{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T15:57:46Z","timestamp":1765382266904,"version":"3.41.0"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Am J Phys Med Rehabil"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The aims of the study were to reliably determine the two main phases of manual wheelchair propulsion via a simple wearable sensor and to evaluate the effects of modulated trunk and hip stimulation on manual wheelchair propulsion during the challenging tasks of ramp assent and level sprint.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design<\/jats:title>\n            <jats:p>An offline tool was created to identify common features between wrist acceleration signals for all subjects who corresponded to the transitions between the contact and recovery phases of manual wheelchair propulsion. For one individual, the acceleration rules and thresholds were implemented for real-time phase-change event detection and modulation of stimulation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>When pushing with phase-dependent modulated stimulation, there was a significant (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05) increase in the primary speed variable (5%\u20136%) and the subject rated pushing as \u201cmoderately or very easy.\u201d In the offline analysis, the average phase-change event detection success rate was 79% at the end of contact and 71% at the end of recovery across the group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Signals from simple, wrist-mounted accelerometers can detect the phase transitions during manual wheelchair propulsion instead of elaborate and expensive, instrumented systems. Appropriately timing changes in muscle activation with the propulsion cycle can result in a significant increase in speed, and the system was consistently perceived to be significantly easier to use.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/phm.0000000000001691","type":"journal-article","created":{"date-parts":[[2021,1,14]],"date-time":"2021-01-14T17:15:00Z","timestamp":1610644500000},"page":"983-989","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Effect of Context-Dependent Modulation of Trunk Muscle Activity on Manual Wheelchair Propulsion"],"prefix":"10.1097","volume":"100","author":[{"given":"Stephanie Nogan","family":"Bailey","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin M.","family":"Foglyano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas F.","family":"Bean","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald J.","family":"Triolo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,1,12]]},"reference":[{"key":"bib1-20250616","first-page":"128","article-title":"Effect of wearing an activity monitor on the amount of daily manual wheelchair propulsion in persons with spinal cord injury","volume":"48","year":"2009","journal-title":"Spinal Cord"},{"key":"bib2-20250616","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.apmr.2017.12.015","article-title":"Agreement of musculoskeletal ultrasound and clinical assessment of shoulder impairment in manual wheelchair users with various duration of spinal cord injury","volume":"99","year":"2018","journal-title":"Arch Phys Med Rehabil"},{"key":"bib3-20250616","doi-asserted-by":"crossref","first-page":"2086","DOI":"10.1016\/j.apmr.2008.05.015","article-title":"Shoulder ultrasound abnormalities, physical examination findings, and pain in manual wheelchair users with spinal cord injury","volume":"89","year":"2008","journal-title":"Arch Phys Med Rehabil"},{"key":"bib4-20250616","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1038\/s41393-017-0029-z","article-title":"Prevalence and factors associated with a higher risk of neck and back pain among permanent wheelchair users: a cross-sectional study","volume":"56","year":"2018","journal-title":"Spinal Cord"},{"key":"bib5-20250616","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/1743-0003-12-8","article-title":"A neuroprosthesis for control of seated balance after spinal cord injury","volume":"12","year":"2015","journal-title":"J Neuroeng Rehabil"},{"key":"bib6-20250616","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1682\/JRRD.2013.09.0200","article-title":"Feasibility of closed-loop controller for righting seated posture after spinal cord injury","volume":"51","year":"2014","journal-title":"J Rehabil Res Dev"},{"key":"bib7-20250616","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s12984-018-0362-2","article-title":"Automatic application of neural stimulation during wheelchair propulsion after SCI enhances recovery of upright sitting from destabilizing events","volume":"15","year":"2018","journal-title":"J Neuroeng Rehabil"},{"key":"bib8-20250616","doi-asserted-by":"crossref","first-page":"1766","DOI":"10.1016\/j.apmr.2013.02.023","article-title":"Effects of stimulating hip and trunk muscles on seated stability, posture, and reach after spinal cord injury","volume":"94","year":"2013","journal-title":"Arch Phys Med Rehabil"},{"key":"bib9-20250616","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.apmr.2008.07.029","article-title":"Implanted electrical stimulation of the trunk for seated postural stability and function after cervical spinal cord injury: a single case study","volume":"90","year":"2009","journal-title":"Arch Phys Med Rehabil"},{"key":"bib10-20250616","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1016\/j.apmr.2013.04.010","article-title":"Effects of intramuscular trunk stimulation on manual wheelchair propulsion mechanics in 6 subjects with spinal cord injury","volume":"94","year":"2013","journal-title":"Arch Phys Med Rehabil"},{"key":"bib11-20250616","doi-asserted-by":"crossref","first-page":"2487","DOI":"10.1016\/j.jbiomech.2010.05.026","article-title":"Shoulder model validation and joint contact forces during wheelchair activities","volume":"43","year":"2010","journal-title":"J Biomech"},{"key":"bib12-20250616","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.apmr.2007.08.141","article-title":"Preliminary outcomes of the SmartWheel users\u2019 group database: a proposed framework for clinicians to objectively evaluate manual wheelchair propulsion","volume":"89","year":"2008","journal-title":"Arch Phys Med Rehabil"},{"key":"bib13-20250616","first-page":"277","article-title":"Shoulder kinetics and ultrasonography changes after performing a high-intensity task in spinal cord injury subjects and healthy controls","volume":"54","year":"2015","journal-title":"Spinal Cord"},{"key":"bib14-20250616","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1097\/PHM.0b013e31818a52cc","article-title":"Influence of varying level terrain on wheelchair propulsion biomechanics","volume":"87","year":"2008","journal-title":"Am J Phys Med Rehabil"},{"key":"bib15-20250616","first-page":"3167","article-title":"Street rehab: linking accessibility and rehabilitation","volume":"8","year":"2016","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"bib16-20250616","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.medengphy.2015.12.011","article-title":"A novel algorithm for detecting active propulsion in wheelchair users following spinal cord injury","volume":"38","year":"2016","journal-title":"Med Eng Phys"},{"journal-title":"BodyNets","article-title":"Classifying wheelchair propulsion patterns with a wrist mounted accelerometer","year":"2008","key":"bib17-20250616"},{"key":"bib19-20250616","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.medengphy.2014.10.009","article-title":"Detection of physical activities using a physical activity monitor system for wheelchair users","volume":"37","year":"2015","journal-title":"Med Eng Phys"},{"key":"bib20-20250616","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1038\/sc.2015.81","article-title":"Identifying physical activity type in manual wheelchair users with spinal cord injury by means of accelerometers","volume":"53","year":"2015","journal-title":"Spinal Cord"},{"key":"bib21-20250616","doi-asserted-by":"crossref","first-page":"2472","DOI":"10.1109\/TNSRE.2017.2727072","article-title":"Wheelchair neuroprosthesis for improving dynamic trunk stability","volume":"25","year":"2017","journal-title":"IEEE T Neur Sys Reh"},{"key":"bib22-20250616","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1310\/sci2302-168","article-title":"Shoulder functional electrical stimulation during wheelchair propulsion in spinal cord injury subjects","volume":"23","year":"2017","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"bib23-20250616","first-page":"499","article-title":"An externally powered, multichannel implantable stimulator for versatile control of paralyzed muscle","volume":"34","year":"1987","journal-title":"IEEE Trans Biomed Eng"},{"key":"bib24-20250616","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1109\/10.664202","article-title":"An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle","volume":"45","year":"1998","journal-title":"IEEE Trans Biomed Eng"},{"key":"bib25-20250616","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/1743-0003-9-25","article-title":"Comparing joint kinematics and center of mass acceleration for feedback control of standing by functional neuromuscular stimulation","volume":"9","year":"2012","journal-title":"J Neuroeng Rehabil"},{"key":"bib26-20250616","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/1743-0003-10-25","article-title":"Optimization of selective stimulation parameters for multi-contact electrodes","volume":"10","year":"2013","journal-title":"J Neuroeng Rehabil"},{"key":"bib27-20250616","first-page":"80","article-title":"A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system","volume":"2","year":"1994","journal-title":"IEEE Trans Biomed Eng"},{"key":"bib28-20250616","first-page":"237","article-title":"Surgical technique for installing an 8-channel neuroprosthesis for standing","volume":"4","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"bib29-20250616","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1109\/86.593301","article-title":"Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes","volume":"5","year":"1997","journal-title":"IEEE Trans Rehabil Eng"},{"key":"bib30-20250616","first-page":"279","article-title":"Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury","volume":"12","year":"2004","journal-title":"IEEE Trans Rehabil Eng"},{"key":"bib31-20250616","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.apmr.2008.07.013","article-title":"Redefining manual wheelchair stroke cycle: identification and impact of nonpropulsive pushrim contact","volume":"90","year":"2009","journal-title":"Arch Phys Med Rehabil"},{"key":"bib32-20250616","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/00002060-199805000-00006","article-title":"Effectiveness of force application in manual wheelchair propulsion in persons with spinal cord injuries","volume":"77","year":"1998","journal-title":"Am J Phys Med Rehabil"},{"key":"bib33-20250616","doi-asserted-by":"crossref","first-page":"2771","DOI":"10.1016\/j.jbiomech.2010.06.020","article-title":"The influence of altering push force effectiveness on upper extremity demand during wheelchair propulsion","volume":"43","year":"2010","journal-title":"J Biomech"},{"key":"bib35-20250616","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1177\/1545968308331145","article-title":"Biomechanical analysis of surface electrical stimulation on the trunk musculature during wheelchair propulsion","volume":"23","year":"2009","journal-title":"Neurorehabil Neural Repair"},{"key":"bib36-20250616","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.apmr.2006.09.017","article-title":"Stroke pattern and handrim biomechanics for level and uphill wheelchair propulsion at self-selected speeds","volume":"88","year":"2007","journal-title":"Arch Phys Med Rehabil"},{"key":"bib37-20250616","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.apmr.2013.06.028","article-title":"Impact of a wheelchair education protocol based on practice guidelines for preservation of upper-limb function: a randomized trial","volume":"95","year":"2014","journal-title":"Arch Phys Med Rehabil"},{"key":"bib38-20250616","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.apmr.2010.11.001","article-title":"Effects of single-variable biofeedback on wheelchair handrim biomechanics","volume":"92","year":"2011","journal-title":"Arch Phys Med Rehabil"},{"key":"bib39-20250616","first-page":"47","article-title":"A systematic review: the influence of real time feedback on wheelchair propulsion biomechanics","volume":"13","year":"2017","journal-title":"Disabil Rehabil Assist Technol"}],"container-title":["American Journal of Physical Medicine &amp; Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PHM.0000000000001691","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T21:12:06Z","timestamp":1750108326000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PHM.0000000000001691"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,12]]},"references-count":37,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/phm.0000000000001691","relation":{},"ISSN":["1537-7385","0894-9115"],"issn-type":[{"type":"electronic","value":"1537-7385"},{"type":"print","value":"0894-9115"}],"subject":[],"published":{"date-parts":[[2021,1,12]]}}}