{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:44:38Z","timestamp":1790747078210,"version":"4.1.0"},"reference-count":46,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Persons with lower limb amputation require increased functionality. The largest category of feet for active individuals with a transtibial amputation is energy storage and return (ESR) feet. These feet are typically constructed of carbon fiber composite materials. Recently, a prosthetic foot composed of a fiberglass composite has emerged in the market. However, there are no comparative studies of these devices.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Compare the biomechanical performance and prosthesis-related quality of life when using a fiberglass prosthetic foot design compared with traditional carbon fiber ESR designs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>This is a repeated-measures randomized cross-over trial.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Gait analysis was performed on 10 experienced male subjects with unilateral transtibial amputations (K-level III) while walking on level ground and a ramp. Patient-reported outcomes were collected using the Prosthesis Evaluation Questionnaire.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Gait data demonstrated increased ankle dorsiflexion (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .01), similar ankle moments (<jats:italic toggle=\"yes\">P<\/jats:italic> = .07), and increased ankle power generation (<jats:italic toggle=\"yes\">P<\/jats:italic> = .01) when using the fiberglass foot. The increased power generation occurred at the correct time in the gait cycle such that the timing and magnitude of peak knee flexion was unaffected (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; .19). The fiberglass foot had greater energy absorption during gait (<jats:italic toggle=\"yes\">P<\/jats:italic> = .01) with no difference in energy return (<jats:italic toggle=\"yes\">P<\/jats:italic> = .37). The subjects expressed improved prosthesis-related quality of life with the fiberglass foot (<jats:italic toggle=\"yes\">P<\/jats:italic> = .01).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The findings of this study demonstrate that the new ESR foot comprising a fiberglass material had better performance than traditional designs using a carbon fiber material.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/pxr.0000000000000004","type":"journal-article","created":{"date-parts":[[2021,4,17]],"date-time":"2021-04-17T04:16:35Z","timestamp":1618632995000},"page":"205-213","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":14,"title":["Functional performance differences between carbon fiber and fiberglass prosthetic feet"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7311-3781","authenticated-orcid":false,"given":"Kenton R.","family":"Kaufman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathie","family":"Bernhardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,3,25]]},"reference":[{"key":"R1-20250818","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/00003086-199904000-00006","article-title":"Modern prosthetic knee mechanisms","volume":"361","author":"Michael","year":"1999","journal-title":"Clin Orthop"},{"key":"R2-20250818","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1080\/17483100802715092","article-title":"Prosthetic feet: State-of-the-art review and the importance of mimicking human ankle-foot biomechanics","volume":"4","author":"Versluys","year":"2009","journal-title":"Disabil Rehabil Assist Technol"},{"key":"R3-20250818","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1682\/JRRD.2003.06.0102","article-title":"A systematic literature review of the effect of different prosthetic components on human functioning with a lower-limb prosthesis","volume":"41","author":"van der linde","year":"2004","journal-title":"J Rehabil Res Dev"},{"key":"R4-20250818","first-page":"CD003978","article-title":"Prescription of prosthetic ankle-foot mechanisms after lower limb amputation","volume":"1","author":"Hofstad","year":"2004","journal-title":"Cochrane Database Syst Rev"},{"key":"R5-20250818","doi-asserted-by":"crossref","first-page":"13","DOI":"10.31026\/j.eng.2018.03.02","article-title":"Impact response for two designs of athletic prosthetic feet","volume":"24","author":"Hamzah","year":"2018","journal-title":"J Eng"},{"key":"R6-20250818","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1177\/0309364616683980","article-title":"Instantaneous stiffness and hysteresis of dynamic elastic response prosthetic feet","volume":"41","author":"Webber","year":"2017","journal-title":"Prosthet Orthot Int"},{"key":"R7-20250818","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.clinbiomech.2016.08.013","article-title":"The dead spot phenomenon in prosthetic gait: quantified with an analysis of center of pressure progression and its velocity in the sagittal plane","volume":"38","author":"Klenow","year":"2016","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R8-20250818","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s12984-018-0347-1","article-title":"Prosthetic energy return during walking increases after 3 weeks of adaptation to a new device","volume":"15","author":"Ray","year":"2018","journal-title":"J Neuroeng Rehabil"},{"key":"R9-20250818","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1002\/jor.1100080310","article-title":"Measurement of lower extremity kinematics during level walking","volume":"8","author":"Kadaba","year":"1990","journal-title":"J Orthop Res"},{"key":"R10-20250818","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1152\/physrev.1989.69.4.1199","article-title":"Optimization and gaits in the locomotion of vertebrates","volume":"69","author":"Alexander","year":"1989","journal-title":"Physiol Rev"},{"key":"R11-20250818","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1016\/0021-9290(94)00176-5","article-title":"A comparison of intersegmental joint dynamics to isokinetic dynamometer measurements","volume":"28","author":"Kaufman","year":"1995","journal-title":"J Biomech"},{"key":"R12-20250818","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1111\/j.1600-0838.2008.00769.x","article-title":"A review of research on the mechanical stiffness in running and jumping: methodology and implications","volume":"18","author":"Brughelli","year":"2008","journal-title":"Scand J Med Sci Sports"},{"key":"R13-20250818","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1016\/0021-9290(94)90194-5","article-title":"Translational and rotational joint power terms in a six degree-of-freedom model of the normal ankle complex","volume":"27","author":"Buczek","year":"1994","journal-title":"J Biomech"},{"key":"R14-20250818","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/S0021-9290(00)00102-0","article-title":"Comparison of methods for the calculation of energy storage and return in a dynamic elastic response prosthesis","volume":"33","author":"Geil","year":"2000","journal-title":"J Biomech"},{"key":"R15-20250818","first-page":"155","article-title":"Issues of importance reported by persons with lower limb amputations and prostheses","volume":"36","author":"Legro","year":"1999","journal-title":"J Rehabil Res Dev"},{"key":"R16-20250818","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/S0003-9993(98)90090-9","article-title":"Prosthesis Evaluation Questionnaire for persons with lower limb amputations: assessing prosthesis-related quality of life","volume":"79","author":"Legro","year":"1998","journal-title":"Arch Phys Med Rehabil"},{"key":"R17-20250818","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1136\/ip.2004.006965","article-title":"The effects of recall on reporting injury and poisoning episodes in the National Health Interview Survey","volume":"11","author":"Warner","year":"2005","journal-title":"Inj Prev"},{"key":"R18-20250818","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/0003-9993(93)90013-Z","article-title":"Comprehensive analysis of dynamic elastic response feet: Seattle ankle\/lite foot versus SACH foot","volume":"74","author":"Lehmann","year":"1993","journal-title":"Arch Phys Med Rehabil"},{"key":"R19-20250818","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.gaitpost.2011.08.021","article-title":"Outdoor dynamic subject-specific evaluation of internal stresses in the residual limb: hydraulic energy-stored prosthetic foot compared to conventional energy-stored prosthetic feet","volume":"35","author":"Portnoy","year":"2012","journal-title":"Gait Posture"},{"key":"R20-20250818","doi-asserted-by":"crossref","first-page":"17","DOI":"10.3109\/03093649709164526","article-title":"Energy storage and release of prosthetic feet. Part 1: biomechanical analysis related to user benefits","volume":"21","author":"Postema","year":"1997","journal-title":"Prosthet Orthot Int"},{"key":"R21-20250818","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/j.humov.2011.08.005","article-title":"The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation","volume":"31","author":"Segal","year":"2012","journal-title":"Hum Mov Sci"},{"key":"R22-20250818","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1016\/j.apmr.2006.06.013","article-title":"The effect of foot and ankle prosthetic components on braking and propulsive impulses during transtibial amputee gait","volume":"87","author":"Zmitrewicz","year":"2006","journal-title":"Arch Phys Med Rehabil"},{"key":"R23-20250818","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/0021-9290(77)90049-5","article-title":"Walking speed as a basis for normal and abnormal gait measurements","volume":"10","author":"Andriacchi","year":"1977","journal-title":"J Biomech"},{"key":"R24-20250818","doi-asserted-by":"crossref","first-page":"78","DOI":"10.3109\/03093649309164360","article-title":"Walking speed of normal subjects and amputees: aspects of validity of gait analysis","volume":"17","author":"Boonstra","year":"1993","journal-title":"Prosthet Orthot Int"},{"key":"R25-20250818","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1682\/JRRD.2011.04.0077","article-title":"Application of self-report and performance-based outcome measures to determine functional differences between four categories of prosthetic feet","volume":"49","author":"Gailey","year":"2012","journal-title":"J Rehabil Res Dev"},{"key":"R26-20250818","first-page":"111","article-title":"Energy expenditure during ambulation in dysvascular and traumatic below-knee amputees: a comparison of five prosthetic feet","volume":"32","author":"Torburn","year":"1995","journal-title":"J Rehabil Res Dev"},{"key":"R27-20250818","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.gaitpost.2011.11.005","article-title":"Evaluating asymmetry in prosthetic gait with step-length asymmetry alone is flawed","volume":"35","author":"Roerdink","year":"2012","journal-title":"Gait Posture"},{"key":"R28-20250818","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.2522\/ptj.20130431","article-title":"Stepping asymmetry among individuals with unilateral transtibial limb loss might be functional in terms of gait stability","volume":"94","author":"Hak","year":"2014","journal-title":"Phys Ther"},{"key":"R29-20250818","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.gaitpost.2007.06.008","article-title":"Elderly unilateral transtibial amputee gait on an inclined walkway: a biomechanical analysis","volume":"27","author":"Vickers","year":"2008","journal-title":"Gait Posture"},{"key":"R30-20250818","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1682\/JRRD.1990.10.0369","article-title":"Below-knee amputee gait with dynamic elastic response prosthetic feet: a pilot study","volume":"27","author":"Torburn","year":"1990","journal-title":"J Rehabil Res Dev"},{"key":"R31-20250818","first-page":"309","article-title":"The effect of five prosthetic feet on the gait and loading of the sound limb in dysvascular below-knee amputees","volume":"32","author":"Snyder","year":"1995","journal-title":"J Rehabil Res Dev"},{"key":"R32-20250818","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.gaitpost.2018.06.022","article-title":"Benefits of an increased prosthetic ankle range of motion for individuals with a trans-tibial amputation walking with a new prosthetic foot","volume":"64","author":"Heitzmann","year":"2018","journal-title":"Gait Posture"},{"key":"R33-20250818","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1177\/0309364617698521","article-title":"Effect of foot and ankle immobilization on able-bodied gait as a model to increase understanding about bilateral transtibial amputee gait","volume":"41","author":"Nepomuceno","year":"2017","journal-title":"Prosthet Orthot Int"},{"key":"R34-20250818","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jbiomech.2014.10.002","article-title":"Biomechanical characteristics, patient preference and activity level with different prosthetic feet: a randomized double blind trial with laboratory and community testing","volume":"48","author":"Raschke","year":"2015","journal-title":"J Biomech"},{"key":"R35-20250818","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00003086-198305000-00021","article-title":"Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences","volume":"175","author":"Winter","year":"1983","journal-title":"Clin Orthop Relat Res"},{"key":"R36-20250818","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1177\/0309364614564021","article-title":"Step-to-step transition work during level and inclined walking using passive and powered ankle-foot prostheses","volume":"40","author":"Esposito","year":"2016","journal-title":"Prosthet Orthot Int"},{"key":"R37-20250818","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.gaitpost.2009.02.009","article-title":"The energy cost for the step-to-step transition in amputee walking","volume":"30","author":"Houdijk","year":"2009","journal-title":"Gait Posture"},{"key":"R38-20250818","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1016\/j.apmr.2012.06.009","article-title":"Evaluation of a powered ankle-foot prosthetic system during walking","volume":"93","author":"Ferris","year":"2012","journal-title":"Arch Phys Med Rehabil"},{"key":"R39-20250818","first-page":"457","article-title":"Bionic ankle-foot prosthesis normalizes walking gait for persons with leg amputation","volume":"279","author":"Herr","year":"2012","journal-title":"Proc Biol Sci"},{"key":"R40-20250818","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/1050-6411(92)90024-D","article-title":"Calf muscle work and segment energy changes in fuman treadmill walking","volume":"2","author":"Hof","year":"1993","journal-title":"J Electromyogr Kinesiol"},{"key":"R41-20250818","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1242\/jeb.107391","article-title":"Impulsive ankle push-off powers leg swing in human walking","volume":"217","author":"Lipfert","year":"2014","journal-title":"J Exp Biol"},{"key":"R42-20250818","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/S0268-0033(02)00020-7","article-title":"Energy storage and return prostheses: does patient perception correlate with biomechanical analysis?","volume":"17","author":"Hafner","year":"2002","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R43-20250818","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1080\/03093640802016514","article-title":"Physical activity and quality of life: a study of a lower-limb amputee population","volume":"32","author":"Deans","year":"2008","journal-title":"Prosthet Orthot Int"},{"key":"R44-20250818","doi-asserted-by":"crossref","first-page":"82","DOI":"10.23736\/S1973-9087.19.05799-X","article-title":"The minimal clinically-important difference of the Prosthesis Evaluation Questionnaire-Mobility Scale in subjects undergoing lower limb prosthetic rehabilitation training","volume":"56","author":"Franchignoni","year":"2020","journal-title":"Eur J Phys Rehabil Med"},{"key":"R45-20250818","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/j.clinbiomech.2010.04.005","article-title":"Sagittal plane position of the functional joint centre of prosthetic foot\/ankle mechanisms","volume":"25","author":"Rusaw","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R46-20250818","doi-asserted-by":"crossref","first-page":"2662","DOI":"10.1016\/j.jbiomech.2012.08.017","article-title":"A unified deformable (UD) segment model for quantifying total power of anatomical and prosthetic below-knee structures during stance in gait","volume":"45","author":"Takahashi","year":"2012","journal-title":"J Biomech"}],"container-title":["Prosthetics &amp; Orthotics International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,18]],"date-time":"2025-08-18T20:01:14Z","timestamp":1755547274000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,25]]},"references-count":46,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/pxr.0000000000000004","relation":{},"ISSN":["0309-3646","1746-1553"],"issn-type":[{"value":"0309-3646","type":"print"},{"value":"1746-1553","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,25]]},"assertion":[{"value":"2020-12-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-11-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}