{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:44:29Z","timestamp":1790747069160,"version":"4.1.0"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T00:00:00Z","timestamp":1641772800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Individuals with unilateral transtibial amputation are at risk of abnormal mechanical joint loading and development of osteoarthritis on sound side joint structures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This study describes the spatiotemporal and kinetic and kinematic parameters related to osteoarthritis in participants while using (A) a solid-ankle cushioned-heel prosthesis (SACH), (B) a conventional energy storage and return (ESAR) foot prosthesis, and (C) a novel ESAR (N-ESAR) foot prosthesis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design:<\/jats:title>\n                    <jats:p>A pragmatic randomized controlled trial.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      K3\u2013K4 ambulators used three feet in a 2-week randomized cross-over order. Kinetics of vertical ground reaction forces (vGRFs) and 3D kinematics of joint angles were integrated to provide normalized parameters. Data were analyzed using one way and mixed model Analysis of variance (ANOVAs) (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.05) and Cohen d statistic.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Twenty participants, aged 40 \u00b1 16 years with body mass index of 24.7 \u00b1 3.6 kg\/m\n                      <jats:sup>2<\/jats:sup>\n                      , experienced minimal change in the spatiotemporal parameters between feet. Participants using the N-ESAR foot prosthesis experienced reduced peak knee external adduction moment (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.030), peak vGRFs (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001), and peak loading rate of vGRFs (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.030). Peak knee flexion moments only changed when using the solid-ankle cushioned-heel prosthesis, in a positive direction (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.014). Using the N-ESAR prosthesis also increased peak distal shank power during late stance phase (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>A novel ankle\/foot ESAR prosthesis reduces loading on the sound side. With extended use of the N-ESAR foot prosthesis, these findings may provide the prosthesis user with improved outcomes related to sound side loading and development of osteoarthritis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/pxr.0000000000000079","type":"journal-article","created":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T12:00:25Z","timestamp":1641988825000},"page":"258-266","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":17,"title":["A novel pivot ankle\/foot prosthesis reduces sound side loading and risk for osteoarthritis: a pragmatic randomized controlled trial"],"prefix":"10.1097","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8220-7694","authenticated-orcid":false,"given":"Phoebe","family":"Runciman","sequence":"first","affiliation":[{"name":"Department of Sport Science, Faculty of Medicine and Health Sciences, Stellenbosch University, Stellenbosch, South Africa"},{"name":"Institute of Sport and Exercise Medicine, Department of Surgical Sciences, Faculty of Medicine and Health Sciences, Stellenbosch University, South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4631-7591","authenticated-orcid":false,"given":"John","family":"Cockcroft","sequence":"additional","affiliation":[{"name":"Institute of Sport and Exercise Medicine, Department of Surgical Sciences, Faculty of Medicine and Health Sciences, Stellenbosch University, South Africa"},{"name":"Neuromechanics Unit, Central Analytics Facilities, Stellenbosch University, Stellenbosch, South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8879-177X","authenticated-orcid":false,"given":"Wayne","family":"Derman","sequence":"additional","affiliation":[{"name":"Institute of Sport and Exercise Medicine, Department of Surgical Sciences, Faculty of Medicine and Health Sciences, Stellenbosch University, South Africa"},{"name":"International Olympic Committee (IOC) Research Centre, Cape Town, South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1,10]]},"reference":[{"key":"R1-20250822","first-page":"S3","article-title":"The Pathophysiology of Osteoarthritis: A Mechanical Perspective on the Knee Joint","volume":"4","author":"Vincent","year":"2012","journal-title":"Pharm Manag PM R"},{"key":"R2-20250822","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1023\/B:ABME.0000017541.82498.37","article-title":"A Framework for the in Vivo Pathomechanics of Osteoarthritis at the Knee","volume":"32","author":"Andriacchi","year":"2004","journal-title":"Ann Biomed Eng"},{"key":"R3-20250822","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1002\/art.24336","article-title":"Does knee malalignment increase the risk of development and progression of knee osteoarthritis? A systematic review","volume":"61","author":"Tanamas","year":"2009","journal-title":"Arthritis Care Res"},{"key":"R4-20250822","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.knee.2008.12.007","article-title":"The association of external knee adduction moment with biomechanical variables in osteoarthritis: a systematic review","volume":"16","author":"Foroughi","year":"2009","journal-title":"Knee"},{"key":"R5-20250822","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1136\/bmjopen-2014-005368","article-title":"Is there a causal link between knee loading and knee osteoarthritis progression? A systematic review and meta-analysis of cohort studies and randomised trials","volume":"4","author":"Henriksen","year":"2014","journal-title":"BMJ Open"},{"key":"R6-20250822","doi-asserted-by":"crossref","first-page":"S96","DOI":"10.1097\/01.blo.0000143818.74887.b1","article-title":"Chondrocyte Senescence, Joint Loading and Osteoarthritis","volume":"427S","author":"Martin","year":"2004","journal-title":"Clin Orthop Relat Res"},{"key":"R7-20250822","first-page":"S20","article-title":"Osteoarthritis in the Disabled Population: A Mechanical Perspective","volume":"4","author":"Morgenroth","year":"2012","journal-title":"Pharm Manag PM R"},{"key":"R8-20250822","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.clinbiomech.2014.04.008","article-title":"The relationship between knee joint loading rate during walking and degenerative changes on magnetic resonance imaging","volume":"29","author":"Morgenroth","year":"2014","journal-title":"Clin Biomech"},{"key":"R9-20250822","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.joca.2018.04.011","article-title":"Relationship between knee joint contact forces and external knee joint moments in patients with medial knee osteoarthritis: effects of gait modifications","volume":"26","author":"Richards","year":"2018","journal-title":"Osteoarthritis Cartilage"},{"key":"R10-20250822","doi-asserted-by":"crossref","first-page":"e81036","DOI":"10.1371\/journal.pone.0081036","article-title":"Knee adduction moment and medial contact force--facts about their correlation during gait","volume":"8","author":"Kutzner","year":"2013","journal-title":"PLoS One"},{"key":"R11-20250822","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.joca.2015.02.779","article-title":"A more informed evaluation of medial compartment loading: the combined use of the knee adduction and flexor moments","volume":"23","author":"Manal","year":"2015","journal-title":"Osteoarthritis Cartilage"},{"key":"R12-20250822","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/j.joca.2015.03.032","article-title":"It's not all about the knee adduction moment: the role of the knee flexion moment in medial knee joint loading","volume":"23","author":"Creaby","year":"2015","journal-title":"Osteoarthritis Cartilage"},{"key":"R13-20250822","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.gaitpost.2016.07.007","article-title":"Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations","volume":"49","author":"Koelewijn","year":"2016","journal-title":"Gait Posture"},{"key":"R14-20250822","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1002\/jor.23151","article-title":"General scheme to reduce the knee adduction moment by modifying a combination of gait variables","volume":"34","author":"Favre","year":"2016","journal-title":"J Orthop Res"},{"key":"R15-20250822","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.jbiomech.2012.10.019","article-title":"Toe-in gait reduces the first peak knee adduction moment in patients with medial compartment knee osteoarthritis","volume":"46","author":"Shull","year":"2012","journal-title":"J Biomech"},{"key":"R16-20250822","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1186\/s12984-018-0403-x","article-title":"Reference values for gait temporal and loading symmetry of lower-limb amputees can help in refocusing rehabilitation targets","volume":"15","author":"Cutti","year":"2018","journal-title":"J NeuroEng Rehabil"},{"key":"R17-20250822","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1177\/0954411919874614","article-title":"Effects of simple knee sleeves on pain and knee adduction moment in early unilateral knee osteoarthritis","volume":"233","author":"Mohd Sharif","year":"2019","journal-title":"Proc IME H J Eng Med"},{"key":"R18-20250822","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/j.apmr.2004.04.034","article-title":"The Prevalence of Knee Pain and Symptomatic Knee Osteoarthritis Among Veteran Traumatic Amputees and Nonamputees","volume":"86","author":"Norvell","year":"2005","journal-title":"Arch Phys Med Rehabil"},{"key":"R19-20250822","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.gaitpost.2017.08.007","article-title":"Sound side joint contact forces in below knee amputee gait with an ESAR prosthetic foot","volume":"58","author":"Karimi","year":"2017","journal-title":"Gait Posture."},{"key":"R20-20250822","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1016\/j.gaitpost.2011.07.001","article-title":"The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees","volume":"34","author":"Morgenroth","year":"2011","journal-title":"Gait Posture"},{"key":"R21-20250822","doi-asserted-by":"crossref","first-page":"108","DOI":"10.4103\/2152-7806.196631","article-title":"Access to health care in sub-Saharan Africa","volume":"7","author":"Dechambenoit","year":"2016","journal-title":"Surg Neurol Int"},{"key":"R22-20250822","doi-asserted-by":"crossref","first-page":"378","DOI":"10.3109\/03093646.2010.520060","article-title":"Lower-limb prosthetic technologies in the developing world: A review of literature from 1994\u20132010","volume":"34","author":"Andrysek","year":"2010","journal-title":"Prosthet Orthot Int"},{"key":"R23-20250822","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1177\/0309364618789457","article-title":"Barriers and facilitators to utilisation of rehabilitation services amongst persons with lower-limb amputations in a rural community in South Africa","volume":"43","author":"Naidoo","year":"2019","journal-title":"Prosthet Orthot Int"},{"key":"R24-20250822","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.jclinepi.2016.04.010","article-title":"Pragmatic trial design elements showed a different impact on trial interpretation and feasibility than explanatory elements","volume":"77","author":"Nieuwenhuis","year":"2016","journal-title":"J Clin Epidemiol"},{"key":"R25-20250822","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1053\/apmr.2002.32309","article-title":"The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee\u2019s ability to ambulate","volume":"83","author":"Gailey","year":"2002","journal-title":"Arch Phys Med Rehabil"},{"key":"R26-20250822","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.gaitpost.2018.06.022","article-title":"Benefits of an increased prosthetic ankle range of motion for individuals with a trans-tibial amputation walking with a new prosthetic foot","volume":"64","author":"Heitzmann","year":"2018","journal-title":"Gait Posture"},{"key":"R27-20250822","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1080\/09638280310001603983","article-title":"Prosthetic socket fit comfort score","volume":"25","author":"Hanspal","year":"2003","journal-title":"Disabil Rehabil"},{"key":"R28-20250822","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1093\/ptj\/72.5.344","article-title":"Biomechanical comparison of the energy-storing capabilities of SACH and Carbon Copy II prosthetic feet during the stance phase of gait in a person with below-knee amputation","volume":"72","author":"Barr","year":"1992","journal-title":"Phys Ther"},{"key":"R29-20250822","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1682\/JRRD.1990.10.0369","article-title":"Below-knee amputee gait with dynamic elastic response prosthetic feet: A pilot study","volume":"27","author":"Torburn","year":"1990","journal-title":"J Rehabil Res Dev"},{"key":"R30-20250822","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.apmr.2005.07.310","article-title":"The effects of prosthetic foot design on physiologic measurements, self-selected walking velocity, and physical activity in people with transtibial amputation","volume":"87","author":"Hsu","year":"2006","journal-title":"Arch Phys Med Rehabil"},{"key":"R31-20250822","doi-asserted-by":"crossref","first-page":"5354","DOI":"10.1038\/s41598-018-23705-8","article-title":"Increasing prosthetic foot energy return affects whole-body mechanics during walking on level ground and slopes","volume":"8","author":"Childers","year":"2018","journal-title":"Sci Rep"},{"key":"R32-20250822","doi-asserted-by":"crossref","first-page":"107","DOI":"10.3109\/03093649709164538","article-title":"A new biomechanical method for determination of static prosthetic alignment","volume":"21","author":"Blumentritt","year":"1997","journal-title":"Prosthet Orthot Int"},{"key":"R33-20250822","doi-asserted-by":"crossref","first-page":"2662","DOI":"10.1016\/j.jbiomech.2012.08.017","article-title":"A unified deformable (UD) segment model for quantifying total power of anatomical and prosthetic below-knee structures during stance in gait","volume":"45","author":"Takahashi","year":"2012","journal-title":"J Biomech"},{"key":"R34-20250822","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jbiomech.2018.04.017","article-title":"Ankle and foot power in gait analysis: Implications for science, technology and clinical assessment","volume":"75","author":"Zelik","year":"2018","journal-title":"J Biomech"},{"key":"R35-20250822","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.apmr.2012.09.004","article-title":"Combined effects of a valgus knee brace and lateral wedge foot orthotic on the external knee adduction moment in patients with varus gonarthrosis","volume":"94","author":"Moyer","year":"2013","journal-title":"Arch Phys Med Rehabil"},{"key":"R36-20250822","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1136\/ard.61.7.617","article-title":"Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritis","volume":"61","author":"Miyazaki","year":"2002","journal-title":"Ann Rheum Dis"},{"key":"R37-20250822","first-page":"195","article-title":"Unloading knee brace is a cost-effective method to bridge and delay surgery in unicompartmental knee arthritis","volume":"2","author":"Paul","year":"2017","journal-title":"Exercise Medicine"},{"key":"R38-20250822","doi-asserted-by":"crossref","first-page":"e000468","DOI":"10.1136\/rmdopen-2017-000468","article-title":"Towards secondary prevention of early knee osteoarthritis","volume":"4","author":"Mahmoudian","year":"2018","journal-title":"RMD Open"},{"key":"R39-20250822","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1038\/nrrheum.2015.135","article-title":"Strategies for the prevention of knee osteoarthritis","volume":"12","author":"Roos","year":"2016","journal-title":"Nat Rev Rheumatol"}],"container-title":["Prosthetics &amp; Orthotics International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000079","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T17:00:25Z","timestamp":1755882025000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000079"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,10]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/pxr.0000000000000079","relation":{},"ISSN":["0309-3646","1746-1553"],"issn-type":[{"value":"0309-3646","type":"print"},{"value":"1746-1553","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,10]]},"assertion":[{"value":"2021-04-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-11-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}