{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T18:55:48Z","timestamp":1783018548491,"version":"3.54.6"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      The increasing number of younger patients requiring\n                      <jats:italic toggle=\"yes\">cardiac implantable electronic devices<\/jats:italic>\n                      (CIEDs) necessitates not only survival but also a preserved quality of life. Aesthetic considerations for CIED placement\u2014particularly in the context of the female breast\u2014are increasingly important, yet current guidelines lack standardized recommendations for ideal generator pocket positioning, especially in the presence of breast implants. We report the first use of bovine pericardium mesh to reposition a migrated, protruding subcutaneous CIED in a patient with prior breast implant reconstruction, who presented with breast contour distortion. Generator pocket repositioning was performed using an\n                      <jats:italic toggle=\"yes\">acellular biological matrix<\/jats:italic>\n                      (ABM) to anchor the device securely against the prepectoral fascia, effectively preventing future dislodgement. The patient achieved excellent breast symmetry and a smooth transition between the anterior chest wall and the superolateral mammary pole. Postoperative ultrasonography confirmed successful compartmentalization of the periprosthetic space, matrix, and device. Durable device positioning was maintained at 12-month follow-up. This case demonstrates that reinforcement and repositioning of subcutaneous CIEDs using ABM in patients with breast implants offers multiple advantages including minimized tissue disruption; stable positioning along the chest wall; isolation of the periprosthetic space; and aesthetic outcomes comparable to those achieved with deeper device placement.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/psn.0000000000000673","type":"journal-article","created":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T17:49:19Z","timestamp":1783014559000},"page":"147-152","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Optimizing Aesthetic Results in Breast Surgery and Cardiac Implantable Electronic Device (CIED) Placement Using Acellular Biological Matrices"],"prefix":"10.1097","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-6283-8613","authenticated-orcid":false,"given":"Elena","family":"Benedito","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5730-8637","authenticated-orcid":false,"given":"Javier","family":"Mont\u00f3n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor Manuel","family":"Hidalgo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica Marcela","family":"Juez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Talaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregorio Jes\u00fas","family":"G\u00f3mez-Bajo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"9","key":"R1-20260702","doi-asserted-by":"crossref","first-page":"2614","DOI":"10.3390\/jcm13092614","article-title":"Reinforcement of a subcutaneous pocket for implantable cardioverter defibrillator insertion using acellular dermal matrix: A case report","volume":"13","author":"Choi","year":"2024","journal-title":"Journal of Clinical Medicine"},{"issue":"1","key":"R3-20260702","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1111\/j.1540-8159.1997.tb04822.x","article-title":"Retromammary implantation of an ICD using a single lead system: An alternative approach to pectoral implantation in women","volume":"20","author":"Gadhoke","year":"1997","journal-title":"Pacing and Clinical Electrophysiology"},{"issue":"11","key":"R4-20260702","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1046\/j.1460-9592.2001.01679.x","article-title":"Experience with a cosmetic approach to device implantation","volume":"24","author":"Giudici","year":"2001","journal-title":"Pacing and Clinical Electrophysiology"},{"issue":"11","key":"R5-20260702","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1111\/j.1540-8159.2010.02871.x","article-title":"Submammary pacemakers and ICDs in women: Long-term follow-up and patient satisfaction","volume":"33","author":"Giudici","year":"2010","journal-title":"Pacing and Clinical Electrophysiology"},{"issue":"10","key":"R6-20260702","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1016\/j.jacep.2017.02.016","article-title":"Antibacterial envelope is associated with low infection rates after implantable cardioverter-defibrillator and cardiac resynchronization therapy device replacement","volume":"3","author":"Henrikson","year":"2017","journal-title":"JACC Clinical Electrophysiology"},{"issue":"5","key":"R7-20260702","doi-asserted-by":"crossref","first-page":"734","DOI":"10.4070\/kcj.2016.46.5.734","article-title":"Combined subpectoral implantation of implantable cardioverter-defibrillator and augmentation mammoplasty in a young female patient","volume":"46","author":"Kim","year":"2016","journal-title":"Korean Circulation Journal"},{"issue":"2","key":"R8-20260702","doi-asserted-by":"crossref","first-page":"e70132","DOI":"10.1002\/ccr3.70132","article-title":"Implantable cardioverter defibrillator generator replacement and breast implant revision\u2014A combined case","volume":"13","author":"Lamprou","year":"2025","journal-title":"Clinical Case Reports"},{"issue":"12","key":"R9-20260702","doi-asserted-by":"crossref","first-page":"1808","DOI":"10.1016\/j.bjps.2013.06.024","article-title":"Technical tip: A case demonstrating the synchronous placement of implantable cardioverter defibrillator and bilateral breast augmentation","volume":"66","author":"Lye","year":"2013","journal-title":"Journal of Plastic, Reconstructive & Aesthetic Surgery"},{"issue":"11","key":"R10-20260702","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1111\/j.1540-8159.1990.tb02132.x","article-title":"A technique for the prevention of automatic implantable cardioverter defibrillator generator migration","volume":"13","author":"Mancini","year":"1990","journal-title":"Pacing and Clinical Electrophysiology"},{"key":"R11-20260702","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.ijcard.2021.11.049","article-title":"Incidence of lead erosion in a real-world cohort and a case of successful treatment with an antimicrobial mesh","volume":"349","author":"Ma\u021big","year":"2022","journal-title":"International Journal of Cardiology"},{"issue":"1","key":"R12-20260702","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.cjca.2019.08.012","article-title":"Trends of sex differences in outcomes of cardiac electronic device implantations in the United States","volume":"36","author":"Mohamed","year":"2020","journal-title":"Canadian Journal of Cardiology"},{"issue":"12","key":"R13-20260702","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1056\/NEJMoa013474","article-title":"Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction","volume":"346","author":"Moss","year":"2002","journal-title":"The New England Journal of Medicine"},{"issue":"1","key":"R14-20260702","doi-asserted-by":"crossref","first-page":"34","DOI":"10.5999\/aps.2017.44.1.34","article-title":"Transaxillary subpectoral placement of cardiac implantable electronic devices in young female patients","volume":"44","author":"Oh","year":"2017","journal-title":"Archives of Plastic Surgery"},{"issue":"9","key":"R15-20260702","doi-asserted-by":"crossref","first-page":"e849","DOI":"10.1097\/GOX.0000000000000855","article-title":"Silicone breast implant and automatic implantable cardioverter defibrillator: Can they coexist? A case report","volume":"4","author":"Or","year":"2016","journal-title":"Plastic and Reconstructive Surgery \u2013 Global Open"},{"issue":"6 Pt. 1","key":"R16-20260702","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1111\/j.1540-8159.2004.00528.x","article-title":"Implantation of submammary implantable cardioverter defibrillators","volume":"27","author":"\u00d6z\u0131n","year":"2004","journal-title":"Pacing and Clinical Electrophysiology"},{"issue":"5","key":"R17-20260702","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1001\/archsurg.1972.04180100095023","article-title":"A stretch fabric pouch for implanted pacemakers","volume":"105","author":"Parsonnet","year":"1972","journal-title":"Archives of Surgery"},{"issue":"4","key":"R18-20260702","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1111\/jce.16196","article-title":"Cardiac implantable electronic devices in female patients: Aesthetic, breast implant, and anatomic considerations","volume":"35","author":"Salinas","year":"2024","journal-title":"Journal of Cardiovascular Electrophysiology"},{"key":"R19-20260702","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.ijcard.2016.07.124","article-title":"Submammary device implantation: Good long-term performance and better patient satisfaction. A single-center experience","volume":"221","author":"Savastano","year":"2016","journal-title":"International Journal of Cardiology"},{"issue":"2","key":"R20-20260702","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.jtcvs.2008.12.015","article-title":"A novel solution for repeated migration of an implantable cardiac defibrillator","volume":"139","author":"Sheikh","year":"2010","journal-title":"The Journal of Thoracic and Cardiovascular Surgery"},{"key":"R21-20260702","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.ahj.2016.06.010","article-title":"Worldwide Randomized Antibiotic Envelope Infection Prevention Trial (WRAP-IT)","volume":"180","author":"Tarakji","year":"2016","journal-title":"American Heart Journal"},{"issue":"2","key":"R22-20260702","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1055\/a-2015-8803","article-title":"Use of acellular biologic matrix envelope for cardiac implantable electronic device placement to correct migration into submuscular breast implant pocket","volume":"50","author":"Terry","year":"2023","journal-title":"Archives of Plastic Surgery"},{"issue":"5","key":"R23-20260702","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/SAP.0b013e318250f06c","article-title":"Subglandular placement of an implantable cardioverter-defibrillator for an improved cosmetic outcome","volume":"71","author":"Wright","year":"2013","journal-title":"Annals of Plastic Surgery"},{"issue":"7","key":"R24-20260702","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.hrcr.2019.05.003","article-title":"A novel bio envelope and suture orientation for stabilization of the subcutaneous implantable cardioverter-defibrillator generator to the chest wall","volume":"5","author":"Xiang","year":"2019","journal-title":"HeartRhythm Case Reports"}],"container-title":["Plastic and Aesthetic Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PSN.0000000000000673","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T17:49:22Z","timestamp":1783014562000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PSN.0000000000000673"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/psn.0000000000000673","relation":{},"ISSN":["2770-3509","2770-3517"],"issn-type":[{"value":"2770-3509","type":"print"},{"value":"2770-3517","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]}}}