{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T13:36:59Z","timestamp":1786628219223,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:00:00Z","timestamp":1783036800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction and importance:<\/jats:title>\n                    <jats:p>Kirschner wires (K-wires) are widely used in orthopedic surgery for fracture fixation and joint stabilization, but complications such as migration, though rare, can have severe consequences.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation:<\/jats:title>\n                    <jats:p>We report the case of a 24-year-old female who presented with asymptomatic migration of a K-wire into the cervical spine, 32\u00a0months after clavicle fixation. Imaging revealed that the wire had traversed from the right first rib to the C6\u2013C7 interlaminar space. Surgical removal was performed via a posterior medial approach after an initial posterolateral dissection failed. Postoperative recovery was uneventful, with no complications or neurological deficits.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical discussion:<\/jats:title>\n                    <jats:p>This case marks the 14th reported instance of spinal K-wire migration and the first involving an asymptomatic female patient.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>It underscores the importance of careful surgical technique, routine follow-up, timely hardware removal, and the role of advanced imaging in detecting and managing such rare but potentially serious complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rc9.0000000000000656","type":"journal-article","created":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T09:17:04Z","timestamp":1783070224000},"page":"2891-2896","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Asymptomatic migration of Kirschner wire into the cervical spine: a rare case report complication 32 months post-clavicle fracture fixation"],"prefix":"10.1097","volume":"138","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9063-5146","authenticated-orcid":false,"given":"Hieu","family":"Nguyen Dinh","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery and Sports Medicine, E Hospital, Hanoi, Vietnam"},{"name":"University of Medicine and Pharmacy, Vietnam National University, Hanoi, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2906-3215","authenticated-orcid":false,"given":"Tuyen","family":"Nguyen Trung","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Sports Medicine, E Hospital, Hanoi, Vietnam"},{"name":"University of Medicine and Pharmacy, Vietnam National University, Hanoi, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,3]]},"reference":[{"key":"R1-20260813","doi-asserted-by":"crossref","first-page":"50\u201353","DOI":"10.1080\/000164702317281404","article-title":"Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation","volume":"73","author":"Flinkkil\u00e4","year":"2002","journal-title":"Acta Orthop Scand"},{"key":"R2-20260813","doi-asserted-by":"crossref","first-page":"111\u201315","DOI":"10.1016\/j.rcot.2011.11.004","article-title":"Migration endopelvienne d\u2019une broche de fixation sternoclaviculaire. Cas clinique et revue de la litt\u00e9rature","volume":"98","author":"Ballas","year":"2012","journal-title":"Revue de Chirurgie Orthop\u00e9dique Et Traumatologique"},{"key":"R3-20260813","first-page":"36\u201340","article-title":"Spinal kirschner wire migration after surgical treatment of clavicular fracture or acromioclavicular joint dislocation: report of a case and meta-analysis","volume":"12","author":"N\u2019da","year":"2018","journal-title":"Interdiscip Neurosurg"},{"key":"R4-20260813","first-page":"100079","article-title":"Revised Surgical CAse REport (SCARE) guideline: an update for the age of Artificial Intelligence","volume":"10","author":"Kerwan","year":"2025","journal-title":"Prem J Sci"},{"key":"R5-20260813","doi-asserted-by":"crossref","first-page":"272\u201375","DOI":"10.1080\/10790268.2017.1419915","article-title":"Migration of a Kirschner wire into the spinal cord: a case report and literature review","volume":"43","author":"Furuhata","year":"2020","journal-title":"J Spinal Cord Med"},{"key":"R6-20260813","doi-asserted-by":"crossref","first-page":"48\u201351","DOI":"10.1016\/S1726-4901(09)70021-8","article-title":"Late migration of threaded wire (schanz screw) from right distal clavicle to the cervical spine","volume":"72","author":"Tsai","year":"2009","journal-title":"J Chin Med Assoc"},{"key":"R7-20260813","doi-asserted-by":"crossref","first-page":"310\u201313","DOI":"10.1016\/j.jocn.2011.05.018","article-title":"Intraspinal migration of a clavicular Steinmann pin: case report and management strategy","volume":"19","author":"Mian","year":"2012","journal-title":"J Clin Neurosci"},{"key":"R8-20260813","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1186\/s13256-016-0844-4","article-title":"Intraspinal migration of a Kirschner wire as a late complication of acromioclavicular joint repair: a case report","volume":"10","author":"Mankowski","year":"2016","journal-title":"J Med Case Rep"},{"key":"R9-20260813","doi-asserted-by":"crossref","first-page":"797\u201399","DOI":"10.1038\/sj.sc.3100683","article-title":"Brown-Sequard syndrome caused by a Kirschner wire as a complication of clavicular osteosynthesis","volume":"36","author":"Lonc\u00e1n","year":"1998","journal-title":"Spinal Cord"},{"key":"R10-20260813","first-page":"390\u201392","article-title":"Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture","volume":"73","author":"Fransen","year":"2007","journal-title":"Acta Orthop Belg"},{"key":"R11-20260813","doi-asserted-by":"crossref","DOI":"10.3928\/01477447-20081201-03","article-title":"Asymptomatic spinal canal migration of clavicular K-wire at the cervicothoracic junction","volume":"31","author":"Bennis","year":"2008","journal-title":"Orthopedics"},{"key":"R12-20260813","first-page":"803\u201306","article-title":"Video-assisted thoracoscopic surgery for migration of a Kirschner wire in the spinal canal: a case report and literature review","volume":"23","author":"Li","year":"2013","journal-title":"Turk Neurosurg"},{"key":"R13-20260813","doi-asserted-by":"crossref","first-page":"110\u201312","DOI":"10.1007\/s101430100186","article-title":"Intraspinal migration of a Kirschner wire 3 months after clavicular fracture fixation","volume":"25","author":"Regel","year":"2002","journal-title":"Neurosurg Rev"},{"key":"R14-20260813","first-page":"367\u201369","article-title":"Spinal migration of a Kirschner wire after surgery for clavicular nonunion. A case report and review of the literature","volume":"28","author":"Mamane","year":"2009","journal-title":"Chir Main"},{"key":"R15-20260813","first-page":"370\u201375","article-title":"Migration of Kirschner wire into the spinal canal as complication of inveterate shoulder luxation treatment - case study","volume":"12","author":"Was","year":"2010","journal-title":"Ortop Traumatol Rehabil"},{"key":"R16-20260813","first-page":"291\u201394","article-title":"Symptomatic migration of a Kirschner wire into the spinal canal without spinal cord injury: case report","volume":"24","author":"Mini\u0107","year":"2016","journal-title":"J Neurol Neurosurg Spine"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RC9.0000000000000656","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T13:01:09Z","timestamp":1786626069000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RC9.0000000000000656"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,3]]},"references-count":16,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rc9.0000000000000656","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,3]]},"assertion":[{"value":"2026-02-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}