{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T04:36:25Z","timestamp":1772253385609,"version":"3.50.1"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:sec>\n            <jats:title>Summary:<\/jats:title>\n            <jats:p>Synthetic mesh is commonly used in ventral hernia repairs to reinforce the abdominal closure and minimize hernia recurrence rates. However, the use of synthetic mesh is associated with certain risks, most notably infection requiring explantation. This study sought to evaluate the use of a \u201cno-touch\u201d technique with antibiotic solution during synthetic mesh placement in ventral hernia repairs and its impact on complication\/infection rates. The authors retrospectively reviewed a prospectively maintained database of patients undergoing abdominal wall reconstruction with synthetic mesh from 2013 to 2018 by a single surgeon with a minimum 1-year follow-up. Data collected included demographic data, medical comorbidities, hernia history, and the type of antibiotics used in the no-touch technique. Complications were stratified into short-term (&lt;30 days), medium-term (30 to 90 days), and long-term (91 to 365 days) complications. Results were compared to previously published rates in the literature. Eighty-eight patients met inclusion criteria. Fourteen patients (15.9 percent) experienced postoperative complications (two patients had multiple complications); six of these patients (6.8 percent) were readmitted to the hospital for management. Subsequently, three of the readmitted patients (3.4 percent) required reoperations related to abdominal infection and required removal of the synthetic mesh. A total of 16 complication events occurred in the cohort: 13 short-term complications (81.3 percent), three medium-term complications (18.7 percent), and zero long-term complications. The authors conclude that the no-touch technique for mesh placement in ventral hernia repairs appears to be efficacious in minimizing infectious complications with mesh placement, although further prospective studies are required to further define this relationship.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CLINICAL QUESTION\/LEVEL OF EVIDENCE:<\/jats:title>\n            <jats:p>Therapeutic, IV.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/prs.0000000000006767","type":"journal-article","created":{"date-parts":[[2020,4,25]],"date-time":"2020-04-25T06:10:09Z","timestamp":1587795009000},"page":"1288-1291","source":"Crossref","is-referenced-by-count":18,"title":["No-Touch Technique of Mesh Placement in Ventral Hernia Repair: Minimizing Postoperative Mesh Infections"],"prefix":"10.1097","volume":"145","author":[{"given":"Steven J.","family":"Schneeberger","sequence":"first","affiliation":[{"name":"From the Department of Plastic Surgery, The Ohio State University Wexner Medical Center."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Casey T.","family":"Kraft","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, The Ohio State University Wexner Medical Center."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey E.","family":"Janis","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, The Ohio State University Wexner Medical Center."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230801","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s10029-011-0879-9","article-title":"Epidemiology and cost of ventral hernia repair: Making the case for hernia research.","volume":"16","author":"Poulose","year":"2012","journal-title":"Hernia"},{"key":"R2-20230801","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1097\/PRS.0000000000001831","article-title":"Evidence-based abdominal wall reconstruction: The maxi-mini approach.","volume":"136","author":"Janis","year":"2015","journal-title":"Plast Reconstr Surg"},{"key":"R5-20230801","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1056\/NEJM200008103430603","article-title":"A comparison of suture repair with mesh repair for incisional hernia.","volume":"343","author":"Luijendijk","year":"2000","journal-title":"N Engl J Med"},{"key":"R6-20230801","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1097\/00000658-198108000-00017","article-title":"Emergency abdominal wall reconstruction with polypropylene mesh: Short-term benefits versus long-term complications.","volume":"194","author":"Voyles","year":"1981","journal-title":"Ann Surg"},{"key":"R7-20230801","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1001\/archsurg.133.4.378","article-title":"Long-term complications associated with prosthetic repair of incisional hernias.","volume":"133","author":"Leber","year":"1998","journal-title":"Arch Surg"},{"key":"R8-20230801","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/01.prs.0000475775.44891.56","article-title":"A cost-utility assessment of mesh selection in clean-contaminated ventral hernia repair.","volume":"137","author":"Fischer","year":"2016","journal-title":"Plast Reconstr Surg"},{"key":"R9-20230801","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1001\/jama.2016.15217","article-title":"Long-term recurrence and complications associated with elective incisional hernia repair.","volume":"316","author":"Kokotovic","year":"2016","journal-title":"JAMA"},{"key":"R10-20230801","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.jamcollsurg.2018.10.009","article-title":"Cost-utility analysis of biologic and biosynthetic mesh in ventral hernia repair: When are they worth it?","volume":"228","author":"Schneeberger","year":"2019","journal-title":"J Am Coll Surg"},{"key":"R11-20230801","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1016\/j.surg.2010.01.008","article-title":"Incisional ventral hernias: Review of the literature and recommendations regarding the grading and technique of repair.","volume":"148","author":"Breuing","year":"2010","journal-title":"Surgery"},{"key":"R12-20230801","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1136\/bmj.2.4265.388","article-title":"The non-touch technique.","volume":"4265","author":"Fairbank","year":"1942","journal-title":"BMJ"},{"key":"R13-20230801","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1302\/0301-620X.34B3.478","article-title":"Sir William Arbuthnot Lane.","volume":"34","author":"Jones","year":"1952","journal-title":"J Bone Joint Surg Br"},{"key":"R14-20230801","doi-asserted-by":"crossref","first-page":"237","DOI":"10.3109\/02688699209002932","article-title":"New instrumentation for the assembly of shunt systems by a non-touch technique.","volume":"6","author":"Ashpole","year":"1992","journal-title":"Br J Neurosurg"},{"key":"R15-20230801","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/0090-3019(95)80060-T","article-title":"A no-touch technique protocol to diminish cerebrospinal fluid shunt infection.","volume":"43","author":"Faillace","year":"1995","journal-title":"Surg Neurol"},{"key":"R16-20230801","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1159\/000075255","article-title":"Reflections on shunt infection.","volume":"39","author":"Kanev","year":"2003","journal-title":"Pediatr Neurosurg"},{"key":"R17-20230801","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/BF00636260","article-title":"\u201cNo-touch\u201d submuscular saline breast augmentation technique.","volume":"17","author":"Mladick","year":"1993","journal-title":"Aesthetic Plast Surg"},{"key":"R18-20230801","doi-asserted-by":"crossref","first-page":"1892","DOI":"10.1097\/PRS.0b013e31818d20ec","article-title":"The process of breast augmentation: Four sequential steps for optimizing outcomes for patients.","volume":"122","author":"Adams","year":"2008","journal-title":"Plast Reconstr Surg"},{"key":"R19-20230801","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1097\/00006534-200201000-00044","article-title":"Achieving a predictable 24-hour return to normal activities after breast augmentation: Part I. Refining practices by using motion and time study principles.","volume":"109","author":"Tebbetts","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"R20-20230801","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.urology.2011.11.076","article-title":"Coated implants and \u201cno touch\u201d surgical technique decreases risk of infection in inflatable penile prosthesis implantation to 0.46%.","volume":"79","author":"Eid","year":"2012","journal-title":"Urology"},{"key":"R21-20230801","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1111\/j.1743-6109.2010.02137.x","article-title":"Surgical techniques: No-touch technique.","volume":"8","author":"Eid","year":"2011","journal-title":"J Sex Med"},{"key":"R22-20230801","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.sxmr.2016.01.002","article-title":"Penile implant: Review of a \u201cno-touch\u201d technique.","volume":"4","author":"Eid","year":"2016","journal-title":"Sex Med Rev"},{"key":"R23-20230801","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/BF00636260","article-title":"\u201cNo-touch\u201d submuscular saline breast augmentation technique.","volume":"17","author":"Mladick","year":"1993","journal-title":"Aesthetic Plast Surg"},{"key":"R24-20230801","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1097\/00000637-198904000-00009","article-title":"Adherence of microorganisms to breast prostheses: An in vitro study.","volume":"22","author":"Sanger","year":"1989","journal-title":"Ann Plast Surg"},{"key":"R25-20230801","doi-asserted-by":"crossref","first-page":"e1868","DOI":"10.1097\/GOX.0000000000001868","article-title":"The role of antibiotics in breast pocket irrigation and implant immersion.","volume":"6","author":"Frois","year":"2018","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R26-20230801","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1097\/PRS.0000000000003575","article-title":"Macrotextured breast implants with defined steps to minimize bacterial contamination around the device: Experience in 42,000 implants.","volume":"140","author":"Adams","year":"2017","journal-title":"Plast Reconstr Surg"},{"issue":"Suppl","key":"R27-20230801","doi-asserted-by":"crossref","first-page":"46S","DOI":"10.1097\/01.prs.0000185671.51993.7e","article-title":"Enhancing patient outcomes in aesthetic and reconstructive breast surgery using triple antibiotic breast irrigation: Six-year prospective clinical study.","volume":"118","author":"Adams","year":"2006","journal-title":"Plast Reconstr Surg"},{"key":"R28-20230801","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/00006534-200001000-00053","article-title":"Optimizing breast pocket irrigation: An in vitro study and clinical implications.","volume":"105","author":"Adams","year":"2000","journal-title":"Plast Reconstr Surg"},{"key":"R29-20230801","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.jamcollsurg.2012.08.012","article-title":"Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs.","volume":"215","author":"Kanters","year":"2012","journal-title":"J Am Coll Surg"}],"container-title":["Plastic &amp; Reconstructive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000006767","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T19:40:25Z","timestamp":1690918825000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000006767"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/prs.0000000000006767","relation":{},"ISSN":["0032-1052"],"issn-type":[{"value":"0032-1052","type":"print"}],"subject":[],"published":{"date-parts":[[2020,5]]}}}