{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T16:59:43Z","timestamp":1783443583947,"version":"3.54.6"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Despite the popularity and superiority of resorbable alloplastic materials in orbital fracture reconstruction, it is unclear whether the reconstructed wall is maintained after implant resorption. Unsintered hydroxyapatite\/poly-L-lactide (u-HA\/PLLA) is one such material, but it differs from conventional materials for the replacement of natural bones. This study investigated the intermediate-term safety and efficacy of u-HA\/PLLA implants compared with those of implants made with other alloplastic materials.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The authors retrospectively analyzed 240 eligible patients who underwent orbital fracture reconstruction with one alloplastic material between January of 2006 and October of 2018. Materials used for treatment were as follows: u-HA\/PLLA sheet in 101 patients, u-HA\/PLLA mesh in 38 patients, poly-L-lactic acid\/poly-glycolic acid mesh in 47 patients, silicone sheet in 35 patients, and titanium mesh in 19 patients. Intermediate-term follow-up was performed for a median duration of 48.2 months. A chart review was performed. Postoperative complications and factors affecting them were studied. Reconstructed area deformities were assessed using computed tomography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Postoperative complications occurred significantly more frequently in patients reconstructed with the silicone sheet than in those reconstructed with the u-HA\/PLLA sheet. Deformities were found for the silicone sheet (28.6 percent) and poly-L-lactic acid\/poly-glycolic acid mesh (31.9 percent). These deformity rates were significantly higher than those for the u-HA\/PLLA sheet.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Compared with other alloplastic materials, u-HA\/PLLA has low rates of postoperative complications and reconstructed area deformities. Because of its complete absorption, clinicians should consider using u-HA\/PLLA as an alloplastic material for orbital wall reconstruction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CLINICAL QUESTION\/LEVEL OF EVIDENCE:<\/jats:title>\n            <jats:p>Therapeutic, III.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/prs.0000000000009554","type":"journal-article","created":{"date-parts":[[2022,8,15]],"date-time":"2022-08-15T17:03:54Z","timestamp":1660583034000},"page":"865-875","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Intermediate Outcomes of Orbital Wall Reconstruction Using Different Alloplastic Materials: Which Is Ideal?"],"prefix":"10.1097","volume":"150","author":[{"given":"Keishi","family":"Kohyama","sequence":"first","affiliation":[{"name":"From the Department of Plastic and Reconstructive Surgery, Ogaki Municipal Hospital; and Gifu University Hospital Innovative and Clinical Research Promotion Center, Gifu University."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuma","family":"Ishihara","sequence":"additional","affiliation":[{"name":"From the Department of Plastic and Reconstructive Surgery, Ogaki Municipal Hospital; and Gifu University Hospital Innovative and Clinical Research Promotion Center, Gifu University."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiki","family":"Tsuboi","sequence":"additional","affiliation":[{"name":"From the Department of Plastic and Reconstructive Surgery, Ogaki Municipal Hospital; and Gifu University Hospital Innovative and Clinical Research Promotion Center, Gifu University."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoko","family":"Morishima","sequence":"additional","affiliation":[{"name":"From the Department of Plastic and Reconstructive Surgery, Ogaki Municipal Hospital; and Gifu University Hospital Innovative and Clinical Research Promotion Center, Gifu University."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,7,29]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/01.PRS.0000096704.34065.03","article-title":"Reconstruction of orbital floor fracture using solvent-preserved bone graft.","volume":"113","author":"Yavuzer","year":"2004","journal-title":"Plast Reconstr Surg"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/01.sap.0000199173.73610.bc","article-title":"Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants.","volume":"56","author":"Nam","year":"2006","journal-title":"Ann Plast Surg"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.jcms.2009.06.011","article-title":"Treatment of orbital floor fracture using a periosteum-polymer complex.","volume":"38","author":"Asamura","year":"2010","journal-title":"J Craniomaxillofac Surg"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"3248","DOI":"10.1016\/j.actbio.2011.05.016","article-title":"Biomaterials and implants for orbital floor repair.","volume":"7","author":"Baino","year":"2011","journal-title":"Acta Biomater"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1016\/j.bjps.2018.03.006","article-title":"Immediate and long-term results of unsintered hydroxyapatite and poly L-lactide composite sheets for orbital wall fracture reconstruction.","volume":"71","author":"Kohyama","year":"2018","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"2001","DOI":"10.1097\/SCS.0000000000005734","article-title":"Use of unsintered hydroxyapatite and poly-L-lactic acid composite sheets for management of orbital wall fracture.","volume":"30","author":"Tsumiyama","year":"2019","journal-title":"J Craniofac Surg"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"5542","DOI":"10.1016\/j.biomaterials.2005.02.016","article-title":"The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles\/poly l-lactide (F-u-HA\/PLLA).","volume":"26","author":"Shikinami","year":"2005","journal-title":"Biomaterials"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/j.biomaterials.2005.09.003","article-title":"A 5-7 year in vivo study of high-strength hydroxyapatite\/poly(L-lactide) composite rods for the internal fixation of bone fractures.","volume":"27","author":"Hasegawa","year":"2006","journal-title":"Biomaterials"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1002\/(SICI)1097-4636(19991205)47:3<412::AID-JBM17>3.0.CO;2-B","article-title":"Bonding behavior of ultrahigh strength unsintered hydroxyapatite particles\/poly(L-lactide) composites to surface of tibial cortex in rabbits.","volume":"47","author":"Yasunaga","year":"1999","journal-title":"J Biomed Mater Res"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1097\/00006534-198504000-00009","article-title":"Orbital volume measurements in enophthalmos using three-dimensional CT imaging.","volume":"75","author":"Bite","year":"1985","journal-title":"Plast Reconstr Surg"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1111\/j.0006-341X.2000.00645.x","article-title":"A note on robust variance estimation for cluster-correlated data.","volume":"56","author":"Williams","year":"2000","journal-title":"Biometrics"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/j.joms.2014.02.027","article-title":"Treatment of malar and midfacial fractures with osteoconductive forged unsintered hydroxyapatite and poly-L-lactide composite internal fixation devices.","volume":"72","author":"Landes","year":"2014","journal-title":"J Oral Maxillofac Surg"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1002\/jbm.b.10027","article-title":"Long-term study of high-strength hydroxyapatite\/poly(L-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits.","volume":"66","author":"Ishii","year":"2003","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/0278-2391(95)90714-9","article-title":"The use of silastic as an orbital implant for reconstruction of orbital wall defects: Review of 311 cases treated over 20 years.","volume":"53","author":"Morrison","year":"1995","journal-title":"J Oral Maxillofac Surg"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.bjps.2019.09.011","article-title":"Symptomatic cystic lesions as late post-operative complications of silicone implantation for orbital wall fracture reconstruction: A long-term follow-up study.","volume":"73","author":"Kohyama","year":"2020","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1097\/01.prs.0000244519.26368.4c","article-title":"Reconstruction of internal orbital wall fracture with iliac crest free bone graft: Clinical, computed tomography, and magnetic resonance imaging follow-up study.","volume":"118","author":"Kontio","year":"2006","journal-title":"Plast Reconstr Surg"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/0278-2391(90)90487-M","article-title":"Poly(L-lactide) implants in repair of defects of the orbital floor: An animal study.","volume":"48","author":"Rozema","year":"1990","journal-title":"J Oral Maxillofac Surg"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/j.jcms.2013.05.039","article-title":"Long-term result of a biodegradable osteo-inductive copolymer for the treatment of orbital blowout fracture.","volume":"42","author":"Morotomi","year":"2014","journal-title":"J Craniomaxillofac Surg"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1054\/ijom.2001.0067","article-title":"Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant.","volume":"30","author":"Kontio","year":"2001","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1054\/ijom.2001.0219","article-title":"Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet.","volume":"31","author":"Baumann","year":"2002","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1097\/SCS.0b013e3181acde01","article-title":"Analysis of orbital bone fractures: A 12-year study of 391 patients.","volume":"20","author":"Hwang","year":"2009","journal-title":"J Craniofac Surg"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/j.jcms.2014.01.013","article-title":"Segmental stability in orthognathic surgery: Hydroxyapatite\/poly-l-lactide osteoconductive composite versus titanium miniplate osteosyntheses.","volume":"42","author":"Landes","year":"2014","journal-title":"J Craniomaxillofac Surg"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/S0142-9612(99)00232-X","article-title":"Biodegradation behavior of ultra-high-strength hydroxyapatite\/poly (L-lactide) composite rods for internal fixation of bone fractures.","volume":"21","author":"Furukawa","year":"2000","journal-title":"Biomaterials"},{"issue":"suppl 1","key":"R24-20250502","first-page":"1991","article-title":"Materials used for reconstruction after orbital floor fracture.","volume":"23","author":"Avashia","year":"2012","journal-title":"J Craniofac Surg"}],"container-title":["Plastic &amp; Reconstructive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000009554","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T01:01:48Z","timestamp":1746147708000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000009554"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,29]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/prs.0000000000009554","relation":{},"ISSN":["0032-1052"],"issn-type":[{"value":"0032-1052","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7,29]]}}}