ISSN":["1535-1815","0749-5161"],"issn-type":[{"value":"1535-1815","type":"electronic"},{"value":"0749-5161","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}