{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:45:35Z","timestamp":1787010335700,"version":"build-2736575974"},"reference-count":36,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The Scottish Specialist Prosthetics Service has provided microprocessor knees (MPKs) through the National Health Service since 2014, predominantly to high-activity transfemoral amputations (TFAs). Benefits of MPKs to the lower-activity TFA are less established in the literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This study aimed to compare patient-reported and functional measures in low-activity TFAs transitioning from a mechanical knee to a MPK.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>This is a retrospective cohort analysis of low-activity individuals with a unilateral TFA provided with an MPK.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Patient-reported measures were recorded in routine clinical care before and 6 months after MPK provision. These included HR-QoL (EQ-5D-5L Health Index), Activities Balance Confidence score, Prosthetic Limb User Survey of Mobility, falls frequency, use of walking aids, and Socket Comfort Score. Functional measures included the two-minute walk test (2MWT), L-test, and Amputee Mobility Predictor score, and three-dimensional gait analysis was used to generate a Gait Profile Score (GPS). The primary outcomes were HR-QoL and GPS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Forty-five participants fulfilled the inclusion criteria. Thirty-one had pre-MPK and post-MPK measures, of which 15 had three-dimensional gait analysis. The mean age (n = 31) was 60 years (SD 11), and 68% were male. HR-QoL and GPS did not significantly improve with MPK provision (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.014 and\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.019); Amputee Mobility Predictor score, L-Test, 2MWT, falls, and Activities Balance Confidence score showed a significant improvement with MPK provision (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Although no statistically significant change in the primary outcomes was measured, there were sufficient data to support MPK provision in low-activity prosthetic users with participants demonstrating improvements in balance, 2MWT, falls frequency, and confidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/pxr.0000000000000017","type":"journal-article","created":{"date-parts":[[2021,5,20]],"date-time":"2021-05-20T22:01:17Z","timestamp":1621548077000},"page":"198-204","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Comparison of patient-reported and functional outcomes following transition from mechanical to microprocessor knee in the low-activity user with a unilateral transfemoral amputation"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9475-8298","authenticated-orcid":false,"given":"Fiona","family":"Davie-Smith","sequence":"first","affiliation":[{"name":"WestMARC, NHS Greater Glasgow and Clyde, Glasgow, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1649-006X","authenticated-orcid":false,"given":"Bruce","family":"Carse","sequence":"additional","affiliation":[{"name":"WestMARC, NHS Greater Glasgow and Clyde, Glasgow, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250818","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.rehab.2018.04.003","article-title":"Mobility and satisfaction with a microprocessor-controlled knee in moderately active amputees: a multi-centric randomized crossover trial","volume":"61","author":"Lansade","year":"2018","journal-title":"Ann Phys Rehabil Med"},{"key":"R2-20250818","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1177\/0309364613506912","article-title":"Impact of a stance phase microprocessor controlled knee prosthesis on level walking in lower functioning individuals with a transfemoral amputation","volume":"38","author":"Eberly","year":"2014","journal-title":"Prosthet Orthot Int"},{"key":"R3-20250818","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.apmr.2006.10.030","article-title":"Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee","volume":"88","author":"Hafner","year":"2007","journal-title":"Arch Phys Med Rehabil"},{"key":"R4-20250818","doi-asserted-by":"crossref","first-page":"125","DOI":"10.21300\/18.2-3.2016.125","article-title":"Predicting walking ability following lower limb amputation: an updated systematic literature review","volume":"18","author":"Kahle","year":"2016","journal-title":"Technol Innovat"},{"key":"R5-20250818","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1177\/0309364617704804","article-title":"Direct medical costs of accidental falls for adults with transfemoral amputations","volume":"41","author":"Mundell","year":"2017","journal-title":"Prosthet Orthot Int"},{"key":"R6-20250818","doi-asserted-by":"crossref","first-page":"906","DOI":"10.2340\/16501977-0861","article-title":"Functional added value of microprocessor-controlled prosthetic knee joints in daily life performance of Medicare Functional Classification Level-2 amputees","volume":"43","author":"Theeven","year":"2011","journal-title":"J Rehabil Med"},{"key":"R7-20250818","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/MRR.0000000000000267","article-title":"Comparison of mobility and user satisfaction between a microprocessor knee and a standard prosthetic knee: a summary of seven single-subject trials","volume":"41","author":"Howard","year":"2018","journal-title":"Int J Rehabil Res"},{"key":"R8-20250818","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1682\/JRRD.2008.01.0007","article-title":"Differences in function and safety between Medicare Functional Classification Level-2 and -3 transfemoral amputees and influence of prosthetic knee joint control","volume":"46","author":"Hafner","year":"2009","journal-title":"J Rehabil Res Dev"},{"key":"R9-20250818","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1080\/0963828021000056460","article-title":"The SIGAM mobility grades: a new population-specific measure for lower limb amputees","volume":"25","author":"Ryall","year":"2003","journal-title":"Disabil Rehabil"},{"key":"R10-20250818","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1053\/apmr.2002.32309","article-title":"The Amputee Mobility Predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate","volume":"83","author":"Gailey","year":"2002","journal-title":"Arch Phys Med Rehabil"},{"key":"R11-20250818","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/s40258-017-0310-5","article-title":"EQ-5D and the EuroQol Group: past, present and future","volume":"15","author":"Devlin","year":"2017","journal-title":"Appl Health Econ Health Policy"},{"key":"R12-20250818","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.1053\/apmr.2001.25079","article-title":"The influence of falling, fear of falling, and balance confidence on prosthetic mobility and social activity among individuals with a lower extremity amputation","volume":"82","author":"Miller","year":"2001","journal-title":"Arch Phys Med Rehabil"},{"key":"R13-20250818","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.apmr.2016.07.026","article-title":"Construct validity of the Prosthetic Limb Users Survey of Mobility (PLUS-M) in adults with lower limb amputation","volume":"98","author":"Hafner","year":"2017","journal-title":"Arch Phys Med Rehabil"},{"key":"R14-20250818","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1080\/09638280310001603983","article-title":"Prosthetic socket fit comfort score","volume":"25","author":"Hanspal","year":"2003","journal-title":"Disabil Rehabil"},{"key":"R15-20250818","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.physio.2017.11.218","article-title":"The reliability and validity of the L-test in people with Parkinson's disease","volume":"105","author":"Haas","year":"2019","journal-title":"Physiotherapy"},{"key":"R16-20250818","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1053\/apmr.2001.25153","article-title":"The 2-minute walk test as a measure of functional improvement in persons with lower limb amputation","volume":"82","author":"Brooks","year":"2001","journal-title":"Arch Phys Med Rehabil"},{"key":"R17-20250818","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.gaitpost.2009.05.020","article-title":"The Gait Profile Score and movement analysis profile","volume":"30","author":"Baker","year":"2009","journal-title":"Gait Posture"},{"key":"R18-20250818","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0966-6362(02)00122-4","article-title":"Symmetry in vertical ground reaction force is accompanied by symmetry in temporal but not distance variables of gait in persons with stroke","volume":"18","author":"Kim","year":"2003","journal-title":"Gait Posture"},{"key":"R19-20250818","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.gaitpost.2005.06.014","article-title":"A nondimensional normalization scheme for oxygen utilization data","volume":"24","author":"Schwartz","year":"2006","journal-title":"Gait Posture"},{"key":"R20-20250818","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.gaitpost.2016.09.024","article-title":"Medial-lateral centre of mass displacement and base of support are equally good predictors of metabolic cost in amputee walking","volume":"51","author":"Weinert-Aplin","year":"2017","journal-title":"Gait Posture"},{"key":"R21-20250818","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.gaitpost.2019.09.029","article-title":"A characterisation of established unilateral transfemoral amputee gait using 3D kinematics, kinetics and oxygen consumption measures","volume":"75","author":"Carse","year":"2020","journal-title":"Gait Posture"},{"key":"R23-20250818","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1177\/0309364616637955","article-title":"Stratified cost-utility analysis of C-Leg versus mechanical knees: findings from an Italian sample of transfemoral amputees","volume":"41","author":"Cutti","year":"2017","journal-title":"Prosthet Orthot Int"},{"key":"R24-20250818","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/JPO.0b013e31826f5e51","article-title":"A comparison of energy expenditure in people with transfemoral amputation using microprocessor and nonmicroprocessor knee prostheses: a systematic review","volume":"24","author":"Wong","year":"2012","journal-title":"J Prosthet Orthot"},{"key":"R25-20250818","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1097\/PHM.0000000000000265","article-title":"Benefits for adults with transfemoral amputations and peripheral artery disease using microprocessor compared with nonmicroprocessor prosthetic knees","volume":"94","author":"Wong","year":"2015","journal-title":"Am J Phys Med Rehabil"},{"key":"R26-20250818","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.clinbiomech.2018.07.012","article-title":"Functional assessment and satisfaction of transfemoral amputees with low mobility (FASTK2): a clinical trial of microprocessor-controlled vs. non-microprocessor-controlled knees","volume":"58","author":"Kaufman","year":"2018","journal-title":"Clin Biomech"},{"key":"R27-20250818","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1177\/0309364610397087","article-title":"Factors affecting quality of life in lower limb amputees","volume":"35","author":"Sinha","year":"2011","journal-title":"Prosthet Orthot Int"},{"key":"R28-20250818","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1177\/0309364611431611","article-title":"Impact of stance phase microprocessor-controlled knee prosthesis on ramp negotiation and community walking function in K2 level transfemoral amputees","volume":"36","author":"Burnfield","year":"2012","journal-title":"Prosthet Orthot Int"},{"key":"R29-20250818","doi-asserted-by":"crossref","first-page":"M287","DOI":"10.1093\/gerona\/53A.4.M287","article-title":"Discriminative and evaluative properties of the Activities-Specific Balance Confidence (ABC) scale","volume":"53","author":"Myers","year":"1998","journal-title":"J Gerontol A Biol Sci Med Sci"},{"key":"R30-20250818","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/JPO.0b013e318195b1d1","article-title":"Perceived stability, function, and satisfaction among transfemoral amputees using microprocessor and nonmicroprocessor controlled prosthetic knees: a multicenter survey","volume":"21","author":"Berry","year":"2009","journal-title":"J Prosthetics Orthot"},{"key":"R31-20250818","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1080\/17483107.2017.1300344","article-title":"Safety and function of a prototype microprocessor-controlled knee prosthesis for low active transfemoral amputees switching from a mechanic knee prosthesis: a pilot study","volume":"13","author":"Hasenoehrl","year":"2018","journal-title":"Disabil Rehabil Assist Technol"},{"key":"R32-20250818","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1177\/0309364614545418","article-title":"Minimal clinically important difference of the L Test for individuals with lower limb amputation: a pilot study","volume":"39","author":"Rushton","year":"2015","journal-title":"Prosthet Orthot Int"},{"key":"R33-20250818","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1093\/ptj\/85.7.626","article-title":"The L Test of Functional Mobility\u202f: \u201cUp & Go\u201d test designed for people","volume":"85","author":"Deathe","year":"2005","journal-title":"Phys Ther"},{"key":"R34-20250818","doi-asserted-by":"crossref","first-page":"555","DOI":"10.2522\/ptj.20100287","article-title":"Reliability of outcome measures for people with lower-limb amputations: distinguishing true change from statistical error","volume":"91","author":"Resnik","year":"2011","journal-title":"Phys Ther"},{"key":"R35-20250818","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1378\/chest.105.1.163","article-title":"Reanalysis of the 12-minute walk in patients with chronic obstructive pulmonary disease","volume":"105","author":"Bernstein","year":"1994","journal-title":"Chest"},{"key":"R36-20250818","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1080\/03093640802652029","article-title":"Developing core sets for persons following amputation based on the International Classification of Functioning, Disability and Health as a way to specify functioning","volume":"33","author":"Kohler","year":"2009","journal-title":"Prosthet Orthot Int"},{"key":"R37-20250818","doi-asserted-by":"crossref","first-page":"a1655","DOI":"10.1136\/bmj.a1655","article-title":"Medical Research Council: developing and evaluating complex interventions\u202f: new guidance","volume":"337","author":"Craig","year":"2008","journal-title":"Br Med J"}],"container-title":["Prosthetics &amp; Orthotics International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,18]],"date-time":"2025-08-18T20:00:53Z","timestamp":1755547253000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":36,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/pxr.0000000000000017","relation":{},"ISSN":["0309-3646","1746-1553"],"issn-type":[{"value":"0309-3646","type":"print"},{"value":"1746-1553","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"2021-01-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-25","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}