{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T16:49:44Z","timestamp":1770223784337,"version":"3.49.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>The purpose of this study was to compare quantitative and qualitative measures of aortic, cardiac, and respiratory motion artifact between high-pitch dual-source (DS) and single-source (SS) computed tomography pulmonary angiography (CTPA) protocols.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This institutional review board\u2013approved, Health Insurance Portability and Accountability Act\u2013compliant study retrospectively reviewed 80 non\u2013electrocardiogram-gated CTPA examinations acquired with a second-generation DS system at 100 kVp following 50 mL iodinated contrast injection \u2014 40 consecutive SS and 40 consecutive DS studies. Quantitative measures of aortic, left ventricular, and diaphragmatic motion were recorded as the maximal excursion of a structure's \u201cdouble image,\u201d and 3 independent readers performed qualitative motion assessments. Pulmonary arterial contrast enhancement, image noise, and radiation dose metrics were recorded. Statistical analyses were performed with 1-way analysis of variance and Fisher exact test.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Dual source outperformed SS technique in both quantitative and qualitative measures of motion. Mean distances between motion-artifact double images were reduced with DS protocol at each location (all <jats:italic toggle=\"yes\">P<\/jats:italic> \u2264 0.004), and DS examinations were more likely to receive an assessment of <jats:italic toggle=\"yes\">no motion<\/jats:italic> in all locations (all <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.0001). The DS protocol demonstrated increases in contrast enhancement, although increased image noise resulted in lower enhancement to noise ratio. Mean radiation dose was 60% lower using the DS protocol.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>High-pitch DS CTPA significantly reduces artifacts resulting from ascending aortic, cardiac, and diaphragmatic motion.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000000736","type":"journal-article","created":{"date-parts":[[2018,4,3]],"date-time":"2018-04-03T15:19:38Z","timestamp":1522768778000},"page":"623-629","source":"Crossref","is-referenced-by-count":9,"title":["Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography"],"prefix":"10.1097","volume":"42","author":[{"given":"Paul M.","family":"Bunch","sequence":"first","affiliation":[{"name":"Brigham and Women's Hospital, Department of Radiology, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Urvi P.","family":"Fulwadhva","sequence":"additional","affiliation":[{"name":"Brigham and Women's Hospital, Department of Radiology, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeremy R.","family":"Wortman","sequence":"additional","affiliation":[{"name":"Brigham and Women's Hospital, Department of Radiology, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew N.","family":"Primak","sequence":"additional","affiliation":[{"name":"Siemens Medical Solutions USA, Inc, Malvern, PA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachna","family":"Madan","sequence":"additional","affiliation":[{"name":"Brigham and Women's Hospital, Department of Radiology, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael L.","family":"Steigner","sequence":"additional","affiliation":[{"name":"Brigham and Women's Hospital, Department of Radiology, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aaron D.","family":"Sodickson","sequence":"additional","affiliation":[{"name":"Brigham and Women's Hospital, Department of Radiology, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20230927","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/RTI.0b013e3181d9ca1d","article-title":"Diagnosing pulmonary embolism: new computed tomography applications","volume":"25","year":"2010","journal-title":"J Thorac Imaging"},{"key":"bib2-20230927","doi-asserted-by":"crossref","first-page":"997","DOI":"10.7326\/0003-4819-129-12-199812150-00002","article-title":"Use of a clinical model for safe management of patients with suspected pulmonary embolism","volume":"129","year":"1998","journal-title":"Ann Intern Med"},{"key":"bib3-20230927","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1164\/ajrccm.159.3.9806130","article-title":"Accuracy of clinical assessment in the diagnosis of pulmonary embolism","volume":"159","year":"1999","journal-title":"Am J Respir Crit Care Med"},{"key":"bib4-20230927","doi-asserted-by":"crossref","first-page":"2276","DOI":"10.1093\/eurheartj\/ehn310","article-title":"Guidelines on the diagnosis and management of acute pulmonary embolism: the Task Force for the Diagnosis and Management of Acute Pulmonary Embolism of the European Society of Cardiology (ESC)","volume":"29","year":"2008","journal-title":"Eur Heart J"},{"key":"bib5-20230927","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1148\/radiol.2452070397","article-title":"Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society","volume":"245","year":"2007","journal-title":"Radiology"},{"issue":"suppl 4","key":"bib6-20230927","first-page":"D37","article-title":"MDCT for the diagnosis of acute pulmonary embolism","volume":"15","year":"2005","journal-title":"Eur Radiol"},{"key":"bib7-20230927","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1097\/01.rti.0000185142.35361.da","article-title":"The age of CT pulmonary angiography","volume":"20","year":"2005","journal-title":"J Thorac Imaging"},{"key":"bib8-20230927","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1111\/j.1553-2712.2004.tb02407.x","article-title":"Prevalence and significance of nonthromboembolic findings on chest computed tomography angiography performed to rule out pulmonary embolism: a multicenter study of 1,025 emergency department patients","volume":"11","year":"2004","journal-title":"Acad Emerg Med"},{"key":"bib9-20230927","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s11547-008-0262-9","article-title":"MDCT of 220 consecutive patients with suspected acute pulmonary embolism: incidence of pulmonary embolism and of other acute or non-acute thoracic findings","volume":"113","year":"2008","journal-title":"Radiol Med"},{"key":"bib10-20230927","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1001\/archinternmed.2009.360","article-title":"The prevalence of clinically relevant incidental findings on chest computed tomographic angiograms ordered to diagnose pulmonary embolism","volume":"169","year":"2009","journal-title":"Arch Intern Med"},{"key":"bib11-20230927","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1378\/chest.13-0157","article-title":"Clinical impact of findings supporting an alternative diagnosis on CT pulmonary angiography in patients with suspected pulmonary embolism","volume":"144","year":"2013","journal-title":"Chest"},{"key":"bib12-20230927","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1097\/00004728-200003000-00016","article-title":"Helical CT for the evaluation of suspected acute pulmonary embolism: diagnostic pitfalls","volume":"24","year":"2000","journal-title":"J Comput Assist Tomogr"},{"key":"bib13-20230927","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1148\/radiol.2371041520","article-title":"The indeterminate CT pulmonary angiogram: imaging characteristics and patient clinical outcome","volume":"237","year":"2005","journal-title":"Radiology"},{"key":"bib14-20230927","doi-asserted-by":"crossref","first-page":"229","DOI":"10.2217\/iim.12.13","article-title":"CT artifacts: causes and reduction techniques","volume":"4","year":"2012","journal-title":"Imaging Med"},{"key":"bib15-20230927","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.2214\/AJR.06.1104","article-title":"How I do it: CT pulmonary angiography","volume":"188","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"bib16-20230927","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1007\/s00330-011-2056-z","article-title":"Computed tomography\u2014old ideas and new technology","volume":"21","year":"2011","journal-title":"Eur Radiol"},{"key":"bib17-20230927","doi-asserted-by":"crossref","first-page":"971","DOI":"10.2214\/AJR.13.10597","article-title":"High-pitch ECG-synchronized pulmonary CT angiography versus standard CT pulmonary angiography: a prospective randomized study","volume":"201","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"bib19-20230927","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1007\/s10140-012-1046-z","article-title":"Effects of patient size on radiation dose reduction and image quality in low-kVp CT pulmonary angiography performed with reduced IV contrast dose","volume":"19","year":"2012","journal-title":"Emerg Radiol"},{"key":"bib20-20230927","doi-asserted-by":"crossref","first-page":"155","DOI":"10.2214\/AJR.09.3673","article-title":"Comparison of respiratory motion artifact from craniocaudal versus caudocranial scanning with 64-MDCT pulmonary angiography","volume":"195","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"bib21-20230927","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/RTI.0b013e31828d4209","article-title":"High-pitch, dual-source chest computed tomography angiography without electrocardiographic synchronization: evaluation of cardiac motion artifacts on pulmonary circulation","volume":"28","year":"2013","journal-title":"J Thorac Imaging"},{"key":"bib22-20230927","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","year":"2007","journal-title":"N Engl J Med"},{"key":"bib23-20230927","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1148\/radiol.10101335","article-title":"Image Wisely: a campaign to increase awareness about adult radiation protection","volume":"257","year":"2010","journal-title":"Radiology"},{"key":"bib24-20230927","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/RTI.0b013e318250067e","article-title":"High-pitch dual-source computed tomography pulmonary angiography in freely breathing patients","volume":"27","year":"2012","journal-title":"J Thorac Imaging"},{"key":"bib25-20230927","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/RTI.0000000000000173","article-title":"High-pitch helical dual-source computed tomographic pulmonary angiography: comparing image quality in inspiratory breath-hold and during free breathing","volume":"31","year":"2016","journal-title":"J Thorac Imaging"},{"key":"bib26-20230927","doi-asserted-by":"crossref","first-page":"2887","DOI":"10.1016\/j.ejrad.2011.09.018","article-title":"Intravenous contrast material administration at high-pitch dual-source CT pulmonary angiography: test bolus versus bolus-tracking technique","volume":"81","year":"2012","journal-title":"Eur J Radiol"},{"key":"bib27-20230927","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1148\/radiol.2353040387","article-title":"Attenuation of acute and chronic pulmonary emboli","volume":"235","year":"2005","journal-title":"Radiology"},{"key":"bib29-20230927","doi-asserted-by":"crossref","first-page":"57","DOI":"10.4103\/2156-7514.100999","article-title":"Feasibility of computed tomography pulmonary angiography with low flow rates","volume":"2","year":"2012","journal-title":"J Clin Imaging Sci"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004728-201807000-00020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T18:08:21Z","timestamp":1695838101000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004728-201807000-00020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000000736","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7]]}}}