{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T11:04:22Z","timestamp":1788865462998,"version":"build-2803163510"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Phys Med Rehabil"],"published-print":{"date-parts":[[2020,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Functional electrical stimulation therapy (FEST) is a state-of-the-art treatment for retraining motor function after neurological injuries. Recent literature suggests that FEST can be further improved with brain-computer interface (BCI) technology. In this case study, we assessed the feasibility of using BCI-triggered FEST (BCI-FEST) to restore upper limb function in a 57-yr-old man with severe left hemiplegia resulting from a stroke 6 yrs before enrollment in the study. The intervention consisted of two blocks of forty 1-hr BCI-FEST sessions, with three sessions delivered weekly. During therapy, a single-channel BCI was used to trigger the stimulation programmed to facilitate functional movements. The measure of the feasibility of the BCI-FEST included assessing the implementation and safety of the intervention. Clinical improvements were assessed using (<jats:italic toggle=\"yes\">a<\/jats:italic>) Functional Independence Measure, (<jats:italic toggle=\"yes\">b<\/jats:italic>) Action Research Arm Test, (<jats:italic toggle=\"yes\">c<\/jats:italic>) Toronto Rehabilitation Institute \u2013 Hand Function Test, and (<jats:italic toggle=\"yes\">d<\/jats:italic>) Fugl-Meyer Assessment Upper Extremity test. Upon completion of 80 therapy sessions, 14-, 17-, and 18-point changes were recorded on Action Research Arm Test, Fugl-Meyer Assessment Upper Extremity test, and Toronto Rehabilitation Institute \u2013 Hand Function Test, respectively. The participant also indicated improvement as demonstrated by his ability to perform various day-to-day tasks. The results suggest that BCI-FEST is safe and viable.<\/jats:p>","DOI":"10.1097\/phm.0000000000001163","type":"journal-article","created":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T19:28:15Z","timestamp":1551382095000},"page":"e35-e40","source":"Crossref","is-referenced-by-count":34,"title":["Restoration of Upper Limb Function After Chronic Severe Hemiplegia"],"prefix":"10.1097","volume":"99","author":[{"given":"Lazar I.","family":"Jovanovic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naaz","family":"Kapadia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorna","family":"Lo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vera","family":"Zivanovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milos R.","family":"Popovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesar","family":"Marquez-Chin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,2,14]]},"reference":[{"key":"bib1-20230922","first-page":"e146","article-title":"Heart Disease and Stroke Statistics-2017 Update: a report from the American Heart Association","volume":"135","year":"2017","journal-title":"Circulation"},{"key":"bib2-20230922","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/S1474-4422(04)00851-8","article-title":"Strategies for stroke rehabilitation","volume":"3","year":"2004","journal-title":"Lancet Neurol"},{"key":"bib4-20230922","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1177\/1545968308317436","article-title":"Rehabilitation of reaching and grasping function in severe hemiplegic patients using functional electrical stimulation therapy","volume":"22","year":"2008","journal-title":"Neurorehabil Neural Repair"},{"key":"bib5-20230922","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1682\/JRRD.2003.09.0443","article-title":"Clinical evaluation of functional electrical therapy in acute hemiplegic subjects","volume":"40","year":"2003","journal-title":"J Rehabil Res Dev"},{"key":"bib6-20230922","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1111\/j.1094-7159.2005.05221.x","article-title":"Neuroprosthesis for retraining reaching and grasping functions in severe hemiplegic patients","volume":"8","year":"2005","journal-title":"Neuromodulation"},{"key":"bib7-20230922","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1177\/1545968310392924","article-title":"Functional electrical stimulation therapy of voluntary grasping versus only conventional rehabilitation for patients with subacute incomplete tetraplegia: a randomized clinical trial","volume":"25","year":"2011","journal-title":"Neurorehabil Neural Repair"},{"key":"bib8-20230922","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1080\/16501970410035387","article-title":"Controlled study of neuroprosthetic functional electrical stimulation in sub-acute post-stroke rehabilitation","volume":"37","year":"2005","journal-title":"J Rehabil Med Suppl"},{"key":"bib9-20230922","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1177\/0308022617719807","article-title":"Examining a new functional electrical stimulation therapy with people with severe upper extremity hemiparesis and chronic stroke: a feasibility study","volume":"80","year":"2017","journal-title":"Br J Occup Ther"},{"key":"bib10-20230922","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1038\/sj.sc.3101822","article-title":"Functional electrical therapy: retraining grasping in spinal cord injury","volume":"44","year":"2006","journal-title":"Spinal Cord"},{"key":"bib12-20230922","doi-asserted-by":"crossref","first-page":"13","DOI":"10.2340\/1650197771331","article-title":"The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance","volume":"7","year":"1975","journal-title":"Scand J Rehabil Med"},{"key":"bib13-20230922","doi-asserted-by":"crossref","first-page":"791","DOI":"10.2522\/ptj.20110009","article-title":"Clinically important differences for the upper-extremity Fugl-Meyer scale in people with minimal to moderate impairment due to chronic stroke","volume":"92","year":"2012","journal-title":"Phys Ther"},{"key":"bib14-20230922","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.1113\/jphysiol.2011.222851","article-title":"Precise temporal association between cortical potentials evoked by motor imagination and afference induces cortical plasticity","volume":"590","year":"2012","journal-title":"J Physiol"},{"key":"bib15-20230922","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1152\/jn.00918.2015","article-title":"Efficient neuroplasticity induction in chronic stroke patients by an associative brain-computer interface","volume":"115","year":"2016","journal-title":"J Neurophysiol"},{"key":"bib16-20230922","doi-asserted-by":"crossref","first-page":"65002","DOI":"10.1088\/1741-2560\/13\/6\/065002","article-title":"Rehabilitation of hand in subacute tetraplegic patients based on brain computer interface and functional electrical stimulation: a randomised pilot study","volume":"13","year":"2016","journal-title":"J Neural Eng"},{"key":"bib17-20230922","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1016\/S1474-4422(08)70223-0","article-title":"Brain\u2013computer interfaces in neurological rehabilitation","volume":"7","year":"2008","journal-title":"Lancet Neurol"},{"key":"bib18-20230922","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1002\/oti.1403","article-title":"Effects of action observational training plus brain\u2013computer interface-based functional electrical stimulation on paretic arm motor recovery in patient with stroke: a randomized controlled trial","volume":"23","year":"2016","journal-title":"Occup Ther Int"},{"key":"bib19-20230922","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1097\/NPT.0b013e3181c1fc0b","article-title":"Feasibility of a new application of noninvasive brain computer interface (BCI): a case study of training for recovery of volitional motor control after stroke","volume":"33","year":"2009","journal-title":"J Neurol Phys Ther"},{"key":"bib20-20230922","doi-asserted-by":"crossref","first-page":"1842","DOI":"10.1016\/S1388-2457(99)00141-8","article-title":"Event-related EEG\/MEG synchronization and desynchronization: basic principles","volume":"110","year":"1999","journal-title":"Clin Neurophysiol"},{"key":"bib21-20230922","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S1388-2457(01)00697-6","article-title":"Visualization of significant ERD\/ERS patterns in multichannel EEG and ECoG data","volume":"113","year":"2002","journal-title":"Clin Neurophysiol"},{"key":"bib22-20230922","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/00004691-198804000-00005","article-title":"Modified nomenclature for the \u201c10%\u201d electrode system","volume":"5","year":"1988","journal-title":"J Clin Neurophysiol"},{"key":"bib23-20230922","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1046\/j.1525-1594.2002.06934.x","article-title":"Transcutaneous functional electrical stimulator \u201cCompex Motion\u201d","volume":"26","year":"2002","journal-title":"Artif Organs"},{"key":"bib24-20230922","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1016\/S0003-9993(96)90184-7","article-title":"The reliability of the functional independence measure: a quantitative review","volume":"77","year":"1996","journal-title":"Arch Phys Med Rehabil"},{"key":"bib25-20230922","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/00004356-198112000-00001","article-title":"A performance test for assessment of upper limb function in physical rehabilitation treatment and research","volume":"4","year":"1981","journal-title":"Int J Rehabil Res"},{"key":"bib26-20230922","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1310\/sci1802-167","article-title":"Toronto Rehabilitation Institute\u2013Hand Function Test: assessment of gross motor function in individuals with spinal cord injury","volume":"18","year":"2012","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"bib27-20230922","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1053\/apmr.2001.18668","article-title":"The intra- and interrater reliability of the action research arm test: a practical test of upper extremity function in patients with stroke","volume":"82","year":"2001","journal-title":"Arch Phys Med Rehabil"},{"key":"bib28-20230922","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.apmr.2016.06.023","article-title":"Determining levels of upper extremity movement impairment by applying a cluster analysis to the Fugl-Meyer Assessment of the Upper Extremity in chronic stroke","volume":"98","year":"2017","journal-title":"Arch Phys Med Rehabil"},{"key":"bib29-20230922","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/00001199-199610000-00004","article-title":"Functional measures after traumatic brain injury: ceiling effects of FIM, FIM+FAM, DRS, and CIQ","volume":"11","year":"1996","journal-title":"J Head Trauma Rehabil"}],"container-title":["American Journal of Physical Medicine &amp; Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PHM.0000000000001163","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T20:13:11Z","timestamp":1695413591000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PHM.0000000000001163"}},"subtitle":["A Case Report on the Feasibility of a Brain-Computer Interface-Triggered Functional Electrical Stimulation Therapy"],"short-title":[],"issued":{"date-parts":[[2019,2,14]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/phm.0000000000001163","relation":{},"ISSN":["1537-7385","0894-9115"],"issn-type":[{"value":"1537-7385","type":"electronic"},{"value":"0894-9115","type":"print"}],"subject":[],"published":{"date-parts":[[2019,2,14]]}}}