{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T06:23:30Z","timestamp":1792736610899,"version":"4.5.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T00:00:00Z","timestamp":1647907200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-ccby-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,8]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Increased ankle power on the prosthetic side seems to decrease biomechanical loading parameters on the sound side. This assumption is based on biomechanical comparisons of different foot constructions. However, such study designs could not show whether the amount of ankle power solely influences the sound side.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To analyze the influence of divergent ankle power, resulting from different foot constructions and from different ankle power settings, on the sound side loading parameters.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Study design:<\/jats:title>\n            <jats:p>Interventional cross sectional study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Level walking of transfemoral amputees with a microprocessor knee joint and Solid Ankle Cushioned Heel (SACH), energy storing and returning (ESR) and powered foot (PF) was analyzed. The PF was adapted in three configurations: without power (np), low power (lp), and optimal power (op). An optoelectronic camera system with 12 cameras and two force plates were used.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The ankle power on the prosthetic side shows significant differences about foot types and different settings of the PF. The knee adduction moment, the knee flexion moment, and the vertical ground reaction forces on the sound side were significantly reduced with PF_op and ESR in comparison to SACH. When analyzing these parameters for the different PF configurations, only some show significant results at normal velocity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The additional positive mechanical work for an active push off in the PF tends to have a relieving effect. The biomechanical sound side loading parameters are reduced with PF_op in comparison to SACH and ESR, resulting in a relief of the sound side of lower limb amputees.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/pxr.0000000000000099","type":"journal-article","created":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T12:00:50Z","timestamp":1647950450000},"page":"306-313","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["How does ankle power on the prosthetic side influence loading parameters on the sound side during level walking of persons with transfemoral amputation?"],"prefix":"10.1097","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6349-2992","authenticated-orcid":false,"given":"Eva","family":"Pr\u00f6bsting","sequence":"first","affiliation":[{"name":"Clinical Research and Services, Research Biomechanics, Ottobock SE & Co. KGaA, G\u00f6ttingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3484-4346","authenticated-orcid":false,"given":"Bj\u00f6rn","family":"Altenburg","sequence":"additional","affiliation":[{"name":"Clinical Research and Services, Research Biomechanics, Ottobock SE & Co. KGaA, G\u00f6ttingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5002-9245","authenticated-orcid":false,"given":"Malte","family":"Bellmann","sequence":"additional","affiliation":[{"name":"Clinical Research and Services, Research Biomechanics, Ottobock SE & Co. KGaA, G\u00f6ttingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kerstin","family":"Krug","sequence":"additional","affiliation":[{"name":"University of Applied Sciences, M\u00fcnster, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2711-6591","authenticated-orcid":false,"given":"Thomas","family":"Schmalz","sequence":"additional","affiliation":[{"name":"Clinical Research and Services, Research Biomechanics, Ottobock SE & Co. KGaA, G\u00f6ttingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,3,22]]},"reference":[{"key":"R2-20250818","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/S0966-6362(97)01112-0","article-title":"Lower extremity kinematic and kinetic adaptations in unilateral below-knee amputees during walking","volume":"6","author":"Sanderson","year":"1997","journal-title":"Gait Posture"},{"key":"R3-20250818","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1016\/j.clinbiomech.2014.09.005","article-title":"Biomechanical risk factors for knee osteoarthritis when using passive and powered ankle-foot prostheses","volume":"29","author":"Russel Esposito","year":"2014","journal-title":"Clin Biomech"},{"key":"R4-20250818","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/1743-0003-10-49","article-title":"Effects of a powered ankle-foot prosthesis on kinetic loading of the unaffected leg during level-ground walking","volume":"10","author":"Grabowski","year":"2013","journal-title":"J NeuroEng Rehabil"},{"key":"R5-20250818","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1682\/JRRD.2015.03.0046","article-title":"Prosthetic interventions for people with transtibial amputation: systematic review and meta-analysis of high-quality prospective literature and systematic reviews","volume":"53","author":"Highsmith","year":"2016","journal-title":"J Rehabil Res Dev"},{"key":"R6-20250818","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1109\/TNSRE.2014.2356722","article-title":"Mechanisms of gait asymmetry due to push-off deficiency in unilateral amputees","volume":"23","author":"Adamczyk","year":"2015","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"R7-20250818","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.gaitpost.2009.02.009","article-title":"The energy cost for the step-to-step transition in amputee walking","volume":"30","author":"Houdijk","year":"2009","journal-title":"Gait Posture"},{"key":"R8-20250818","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1016\/j.gaitpost.2011.07.001","article-title":"The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees","volume":"34","author":"Morgenroth","year":"2011","journal-title":"Gait Posture"},{"key":"R9-20250818","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/S0736-0266(01)00081-X","article-title":"The knee adduction moment during gait in subjects with knee osteoarthritis is more closely correlated with static alignment than radiographic disease severity, toe out angle and pain","volume":"20","author":"Hurwitz","year":"2002","journal-title":"J Orthop Res"},{"key":"R10-20250818","doi-asserted-by":"crossref","first-page":"2835","DOI":"10.1002\/art.21262","article-title":"Secondary gait changes in patients with medial compartment knee osteoarthritis: increased load at the ankle, knee, and hip during walking","volume":"52","author":"M\u00fcndermann","year":"2005","journal-title":"Arthritis Rheum"},{"key":"R11-20250818","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.joca.2015.02.779","article-title":"A more informed evaluation of medial compartment loading: the combined use of the knee adduction and flexor moments","volume":"23","author":"Manal","year":"2015","journal-title":"Osteoarthritis Cartilage"},{"key":"R12-20250818","doi-asserted-by":"crossref","first-page":"S20","DOI":"10.1016\/j.pmrj.2012.01.003","article-title":"Osteoarthritis in the disabled population: a mechanical perspective","volume":"4","author":"Morgenroth","year":"2012","journal-title":"PM R"},{"key":"R13-20250818","first-page":"77","article-title":"Changes in the locomotor system as a consequence of amputation of a lower limb","volume":"155","author":"Pr\u00f6bsting","year":"2017","journal-title":"Z f\u00fcr Orthop Unfallchirurgie"},{"key":"R14-20250818","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/j.humov.2011.08.005","article-title":"The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation","volume":"31","author":"Segal","year":"2012","journal-title":"Hum Mov Sci"},{"key":"R15-20250818","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.gaitpost.2018.06.022","article-title":"Benefits of an increased prosthetic ankle range of motion for individuals with a trans-tibial amputation walking with a new prosthetic foot","volume":"64","author":"Heitzmann","year":"2018","journal-title":"Gait Posture"},{"key":"R16-20250818","doi-asserted-by":"crossref","first-page":"e0225032","DOI":"10.1371\/journal.pone.0225032","article-title":"Prosthetic push-off power in trans-tibial amputee level ground walking: a systematic review","volume":"14","author":"M\u00fcller","year":"2019","journal-title":"PLoS One"},{"key":"R17-20250818","first-page":"1","article-title":"Gait characteristics of transtibial amputees on level ground in a cohort of 53 amputees\u2014comparison of kinetics and kinematics with non-amputees","volume":"2","author":"Proebsting","year":"2019","journal-title":"CPOJ"},{"key":"R21-20250818","first-page":"18","article-title":"Das 3D L.A.S.A.R.\u2014eine neue Generation der Statik-Analyse zur Optimierung des Aufbaus von Prothesen und Orthesen","volume":"69","author":"Bellmann","year":"2017","journal-title":"Orthop Tech"},{"issue":"suppl 1","key":"R23-20250818","first-page":"555","article-title":"The ankle power of prosthetic feet \u2013 a relevant parameter?","volume":"73","author":"Proebsting","year":"2019","journal-title":"Gait Posture"},{"key":"R24-20250818","doi-asserted-by":"crossref","first-page":"5354","DOI":"10.1038\/s41598-018-23705-8","article-title":"Increasing prosthetic foot energy return affects whole-body mechanics during walking on level ground and slopes","volume":"8","author":"Childers","year":"2018","journal-title":"Sci Rep"}],"container-title":["Prosthetics &amp; Orthotics International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000099","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,18]],"date-time":"2025-08-18T20:01:04Z","timestamp":1755547264000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/PXR.0000000000000099"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,22]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/pxr.0000000000000099","relation":{},"ISSN":["0309-3646","1746-1553"],"issn-type":[{"value":"0309-3646","type":"print"},{"value":"1746-1553","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,22]]},"assertion":[{"value":"2021-02-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-01-04","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}