{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T07:59:28Z","timestamp":1794038368446,"version":"4.8.0"},"reference-count":75,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Tendon-related complications after plate fixation of distal radius fractures can cause significant morbidity in the patient. This retrospective systematic review aims to report and compare the current rate of tendon rupture and tenosynovitis complicating the operative management of distal radius fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A systematic literature search was performed to identify relevant articles reporting tendon complications after operative management of distal radius fractures. The search included published articles in three electronic databases\u2014Ovid MEDLINE, EMBASE, and the Cochrane Library\u2014starting from the establishment of each database to February of 2016.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 56 studies met the inclusion criteria, including 6278 patients. Overall tendon-related adverse events were reported in 420 patients (6.8 percent). The incidence of tendon rupture was 1.5 percent with volar plates and 1.7 percent with dorsal plates. The incidence of tenosynovitis was 4.5 percent with volar plates and 7.5 percent with dorsal plates. Individual tendon complications were reported with volar and dorsal fixation, respectively: extensor pollicis longus tenosynovitis (0.3 percent and 1.1 percent), extensor pollicis longus rupture (0.8 percent and 0.3 percent), flexor pollicis longus tenosynovitis (1.3 percent and 0 percent), flexor pollicis longus rupture (0.6 percent and 0.2 percent), flexor digitorum profundus\/flexor digitorum superficialis tenosynovitis (1.2 percent and 1.3 percent), flexor digitorum profundus\/flexor digitorum superficialis rupture (0.1 percent and 0 percent), extensor digitorum communis tenosynovitis (1.7 percent and 5.9 percent), and extensor digitorum communis rupture (0.05 percent and 1.3 percent).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This systematic review provides an update on the literature regarding tendon-related complications in the management of distal radius fractures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/prs.0000000000003076","type":"journal-article","created":{"date-parts":[[2017,2,25]],"date-time":"2017-02-25T17:22:19Z","timestamp":1488043339000},"page":"717e-724e","source":"Crossref","is-referenced-by-count":63,"title":["Tendon Rupture and Tenosynovitis following Internal Fixation of Distal Radius Fractures: A Systematic Review"],"prefix":"10.1097","volume":"139","author":[{"given":"Alain J.","family":"Azzi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salah","family":"Aldekhayel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaitlin S.","family":"Boehm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teanoosh","family":"Zadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230715","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: A review.","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury"},{"key":"R2-20230715","first-page":"182","article-title":"On the fracture of the carpal extremity of the radius.","volume":"10","author":"Colles","year":"1814","journal-title":"Edinburgh Med Surg J"},{"key":"R3-20230715","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.","volume":"21","author":"Arora","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R4-20230715","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius.","volume":"31","author":"Rozental","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R5-20230715","doi-asserted-by":"crossref","first-page":"22","DOI":"10.3944\/AOTT.2012.2623","article-title":"Results of volar locking plating for unstable distal radius fractures.","volume":"46","author":"S\u00fcg\u00fcn","year":"2012","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R6-20230715","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1016\/j.jhsa.2012.06.041","article-title":"Incidence and clinical outcomes of tendon rupture following distal radius fracture.","volume":"37","author":"White","year":"2012","journal-title":"J Hand Surg Am"},{"key":"R7-20230715","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1177\/1753193410392869","article-title":"Screw prominences related to palmar locking plating of distal radius.","volume":"36","author":"S\u00fcg\u00fcn","year":"2011","journal-title":"J Hand Surg Eur Vol"},{"key":"R8-20230715","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1302\/0301-620X.80B2.0800225","article-title":"Rupture of flexor pollicis longus tendon: A complication of volar plating of the distal radius.","volume":"80","author":"Bell","year":"1998","journal-title":"J Bone Joint Surg Br"},{"key":"R9-20230715","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.jhsa.2010.09.033","article-title":"Fracture of the distal radius: Risk factors for complications after locked volar plate fixation.","volume":"36","author":"Soong","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R10-20230715","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1302\/0301-620X.88B12.17696","article-title":"Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.","volume":"88","author":"Al-Rashid","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"R11-20230715","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/BOT.0b013e3182539333","article-title":"The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures.","volume":"27","author":"Hershman","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R12-20230715","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/j.jhsa.2011.04.004","article-title":"Complications of low-profile dorsal versus volar locking plates in the distal radius: A comparative study.","volume":"36","author":"Yu","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R13-20230715","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1142\/S0218810411005539","article-title":"Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures.","volume":"16","author":"Tada","year":"2011","journal-title":"Hand Surg"},{"key":"R14-20230715","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1007\/s00402-013-1766-x","article-title":"Complications following palmar plate fixation of distal radius fractures: A review of 665 cases.","volume":"133","author":"Esenwein","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R15-20230715","first-page":"714","article-title":"Complications of volar plating of distal radius fractures.","volume":"73","author":"Rampoldi","year":"2007","journal-title":"Acta Orthop Belg"},{"key":"R16-20230715","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jhsa.2005.09.011","article-title":"Volar versus dorsal plating in the management of intra-articular distal radius fractures.","volume":"31","author":"Ruch","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R17-20230715","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.jhsa.2014.11.022","article-title":"Incidence and reasons for hardware removal following operative fixation of distal radius fractures.","volume":"40","author":"Snoddy","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R18-20230715","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","article-title":"A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: Analysis of 40 cases.","volume":"15","author":"Tarallo","year":"2014","journal-title":"J Orthop Traumatol"},{"key":"R19-20230715","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s10195-014-0306-y","article-title":"Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures.","volume":"15","author":"Wichlas","year":"2014","journal-title":"J Orthop Traumatol"},{"key":"R20-20230715","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1007\/s00264-014-2382-2","article-title":"Intramedullary repair device against volar plating in the reconstruction of extra-articular and simple articular distal radius fractures; a randomized pilot study.","volume":"38","author":"Zehir","year":"2014","journal-title":"Int Orthop"},{"key":"R21-20230715","doi-asserted-by":"crossref","first-page":"e978","DOI":"10.3928\/01477447-20141023-54","article-title":"Hardware-related complications after dorsal plating for displaced distal radius fractures.","volume":"37","author":"Matzon","year":"2014","journal-title":"Orthopedics"},{"key":"R22-20230715","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1007\/s00590-013-1363-2","article-title":"Distal radius fixation through a mini-invasive approach of 15 mm: Part 1. A series of 144 cases.","volume":"24","author":"Lebailly","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R23-20230715","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.injury.2013.10.003","article-title":"Complications after volar locking plate fixation of distal radius fractures.","volume":"45","author":"Johnson","year":"2014","journal-title":"Injury"},{"key":"R24-20230715","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1007\/s00402-013-1698-5","article-title":"Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius.","volume":"133","author":"Gradl","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R25-20230715","doi-asserted-by":"crossref","first-page":"399","DOI":"10.4103\/0019-5413.136275","article-title":"Results of pronator quadratus repair in distal radius fractures to prevent tendon ruptures.","volume":"48","author":"Tahririan","year":"2014","journal-title":"Indian J Orthop"},{"key":"R26-20230715","doi-asserted-by":"crossref","first-page":"131757","DOI":"10.1155\/2013\/131757","article-title":"Dorsally comminuted fractures of the distal end of the radius: Osteosynthesis with volar fixed angle locking plates.","volume":"2013","author":"Gogna","year":"2013","journal-title":"ISRN Orthop"},{"key":"R27-20230715","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1097\/BOT.0b013e3182913fc5","article-title":"Volar plate fixation for the treatment of distal radius fractures: Analysis of adverse events.","volume":"27","author":"Tarallo","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R28-20230715","doi-asserted-by":"crossref","first-page":"2198","DOI":"10.1016\/j.jhsa.2013.08.116","article-title":"Prospective evaluation of distal radius fractures treated with variable-angle volar locking plates.","volume":"38","author":"Fowler","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R29-20230715","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1016\/j.jhsa.2013.06.006","article-title":"Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures.","volume":"38","author":"Tosti","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R30-20230715","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.main.2012.11.001","article-title":"Prospective continuous study comparing intrafocal cross-pinning HK2 with a locking plate in distal radius fracture fixation.","volume":"32","author":"Maire","year":"2013","journal-title":"Chir Main"},{"key":"R31-20230715","doi-asserted-by":"crossref","first-page":"e282","DOI":"10.3928\/01477447-20110526-10","article-title":"Long-term results of dorsally displaced distal radius fractures treated with the pi-plate: Is hardware removal necessary?","volume":"34","author":"Tyllianakis","year":"2011","journal-title":"Orthopedics"},{"key":"R32-20230715","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/j.jhsa.2011.02.024","article-title":"Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures.","volume":"36","author":"Chou","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R33-20230715","first-page":"1510","article-title":"Results of volar locking plate osteosynthesis for distal radial fractures.","volume":"70","author":"Lattmann","year":"2011","journal-title":"J Trauma"},{"key":"R34-20230715","doi-asserted-by":"crossref","first-page":"328","DOI":"10.2106\/JBJS.J.00193","article-title":"Volar locking plate implant prominence and flexor tendon rupture.","volume":"93","author":"Soong","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"R35-20230715","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1177\/1753193409106178","article-title":"Open reduction and plate fixation of dorsally displaced fractures of the distal radius: Surgical technique, clinical and radiological outcome.","volume":"35","author":"Hems","year":"2010","journal-title":"J Hand Surg Eur Vol"},{"key":"R36-20230715","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1007\/s00402-010-1045-z","article-title":"Palmar multidirectional fixed-angle plate fixation in distal radius fractures: Do intraarticular fractures have a worse outcome than extraarticular fractures?","volume":"130","author":"Sonderegger","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"key":"R37-20230715","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s00402-009-0990-x","article-title":"Clinical and radiological outcomes after stabilisation of complex intra-articular fractures of the distal radius with the volar 2.4 mm LCP.","volume":"130","author":"Konstantinidis","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"key":"R38-20230715","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.injury.2009.08.024","article-title":"Locked volar plating for unstable distal radial fractures: Clinical and radiological outcomes.","volume":"41","author":"Knight","year":"2010","journal-title":"Injury"},{"key":"R39-20230715","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/BOT.0b013e31819b24e9","article-title":"A comparative study of clinical and radiologic outcomes of unstable Colles type distal radius fractures in patients older than 70 years: Nonoperative treatment versus volar locking plating.","volume":"23","author":"Arora","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R40-20230715","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.jhsa.2008.01.024","article-title":"Prospective study of distal radius fractures treated with a volar locking plate system.","volume":"33","author":"Osada","year":"2008","journal-title":"J Hand Surg Am"},{"key":"R41-20230715","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/J.JHSB.2006.08.007","article-title":"Dorsal (AO\/ASIF) pi-plate osteosynthesis in the treatment of distal intraarticular radius fractures.","volume":"31","author":"Suckel","year":"2006","journal-title":"J Hand Surg Br"},{"key":"R42-20230715","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1016\/j.jhsa.2006.05.008","article-title":"Low-profile dorsal plating for dorsally angulated distal radius fractures: An outcomes study.","volume":"31","author":"Kamath","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R43-20230715","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.jhsa.2005.10.016","article-title":"Treatment of distal radius fractures with a low-profile dorsal plating system: An outcomes assessment.","volume":"31","author":"Simic","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R44-20230715","first-page":"672","article-title":"Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate.","volume":"71","author":"Khanduja","year":"2005","journal-title":"Acta Orthop Belg"},{"key":"R45-20230715","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/01.PRS.0000169713.49004.7B","article-title":"Complications after Pi Plate osteosynthesis.","volume":"116","author":"S\u00e1nchez","year":"2005","journal-title":"Plast Reconstr Surg"},{"key":"R46-20230715","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1142\/S0218810403001339","article-title":"Fixation of distal radius fractures using AO titanium volar distal radius plate.","volume":"8","author":"Lee","year":"2003","journal-title":"Hand Surg"},{"key":"R47-20230715","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/S0020-1383(02)00190-0","article-title":"Dorsal plating for displaced intra-articular fractures of the distal radius.","volume":"34","author":"Herron","year":"2003","journal-title":"Injury"},{"key":"R48-20230715","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/00003086-200204000-00047","article-title":"Palmar plating for dorsally displaced fractures of the distal radius.","volume":"397","author":"Kamano","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"R49-20230715","doi-asserted-by":"crossref","first-page":"125","DOI":"10.3928\/0147-7447-20020201-15","article-title":"Volar neutralization plate fixation of dorsally displaced distal radius fractures.","volume":"25","author":"Constantine","year":"2002","journal-title":"Orthopedics"},{"key":"R50-20230715","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1054\/jhsb.2000.0485","article-title":"Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate.","volume":"25","author":"Campbell","year":"2000","journal-title":"J Hand Surg Br"},{"key":"R51-20230715","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.injury.2010.10.010","article-title":"Comparison of angle stable plate fixation approaches for distal radius fractures.","volume":"42","author":"Matschke","year":"2011","journal-title":"Injury"},{"key":"R52-20230715","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1177\/230949900501300208","article-title":"Volar fixation of dorsally displaced distal radial fracture using locking compression plate.","volume":"13","author":"Wong","year":"2005","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R53-20230715","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00264-002-0393-x","article-title":"Osteosynthesis of distal radial fractures with a volar locking screw plate system.","volume":"27","author":"Drobetz","year":"2003","journal-title":"Int Orthop"},{"key":"R54-20230715","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1053\/jhsu.2002.32081","article-title":"Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report.","volume":"27","author":"Orbay","year":"2002","journal-title":"J Hand Surg Am"},{"key":"R55-20230715","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1177\/1753193408094706","article-title":"A randomised clinical study comparing palmar and dorsal fixed-angle plates for the internal fixation of AO C-type fractures of the distal radius in the elderly.","volume":"33","author":"Jakubietz","year":"2008","journal-title":"J Hand Surg Eur Vol"},{"key":"R56-20230715","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/1749-799X-7-8","article-title":"Palmar and dorsal fixed-angle plates in AO C-type fractures of the distal radius: Is there an advantage of palmar plates in the long term?","volume":"7","author":"Jakubietz","year":"2012","journal-title":"J Orthop Surg Res"},{"key":"R57-20230715","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.jhsa.2007.05.008","article-title":"Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study.","volume":"32","author":"Rein","year":"2007","journal-title":"J Hand Surg Am"},{"key":"R58-20230715","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.otsr.2010.11.011","article-title":"Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.","volume":"97","author":"Chappuis","year":"2011","journal-title":"Orthop Traumatol Surg Res"},{"key":"R59-20230715","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1749-799X-7-4","article-title":"Mid-term functional outcome after the internal fixation of distal radius fractures.","volume":"7","author":"Phadnis","year":"2012","journal-title":"J Orthop Surg Res"},{"key":"R60-20230715","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1302\/0301-620X.90B9.20521","article-title":"Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: A randomised, prospective trial.","volume":"90","author":"Egol","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"R61-20230715","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.2106\/JBJS.L.00232","article-title":"Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: A randomized controlled trial.","volume":"95","author":"Karantana","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R62-20230715","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.ijsu.2010.02.007","article-title":"Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement.","volume":"8","author":"Moher","year":"2010","journal-title":"Int J Surg"},{"key":"R63-20230715","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.injury.2013.01.008","article-title":"Complications of distal radius locking plates.","volume":"44","author":"Toros","year":"2013","journal-title":"Injury"},{"key":"R64-20230715","doi-asserted-by":"crossref","first-page":"369","DOI":"10.5435\/00124635-200906000-00005","article-title":"Complications of volar plate fixation for managing distal radius fractures.","volume":"17","author":"Berglund","year":"2009","journal-title":"J Am Acad Orthop Surg"},{"key":"R65-20230715","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/S0072-968X(79)80015-7","article-title":"Rupture of the extensor pollicis longus tendon after fracture of the lower end of the radius: A clinical and microangiographic study.","volume":"11","author":"Engkvist","year":"1979","journal-title":"Hand"},{"key":"R66-20230715","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/01.blo.0000223998.02765.0d","article-title":"Two potential causes of EPL rupture after distal radius volar plate fixation.","volume":"451","author":"Benson","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R67-20230715","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.2106\/00004623-200310000-00014","article-title":"Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius.","volume":"85","author":"Rozental","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R68-20230715","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1097\/00000637-200044050-00016","article-title":"Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO\/ASIF titanium pi plate. Arbeitsgemeinschaft f\u00fcr Osteosynthesefragen\/Association for the Study of Internal Fixation.","volume":"44","author":"Schnur","year":"2000","journal-title":"Ann Plast Surg"},{"key":"R69-20230715","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.hcl.2005.02.001","article-title":"Dorsal plating for distal radius fractures.","volume":"21","author":"Tavakolian","year":"2005","journal-title":"Hand Clin"},{"key":"R70-20230715","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1177\/0300060513476438","article-title":"Complications following dorsal versus volar plate fixation of distal radius fracture: A meta-analysis.","volume":"41","author":"Wei","year":"2013","journal-title":"J Int Med Res"},{"key":"R71-20230715","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s11552-010-9316-2","article-title":"Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.","volume":"6","author":"Ozer","year":"2011","journal-title":"Hand (N Y)"},{"key":"R72-20230715","doi-asserted-by":"crossref","first-page":"e408","DOI":"10.1097\/BOT.0000000000000361","article-title":"Dorsal screw penetration with the use of volar plating of distal radius fractures: How can you best detect?","volume":"29","author":"Hill","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R73-20230715","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jhsa.2011.12.013","article-title":"The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.","volume":"37","author":"Wall","year":"2012","journal-title":"J Hand Surg Am"},{"key":"R74-20230715","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1016\/j.jhsa.2014.03.038","article-title":"Complications after volar plating of distal radius fractures.","volume":"39","author":"Griffin","year":"2014","journal-title":"J Hand Surg Am"},{"key":"R75-20230715","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1177\/1753193412453436","article-title":"How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicis longus tendon: A biomechanical investigation.","volume":"38","author":"Matityahu","year":"2013","journal-title":"J Hand Surg Eur Vol"}],"container-title":["Plastic &amp; Reconstructive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00006534-201703000-00035","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,15]],"date-time":"2023-07-15T01:14:36Z","timestamp":1689383676000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00006534-201703000-00035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3]]},"references-count":75,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/prs.0000000000003076","relation":{},"ISSN":["0032-1052"],"issn-type":[{"value":"0032-1052","type":"print"}],"subject":[],"published":{"date-parts":[[2017,3]]}}}