{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T07:03:12Z","timestamp":1756191792343},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Phys Med Rehabil"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The aims of the study were to report the demographic characteristics and functional mobility for individuals accessing an academic medical center mobility device clinic and to compare functional mobility data across demographic characteristics and mobility device type.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design<\/jats:title>\n            <jats:p>This study used a retrospective, cross-sectional design. Demographic, mobility type, and patient-reported outcome measure data for 833 clients were analyzed. The Functional Mobility Assessment was used as the patient-reported outcome measure to determine satisfaction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The mean (SD) baseline Functional Mobility Assessment score was 0.59 (0.25) on a 0\u20131 scale. Significant differences with the Functional Mobility Assessment scores were found across the mobility device types, with scooter and power wheelchair groups reporting higher satisfaction scores than those in the cane\/crutch\/walker or manual wheelchair groups. Device type, sex, and age were each found to be significant predictors of satisfaction scores (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.01).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Mobility device type is associated with satisfaction level. Mobility devices that offer higher levels of assistance are associated with increased satisfaction. The Functional Mobility Assessment, mobility device type, and demographic data provide baseline information for evaluating the effectiveness of an academic medical center mobility device clinic.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/phm.0000000000001245","type":"journal-article","created":{"date-parts":[[2019,6,15]],"date-time":"2019-06-15T03:32:56Z","timestamp":1560569576000},"page":"1072-1078","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of Service Delivery Effectiveness Through Patient-Reported Outcome Measures"],"prefix":"10.1097","volume":"98","author":[{"given":"Julie","family":"Faieta","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark R.","family":"Schmeler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vince J.","family":"Schiappa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brittany N.","family":"Hand","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard M.","family":"Schein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andi","family":"Saptono","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Theresa","family":"Berner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmen P.","family":"DiGiovine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2019,6,14]]},"reference":[{"key":"bib3-20230922","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/00001163-200310000-00002","article-title":"Integrating assistive technology into an outcome-driven model of service delivery","volume":"16","year":"2003","journal-title":"Infants Young Child"},{"key":"bib5-20230922","doi-asserted-by":"crossref","first-page":"125","DOI":"10.3233\/TAD-2002-14308","article-title":"Matching person & technology (MPT) assessment process","volume":"14","year":"2002","journal-title":"Technol Disabil"},{"key":"bib7-20230922","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.apmr.2008.12.007","article-title":"A preliminary model of wheelchair service delivery","volume":"90","year":"2009","journal-title":"Arch Phys Med Rehabil"},{"key":"bib9-20230922","doi-asserted-by":"crossref","first-page":"131","DOI":"10.3233\/TAD-2011-0321","article-title":"Advances in European Assistive Technology service delivery and recommendations for further improvement","volume":"23","year":"2011","journal-title":"Technol Disabil"},{"key":"bib10-20230922","first-page":"1","article-title":"Satisfaction of users with assistive technology service delivery: an exploratory analysis of experiences of parents of children with physical and multiple disabilities","volume":"19","year":"2014","journal-title":"Dev Neurorehabil"},{"key":"bib11-20230922","doi-asserted-by":"crossref","first-page":"127","DOI":"10.3233\/TAD-130381","article-title":"Service delivery systems for assistive technology in Europe: an AAATE\/EASTIN position paper","volume":"25","year":"2013","journal-title":"Technol Disabil"},{"key":"bib14-20230922","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/10400435.2004.10132069","article-title":"A new conceptual model for assistive technology outcomes research and practice","volume":"16","year":"2004","journal-title":"Assist Technol"},{"key":"bib15-20230922","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1080\/10400435.2017.1367737","article-title":"Satisfaction with assistive technology device in relation to the service delivery process\u2014A systematic review","volume":"31","year":"2019","journal-title":"Assist Technol."},{"key":"bib16-20230922","doi-asserted-by":"crossref","first-page":"373","DOI":"10.3109\/17483107.2012.749429","article-title":"Consumer perspectives on assistive technology outcomes","volume":"8","year":"2013","journal-title":"Disabil Rehabil Assist Technol"},{"key":"bib17-20230922","doi-asserted-by":"crossref","first-page":"2477","DOI":"10.1056\/NEJMp1011024","article-title":"What is value in health care?","volume":"363","year":"2010","journal-title":"N Engl J Med"},{"key":"bib19-20230922","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1016\/j.apmr.2008.01.010","article-title":"Issues for the selection of wheelchair-specific activity and participation outcome measures: a review","volume":"89","year":"2008","journal-title":"Arch Phys Med Rehabil"},{"key":"bib20-20230922","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1080\/09638280110066334","article-title":"Development and consumer validation of the Functional Evaluation in a Wheelchair (FEW) instrument","volume":"24","year":"2002","journal-title":"Disabil Rehabil"},{"key":"bib21-20230922","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1080\/10400435.2007.10131866","article-title":"Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument","volume":"19","year":"2007","journal-title":"Assist Technol"},{"key":"bib22-20230922","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1016\/j.apmr.2010.01.017","article-title":"Telerehabilitation wheeled mobility and seating assessments compared with in person","volume":"91","year":"2010","journal-title":"Arch Phys Med Rehabil"},{"key":"bib23-20230922","doi-asserted-by":"crossref","first-page":"213","DOI":"10.3109\/17483107.2012.688240","article-title":"Test-retest reliability of the functional mobility assessment (FMA): a pilot study","volume":"8","year":"2013","journal-title":"Disabil Rehabil Assist Technol"},{"key":"bib25-20230922","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1682\/JRRD.2005.11.0174","article-title":"Demographic characteristics of veterans who received wheelchairs and scooters from Veterans Health Administration","volume":"43","year":"2006","journal-title":"J Rehabil Res Dev"},{"key":"bib26-20230922","first-page":"11","article-title":"Demographic profile of older adults using wheeled mobility devices","volume":"2011","year":"2011","journal-title":"J Aging Res"},{"key":"bib27-20230922","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1080\/10400435.2017.1402391","article-title":"Data-mining analysis of the provision of mobility devices in the United States with emphasis on complex rehab technology","volume":"31","year":"2019","journal-title":"Assist Technol Off J RESNA"},{"key":"bib28-20230922","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1682\/JRRD.2004.10.0130","article-title":"Issues in maintenance and repairs of wheelchairs: a pilot study","volume":"42","year":"2005","journal-title":"J Rehabil Res Dev"}],"container-title":["American Journal of Physical Medicine &amp; Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PHM.0000000000001245","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T19:46:07Z","timestamp":1695411967000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PHM.0000000000001245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,14]]},"references-count":19,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/phm.0000000000001245","relation":{},"ISSN":["1537-7385","0894-9115"],"issn-type":[{"value":"1537-7385","type":"electronic"},{"value":"0894-9115","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6,14]]}}}