{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T09:09:31Z","timestamp":1771232971939,"version":"3.50.1"},"reference-count":71,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>A novel tendon stapler device (TSD) to improve the strength and consistency of primary tendon repairs was recently approved by the U.S. Food and Drug Administration. The authors hypothesized that this TSD would demonstrate faster and superior biomechanical properties compared with a standard suture coaptation. The authors also hypothesized that the TSD biomechanical properties would be consistent across participants with differing tendon repair experiences.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Participants included a novice, intermediate, and expert in tendon repairs. Timed comparisons were performed in flexor zones IV and V and extensor zones VI and VII on human cadaver arms. Suture repairs were performed with a modified Kessler technique with a horizontal mattress. TSD repairs were performed on the matched donor arms. Biomechanical testing included 2-mm gap force, ultimate failure load, and mode of failure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In total, 228 tendon coaptations from 12 donor arms were performed and analyzed. TSD coaptations were 3 times faster and withstood nearly 50% higher forces on 2-mm gap testing and roughly 30% higher forces on ultimate failure testing. These findings did not change when the repair times were analyzed by participant. Suture coaptations failed owing to suture pull-through, suture breakage, or knot failure. TSD coaptation failures only occurred from device pull-through.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The TSD produces significantly faster and stronger primary tendon coaptations compared with a standard 4-strand core suture repair in human donor arms. The findings demonstrated minimal variability among participants with differing tendon repair experience. Although further investigation is needed, this device has potential to revolutionize tendon repairs.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/prs.0000000000011102","type":"journal-article","created":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T14:09:01Z","timestamp":1695996541000},"page":"582-591","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Wrist-Level Tendon Repairs Utilizing a Novel Tendon Stapler Device: An Efficiency and Biomechanical Study"],"prefix":"10.1097","volume":"154","author":[{"given":"Evelyn R.","family":"Reed","sequence":"first","affiliation":[{"name":"Division of Plastic Surgery, Department of Surgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Russell","family":"Hendrycks","sequence":"additional","affiliation":[{"name":"Division of Plastic Surgery, Department of Surgery"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emily M.","family":"Graham","sequence":"additional","affiliation":[{"name":"Division of Plastic, Reconstructive, and Oral Surgery, Division of Orthopaedic Surgery, Children\u2019s Hospital of Philadelphia, Perelman School of Medicine at the University of Pennsylvania."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Megan","family":"Rosales","sequence":"additional","affiliation":[{"name":"Division of Epidemiology, Department of Internal Medicine, University of Utah School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaun D.","family":"Mendenhall","sequence":"additional","affiliation":[{"name":"Division of Plastic Surgery, Department of Surgery"},{"name":"Division of Plastic, Reconstructive, and Oral Surgery, Division of Orthopaedic Surgery, Children\u2019s Hospital of Philadelphia, Perelman School of Medicine at the University of Pennsylvania."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2023,9,29]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.cps.2011.08.006","article-title":"Flexor tendon reconstruction.","volume":"38","author":"Derby","year":"2011","journal-title":"Clin Plast Surg"},{"key":"R2-20250502","first-page":"1307","article-title":"Galen on Psychology, Psychopathology, and Function and Diseases of Nervous System - Siegel,Re.","volume":"131","author":"Hankoff","year":"1974","journal-title":"Am J Psychiat"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.hcl.2004.03.004","article-title":"History of flexor tendon repair.","volume":"21","author":"Manske","year":"2005","journal-title":"Hand Clin"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/S0363-5023(05)80189-3","article-title":"Biomechanical and histologic characteristics of canine flexor tendon repair using early postoperative mobilization.","volume":"22","author":"Aoki","year":"1997","journal-title":"J Hand Surg Am"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1002\/jor.1100020107","article-title":"Flexor tendon repair in vitro: a comparative histologic study of the rabbit, chicken, dog, and monkey.","volume":"2","author":"Gelberman","year":"1984","journal-title":"J Orthop Res"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"70","DOI":"10.2106\/00004623-198365010-00010","article-title":"Flexor tendon healing and restoration of the gliding surface: an ultrastructural study in dogs.","volume":"65","author":"Gelberman","year":"1983","journal-title":"J Bone Joint Surg Am"},{"issue":"6 Pt 1","key":"R7-20250502","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1016\/S0363-5023(85)80151-9","article-title":"The early stages of flexor tendon healing: a morphologic study of the first fourteen days.","volume":"10","author":"Gelberman","year":"1985","journal-title":"J Hand Surg Am"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0363-5023(77)80025-7","article-title":"Primary flexor tendon repair followed by immediate controlled mobilization.","volume":"2","author":"Lister","year":"1977","journal-title":"J Hand Surg Am"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/S0363-5023(96)80302-9","article-title":"Cyclic stress testing after in vivo healing of canine flexor tendon lacerations.","volume":"21","author":"Pruitt","year":"1996","journal-title":"J Hand Surg Am"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/S0749-0712(21)01341-X","article-title":"Results of flexor tendon surgery in zone II.","volume":"1","author":"Strickland","year":"1985","journal-title":"Hand Clin"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/S0363-5023(80)80101-8","article-title":"Digital function following flexor tendon repair in zone II: a comparison of immobilization and controlled passive motion techniques.","volume":"5","author":"Strickland","year":"1980","journal-title":"J Hand Surg Am"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1177\/15589447211043213","article-title":"Alternative tendon coaptations to the Pulvertaft weave technique: a systematic review and meta-analysis of biomechanical studies.","volume":"18","author":"Graham","year":"2021","journal-title":"Hand (N Y)"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"44","DOI":"10.5435\/00124635-199501000-00006","article-title":"Flexor tendon injuries: I: foundations of treatment.","volume":"3","author":"Strickland","year":"1995","journal-title":"J Am Acad Orthop Surg"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1053\/jhsu.2000.jhsu25a0214","article-title":"Development of flexor tendon surgery: twenty-five years of progress.","volume":"25","author":"Strickland","year":"2000","journal-title":"J Hand Surg Am"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"220","DOI":"10.32098\/mltj.03.2013.16","article-title":"Suture techniques for tendon repair; a comparative review.","volume":"3","author":"Rawson","year":"2013","journal-title":"Muscles Ligaments Tendons J"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"104","DOI":"10.5152\/j.aott.2020.01.411","article-title":"Biomechanical comparison of Bunnell, modified Kessler, and Tsuge tendon repair techniques using two suture types.","volume":"54","author":"Dundar","year":"2020","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1016\/j.jhsa.2018.08.012","article-title":"Factors accounting for variation in the biomechanical properties of flexor tendon repairs.","volume":"43","author":"Linnanm\u00e4ki","year":"2018","journal-title":"J Hand Surg Am"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1097\/PRS.0000000000004416","article-title":"New developments are improving flexor tendon repair.","volume":"141","author":"Tang","year":"2018","journal-title":"Plast Reconstr Surg"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/j.1532-950X.2013.12076.x","article-title":"Knot security and tensile strength of suture materials.","volume":"43","author":"Marturello","year":"2014","journal-title":"Vet Surg"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.jhsa.2007.03.003","article-title":"Flexor tendon repairs: the impact of fiberwire on grasping and locking core sutures.","volume":"32","author":"Miller","year":"2007","journal-title":"J Hand Surg Am"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1016\/j.jhsa.2011.03.033","article-title":"Comparison of a new multifilament stainless steel suture with frequently used sutures for flexor tendon repair.","volume":"36","author":"McDonald","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1142\/S0218810414970065","article-title":"Usefulness of braided polyblend polyethylene suture material for flexor tendon repair in zone II by the side-locking loop technique.","volume":"19","author":"Ryoke","year":"2014","journal-title":"Hand Surg"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1016\/j.jhsa.2015.04.009","article-title":"A mechanical evaluation of zone II flexor tendon repair using a knotless barbed suture versus a traditional braided suture.","volume":"40","author":"Nayak","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1053\/j.jfas.2019.01.022","article-title":"Biomechanical study of a multifilament stainless steel cable crimp system versus a multistrand ultra-high molecular weight polyethylene polyester suture Krackow technique for Achilles tendon rupture repair.","volume":"59","author":"Nguyen","year":"2020","journal-title":"J Foot Ankle Surg"},{"key":"R25-20250502","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1007\/s10195-008-0016-4","article-title":"Flexor tendon injuries of the hand treated with TenoFix: mid-term results.","volume":"9","author":"Rocchi","year":"2008","journal-title":"J Orthop Traumatol"},{"key":"R26-20250502","doi-asserted-by":"crossref","first-page":"288","DOI":"10.3113\/JSOA.2013.0288","article-title":"Biomechanical evaluation of a cable-crimp system designed for repair of tendons and ligaments in the hand.","volume":"22","author":"Gordon","year":"2013","journal-title":"J Surg Orthop Adv"},{"key":"R27-20250502","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.jhsa.2013.01.018","article-title":"Analysis of a knotless flexor tendon repair using a multifilament stainless steel cable-crimp system.","volume":"38","author":"Gordon","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R28-20250502","doi-asserted-by":"crossref","first-page":"1846","DOI":"10.1016\/j.jhsa.2014.06.025","article-title":"Flexor tendon repairs: techniques, eponyms, and evidence.","volume":"39","author":"Chauhan","year":"2014","journal-title":"J Hand Surg Am"},{"key":"R29-20250502","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1177\/1558944717701238","article-title":"Comparing biomechanical properties, repair times, and value of common core flexor tendon repairs.","volume":"13","author":"Chauhan","year":"2018","journal-title":"Hand (N Y)"},{"key":"R30-20250502","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jhsa.2004.07.020","article-title":"The biomechanical analysis of a tendon fixation device for flexor tendon repair.","volume":"30","author":"Su","year":"2005","journal-title":"J Hand Surg Am"},{"key":"R31-20250502","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jpra.2018.06.003","article-title":"An extensive volar forearm laceration: the spaghetti wrist: a systematic review.","volume":"18","author":"Koshy","year":"2018","journal-title":"JPRAS Open"},{"key":"R32-20250502","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1055\/s-0036-1586487","article-title":"Treatment and postsurgery functional outcome of spaghetti wrist.","volume":"8","author":"Yazdanshenas","year":"2016","journal-title":"J Hand Microsurg"},{"key":"R33-20250502","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1177\/1558944719863127","article-title":"Technique for rapid hand transplant donor procurement through the elbow.","volume":"16","author":"Mendenhall","year":"2021","journal-title":"Hand (N Y)"},{"key":"R34-20250502","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.hcl.2011.07.005","article-title":"The history and evolution of hand transplantation.","volume":"27","author":"Foroohar","year":"2011","journal-title":"Hand Clin"},{"key":"R35-20250502","doi-asserted-by":"crossref","first-page":"351e","DOI":"10.1097\/PRS.0000000000000892","article-title":"Hand and upper extremity transplantation: an update of outcomes in the worldwide experience.","volume":"135","author":"Shores","year":"2015","journal-title":"Plast Reconstr Surg"},{"key":"R36-20250502","doi-asserted-by":"crossref","first-page":"97","DOI":"10.6002\/ect.2018.0163","article-title":"Hand transplantation: current status and immunologic obstacles.","volume":"17","author":"Park","year":"2019","journal-title":"Exp Clin Transplant"},{"key":"R37-20250502","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.jss.2018.03.022","article-title":"Prolonged operative duration is associated with complications: a systematic review and meta-analysis.","volume":"229","author":"Cheng","year":"2018","journal-title":"J Surg Res"},{"key":"R38-20250502","doi-asserted-by":"crossref","first-page":"e448","DOI":"10.1097\/TXD.0000000000000888","article-title":"Impact of cold ischemia time on outcomes of deceased donor kidney transplantation: an analysis of a national registry.","volume":"5","author":"Peters-Sengers","year":"2019","journal-title":"Transplant Direct"},{"key":"R39-20250502","doi-asserted-by":"crossref","first-page":"2572","DOI":"10.1111\/ajt.14290","article-title":"Prolonged cold ischemia time results in local and remote organ dysfunction in a murine model of vascularized composite transplantation.","volume":"17","author":"Datta","year":"2017","journal-title":"Am J Transplant"},{"key":"R40-20250502","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1503\/cjs.032910","article-title":"Effect of surgeon fatigue on hip and knee arthroplasty.","volume":"55","author":"Peskun","year":"2012","journal-title":"Can J Surg"},{"key":"R41-20250502","doi-asserted-by":"crossref","first-page":"878.e1","DOI":"10.1016\/j.jhsa.2020.02.015","article-title":"Biomechanical analysis of zone 2 flexor tendon repair with a coupler device versus locking cruciate core suture.","volume":"45","author":"Irwin","year":"2020","journal-title":"J Hand Surg Am"},{"key":"R42-20250502","doi-asserted-by":"crossref","first-page":"2482","DOI":"10.2106\/00004623-200411000-00019","article-title":"Effect of gap size on gliding resistance after flexor tendon repair.","volume":"86","author":"Zhao","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R43-20250502","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/j.jhsa.2005.03.011","article-title":"A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.","volume":"30","author":"Lawrence","year":"2005","journal-title":"J Hand Surg Am"},{"key":"R44-20250502","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1053\/jhsu.2001.22926","article-title":"Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs.","volume":"26","author":"Barrie","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R45-20250502","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1053\/jhsu.2001.28946","article-title":"Evaluation of suture caliber in flexor tendon repair.","volume":"26","author":"Taras","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R46-20250502","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.jhsa.2005.09.006","article-title":"Influence of core suture purchase length on strength of four-strand tendon repairs.","volume":"31","author":"Cao","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R47-20250502","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.jhsa.2005.05.011","article-title":"Core suture purchase affects strength of tendon repairs.","volume":"30","author":"Tang","year":"2005","journal-title":"J Hand Surg Am"},{"key":"R48-20250502","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1197\/j.jht.2005.01.005","article-title":"Friction of the gliding surface: implications for tendon surgery and rehabilitation.","volume":"18","author":"Amadio","year":"2005","journal-title":"J Hand Ther"},{"key":"R49-20250502","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/j.jhsa.2009.12.044","article-title":"Technical and biological modifications for enhanced flexor tendon repair.","volume":"35","author":"Kim","year":"2010","journal-title":"J Hand Surg Am"},{"key":"R50-20250502","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.jhsa.2011.11.006","article-title":"Complications after flexor tendon repair: a systematic review and meta-analysis.","volume":"37","author":"Dy","year":"2012","journal-title":"J Hand Surg Am"},{"key":"R51-20250502","doi-asserted-by":"crossref","first-page":"1712","DOI":"10.1016\/j.jhsa.2013.06.025","article-title":"Flexor tendon repair rehabilitation protocols: a systematic review.","volume":"38","author":"Starr","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R52-20250502","doi-asserted-by":"crossref","first-page":"693e","DOI":"10.1097\/PRS.0000000000006075","article-title":"Addressing surgeon fatigue: current understanding and strategies for mitigation.","volume":"144","author":"Janhofer","year":"2019","journal-title":"Plast Reconstr Surg"},{"key":"R53-20250502","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1177\/1558944718790579","article-title":"Building a hand and upper extremity transplantation program: lessons learned from the first 20 years of vascularized composite allotransplantation.","volume":"15","author":"Mendenhall","year":"2020","journal-title":"Hand (N Y)"},{"key":"R54-20250502","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/S0266-7681(05)80084-1","article-title":"Work of flexion after tendon repair with various suture methods: a human cadaveric study.","volume":"20","author":"Aoki","year":"1995","journal-title":"J Hand Surg Br"},{"key":"R55-20250502","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1054\/JHSB.1999.0287","article-title":"Flexor tendon repair using a stainless steel external splint: biomechanical study on human cadaver flexor tendons.","volume":"24","author":"Gordon","year":"1999","journal-title":"J Hand Surg Br"},{"key":"R56-20250502","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1142\/S242483551850056X","article-title":"An exploratory study using semi-tabular plate in zone II flexor tendon repair.","volume":"23","author":"Wong","year":"2018","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"R57-20250502","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1302\/0301-620X.92B8.23029","article-title":"A new barbed device for repair of flexor tendons.","volume":"92","author":"Hirpara","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"R58-20250502","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/j.jhsa.2006.10.004","article-title":"Biomechanic comparison of the Teno Fix tendon repair device with the cruciate and modified Kessler techniques.","volume":"32","author":"Wolfe","year":"2007","journal-title":"J Hand Surg Am"},{"issue":"Suppl 1, Pt 1","key":"R59-20250502","first-page":"37","article-title":"A device for zone-II flexor tendon repair: surgical technique.","volume":"88","author":"Su","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R60-20250502","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1177\/1753193413492914","article-title":"Recent developments in flexor tendon repair techniques and factors influencing strength of the tendon repair.","volume":"39","author":"Wu","year":"2014","journal-title":"J Hand Surg Eur Vol"},{"key":"R61-20250502","doi-asserted-by":"crossref","first-page":"e5167","DOI":"10.1097\/GOX.0000000000005167","article-title":"Learning curve of wrist-level tendon repairs using a novel tendon stapler versus traditional suture methods.","volume":"11","author":"Hendrycks","year":"2023","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R62-20250502","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1089\/sur.2017.089","article-title":"Prolonged operative duration increases risk of surgical site infections: a systematic review.","volume":"18","author":"Cheng","year":"2017","journal-title":"Surg Infect (Larchmt)"},{"key":"R63-20250502","doi-asserted-by":"crossref","first-page":"196","DOI":"10.3201\/eid0902.020232","article-title":"Health and economic impact of surgical site infections diagnosed after hospital discharge.","volume":"9","author":"Perencevich","year":"2003","journal-title":"Emerg Infect Dis"},{"key":"R64-20250502","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1007\/s11999-012-2267-x","article-title":"Value-based healthcare and orthopaedic surgery.","volume":"470","author":"Bozic","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"R65-20250502","doi-asserted-by":"crossref","first-page":"2106","DOI":"10.1016\/j.bjps.2020.08.019","article-title":"Value-based plastic surgery.","volume":"73","author":"Harrison","year":"2020","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"R66-20250502","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1007\/s11999-015-4648-4","article-title":"Value-based healthcare: the value of considering patient preferences and circumstances in orthopaedic surgery.","volume":"474","author":"Ring","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"R67-20250502","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1097\/00005131-199710000-00006","article-title":"Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.","volume":"11","author":"Jain","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R68-20250502","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/0020-1383(75)90174-6","article-title":"Incorporation of stainless steel, titanium and vitallium in bone.","volume":"6","author":"Linder","year":"1975","journal-title":"Injury"},{"key":"R69-20250502","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1302\/0301-620X.85B1.12749","article-title":"Microvascular response of striated muscle to metal debris: a comparative in vivo study with titanium and stainless steel.","volume":"85","author":"Kraft","year":"2003","journal-title":"J Bone Joint Surg Br"},{"issue":"Suppl 2","key":"R70-20250502","first-page":"351","article-title":"The reaction of bone to titanium, stainless steel and chrome\/cobalt implants.","volume":"74","author":"Linder","year":"1988","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"R71-20250502","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/01.blo.0000205894.98361.29","article-title":"Effects of implant material and plate design on tendon function and morphology.","volume":"445","author":"Cohen","year":"2006","journal-title":"Clin Orthop Relat Res"}],"container-title":["Plastic &amp; Reconstructive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000011102","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T01:05:16Z","timestamp":1746147916000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000011102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,29]]},"references-count":71,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/prs.0000000000011102","relation":{},"ISSN":["0032-1052","1529-4242"],"issn-type":[{"value":"0032-1052","type":"print"},{"value":"1529-4242","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,29]]}}}