{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T07:52:29Z","timestamp":1769068349979,"version":"3.49.0"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Tendon reconstruction is a difficult procedure with unpredictable results, and evaluating and selecting the appropriate muscle tendon is crucial. To improve the results of tendon reconstruction, the authors investigated active muscle contraction during wide-awake local anesthesia no tourniquet (WALANT) surgery, in which the patient can perform active movements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Among 213 WALANT tendon reconstructions, 148 muscle tendons were evaluated for active contraction distance and passive stretch distance of the muscle tendons, time elapsed before reconstruction, and characteristics and changes in muscle active contraction patterns after verbal instructions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Active contraction and passive stretch distances showed significant positive correlations and flexor muscles displayed larger distances than extensor muscles. Time elapsed before reconstruction did not correlate with either distance. In the flexor digitorum superficialis muscle, active contraction distance was greater in the grip-related ulnar digits, but the late-phase pattern was more frequent. In the extensor indicis proprius muscle, contraction distance on instruction to extend the thumb was smaller than that when instructed to extend the index finger.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>WALANT surgery is the only procedure in which active contraction distance and characteristics of muscle tendons can be observed intraoperatively, and it appears useful for tendon transfer.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/prs.0000000000012298","type":"journal-article","created":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T16:00:19Z","timestamp":1755014419000},"page":"231e-241e","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Correlation between Passive Stretch and Active Contraction Distance and Characteristics of Musculotendinous Units from WALANT Surgery Study"],"prefix":"10.1097","volume":"157","author":[{"given":"Mineyuki","family":"Zukawa","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Toyama"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryusuke","family":"Osada","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Itoigawa General Hospital."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuro","family":"Hirokawa","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Toyama"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hikaru","family":"Wada","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Itoigawa General Hospital."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masatoshi","family":"Satomi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kurobe City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kanoko","family":"Horikawa","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kurobe City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiharu","family":"Kawaguchi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Toyama"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,8,11]]},"reference":[{"key":"R1-20260121","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1177\/1753193417728427","article-title":"Conceptual origins, current practice, and views of wide awake hand surgery.","volume":"42","author":"Lalonde","year":"2017","journal-title":"J Hand Surg Eur Vol"},{"key":"R2-20260121","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.2106\/JBJS.RVW.17.00142","article-title":"Wide-awake hand surgery: principles and techniques.","volume":"6","author":"Warrender","year":"2018","journal-title":"JBJS Rev"},{"key":"R3-20260121","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.jhsg.2022.01.009","article-title":"Current evidence involving WALANT surgery.","volume":"4","author":"Connors","year":"2022","journal-title":"J Hand Surg Glob Online"},{"key":"R4-20260121","doi-asserted-by":"crossref","first-page":"e3507","DOI":"10.1097\/GOX.0000000000003507","article-title":"Wide-awake local anesthesia with no tourniquet: an updated review.","volume":"9","author":"Kurtzman","year":"2021","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R5-20260121","doi-asserted-by":"crossref","first-page":"275","DOI":"10.4055\/cios.2015.7.3.275","article-title":"Wide-awake primary flexor tendon repair, tenolysis, and tendon transfer.","volume":"7","author":"Tang","year":"2015","journal-title":"Clin Orthop Surg"},{"key":"R6-20260121","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.isjp.2020.03.001","article-title":"Use of wide-awake local anaesthetic no tourniquet (WALANT) in upper limb and hand surgery: a systematic review protocol.","volume":"20","author":"O\u2019Neill","year":"2020","journal-title":"Int J Surg Protoc"},{"key":"R7-20260121","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1097\/PRS.0000000000005092","article-title":"Wide-awake flexor pollicis longus tendon reconstruction with evaluation of the active voluntary contraction of the ruptured muscle-tendon.","volume":"143","author":"Zukawa","year":"2019","journal-title":"Plast Reconstr Surg"},{"key":"R8-20260121","doi-asserted-by":"crossref","first-page":"500.e1","DOI":"10.1016\/j.jhsa.2023.09.014","article-title":"Wide-awake local anesthesia no tourniquet surgery for zone VII extensor tendon reconstruction: stages in active range of motion from intraoperative to final recovery.","volume":"50","author":"Osada","year":"2023","journal-title":"J Hand Surg Am"},{"key":"R9-20260121","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.jhsg.2022.04.001","article-title":"Usefulness of wide-awake local anesthesia no tourniquet surgery to decide on tendon transfer versus grafting in chronic flexor tendon rupture.","volume":"4","author":"Zukawa","year":"2022","journal-title":"J Hand Surg Glob Online"},{"key":"R10-20260121","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.jhsa.2004.12.010","article-title":"Flexor superficialis abductor transfer with carpal tunnel release for thenar palsy.","volume":"30","author":"Richer","year":"2005","journal-title":"J Hand Surg Am"},{"key":"R11-20260121","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/S0363-5023(83)80065-3","article-title":"Restoration of flexor pollicis longus function by flexor digitorum superficialis transfer.","volume":"8","author":"Schneider","year":"1983","journal-title":"J Hand Surg Am"},{"key":"R12-20260121","first-page":"97","article-title":"Tendon transfer for radial palsy.","volume":"21","author":"Boyes","year":"1960","journal-title":"Bull Hosp Joint Dis"},{"key":"R13-20260121","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/0266-7681(91)90131-7","article-title":"The anatomy of the flexor digitorum superficialis relevant to tendon transfers.","volume":"16","author":"Agee","year":"1991","journal-title":"J Hand Surg Br"},{"key":"R14-20260121","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1097\/01.prs.0000256071.00235.d0","article-title":"Immediate thumb extension following extensor indicis proprius-to-extensor pollicis longus tendon transfer using the wide-awake approach.","volume":"119","author":"Bezuhly","year":"2007","journal-title":"Plast Reconstr Surg"},{"key":"R15-20260121","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0363-5023(81)80072-X","article-title":"Relative tension and potential excursion of muscles in the forearm and hand.","volume":"6","author":"Brand","year":"1981","journal-title":"J Hand Surg Am"},{"key":"R17-20260121","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/S0363-5023(79)80069-6","article-title":"Determination of muscle-tendon unit properties during tendon transfer.","volume":"4","author":"Freehafer","year":"1979","journal-title":"J Hand Surg Am"},{"key":"R18-20260121","first-page":"479","article-title":"Tendon glide distance as a basis for tendon surgery (in Japanese).","volume":"46","author":"Saito","year":"1972","journal-title":"J Jpn Orthop Assoc"},{"key":"R19-20260121","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/00003086-200210001-00019","article-title":"Tendon transfer surgery: clinical implications of experimental studies.","volume":"403","author":"Frid\u00e9n","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"R20-20260121","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/00003086-198203000-00012","article-title":"Reconstructive procedures for extremities with peripheral nerve defects.","volume":"163","author":"Omer","year":"1982","journal-title":"Clin Orthop Relat Res"},{"key":"R21-20260121","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1113\/jphysiol.2005.089201","article-title":"Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.","volume":"567","author":"Butler","year":"2005","journal-title":"J Physiol"},{"key":"R22-20260121","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1055\/s-0041-1734577","article-title":"Wide-awake approach for flexor digitorum superficialis tendon transfer followed by early active mobilization.","volume":"54","author":"Kuroda","year":"2021","journal-title":"Indian J Plast Surg"},{"key":"R23-20260121","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/0266-7681(92)90184-4","article-title":"Opponensplasty by extensor indicis and flexor digitorum superficialis tendon transfer.","volume":"17","author":"Anderson","year":"1992","journal-title":"J Hand Surg Br"},{"key":"R24-20260121","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1093\/brain\/119.4.1199","article-title":"Throwing while looking through prisms: II. Specificity and storage of multiple gaze-throw calibrations.","volume":"119","author":"Martin","year":"1996","journal-title":"Brain"},{"key":"R25-20260121","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1037\/0033-2909.101.1.41","article-title":"Historical review and appraisal of research on the learning, retention, and transfer of human motor skills.","volume":"101","author":"Adams","year":"1987","journal-title":"Psychol Bull"},{"key":"R26-20260121","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1152\/jn.00832.2009","article-title":"Thinking about walking: effects of conscious correction versus distraction on locomotor adaptation.","volume":"103","author":"Malone","year":"2010","journal-title":"J Neurophysiol"},{"key":"R27-20260121","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.neuron.2011.04.012","article-title":"Rethinking motor learning and savings in adaptation paradigms: model free memory for successful actions combines with internal models.","volume":"70","author":"Huang","year":"2011","journal-title":"Neuron"},{"key":"R28-20260121","doi-asserted-by":"crossref","first-page":"2537","DOI":"10.1152\/jn.90529.2008","article-title":"Explaining savings for visuomotor adaptation: linear time invariant state-space models are not sufficient.","volume":"100","author":"Zarahn","year":"2008","journal-title":"J Neurophysiol"},{"key":"R29-20260121","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1523\/JNEUROSCI.4218-04.2005","article-title":"Adaptation to visuomotor transformations: consolidation, interference, and forgetting.","volume":"25","author":"Krakauer","year":"2005","journal-title":"J Neurosci"},{"key":"R30-20260121","doi-asserted-by":"crossref","first-page":"e179","DOI":"10.1371\/journal.pbio.0040179","article-title":"Interacting adaptive processes with different timescales underlie short-term motor learning.","volume":"4","author":"Smith","year":"2006","journal-title":"PLoS Biol"},{"key":"R31-20260121","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1097\/PRS.0000000000006611","article-title":"Comparison of the wide-awake approach and conventional approach in extensor indicis proprius-to-extensor pollicis longus tendon transfer for chronic extensor pollicis longus rupture.","volume":"145","author":"Hong","year":"2020","journal-title":"Plast Reconstr Surg"},{"key":"R32-20260121","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1016\/j.bjps.2014.03.006","article-title":"Standard versus over-tensioning in the transfer of extensor indicis proprius to extensor pollicis longus for chronic rupture of the thumb extensor.","volume":"67","author":"Jung","year":"2014","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"R33-20260121","doi-asserted-by":"crossref","first-page":"2297","DOI":"10.1016\/j.jhsa.2014.08.024","article-title":"Wide-awake extensor indicis proprius to extensor pollicis longus tendon transfer.","volume":"39","author":"Lalonde","year":"2014","journal-title":"J Hand Surg Am"}],"container-title":["Plastic &amp; Reconstructive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000012298","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T16:03:16Z","timestamp":1769011396000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PRS.0000000000012298"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,11]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/prs.0000000000012298","relation":{},"ISSN":["0032-1052","1529-4242"],"issn-type":[{"value":"0032-1052","type":"print"},{"value":"1529-4242","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,11]]}}}