{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T18:40:02Z","timestamp":1746384002702,"version":"3.40.4"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Pediatr Emer Care"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Central venous catheters are commonly used in emergency department and the intensive care units for the treatment of critically ill patients. Reports on the rate of mechanical complications of catheter insertion are around 1%. Mechanical complications related with the insertion of the catheter mainly depend on the anatomic location, the use of ultrasound, and experience of the operator. The rate of complication is higher in places where central lines are not routinely inserted as in emergency department. Here, we report a case series of 4 patients who had life-threatening complications of central venous catheter insertion, including venous intimal injury leading to pleural effusion, kinked central venous catheter in the superior vena cava, knotted guidewire with the separation of coil and core, and a missed guidewire with their respective insertion history and imaging. Increasing the awareness of and developing strategies to prevent these rare but potentially fatal conditions may have impact on patient outcomes.<\/jats:p>","DOI":"10.1097\/pec.0000000000002390","type":"journal-article","created":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T12:33:18Z","timestamp":1614774798000},"page":"e775-e778","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A Case Series of Life-Threatening Complications of Central Venous Catheter Insertion"],"prefix":"10.1097","volume":"37","author":[{"given":"Emine","family":"Akkuzu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u015eahin","family":"Sincar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00f6khan","family":"Kalkan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,3,3]]},"reference":[{"key":"bib1-20250504","first-page":"61","article-title":"Mechanical complications of central venous catheter insertions: a retrospective multicenter study of incidence and risks","volume":"63","year":"2018","journal-title":"Acta Anaesthesiol Scand"},{"key":"bib2-20250504","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1177\/0885066605280884","article-title":"Mechanical complications of central venous catheters","volume":"21","year":"2006","journal-title":"J Intensive Care Med"},{"key":"bib3-20250504","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/00006565-200008000-00003","article-title":"Uses and complications of central venous catheters inserted in a pediatric emergency department","volume":"16","year":"2000","journal-title":"Pediatr Emerg Care"},{"key":"bib4-20250504","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1001\/jama.286.6.700","article-title":"Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial","volume":"286","year":"2001","journal-title":"JAMA"},{"key":"bib5-20250504","first-page":"113","article-title":"Pleural effusion with intimal injury of superior vena cava caused by central venous catheter: report of a case","volume":"34","year":"1987","journal-title":"Tokushima J Exp Med"},{"key":"bib6-20250504","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1097\/00000658-198904000-00014","article-title":"Central venous catheter vascular erosions. Diagnosis and clinical course","volume":"209","year":"1989","journal-title":"Ann Surg"},{"key":"bib7-20250504","doi-asserted-by":"crossref","first-page":"507","DOI":"10.5301\/jva.5000286","article-title":"Mechanical properties of Seldinger guidewires","volume":"15","year":"2014","journal-title":"J Vasc Access"},{"key":"bib8-20250504","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1007\/BF03021773","article-title":"Broken guide wire\u2014a fault of design?","volume":"52","year":"2005","journal-title":"Can J Anaesth"},{"key":"bib9-20250504","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.jclinane.2016.07.032","article-title":"Confirmation of optimal guidewire length for central venous catheter placement using transesophageal echocardiography","volume":"35","year":"2016","journal-title":"J Clin Anesth"},{"key":"bib10-20250504","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1053\/jcan.2003.34","article-title":"Kinked triple-lumen central venous catheter due to superior vena caval cannula: An unusual complication","volume":"17","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"bib11-20250504","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/BF03022660","article-title":"Case report: managing a knotted Seldinger wire in the subclavian vein during central venous cannulation","volume":"54","year":"2007","journal-title":"Can J Anaesth"},{"key":"bib12-20250504","doi-asserted-by":"crossref","first-page":"78","DOI":"10.4103\/2006-8808.128732","article-title":"Loss of guide wire: a lesson learnt review of literature","volume":"5","year":"2013","journal-title":"J Surg Tech Case Rep"},{"key":"bib13-20250504","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1093\/bja\/88.1.144","article-title":"Loss of the guide wire: mishap or blunder?","volume":"88","year":"2002","journal-title":"Br J Anaesth"},{"key":"bib14-20250504","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1378\/chest.10-3319","article-title":"A Prerotational, Simulation-based workshop improves the safety of central venous catheter insertion: results of a successful internal medicine house staff training program","volume":"140","year":"2011","journal-title":"Chest"},{"key":"bib15-20250504","doi-asserted-by":"crossref","first-page":"23","DOI":"10.3233\/JRS-140610","article-title":"Guidewire retention following central venous catheterisation: a human factors and safe design investigation","volume":"26","year":"2014","journal-title":"Int J Risk Saf Med"}],"container-title":["Pediatric Emergency Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PEC.0000000000002390","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T18:08:27Z","timestamp":1746382107000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PEC.0000000000002390"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,3]]},"references-count":15,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/pec.0000000000002390","relation":{},"ISSN":["1535-1815","0749-5161"],"issn-type":[{"type":"electronic","value":"1535-1815"},{"type":"print","value":"0749-5161"}],"subject":[],"published":{"date-parts":[[2021,3,3]]}}}